You are on page 1of 95

Auto Switches

Precautions 1
Be sure to read before handling.
For detailed precautions on every series, refer to main text.

Design and Selection


Warning
1. Check the specifications. • Similarly, when operating below a specified voltage, it is
Read the specifications carefully and use this product possible that the load may be ineffective even though the
appropriately. The product may be damaged or malfunction if it auto switch function is normal. Therefore, the formula below
is used outside the range of specifications of current current, should be satisfied after confirming the minimum operating
voltage, temperature or impact. voltage of the load.
2. Use caution when multiple cylinders are used Supply – Internal voltage > Minimum operating
voltage drop of switch voltage of load
and close to each other.
When two or more auto switch cylinders are lined up in close 2) If the internal resistance of a light emitting diode causes a
proximity to each other, magnetic field interference may cause problem, select a switch without an indicator for right
the switches to malfunction. Maintain a minimum cylinder (MODEL D-A6/A80/A80H/A90/A90V/C80/R80/90/E80A/
separation of 40 mm. (When the allowable interval is specified Z80)
for each cylinder series, use the indicated value.) <Solid state switches>
3) Generally, the internal voltage drop will be greater with a 2-
3. Use caution to the ON time of a switch at the
wire solid state auto switch than with a reed switch. Take the
intermediate position of stroke. same precautions as in 1).
When an auto switch is placed at an intermediate position of
Also note that a 12 VDC relay is not applicable.
the stroke and a load is driven at the time the piston passes,
the auto switch will operate, but if the speed is too great, the 6. Use caution to the leakage current.
operating time will be shortened and the load may not operate <Solid state switches>
properly. The maximum detectable piston speed is: With a 2-wire solid state auto switch, current (leakage current)
flows to the load to operate the internal circuit even when in
Auto switch operating range (mm) the OFF state.
V (mm/s) = x 1000
Load operating time (ms)
Current to operate load (OFF condition) > Leakage current
In cases of high piston speed, the use of an auto switch (D-
F5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer If the condition given in the above formula is not met, it will not
(≅ 200 ms) makes it possible to extend the load operating time. reset correctly (stays ON). Use a 3-wire switch if this
specification cannot be satisfied.
4. Wiring should be kept as short as possible. Moreover, leakage current flow to the load will be “n” times
<Reed switches>
larger when “n” auto switches are connected in parallel.
As the length of the wiring to a load gets longer, the rush
current at switching ON becomes greater, and this may 7. Do not use a load that generates surge voltage.
shorten the product’s life. (The switch will stay ON all the time.) <Reed switches>
1) For an auto switch without a connect protection circuit, use If driving a load such as a relay that generates a surge voltage,
a contact protection box when the wire length is 5 m or use a switch with a built-in contact protection circuit or use a
longer. contact protection box.
2) Even if an auto switch has a built-in contact protection <Solid state switches>
circuit, when the wiring is more than 30 m long, it is not able Although a zener diode for surge protection is connected at the
to adequately absorb the rush current and its life may be output side of a solid state auto switch, damage may still occur
reduced. It is again necessary to connect a contact if the surge is applied repeatedly. When a load, such as a relay
protection box in order to extend its life. Please contact or solenoid, which generates surge is directly driven, use a
SMC in this case. type of switch with a built-in surge absorbing element.
<Solid state switches> 8. Cautions for use in an interlock circuit
3) Although wire length should not affect switch function, use a When an auto switch is used for an interlock signal requiring
wire 100 m or shorter. high reliability, devise a double interlock system to avoid
5. Use caution to the internal voltage drop of a trouble by providing a mechanical protection function, or by
switch. also using another switch (sensor) together with the auto
<Reed switches> switch.
1) Switches with an indicator light (Except D-A56/A76H/A96/ Also perform periodic maintenance inspections and confirm
A96V/C76/E76A/Z76) proper operation.
• If auto switches are connected in series as shown below, 9. Ensure sufficient space for maintenance
take note that there will be a large voltage drop because of activities.
internal resistance in the light emitting diodes. (Refer to When designing an application, be sure to allow sufficient
internal voltage drop in the auto switch specifications.) space for maintenance and inspection.
[The voltage drop will be “n” times larger when “n” auto
switches are connected.]
Even though an auto switch operates normally, the load
may not operate.

Load

6-16-4
Auto Switches
Precautions 2
Be sure to read before handling.
For detailed precautions on every series, refer to main text.

Mounting and Adjustment <Solid state switches>


Model D-F9(Y)/F9W(V)/J51/G5NB and all models of PNP
Warning output switches do not have built-in short circuit prevention
circuits. If loads are short circuited, the switches will be
1. Do not drop or bump. instantly damaged.
Do not drop, bump, or apply excessive impacts (300 m/s2 or
Use caution to avoid reverse wiring with the brown [red] power
CJ1
more for reed switches and 1000 m/s2 or more for solid state
supply line and the black [white] output line on 3-wire type
switches) while handling. Although the body of the switch may
switches. CJP
not be damaged, the inside of the switch could be damaged
and cause a malfunction. 6. Avoid incorrect wiring.
<Reed switches> CJ2
2. Do not carry a cylinder by the auto switch lead A 24 VDC switch with indicator light has polarity. The brown
wires. lead wire or terminal no. 1 is (+), and the blue lead wire or CM2
Never carry a cylinder by its lead wires. This may not only terminal no. 2 is (–).
cause broken lead wires, but it may cause internal elements of [In the case of model D-97, the side without indicator is (+), CG1
the switch to be damaged by the stress. and the black line side is (–).]
3. Mount switches using the proper tightening 1) If connections are reversed, a switch will operate, however, MB
torque. the light emitting diode will not light up.
When a switch is tightened beyond the range of fastening Also note that a current greater than the maximum specified MB1
torque, the mounting screws or switch may be damaged. one will damage a light emitting diode and make it
On the other hand, tightening below the range of fastening inoperable.
Applicable models:
CA2
torque may alllow the switch to slip out of position. (Refer to
switch mounting for each series regarding switch mounting, D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73
moving, and fastening torque, etc.) D-97/93A/A93/A93V
CS1
4. Mount a switch at the center of the operating D-A33/A34/A33A/A34A/A44/A44A
D-A53/A54/B53/B54 C76
range.
2) However, when using a two color indication auto switch, the
Adjust the mounting position of an auto switch so that the
piston stops at the center of the operating range (the range in
switch (D-A79W/A59W/B59W), be aware that the switch C85
will constantly remain ON if the connections are reversed.
which a switch is ON). (The mounting positions shown in the
catalog indicate the optimum position at the stroke end.) If
<Solid state switches> C95
1) If connections are reversed on a 2-wire type switch, the
mounted at the end of the operating range (around the
borderline of ON and OFF), the operation will be unstable.
switch will not be damaged if protected by a protection CP95
circuit, but the switch will always stay in an ON state.
However, it is still necessary to avoid reversed connections, NCM
Wiring since the switch could be damaged by a load short circuit in
this condition.
Warning 2) If connections are reversed (power supply line (+) and
NCA
1. Avoid repeatedly bending or stretching lead power supply line (–) on a 3-wire type switch, the switch will
wires. be protected by a protection circuit. However, if the power D-
Broken lead wires will result from repeatedly applying bending supply line (+) is connected to the blue (black) wire and the
stress or stretching force to the lead wires. power supply line (–) is connected to the black (white) wire, -X
the switch will be damaged.
2. Be sure to connect the load before power is
applied.
20-
<2-wire type>
If the power is turned on when an auto switch is not connected Data
to a load, the switch will be instantly damaged because of
∗ Lead wire color changes
excess current.
Lead wire colors of SMC auto switches have been changed in
3. Confirm proper insulation of wiring. order to meet NECA Standard 0402 for production beginning
Be certain that there is no faulty wiring insulation (contact with September, 1996 and thereafter. Please refer to the tables
other circuits, ground fault, improper insulation between provided.
terminals, etc.). Damage may occur due to excess current flow 2-wire 3-wire
into a switch. Old New Old New
4. Do not wire with power lines or high voltage Output (+) Red Brown Power supply (+) Red Brown
Output (–) Black Blue Power supply GND Black Blue
lines.
Output White Black
Wire separately from power lines or high voltage lines, Solid State
avoiding parallel wiring or wiring in the same conduit with with Diagnostic Output Solid State with
these lines. Control circuits including auto switches may Old New Latch Type Diagnostic Output
malfunction due to noise from these other lines. Power supply (+) Red Brown Old New
Power supply GND Black Blue
5. Do not allow short circuiting of loads. Power supply (+) Red Brown
Output White Black Power supply GND Black Blue
<Reed switches>
Diagnostic output Yellow Orange Output White Black
If the power is turned on with a load in a short circuited
condition, the switch will be instantly damaged because of Latch type
Yellow Orange
diagnostic output
excess current flow into the switch.

6-16-5
Auto Switches
Precautions 3
Be sure to read before handling.
For detailed precautions on every series, refer to main text.

Operating Environment Maintenance


Warning Warning
1. Never use in the presence of explosive gases. 1. Perform the following maintenance periodically
The construction of our auto switches does not make them in order to prevent possible danger due to
explosion-proof. Never use them in the presence of an unexpected auto switch malfunction.
explosive gas, as this may cause a serious explosion. 1) Securely tighten switch mounting screws.
2. Do not use in an area where a magnetic field is If screws become loose or the mounting position is
generated. dislocated, retighten screws securely after readjusting the
Auto switches will malfunction or magnets inside cylinders will mounting position.
become demagnetized. (Please consult with SMC regarding 2) Confirm that there is no damage to lead wires.
the availability of a magnetic field resistant auto switch.) To prevent faulty insulation, replace switches or repair lead
wires if damage is discovered.
3. Do not use in environments where the auto
3) Confirm that the green light on the 2-color indicator type
switches will be constantly exposed to water.
switch lights up.
Although switches except D-A3/A44/G39/K39 satisfy the
Confirm that the Green LED is ON when stopped at the set
IEC standard IP67 structure (JIS C 0920: anti-immersion
position. If the Red LED is ON when stopped at the set
structure), do not use switches in applications where
position, the mounting position is not appropriate. Readjust
continually exposed to water splash or spray. Poor insulation or
the mounting position until the Green LED lights up.
swelling of the potting resin inside switches may cause
malfunction.
4. Do not use in environments with oil or Other
chemicals. Warning
Please consult with SMC if auto switches will be used in an
environment with coolants, cleaning solvents, various oils or 1. Please consult with SMC concerning water
chemicals. If auto switches are used under these conditions for resistance, elasticity of lead wires, and use at
even a short time, they may be adversely affected by improper welding sites.
insulation, a malfunction due to swelling of the potting resin, or
hardening of the lead wires.
5. Do not use in an environment with temperature
cycles.
Please consult with SMC if switches are to be used where
there are temperature cycles other than normal temperature
changes, as they may be adversely affected internally.
6. Do not use in environments where there is
excessive impact shock.
<Reed switches>
When excessive impact (300 m/s2 or more) is applied to a reed
switch during operation, the contact point may malfunction and
generate or cut off a signal momentarily (1 ms or less). Please
consult with SMC regarding the need to use a solid state
switch depending on the environment.
7. Do not use in locations where surges are
generated.
<Solid state switches>
When there are units (solenoid type lifters, high frequency
induction furnaces, motors, etc.) which generate a large
amount of surge in the area around cylinders with solid state
auto switches, this may cause deterioration or damage to the
switches. Avoid sources of surge generation and crossed lines.
8. Avoid accumulation of iron debris or close
contact with magnetic substances.
When a large amount of ferrous debris such as machining
chips or spatter is accumulated, or a magnetic substance
(something attracted by a magnet) is brought into close
proximity with an auto switch cylinder, it may cause the auto
switches to malfunction due to a loss of the magnetic force
inside the cylinder.

6-16-6
Before Operation
Auto Switches Common Specifications

Precautions
Refer to “Auto Switches Precautions” on pages 6-16-4 to 6-16-6 before handling.

Auto Switches Common Specifications CJ1


Note 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C)
Type Reed switch Solid state switch
and D-9/9A/A9/A9V type: 1000 VAC/min. (Between CJP
Leakage current None 3-wire: 100 µA or less, 2-wire: 0.8 mA or less (4) lead wire and the case)
Operating time 1.2 ms 1 ms or less (3)
Note 2) The following switches, Terminal conduit type (D-
A3/A3A/A3C/G39/G39A/G39C/K39/K39A/K39C), DIN
CJ2
Impact resistance 300 m/s2 1000 m/s2 terminal type (D-A44/A44A/A44C) and Heat resistant auto
Insulation resistance 50 MΩ or more at 500 M VDC (Between lead wire and case)
switch (D-F7NJL) meet the IEC529 standard. CM2
Note 3) IP63, JIS C 0920 Rainproof construction
Except solid state switch with timer (D-M5TL,
Withstand voltage
1500 VAC for 1 minute (1) 1000 VAC for 1 minute
(Between lead wire and case)
G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indi- CG1
(Between lead wire and case)
cation type solid state switch (D-P5DWL). D-J51: 5 ms or
Ambient temperature –10 to 60°C
less
Note 4) Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at
MB
Enclosure IEC529 Standard IP67, Immersible construction (JIS C 0920) (2) 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1
mA or less at 24 VDC). MB1
Lead Wire Length Contact Protection Box: CD-P11, CD-P12
Lead wire length indication 1
CA2
Note 1) Applicable auto switch with 5
m lead wire (“Z”) <Applicable switch types>
(Example)
D-A73 L Reed switch: D-B53/B54, D- D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, D- CS1
Lead wire length • C73(C)/C80C, D-A73(C)(H)/ E7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type
A80C, D-A53/A54, D-Z73, D- The above auto switches do not have internal contact protection circuits.
Nil 0.5 m Z 5 m
90/97/90A/93A 1. Operating load is an inductive load. C76
L 3m N ∗ None Solid state switch: 2. The length of wiring to the load is 5 m or more.
3. The load voltage is 100 or 200 VAC.
∗ Applicable for the connector
type (D-C) only.
Manufactured upon receipt of
A contact protection box should be used in any of the above
C85
order as standard.
Note 2) The standard lead wire length conditions, Unless using a contact protection box, the contact life may
(Example)
D-F8PL- 61 of solid state switches with be shortened. (Due to permanent energizing conditions.) C95
timer, water resistant 2-color D-A72(H) must be used with the contact protection box regardless
Flexible lead wire • indication type, wide range of load styles and lead wire length.
specifications detection type or heat 2 CP95
(D-Y59, D-Y69, D-Y7 and D-M9/M9V resistant 2-color indication Please contact SMC when using built-in contact protection circuit style (D-
series use flexible lead wire as srandard. ) type is 3 meters in length. A34[A][C], D-A44[A][C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) in the
following conditions: 1. The wiring length to load is more than 30 m; 2.
NCM
(0.5 m is not available.)
Part No. of Lead Wires Note 3) Lead wire lengths of 3 m and When using PLC with large flow current.
with Connectors 5 m are standard for magnetic NCA
(Applicable only for connector type) field resistant 2-color indicator Contact Protection Box Specifications
type solid state switches. (0.5
Model Lead wire length m is not available.)
Part no. CD-P11 CD-P12 D-
D-LC05 0.5 m Load voltage 100 VAC or less 200 VAC 24 VDC
Note 4) Add “-61” at th end of the part
D-LC30 3m number for the flexible lead Max. load current 25 mA 12.5 mA 50 mA -X
wire except D-Y59, D-Y69, D- ∗ Lead wire length — Switch connection side 0.5 m
D-LC50 5m Y7 and D-M9/M9V type Load connection side 0.5 m
auto switches. 20-
Contact Protection Box Internal Circuit
Auto Switch Hysteresis
CD-P11
Choke
OUT Brown Data
Hysteresis is the distance between the position at which piston movement Surge absorber coil ~
operates an auto switch to the position at which reverse movement turns OUT Blue
the switch off. This hysteresis is included in part of the operating range
(one side). CD-P12 OUT (+) Brown
Choke
Auto switch Zener diode coil
OUT (–) Blue

Contact Protection Box/Dimensions


Switch
operating
Note)
position
(ON) Hysteresis Reed switch: 2 mm or less
Solid state switch: 1 mm or less

Switch Contact Protection Box Connection


operating
position To connect a switch unit to a contact protection box, connect the lead wire
(OFF) from the side of the contact protection box marked SWITCH to the lead
Note) Hysteresis may fluctuate due to the operating environment. wire coming out of the switch unit. Keep the switch as close as possible to
Please contact SMC if hysteresis causes an operational problem. the contact protection box, with a lead wire length of no more than 1
meter.
6-16-7
Before Operation
Auto Switches Connection and Example

Basic Wiring
Solid state 3-wire, NPN Solid state 3-wire, PNP Solid state 2-wire Reed switch 2-wire
Brown Brown Brown Brown
Load Load
Load Indicator
Main Main Main protection
curcuit Black curcuit Black curcuit ~
of switch of switch of switch circuit,
Load
etc.

Blue Blue Blue Blue


(Power supply for switch and load are separate)
Brown Brown Brown

Load Indicator
Main Main protection
curcuit Black curcuit ~
of switch of switch circuit,
etc.
Load Load
Blue Blue Blue

Example of Connection with PLC (Programmable Logic Controller)


• Sink input specifications • Source input specifications Connect according to the applicable PLC
input specifications, as the connection
3-wire, NPN 3-wire, PNP method will vary depending on the PLC
Black Input Black Input
input specifications.
Brown Brown
Switch Switch
Blue Blue
COM COM
PLC internal circuit PLC internal circuit

2-wire 2-wire
Brown Input Blue Input

Switch Switch

Blue COM Brown COM


PLC internal circuit PLC internal circuit

Example of AND (Series) and OR (Parallel) Connection


• 3-wire
AND connection for NPN output AND connection for NPN output OR connection for NPN output
(Using relays) (Performed with switches only)
Brown Brown Brown
Load
Black Black Black
Switch 1 Relay Switch 1 Load Switch 1 Load
Blue Relay Blue Blue
contact
Brown Brown Brown
Black Black Black
Switch 2 Relay Switch 2 Switch 2
Blue Blue Blue

The indicator lights will light up when


both switches are turned ON.
• 2-wire
2-wire with 2-switch AND connection 2-wire with 2-switch OR connection
When two switches are (Solid state switch) (Reed switch)
Brown connected in series, a load Brown When two switches are Because there is no
Load may malfunction because Load
connected in parallel, current leakage, the load
Switch 1 the load voltage will decline Switch 1 malfunction may occur voltage will not increase
Blue Blue
when in the ON state. because the load voltage when turned OFF.
The indicator lights will light will increase when in the However, depending on
Brown up when both of the Brown OFF state. the number of switches in
Switch 2 switches are in the ON Switch 2
the ON state, the
Blue
state. Blue indicator lights may
sometimes grow dim or
Load voltage at ON = Power supply voltage – Residual voltage x 2 pcs. Load voltage at OFF = Leakage current x 2 pcs. x Load impedance not light up, due to the
dispersion and reduction
= 24 V – 4 V x 2 pcs. = 1 mA x 2 pcs. x 3 kΩ
of the current flowing to
= 16 V =6V the switches.
Example: Power supply is 24 VDC Example: Load impedance is 3 kΩ.
Internal voltage drop in switch is 4 V. Leakage current from switch is 1 mA.

6-16-8
6-15-36
Reed Switch
Band Mounting Style
D-C73/D-C76/D-C80 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-C7 (With indicator light)
Auto switch model D-C73 D-C76
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC
Max. load current and range (3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less 0.8 V or less
Indicator light Red LED lights when ON.
D-C8 (Without indicator light)
Auto switch model D-C80
Applicable load Relay, PLC, IC circuit
Load voltage AC
24 V DC or less AC
48 V DC AC
100 V DC
Max. load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
Auto Switch Internal Circuit 2 cores (Brown, Blue), 0.5 m
D-C73 Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
LED Brown Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
OUT (+) indicator light will not be possible where the output signal is less than 2.5 mA. However,
Resistor Contact Brown
Reed switch

protection there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Zener box  more.
diode CD-P11
CD-P12
OUT (–)
Blue Blue
Weight
(g)
Auto switch model D-C73 D-C76 D-C80
D-C76 0.5 9 10 9
Lead wire length
DC (+) (m) 3 46 50 46
LED Brown
(+) 5 76 — —
Resistor
Reed switch

Load
Reverse OUT DC
current
prevention Black
diode
DC (–)
(–) Dimensions
Blue

D-C80
Reed switch

Contact OUT (±) Indicator light


protection Brown
box  D-C80 without indicator light
CD-P11
±
OUT ( )
CD-P12
Blue

Note 1) Operating load is an induction load.


Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the Most sensitive position
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.)

6-16-10
Reed Switch
Band Mounting Style
D-B53/D-B54/D-B64 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-B5 (With indicator light)
Auto switch model D-B53 D-B54 CJ1
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC CJP
Load current range (3) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in CJ2
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED lights when ON.
CM2
D-B6 (Without indicator light)
CG1
Auto switch model D-B64
Applicable load Relay, PLC MB
Load voltage 24 V AC
DC or less 100 VAC 200 VAC
Max. load current Max. 50 mA Max. 25 mA Max. 12.5 mA MB1
Contact protection circuit Built-in
Internal resistance 25 Ω or less CA2
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7. CS1
Auto Switch Internal Circuit Note 2) Regarding the lead wire length, refer to page 6-16-7.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
D-B53 indicator light will not be possible where the output signal is less than 2.5 mA. However, C76
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more. C85

OUT (–)
Reed switch LED
OUT (+)
Weight C95
Blue Resistor Brown
(g)
CP95
Zener diode Auto switch model D-B53 D-B54 D-B64

Lead wire length


0.5 22 22 22 NCM
(m) 3 78 78 78
5 126 126 — NCA
D-B54
Dimensions D-
Zener diode

Resistor
Choke coil
-X
OUT (–) OUT (+)
Blue Reed switch LED
20-
Surge absorber
Data
Indicator light
DB64 without
indicator light
D-B64
Choke coil

OUT ( )  OUT (±) 


±
Blue Reed switch Brown
Most sensitive
Surge absorber position

6-16-11
Reed Switch
Band Mounting Style
D-C73C/D-C80C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Connector Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller

D-C73C (With indicator light)


Auto switch model D-C73C
Applicable load Relay, PLC
Load voltage 24 VDC
Load current range (4) 5 to 40 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED lights when ON.
D-C80C (Without indicator light)
Auto switch model D-C80C
Caution Applicable load Relay, PLC
Precautions Load voltage 24 V AC
DC or less
1. Confirm that the connector is appropriately Maximum load current 50 mA
tightened. If tightened insufficiently, the
waterproof performance will deteriorate. Contact protection circuit None
2. For details, refer to page 6-16-63. Internal resistance 1 Ω (Including lead wire length of 3 m)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Auto Switch Internal Circuit Note 3) Lead wire with connector may be shipped with switch.
Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
D-C73C indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Contact protection box more.
CD-P12
LED Choke coil
Brown
OUT (±)
Resistor Brown Weight
Reed switch

Zener
Zener diode diode
(g)
±
OUT ( ) Auto switch model D-C73C D-C80C
Blue Blue
0.5 14 14
Lead wire length
(m) 3 53 53
D-C80C 5 83 83

Contact protection box


OUT (±)
Dimensions
Reed switch

CD-P11
CD-P12 Brown
 Lead wire with connector
±
OUT ( )
Blue

Indicator light
Note 1) Operating load is an induction load. D-C80C without
Note 2) Wiring to the load is 5 m or longer. indicator light
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.)

Most sensitive position

6-16-12
Reed Switch
Band Mounting Style
D-A33/D-A34/D-A44 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit: D-A3 Auto Switch Specifications


DIN terminal: D-A4 PLC: Abbreviation of Programmable Logic Controller

D-A3 (With indicator light) Terminal conduit


Auto switch model D-A33 D-A34 CJ1
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC CJP
(2)
Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in
CJ2
Internal voltage drop 2.4 V or less ≤ 2.4 V (to 20 mA)/≤ 3.5 V (to 50 mA)
Indicator light
CM2
Red LED lights when ON.
D-A44 (With indicator light) DIN terminal CG1
Caution
Auto switch model D-A44
Precautions Applicable load Relay, PLC MB
1. Use cable whose O.D. is within the size in
Load voltage 24 VDC 100 VAC 200 VAC
the figure to maintain water resistant
performance. Load current range 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
MB1
2. After wiring, confirm that tightening gland Contact protection circuit Built-in
and all screws are tightened.
Internal voltage drop
CA2
2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED lights when ON. CS1
Auto Switch Internal Circuit Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
D-A33 indicator light will not be possible where the output signal is less than 2.5 mA. However, C76
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more. C85
Reed switch LED
OUT (–)
Terminal no. 2 Resistor
OUT (+)
Terminal no. 1 Weight C95
Zener diode
(g) CP95
Auto switch model D-A33 D-A34 D-A44
Lead wire None 116 116 114 NCM
NCA
D-A34, D-A44 Dimensions
D-
D-A3 D-A44
Choke coil Tightening
Reed switch LED gland Tightening
gland
-X
OUT (–)  Resistor OUT (+) 
Terminal no. 2 Terminal no. 1
Zener diode 20-
Surge absorber

G 1/2
Data
G 1/2
Applicable cable O.D. ø6.8 to ø9.6 Applicable cable O.D. ø6.8 to ø11.5

Indicator light
Most sensitive position
Most sensitive position

6-16-13
Reed Switch
Band Mounting Style
D-A33A/D-A34A/D-A44A For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit: D-A3A Auto Switch Specifications


DIN terminal: D-A44A PLC: Abbreviation of Programmable Logic Controller
D-A3 A (With indicator light) Terminal conduit
Auto switch model D-A33A D-A34A
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VAC 100 VAC 200 VAC
Load current range (2) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less ≤ 2.4 V (to 20 mA)/≤ 3.5 V (to 50 mA)
Caution Indicator light Red LED lights when ON.
Precautions D-A44A (With indicator light) DIN terminal
1. Use cable whose O.D. is within the size in
Auto switch part model D-A44A
the figure to maintain water resistant
performance. Applicable load Relay, PLC
2. After wiring, confirm that tightening gland Load voltage 24 VDC 100 VAC 200 VAC
and all screws are tightened. Load current range 5 to 25 mA 5 to 12.5 mA
5 to 50 mA
Contact protection circuit Built-in
Auto Switch Internal Circuit Internal voltage drop 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
D-A33A Indicator light Red LED lights when ON.
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Reed switch LED Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
OUT (–) OUT (+) indicator light will not be possible where the output signal is less than 2.5 mA. However,
Terminal no. 2 Terminal no. 1
Resistor there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
Zener diode

Weight
D-A34A, D-A44A (g)

Choke coil Auto switch model D-A33A D-A34A D-A44A


Reed switch LED
Lead wire None 112 112 110
OUT (–)  Resistor OUT (+) 
Terminal no. 2 Terminal no. 1
Zener diode
Surge absorber

Dimensions
D-A3A D-A44
G 1/2
(Applicable cable O.D. Tightening gland
ø6.8 to ø9.6)

Tightening gland G 1/2


(Applicable cable O.D.
ø6.8 to ø11.5)

Most sensitive position Most sensitive position

6-16-14
Reed Switch
Band Mounting Style
D-A72/D-A73/D-A80 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Electrical entry: Perpendicular PLC: Abbreviation of Programmable Logic Controller

D-A7 (With indicator light)


Auto switch model D-A72 D-A73 CJ1
Applicable load Relay, PLC Relay, PLC
Load voltage 200 VAC 24 VDC 100 VAC CJP
(3)
Load current range 5 to 10 mA 5 to 40 mA 5 to 20 mA
Contact protection circuit None
CJ2
Internal voltage drop 2.4 V or less
CM2
Indicator light Red LED lights when ON.
D-A8 (Without indicator light) CG1
Auto switch model D-A80
Applicable load Relay, IC circuit, PLC MB
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC

Maximum load current 50 mA 40 mA 20 mA


MB1
Contact protection circuit None
Auto Switch Internal Circuit CA2
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
D-A72 • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
CS1
Contact protection box
CD-P11 Note 2) Regarding the lead wire length, refer to page 6-16-7.
LED Brown
OUT
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the C76
Resistor Choke
Brown indicator light will not be possible where the output signal is less than 2.5 mA. However,
coil
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Reed switch

Zener diode  more.


C85
Surge
absorber

Blue
OUT
Blue
C95
Weight
CP95
(g)
D-A73 Auto switch model D-A72 D-A73 D-A80 NCM
0.5 10 10 10
Lead wire length
LED Brown (m) 3 47 47 47 NCA
OUT (+)
Resistor Contact
protection
Brown 5 — 77 —
D-
Reed switch

Zener diode box 


CD-P11
CD-P12
OUT (–) Dimensions -X
Blue Blue

Indicator light 20-


D-A80 without
indicator light
D-A80 Data
15 (14)

23 (22)
Contact OUT (±)
Reed switch

protection Brown
box

CD-P11 ±
CD-P12 OUT ( )
Blue
6 (6.2) 3

9 (8.5) Most sensitive position

Note 1) Operating load is an induction load. ( ) values for D-A72


Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.)

6-16-15
Reed Switch
Rail Mounting Style
D-A7 H/D-A80H For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller

D-A7H (With indicator light)


Auto switch model D-A72H D-A73H D-A76H
Applicable load Relay, PLC Relay, PLC IC circuit
Load voltage 200 VAC 24 VDC 100 VAC 4 to 8 VDC
Max. load voltage/Load current range (3) 5 to 10 mA 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit 2.4 V or less 0.8 V or less
Internal voltage drop None
Auto Switch Internal Circuit
Indicator light Red LED lights when ON.
D-A72H D-A80H (Without indicator light)
Contact protection box
CD-P11 Auto switch model D-A80H
LED Brown
OUT
Applicable load Relay, IC circuit, PLC
Resistor Choke AC AC AC
Brown Load voltage 24 V DC or less 48 V DC 100 V DC
coil
Reed switch

Zener diode  Maximum load current 50 mA 40 mA 20 mA


Surge
absorber
OUT Contact protection circuit None
Blue Blue
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
• Lead wire — Oil resistant vinyl heavy-duty cord, 0.2 mm2, 2 cores (Brown, Blue), 3 cores (Brown,
Black, Blue), 0.5 m
D-A73H Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
LED Brown
OUT (+)
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Resistor Contact more.
Brown
protection
Reed switch

Zener diode box


CD-P11 
CD-P12
OUT (–)
Weight
Blue Blue
(g)
Auto switch model D-A72H D-A73H D-A76H D-A80H
D-A76H 0.5 10 10 11 10
Lead wire length
3 47 47 52 47
(m)
DC (+) 5 — 77 — —
LED Brown
(+)
Resistor
Reed switch

Load
Reverse OUT DC power
current
prevention
diode
Black supply
Dimensions
(–)
DC (–)
Blue
D-A7H, D-A80H

D-A80H
Reed switch

Contact OUT (±) Indicator light


protection Brown
D-A80H without
box  indicator light
CD-P11 ±
CD-P12 OUT ( )
Blue

Note 1) Operating load is an induction load.


Note 2) In the case the wiring length to load is Most sensitive position
more than 5 m.
Note 3) Wiring to the load is 5 m or longer.
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. Especially in the case of
D-A72H, be sure to use the contact
protection box. (Refer to page 6-16-7 for
contact protection box.)

6-16-16
Reed Switch
Rail Mounting Style
D-A73C/D-A80C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Connector Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-A73C (With indicator light)
Auto switch model D-A73C CJ1
Applicable load Relay, PLC
Load voltage 24 VDC CJP
Load current range 5 to 40 mA
Contact protection circuit
(4)
None CJ2
Internal voltage drop 2.4 V or less
Indicator light Red LED lights when ON.
CM2
D-A80C (Without indicator light) CG1
Caution
Auto switch model D-A80C
Precautions Applicable load Relay, IC circuit, PLC MB
1. Confirm that the connector is appropriately AC
Load voltage 24 V DC
tightened. If tightened insufficiently, the
waterproof performance will deteriorate. Maximum load current 50 mA MB1
2. Refer to page 6-16-63 for the details. Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
CA2
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
CS1
Auto Switch Internal Circuit Note 2) Regarding the lead wire length, refer to page 6-16-7.
Note 3) Lead wire with connector may be shipped with switch. C76
D-A73C Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
Contact protection box indicator light will not be possible where the output signal is less than 2.5 mA. However,
CD-P12
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
C85
LED Choke coil
Brown more.
OUT (+)
Resistor Brown C95
Reed switch

Zener
Zener diode diode Weight
CP95
OUT (–) (g)
Blue Blue
Auto switch model D-A73C D-A80C NCM
0.5 12 12
Lead wire length
(m) 3 54 54 NCA
D-A80C
5 84 84
D-
Contact OUT (±) Dimensions
Reed switch

protection Brown -X
box

CD-P11
CD-P12 ±
OUT ( ) 20-
Blue
Lead wire
with connector Data
Indicator light
Note 1) Operating load is an induction load. D-A80C without
Note 2) Wiring to the load is 5 m or longer. indicator light
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.)

Most sensitive position

6-16-17
Reed Switch
Tie-rod Mounting Style
D-A5 /D-A6  For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-A5 (With indicator light)
Auto switch part model D-A53 D-A54 D-A56
Applicable load PLC Relay, PLC IC circuit
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC 4 to 8 VDC
Maximum load (3)
5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA 20 mA
current and range
Contact protection circuit None Built-in None
Internal voltage drop 2.4 V or less ≤ 2.4 V (to 20 mA)/≤ 3.5 V (to 50 mA) 0.8 V or less
Indicator light Red LED lights when ON.
D-A6 (Without indicator light)
Auto switch model D-A64 D-A67
Applicable load Relay, PLC PLC/IC circuit
AC
Load voltage 24 V DC or less 100 VAC 200 VAC Max. 24 VDC
Maximum load current 50 mA 25 mA 12.5 mA 30 mA
Contact protection circuit Built-in None
Auto Switch Internal Circuit 1 Ω or less
Internal resistance 25 Ω or less (Including lead wire
D-A53 length of 3 m)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), or 0.2 mm 3
cores (Brown, Black, Blue), 0.5 m
Reed switch LED
OUT (–)
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
OUT (+)
Blue Brown Note 2) Regarding the lead wire length, refer to page 6-16-7.
Resistor
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
Zener diode
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.

D-A54
Zener diode Weight
Choke coil
Resistor (g)
OUT (–)  OUT (+) 
Blue Reed LED
Auto switch model D-A53 D-A54 D-A56 D-A64 D-A67
switch
0.5 24 24 24
Lead wire length
Surge absorber 3 48 48 48
(m)
5 96 — —
D-A56
DC (+)
LED Brown
(+)
Dimensions
Resistor
Reed switch

Load
Reverse OUT DC power supply
current Black
prevention
diode
(–)
DC (–)
Blue

D-A64
Choke coil Indicator light
D-A64/A67 without
OUT ( ) 
±
OUT (±)  indicator light
Blue Reed switch Brown

Surge absorber

D-A67

Most sensitive position


Reed switch
OUT ( )
±
OUT (±)
Blue
Brown

6-16-18
Reed Switch
Tie-rod Mounting Style
D-A33C/D-A34C/D-A44C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit:D-A3C Auto Switch Specifications


DIN terminal: D-A44C PLC: Abbreviation of Programmable Logic Controller
D-A3C (With indicator light) Terminal conduit
Auto switch model D-A33C D-A34C
Applicable load PLC Relay, PLC CJ1
Load voltage 24 VDC 24 VAC 100 VAC 200 VAC
Load current range (2) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA CJP
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less ≤ 2.4 V (to 20 mA)/≤ 3.5 V (to 50 mA)
CJ2
Indicator light Red LED lights when ON.
CM2
Caution D-A44C (With indicator light) DIN terminal
Precautions
Auto switch model D-A44C CG1
Applicable load Relay, PLC
1. Use cable whose O.D. is within the size in
the figure to maintain water resistant Load voltage 24 VDC 100 VAC 200 VAC MB
performance. Load current range (2) 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
2. After wiring, confirm that tightening gland Contact protection circuit Built-in
MB1
and all screws are tightened.
Internal voltage drop 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
CA2
Indicator light
Auto Switch Internal Circuit Red LED lights when ON.

D-A33C
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
CS1
light will not be possible where the output signal is less than 2.5 mA. However, there is no
Reed switch LED
problem in terms of contact output, when an output signal exceeds 1 mA or more. C76
OUT (–)
Terminal no. 2 Resistor
OUT (+)
Terminal no. 1
Weight
(g) C85
Zener diode
Auto switch model D-A33C D-A34C D-A44C
C95
40 162 162 160

D-A34C, D-A44C Applicable bore size


50 166 166 164
CP95
63 184 184 182
(mm)

Reed switch LED


Choke coil 80 210 210 208 NCM
100 232 232 230
OUT (–)  Resistor OUT (+) 
Terminal no. 2 Terminal no. 1
Dimensions NCA
Zener diode
Surge absorber (mm) D-
Applicable bore
Auto switch model C HW H H' T T' Z
size (mm) -X
D-A3C-4, D-A44C-4 40 44 69 58 (67.5) 50.5 (60) 7.5 6.5
M5 x 0.8 x 16
D-A3C-5, D-A44C-5 50 52 77 59 (68.5) 51.5 (61) 8.5 6.5
D-A3C-6, D-A44C-6 63 64 91 61.5 (71) 53 (62.5) 10.5 7.5 M5 x 0.8 x 20
20-
D-A3C-8, D-A44C-8 80 78 107 65 (74.5) 54.5 (64) 12.5 9.5
D-A3C-10, D-A44C-10 100 92 121 68 (77.5) 57.5 (67) 15.5 9.5
M5 x 0.8 x 25
Data
Dimensions ∗ ( ): Denotes the values of D-A44C

D-A3C 2-M5 x 0.8 x 12 D-A44C


Hexagon socket head cap bolt 2-M5 x 0.8 x 12
Tightening gland Hexagon socket head cap bolt
Tightening gland

G 1/2 G 1/2
Applicable cable O.D. Hexagon socket Applicable cable O.D.
Hexagon socket ø6.8 to ø9.6
head cap bolt head cap bolt ø6.8 to ø11.5

Indicator light
Most sensitive position
Most sensitive position

6-16-19
Reed Switch
Direct Mounting Style
D-A90(V)/D-A93(V)/D-A96(V) For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller
D-A90, D-A90V (Without indicator light)
Auto switch model D-A90, D-A90V
Applicable load IC circuit, Relay, PLC
Load voltage 24 V AC
DC or less 48 V AC
DC or less 100 V AC
DC or less

Maximum load current 50 mA 40 mA 20 mA


Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
D-A93, D-A93V, D-A96, D-A96V (With indicator light)
Caution Auto switch model D-A93, D-A93V D-A96, D-A96V
Precautions Applicable load Relay, PLC IC circuit
1. Fix the switch with appropriate screw Load voltage 24 VDC 100 VAC 4 to 8 VDC
installed on the switch body. If using other (3)
Load current range and
screws, switch may be damaged. 5 to 40 mA 5 to 20 mA 20 mA
Maximum load current
Contact protection circuit None
D-A93 —— 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)
Internal voltage drop 0.8 V or less
Auto Switch Internal Circuit D-A93V —— 2.7 V or less
Colors of lead wire inside ( ) are the Indicator light Red LED lights when ON.
ones before conformed to IEC standard. • Lead wire
D-A90(V)/D-A93(V)—Oil resistant vinyl heavy-duty cord, ø2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m
D-A90V D-A96(V)—Oil resistant vinyl heavy-duty cord, ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Reed switch

Contact OUT(±) Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
protection Brown
box
light will not be possible where the output signal is less than 2.5 mA. However, there is no
 problem in terms of contact output, when an output signal exceeds 1 mA or more.
CD-P11
±
CD-P12 OUT ( )
Blue Weight
(g)
D-A93V Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V
LED Brown (Red) Lead wire length: 0.5 m 6 6 6 6 8 8
Contact OUT (+)
Resistor
protection Brown Lead wire length: 3 m 30 30 30 30 41 41
Reed switch

Zener diode box



CD-P11
CD-P12
Dimensions
OUT (–)
Blue (Black) Blue D-A90, D-A93, D-A96

D-A96V
DC (+)
LED Brown
(+) Indicator light
Resistor
Load M2.5 x 4l D-A90 without indicator light
Reed switch

Reverse OUT DC Slotted set screw


current Black power supply
prevention
diode
(–)
DC (–)
Blue

Note 1) Operating load is an induction load. Most sensitive


Note 2) Wiring to the load is 5 m or longer. position
Note 3) Load voltage is 100 VAC. ( ): dimensions for D-A93.
Use the contact protection box in any of the D-A90V, D-A93V, D-A96V
above listed situations. The contact point life may M2.5 x 4l Slotted set screw
decrease. (Refer to page 6-16-7 for contact
protection box.)

Indicator light
D-A90V without indicator light

6-16-20 Most sensitive position


Reed Switch
Direct Mounting Style
D-90/D-97 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Lead wire: Parallel cord PLC: Abbreviation of Programmable Logic Controller
D-90 (Without indicator light)
Auto switch model D-90
CJ1
Applicable load Relay, IC circuit, PLC

Load voltage
5 VAC 12 VAC 24 VAC CJP
5 VDC 12 VDC 24 VDC
Max. load current 50 mA CJ2
Internal resistance 1 or less (Including lead wire length of 3 m)
D-97 (With indicator light) CM2
Auto switch model D-97 CG1
Applicable load Relay, PLC
Load voltage 24 VDC MB
Load current range (3) 5 to 40 mA
Internal voltage drop 2.4 V or less MB1
Indicator light Red LED lights when ON.
• Lead wire — Vinyl parallel cord, 0.2 mm2, 2 cores, 0.5 m
CA2
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7. CS1
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
Auto Switch Internal Circuit there is no problem in terms of contact output, when an output signal exceeds 1 mA or C76
more.
D-90
OUT (±)
C85
OUT (±)
Contact Weight
Reed switch

Brown
protection
box
C95
CD-P11  (g)
CD-P12
CP95
±
OUT ( ) ±
OUT ( ) Auto switch model D-90 D-97
Black line Blue
0.5 5 5
Lead wire length
3 23 23 NCM
(m)
D-97 Contact protection box 5 37 37
CD-P12 NCA
Choke coil
OUT (+)
OUT (+) Dimensions D-
Reed switch

Brown
Zener
diode Zener
diode

OUT (–)
D-90 -X
OUT (–)
LED Resistor Black line Blue
Most sensitive position 20-
Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer. Data
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.) D-97 Indicator light

(Negative) polarity indication


Black line

Most sensitive position

6-16-21
Reed Switch
Direct Mounting Style
D-90A/D-93A For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Lead wire: Heavy-duty cord PLC: Abbreviation of Programmable Logic Controller
D-90A (Without indicator light)
Auto switch model D-90A
Applicable load Relay, IC circuit, PLC

Load voltage 5 VAC 24 VAC 24 VAC 100 VAC


5 VDC 12 VDC 24 VDC 100 VDC
Max. load current 50 mA 20 mA
Internal resistance 1or less (Including lead wire length of 3 m)
D-93A (With indicator light)
Auto switch model D-93A
Applicable load Relay, PLC
Load voltage 24 VDC 100 VAC
Load current range (3) 5 to 40 mA 5 to 20 mA
Internal voltage drop 2.4 V or less
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
Auto Switch Internal Circuit there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
D-90A

OUT(±) Weight
Reed switch

Contact
protection Brown
box  (g)
CD-P11
CD-P12 OUT( )±
Auto switch model D-90A D-93A
Blue
0.5 9 9
Lead wire length
(m) 3 47 47
D-93A 5 77 77
Brown
OUT (+)
Contact
Reed switch

Brown
Zener diode
protection
box
Dimensions
CD-P11 
CD-P12 D-90A
OUT (–)
LED Resistor Blue Blue

Note 1) Operating load is an induction load. Most sensitive position


Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.) D-93A Indicator light

Most sensitive position

6-16-22
Reed Switch
Direct Mounting Style
D-Z73/D-Z76/D-Z80 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-Z7 (With indicator light)
Auto switch model D-Z73 D-Z76 CJ1
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC CJP
Max. load current and load current range (3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None CJ2
Internal voltage drop ≤ 2.4 V (to 20 mA)/≤ 3 V (to 40 mA) 0.8 V or less
Indicator light Red LED lights when ON.
CM2
D-Z8 (Without indicator light) CG1
Auto switch model D-Z80
Applicable load Relay, PLC, IC circuit MB
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Maximum load current 50 mA 40 mA 20 mA MB1
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
CA2
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m (For only D-Z73, ø2.7, 0.18 mm2, 2 cores) CS1
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Auto Switch Internal Circuit Note 2) Regarding the lead wire length, refer to page 6-16-7. C76
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
D-Z73 indicator light will not be possible where the output signal is less than 2.5 mA. However,
LED
there is no problem in terms of contact output, when an output signal exceeds 1 mA or C85
Brown more.
OUT (+)
Resistor Contact
protection
Brown
C95
Reed switch

Zener diode box


CD-P11 
CD-P12
OUT (–)
Weight CP95
Blue Blue
(g)
NCM
D-Z76 Auto switch model D-Z73 D-Z76 D-Z80

LED
DC (+) 0.5 7 10 9 NCA
Brown Lead wire length
(+) 3 31 55 49
Resistor (m)
Load 5 50 — — D-
Reed switch

Reverse OUT DC power supply


current Black
prevention
diode
(–)
-X
DC (–)
Blue
Dimensions
20-
D-Z73 D-Z76, Z80
D-Z80
Indicator light
Data
Switch mounting screw Switch mounting screw
D-Z80 without indicator light
Slotted set screw 30.5 27.6
Reed switch

Contact OUT(±) Slotted set screw


protection Brown (M2.5 x 4L) 2.3 (M2.5 x 4L) 2.5
box 
CD-P11
6.2
6.2

±
CD-P12 OUT ( )
Blue
Indicator light

Note 1) Operating load is an induction load.


5.5

5.7

Note 2) Wiring to the load is 5 m or longer. Most sensitive


ø2.7

Most sensitive
Note 3) Load voltage is 100 VAC. 12.5 position 12.5 position
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact
protection box.)

6-16-23
Reed Switch
Direct Mounting Style
D-E73A/D-E76A/D-E80A For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-E7A (With indicator light)
Auto switch model D-E73A D-E76A
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC
Max. load current and load current range (3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less 0.8 V or less
Indicator light Red LED lights when ON.
D-E80A (Without indicator light)
Auto switch model D-E80A
Applicable load Relay, PLC, IC circuit
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Maximum load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 8-30-7.
Auto Switch Internal Circuit Note 2) Regarding the lead wire length, refer to page 8-30-7.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
D-E73A indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
LED Brown
OUT (+) more.
Resistor Contact Brown
protection
Reed switch

box 
Zener diode
CD-P11 Weight
CD-P12
OUT (–)
Blue Blue
(g)
Auto switch model D-E73A D-E76A D-E80A
D-E76A 0.5 10 11 10
Lead wire length
DC (+) 3 47 55 47
LED Brown (m)
(+) 5 — — —
Resistor
Reed switch

Load
Reverse OUT DC power supply
current
prevention
Black Dimensions
diode
(–)
DC (–)
Blue

D-E80A Indicator light


D-E80A without indicator light
OUT (±)
Reed switch

Contact
protection Brown
box 
CD-P11
OUT ( ) ±
CD-P12
Blue

Note 1) Operating load is an induction load. ø2.7 through


Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Most sensitive position
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 8-30-7 for contact
protection box.)

8-30-18
Reed Switch
Direct Mounting Style
D-R73/D-R80 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller
D-R73 (With indicator light) D-R80 (Without indicator light)
Auto switch model D-R731, D-R732 D-R801, D-R802
Applicable load Relay, PLC Relay, IC circuit, PLC
AC AC AC
Load voltage 100 VAC 24 VDC 24 V DC or less 48 V DC 100 V DC
Max. load current and
5 to 20 mA 5 to 40 mA 50 mA 40 mA 20 mA
load current range
Contact protection circuit None None
Internal voltage drop 2.4 V or less 0
Indicator light Red LED lights when ON. None
• Lead wire — Oil resistant vinyl heavy-duty cord 0.2 mm2, 2-wire (Brown, Blue) 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 11-11-5.
Note 2) Regarding the lead wire length, refer to page 11-11-5.

D-2 D-1

Dimensions
D-R731: Right-hand mounting D-R732: Left-hand mounting
Left-hand mounting Right-hand mounting
Most sensitive position

Auto Switch Internal Circuit


D-R731, D-R732

LED Brown
OUT (+)
Resistor Contact
protection Brown
Reed switch

Zener box
CD-P11 앑
diode
CD-P12
OUT (–) Most sensitive position
Blue Blue

D-R801, D-R802
D-R801: Right-hand mounting D-R802: Left-hand mounting
Contact
Reed switch

OUT (±)
protection Brown
box 앑
CD-P11 Arm
Most sensitive position
CD-P12 OUT (±)
Blue

Most sensitive position


Arm

11-11-14
Reed Switch
Direct Mounting Style
D-R73 C/D-R80 C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Connector Auto Switch Specifications


Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller
D-R73C (With indicator light) D-R80C (Without indicator light)
Auto switch model.
CRB2
D-R731C, D-R732C D-R801C, D-R802C
Applicable load Relay, PLC Relay, PLC
AC
CRBU2
Load voltage 24 VDC 24 V DC or less
Load current range 5 to 40 mA 50 mA CRB1
Contact protection circuit None None
Internal voltage drop 2.4 V or less 0 MSU
Indicator light Red LED lights when ON. None
• Lead wire — Oil resistant vinyl heavy-duty cord ø3.4, 0.2 mm2
CRJ
Note 1) Regarding the common specifications of the reed switches, refer to page 11-11-5.
Caution Note 2) Regarding the lead wire length, refer to page 11-11-5. CRA1
Precautions
Confirm that there is no looseness after wiring. Dimensions CRQ2
The looseness will decrease water resistance.
D-R731C: Right-hand mounting D-R732C: Left-hand mounting MSQ

Most sensitive position


MRQ
D-C D-C
D-
20-

Left-hand mounting Right-hand mounting

Most sensitive position


Auto Switch Internal Circuit
D-R731, D-R732
LED Brown
OUT (+)
Resistor Contact
Brown
protection
Reed switch

Zener box
~
D-R801C: Right-hand mounting D-R802C: Left-hand mounting
diode CD-P11
CD-P12
OUT (–)
Blue Blue
Most sensitive position

D-R801, D-R802
Reed switch

Contact OUT (±)


protection Brown
box ~
CD-P11
CD-P12 OUT (±) Most sensitive position
Blue

Precautions
Be sure to read before handling.
Refer to pages 11-13-3 to 4 for
Safety Instructions and Common
Precautions on the products
mentioned in this catalog, and refer
to pages 11-1-4 to 6 for
Precautions on every series.

11-11-15
Solid State Switch
Band Mounting Style
D-H7A1/D-H7A2/D-H7B For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-H7 (With indicator light)
Auto switch model D-H7A1 D-H7A2 D-H7B
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.

Auto Switch Internal Circuit


D-H7A1 Weight
DC (+) (g)
Brown
Auto switch model D-H7A1 D-H7A2 D-H7B
Main circuit

0.5 13 13 11
of switch

OUT
Lead wire length
Black 3 57 57 50
(m)
5 92 92 81

DC (–)
Blue

Dimensions
D-H7A2

DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue
Indicator light
D-H7B ø3.5 mounting hole
OUT (+)
Brown
Main circuit
of switch

OUT (–) Most sensitive position


Blue

8-30-22
Solid State Switch
Band Mounting Style
D-G59/D-G5P/D-K59 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-H7l
D-G5 , D-K59
(with (Withlight)
indicator indicator light)
Auto switch model D-G59 D-G5P D-K59 MX
Wiring type 3-wire 2-wire
Output type NPN PNP — MTS
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — MY
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
CY
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
MG
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current) CX
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON. D-
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m -X
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.
20-
Auto Switch Internal Circuit
D-G59 Weight Data
DC (+) (g)
Brown
Auto switch model D-G59 D-G5P D-K59
Main circuit

0.5 20 20 18
of switch

OUT Lead wire length


Black (m) 3 78 78 68
5 124 124 108

DC (–)
Blue
Dimensions
D-G5P
DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue Indicator light

ø3.5 mounting hole


D-K59
OUT (+)
Brown
Main circuit
of switch

Most sensitive position

OUT (–)
Blue

8-30-23
Solid State Switch
Band Mounting Style
D-H7C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Connector Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-H7C (With indicator light)
Auto switch model D-H7C
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
Caution Indicator light Red LED lights when ON.
Precautions
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
1. Confirm that the connector is appropriately Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
tightened. If tightened insufficiently, the Note 2) Regarding the lead wire length, refer to page 8-30-7.
waterproof performance will deteriorate.
2. Refer to page 8-30-55 for the details.

Auto Switch Internal Circuit Weight


D-G59 (g)
Auto switch model D-H7C
OUT (+)
Brown 0.5 15
Lead wire length
3 54
Main circuit

(m)
of switch

5 85

OUT (–)
Blue
Dimensions

Indicator light

ø3.5 mounting hole

Most sensitive position

8-30-24
Solid State Switch
Band Mounting Style
D-G39/D-K39 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-G39, D-K39 (With indicator light)
Auto switch model D-G39 D-K39 CJ1
Wiring type 3-wire 2-wire
Output type NPN — CJP
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — CJ2
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
CM2
Load current 40 mA or less 5 to 40 mA
1.5 V or less
CG1
Internal voltage drop (0.8 V or less 4 V or less
Caution at 10 mA of load current) MB
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Precautions Indicator light Red LED lights when ON. MB1
1. Use cable whose O.D. is within the size in Note) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
the figure to maintain water resistant CA2
performance.
2. After wiring, confirm that tightening gland
and all screws are tightened. CS1
C76
Auto Switch Internal Circuit Weight C85
D-G39 (g)
C95
DC (+)
Auto switch model D-G39 D-K39
Terminal no. 1 Lead wire None 116 116 CP95
Main circuit
of switch

OUT
Terminal no. 2 NCM
NCA
DC (–)
Terminal no. 3 Dimensions D-
Tightening gland
D-K39 -X
OUT (+)
Terminal no. 1 20-
Main circuit
of switch

G 1/2
(Applicable cable O.D.
Data
ø6.8 to ø9.6)

OUT (–)
Terminal no. 2

Indicator light
Most sensitive position

6-16-31
Solid State Switch
Band Mounting Style
D-G39A/D-K39A For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-G39A, D-K39A
Auto switch model D-G39A D-K39A
Wiring type 3-wire 2-wire
Output type NPN —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA of load current)
Caution Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Precautions Indicator light Red LED lights when ON.
1. Use cable whose O.D. is within the size in
Note) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
the figure to maintain water resistant
performance.
2. After wiring, confirm that tightening gland
and all screws are tightened.

Auto Switch Internal Circuit Weight


D-G39A (g)

DC (+) Auto switch model D-G39A D-K39A


Terminal no. 1
Lead wire None 110 110
Main circuit
of switch

OUT
Terminal no. 2

DC (–)
Terminal no. 3 Dimensions
G 1/2
D-K39A
(Applicable cable O.D.
ø6.8 to ø9.6)
OUT (+)
Terminal no. 1
Main circuit
of switch

Tightening gland

OUT (–)
Terminal no. 2

Indicator light Most sensitive position

6-16-32
Solid State Switch
Rail Mounting Style
D-F79/D-F7P/D-J79 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-F7, D-J79 (With indicator light)
Auto switch model D-F79 D-F7P D-J79
2-wire
MX
Wiring type 3-wire
Output type NPN PNP — MTS
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — MY
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) CY
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less MG
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
CX
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON. D-
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m -X
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.
20-
Data
Auto Switch Internal Circuit Weight
D-F79 (g)
Auto switch model D-F79 D-F7P D-J79
DC (+)
Brown 0.5 13 13 11
Lead wire length
3 57 57 50
Main circuit

(m)
of switch

OUT
Black 5 92 92 81

DC (–)
Blue Dimensions
ø3.5 mounting hole
D-F7P Indicator light
DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-J79
OUT (+) Most sensitive position
Brown
Main circuit
of switch

OUT (–)
Blue

8-30-25
Solid State Switch
Rail Mounting Style
D-F7NV/D-F7PV/D-F7BV For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Electrical entry: Perpendicular PLC: Abbreviation of Programmable Logic Controller
D-F7V (With indicator light)
Auto switch model D-F7NV D-F7PV D-F7BV
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.

Auto Switch Internal Circuit Weight


D-F7NV (g)
Auto switch model D-F7NV D-F7PV D-F7BV
DC (+)
Brown 0.5 13 13 11
Lead wire length
(m) 3 57 57 50
Main circuit
of switch

OUT
Black
5 92 92 81

DC (–)
Blue Dimensions
ø3.5 mounting hole
D-F7PV Indicator light

DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-F7BV
OUT (+) Most sensitive position
Brown
Main circuit
of switch

OUT (–)
Blue

8-30-26
Solid State Switch
Rail Mounting Style
D-J79C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Connector Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller

D-J79C
Auto switch model D-J79C
MX
Wiring type 2-wire
Output type — MTS
Applicable load 24 VDC Relay, PLC
Power supply voltage —
MY
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
CY
Load current 5 to 40 mA
Internal voltage drop 4 V or less
MG
Leakage current 0.8 mA or less at 24 VDC
Caution Indicator light Red LED lights when ON.
CX
Precautions • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
1. Confirm that the connector is appropriately Note 2) Regarding the lead wire length, refer to page 8-30-7. D-
tightened. If tightened insufficiently, the
waterproof performance will deteriorate. -X
2. Refer to page 8-30-55 for the details.
20-
Data
Auto Switch Internal Circuit Weight
D-J79C (g)
Auto switch model D-J79C
OUT (+)
Brown 0.5 13
Lead wire length
3 52
Main circuit

(m)
of switch

5 83

OUT (–)
Blue Dimensions

ø3.2 mounting hole

Indicator light

Most sensitive position

8-30-27
Solid State Switch
Tie-rod Mounting Style
D-F59/D-F5P/D-J59/D-J51 For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller

D-F5, D-J5
Auto switch model D-F59 D-F5P D-J59 D-J51
Wiring type 3-wire 2-wire
Output type NPN PNP — —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC AC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — —
Current consumption 10 mA or less — —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) 80 to 260 VAC
Auto Switch Internal Circuit Load current 40 mA or less 80 mA or less 5 to 40 mA 5 to 80 mA
D-F59 1.5 V or less
Internal voltage drop (0.8 V or less at 0.8 V or less 4 V or less 14 V or less
10 mA load current)
DC (+)
Brown 0.8 mA or less 1 mA or less at 100 VDC
Leakage current 100 µA or less at 24 VDC
at 24 VDC 1.5 mA or less at 200 VDC
Main circuit
of switch

OUT Indicator light Red LED lights when ON.


Black
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
DC (–)
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Blue

D-F5P
Weight
DC (+)
Brown (g)
Auto switch model D-F59 D-F5P D-J59 D-J51
Main circuit
of switch

0.5 23 23 21 21
OUT Lead wire length
Black (m) 3 81 81 71 71
5 127 127 111 111
DC (–)
Blue

D-J59 Dimensions
OUT (+)
Brown
Mounting hole
Main circuit
of switch

Indicator light

OUT (–)
Blue

D-J51
Main circuit
of switch

OUT
Brown
OUT
Blue

Most sensitive position

6-16-36
Solid State Switch
Tie-rod Mounting Style
D-G39C/D-K39C For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Terminal conduit Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-G39C, D-K39C
Auto switch model D-G39C D-K39C CJ1
Wiring 3-wire 2-wire
Output NPN — CJP
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC) — CJ2
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
CM2
Load voltage 40 mA or less 5 to 40 mA
CG1
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
Caution at 10 mA of load current) MB
Precautions Current leakage 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
1. Use cable whose O.D. is within the size in Indicator light Red LED lights when ON. MB1
the figure to maintain water resistant Note) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
performance. CA2
2. After wiring, confirm that tightening gland
and all screws are tightened.
Weight
(g)
CS1
Auto switch model D-G39C D-K39C C76
40 162 162
Auto Switch Internal Circuit 50 166 166 C85
Applicable bore size
D-G39C 63 184 184
(mm)
80 210 210 C95
DC (+) 100 232 232
Terminal no. 1
CP95
Main circuit

Dimensions
of switch

OUT
Terminal no. 2 NCM
2-M5 x 0.8 x 12
Hexagon socket head cap bolt NCA
DC (–)
Terminal no. 3
D-
D-K39C -X
Tightening gland
OUT (+)
Terminal no. 1 Hexagon socket 20-
head cap bolt
Main circuit
of switch

G 1/2
(Applicable cable O.D.
Data
ø6.8 to ø9.6)

OUT (–)
Terminal no. 2

Indicator light
Most sensitive position

Dimensions
Applicable bore
Auto switch model C HW H H´ T T´ Z
size (mm)
D-G39C-4, D-K39C-4 40 44 69 57 49.5 7.5 6.5
M5 x 0.8 x 16
D-G39C-5, D-K39C-5 50 52 77 58 50.5 8.5 6.5
D-G39C-6, D-K39C-6 63 64 91 60.5 52 10.5 7.5 M5 x 0.8 x 20
D-G39C-8, D-K39C-8 80 78 107 64 53.5 12.5 9.5
M5 x 0.8 x 25
D-G39C-10, D-K39C-10 100 92 121 67 56.5 15.5 9.5

6-16-37
Solid State Switch
Direct Mounting Style
D-M9N(V)/D-M9P(V)/D-M9B(V) For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


• Lower load current PLC: Abbreviation of Programmable Logic Controller

• Lead free solder D-M9, D-M9V (With indicator light)


• Using UL certified (style Auto switch model D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
2844) lead wire
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø2.7 x 3.2 ellipse 0.15 mm2, 2 cores (D-M9B), 3
cores (D-M9N, D-M9P)
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.
Auto Switch Internal Circuit
Weight (g)
D-M9N, D-M9NV
DC (+) Auto switch model D-M9N(V) D-M9P(V) D-M9B(V)
Brown
0.5 8 8 7
Lead wire length
Main circuit
of switch

OUT (m) 3 41 41 38
Black
5 68 68 63

DC (–)
Dimensions
Blue
D-M9 D-M9V

500 (3000) (5000)


M2.5 x 4l slotted set screw
D-M9P, D-M9PV M2.5 x 4l Indicator light
Indicator light
Slotted set screw 8
DC (+) 2.6 2 3.2
Brown 4.6
4
2.7
2.8
Main circuit

6 Most sensitive position


4

2.8
of switch

22 500 (3000) 20 2.7


OUT
3.2

Black
2.6

DC (–)
9.5

Blue
6 Most sensitive position
22 500 (3000)
4

D-M9B, D-M9BV
OUT (+)
Brown Precautions
Main circuit

Be sure to read before handling. Please contact SMC when using


of switch

beyond specifications.

OUT (–)
Caution on Handling
Blue
Caution
Operating range shortened, compared to conventional • Over-current protection is not equipped with this product series. When it is
types. wired incorrectly or a load is short-circuited, a switch may be damaged or
When replacing conventional types, dependant upon burned.
application, the shortened operating range may cause auto • In the event of stripping cable sheath, use caution for the stripping direction.
switch imperceptive. Its insulation may be torn or damaged, depending on the direction.
• When the range of stroke is wider than the operating • Below is given as the recommended tool.
range. Example) Stamping, press-fitting, clamping, etc.
• When used to detect intermediate position. (Detection Maker Product’s name Part no.
output time is shortened.)
Note) Please consult with SMC regarding details of VESSEL Co., Inc. Wirestripper No 3000G
operation range by each actuator. Tokyo Ideal Co., Ltd. Stripmaster 45-089
Since short circuit protection circuit is not built-in, the auto ∗ As for 2-wire, a stripper for round shape cord (ø2.0) is usable.
switch will be immediately damaged when the load is short- • Fix the switch with appropriate screw installed on the switch body. If using
circuited. Be careful not to exchange the power cable other screws, switch may be damaged.
(brown) with the output cable (black).

8-30-28
Normally Closed Solid State Switch
Direct Mounting Style
D-F9G/D-F9H For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller

D-F9G, D-F9H (With indicator light)


Auto switch model D-F9G D-F9H CUJ
Wiring type 3-wire
Output type NPN PNP CU
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) CQS
Current consumption 10 mA or less
CQM
Load voltage 28 VDC or less —

Caution Load current 40 mA or less 80 mA or less CQ2


1.5 V or less
0.8 V or less
Precautions Internal voltage drop
(0.8 V or less at 10 mA load current) RQ
Fix the switch with appropriate screw installed Leakage current 100 µA or less at 24 VDC
on the switch body. If using other screws, switch
may be damaged. Indicator light Red LED lights when detecting nothing. MU
• Lead wire — Oil resistant vinyl heavy-duty cord, ø2.7, 0.15 mm2, 3 cores (Brown, Black, Blue) 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 7-9-7. D-
Note 2) Regarding the lead wire length, refer to page 7-9-7.
-X
20-
Auto Switch Internal Circuit Weight Data
D-F9G (g)
Auto switch model D-F9G D-F9H
DC (+)
Brown 0.5 7 7
Lead wire length
3 37 37
Main circuit

(m)
of switch

OUT
5 61 61
Black

DC (–)
Blue Dimensions
Mounting screw M2.5 x 4l
D-F9H Slotted set screw

DC (+) 2 Indicator light


Brown
Main circuit
of switch

NC

SMC D-F9H

OUT 22
ø2.7
2.8

Black

DC (–)
Blue
2.6

6 Most sensitive position

7-9-23
Solid State Switch
Direct Mounting Style
D-F8N/D-F8P/D-F8B For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
Auto switch model D-F8N D-F8P D-F8B
Electrical entry direction Perpendicular Perpendicular Perpendicular MX
Wiring type 3-wire 2-wire
Output type NPN PNP — MTS
Applicable load IC circuit, 24 VDC Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — MY
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
CY
Load current 40 mA or less 80 mA or less 2.5 to 40 mA
1.5 V or less
MG
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
Caution at 10 mA load current) CX
Precautions Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC

Fix the switch with appropriate screw installed Indicator light Red LED lights when ON. D-
on the switch body. If using other screws, switch • Lead wire ——— Oil resistant vinyl heavy-duty cord, ø2.7, 0.5 m
may be damaged. D-F8N, D-F8P 0.15 mm2 x 3 cores (Brown, Black, Blue) -X
D-F8B 0.18 mm2 x 2 cores (Brown, Blue)
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7. 20-

Auto Switch Internal Circuit Weight Data


D-F8N (g)

DC (+)
Auto switch model D-F8N D-F8P D-F8B
Brown 0.5 7 7 7
Lead wire length
3 32
Main circuit

(m) 32 32
of switch

OUT
Black 5 52 52 52

DC (–)
Blue Dimensions
D-F8N, D-F8P, D-F8B
D-F8P
Mounting screw M2.5 x 4l
DC (+)
Brown Slotted set screw
4.3
Indicator light
Main circuit

2
of switch

ø2.7
OUT
Black
10
2.8

4.6

DC (–)
Blue
3

D-F8B
10.9

OUT (+)
4
Brown
3.1

8 Most sensitive position


Main circuit
of switch

OUT (–)
Blue

8-30-29
Solid State Switch
Direct Mounting Style
D-Y59 BA/D-Y69 BA /D-Y7P(V) For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-Y5, D-Y6, D-Y7P, D-Y7PV (With indicator light)
Auto switch model D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.
Auto Switch Internal Circuit
D-Y59A, D-Y69A
Weight
DC (+)
Brown (g)
Main circuit

Auto switch model D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V)


of switch

OUT
Black 0.5 9 10 10
Lead wire length
(m) 3 50 53 53
5 83 87 87
DC (–)
Blue

D-Y7P, D-Y7PV Dimensions


DC (+)
Brown
D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B
Main circuit

Mounting screw M2.5 x 4l


of switch

Mounting screw M2.5 x 4l Slotted set screw


OUT
Black
Slotted set screw Indicator light
2.5
Indicator light
DC (–) 2.5
6.2

SMC

Blue
6.2

SMC

27.3
D-Y59B, D-Y69B
ø3.4

29
ø3.4
OUT (+)
Brown
Main circuit

8.5
of switch

12.5 Most sensitive position


12.5 Most sensitive position

OUT (–)
Blue

8-30-30
Normally Closed Solid State Switch
Direct Mounting Style
D-Y7G/D-Y7H For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-Y7G, D-Y7H (With indicator light)
Auto switch model D-Y7G D-Y7H
Wiring type 3-wire
Output type NPN PNP
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less —
Load current 40 mA or less 80 mA or less
1.5 V or less
Internal voltage drop 0.8 V or less
(0.8 V or less at 10 mA load current)
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED lights when detecting nothing.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.

Auto Switch Internal Circuit Weight


D-Y7G (g)
DC (+) Auto switch model D-Y7G D-Y7H
Brown
0.5 10 10
Lead wire length
Main circuit

3 53 53
of switch

OUT (m)
Black 5 87 87

DC (–)
Blue Dimensions
Mounting screw M2.5 x 4l
D-Y7H
Slotted set screw
DC (+)
ø3.4

Indicator light
Brown 2.5
Main circuit
of switch

SMC
6.2

NC
OUT
Black
29
DC (–)
Blue
5

D-Y7G

12.5 Most sensitive position

8-30-32
Solid State Switch
Direct Mounting Style
D-M5N/D-M5P/D-M5B For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-M5 (With indicator light)
Auto switch model D-M5N D-M5P D-M5B RE BA
Wiring type 3-wire 2-wire
Output type NPN PNP — REC
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — CX
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
CY
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
MQ MQ
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current) RHC
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON. MK(2)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m RS QG
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.
RS AH
RZQ
Auto Switch Internal Circuit Weight MI WS
D-M5N (g)
CEP1
Auto switch model D-M5N D-M5P D-M5B
DC (+)
Brown
Lead wire length
0.5 16 16 14 CE1
3 60 60 53
Main circuit

(m)
of switch

OUT
Black 5 95 95 84 CE2
ML2B
DC (–)
Blue Dimensions C GJ 5-S
Indicator light
D-M5P CV
DC (+)
Brown MVGQ
Main circuit
of switch

CC
OUT
Black
RB
ø3 mounting hole
DC (–)
Blue J
D-M5B D-
OUT (+)
Brown
Most sensitive position
-X
Main circuit
of switch

20-
Data
OUT (–)
Blue

10-20-39
Solid State Switch
Direct Mounting Style
D-S99(V)/D-S9P(V)/D-T99(V)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller

2-wire D-S99(V)/D-S9P(V)/D-T99(V) (With indicator light)


D-S991 D-S99V1 D-S9P1 D-S9PV1 D-T991 D-T99V1
3-wire Auto switch model
D-S992 D-S99V2 D-S9P2 D-S9PV2 D-T992 D-T99V2
Electrical entry In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
D-T99 Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
D-S99 Current consumption 10 mA or less
D-S9P Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at load current 10 mA)
D-1 D-2 Leakage current 100 애A or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord ø3.4, 0.2 mm2, 3-wire (Brown, Black, Blue),
2-wire (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 11-11-5.
Note 2) Regarding the lead wire length, refer to page 11-11-5.
Right-hand mounting Left-hand mounting
Dimensions
D-V1 D-V2 D-S991: Right-hand mounting D-S992: Left-hand mounting
D-S9P1: D-S9P2:
D-T991: D-T992:

Right-hand mounting Left-hand mounting ø3.4 Mounting hole

Auto Switch Internal Circuit


ø3.4

ø3.4
D-S99(V)1, D-S99(V)2
ø3.4
DC (+) Mounting hole
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-S9P(V)1, D-S9P(V)2
DC (+) D-S99V1: Right-hand mounting D-S99V2: Left-hand mounting
Brown
D-S9PV1: D-S9PV2:
D-T99V1: D-T99V2:
Main circuit
of switch

ø3.4
Mounting hole
OUT
Black

DC (–)
Blue

D-T99(V)1, D-T99(V)2 ø3.4


OUT (+) Mounting hole
Brown
Main circuit
of switch

OUT (–)
Blue

11-11-22
Solid State Switch
Direct Mounting Style
D-S79/D-S7P/D-T79(C)
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet, Connector Auto Switch Specifications


Electrical Entry: In-line PLC: Abbreviation of Programmable Logic Controller
D-S79/D-T79 (With indicator light)
Auto switch model D-S791, D-S792 D-S7P1, D-S7P2 D-T791, D-T792, D-T791C, D-T792C
CRB2
Wiring type 3-wire 2-wire
CRBU2
Output type NPN PNP
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC CRB1
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less MSU
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
CRJ
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less CRA1
at 10 mA)
Leakage current 100 애A or less at 24 VDC 0.8 mA or less at 24 VDC CRQ2
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord ø3.4, 0.2 mm2, 3-wire (Brown, Black, Blue), MSQ
D-2 D-1 2-wire (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 11-11-5.
Note 2) Regarding the lead wire length, refer to page 11-11-5. MRQ
Dimensions D-
D-S791: Right-hand mounting D-S792: Left-hand mounting 20-
Left-hand mounting Right-hand mounting D-S7P1: D-S7P2:
D-T791: D-T792:
Auto Switch Internal Circuit
Most sensitive position
D-S791, D-S792
DC (+)
Brown
Main circuit
of switch

OUT
Black
Most sensitive position

DC (–)
Blue

D-S7P1, D-S7P2 D-T791C: Right-hand mounting D-T792C: Left-hand mounting


DC (+)
Brown
Most sensitive position
Main circuit
of switch

OUT
Black

DC (–) D-T792C: Left hand mounting


Blue

D-T791(C), D-T792(C) Most sensitive position

OUT (+)
Brown
Main circuit
of switch

OUT (–)
Blue

11-11-23
6-15-36
2-color Indication Type Reed Switch
Band Mounting Style
D-B59W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-B59W (With indicator light)
of the light.
Auto switch model D-B59W
(Red → Green ← Red)
Applicable load Relay, PLC
Load voltage 24 VDC
Load current range (3) 5 to 40 mA
Contact protection circuit Built-in
Internal voltage drop 4 V or less
Operating position······Red LED lights when ON.
Indicator light
Optimum operating position······Green LED lights when ON.

• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Auto Switch Internal Circuit more.

D-B59W
Choke coil Weight
OUT (+)
Brown (g)
Reed switch
Zener diode Auto switch model D-B59W
Main circuit
of switch

0.5 20
Lead wire length
LED 3 76
(m)
OUT (–) 5 —
Blue

Indicator light/Display method


Dimensions
Operating range

Indication
Red Green Red

Optimum operating position

Indicator light

Most sensitive position

6-16-24
2-color Indication Type with Diagnostic Output
Solid State Switch: Band Mounting Style
D-H7NF For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Since the output signal can be PLC: Abbreviation of Programmable Logic Controller
detected in an unsteady detecting D-H7NF (With indicator light)
area, the difference of detecting Auto switch model D-H7NF MX
position can be confirmed by the Wiring 4-wire
side of PLC (Programmable Logic Output NPN MTS
Controller). Diagnostic output Normal operation
Applicable load IC circuit, Relay, PLC MY
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption
CY
10 mA or less
Load voltage 28 VDC or less MG
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at each output 5 mA) CX
Current leakage 100 µA or less at 24 VDC
Operating position······Red LED lights when ON.
D-
Indicator light
Optimum operating position······Green LED lights when ON.
Auto Switch Internal Circuit • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 4 cores (Brown, Black, Orange,
-X
Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7. 20-
Note 2) Regarding the lead wire length, refer to page 8-30-7.
DC (+)
Brown
Weight Data
OUT (Normal output)
Black
(g)
Main circuit
of switch

Diagnosis OUT
(Diagnostic output) Auto switch model D-H7NF
Orange
0.5 13
Lead wire length
DC (–) (m) 3 56
Blue
5 90

Diagnostic Output Operation


The diagnostic signal is output ON
within unsteady detecting
OFF Red Green Red OFF Red
area (where indicator light is Indicator light
Red), and the diagnostic
output becomes OFF when
the detecting position remains OUT
(Normal output)
within the optimum operating
position (where indicator is
Green). When the detecting Diagnosis OUT
position is not adjusted, the (Diagnostic output)
diagnostic output becomes
ON.

Dimensions
ø3.4

Indicator light

ø3.5 mounting hole

Most sensitive position

8-30-39
2-color Indication Type with Diagnostic Output
Solid State Switch: Band Mounting Style
D-G59F For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Since the output signal can be PLC: Abbreviation of Programmable Logic Controller
detected in an unsteady detecting D-G59F (with indicator light)
area, the difference of detecting Auto switch model D-G59F
position can be confirmed by the Wiring 4-wire
side of PLC (Programmable Logic Output NPN
Controller). Diagnostic output Normal operation
Applicable load IC circuit, Relay, PLC
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA)
Current leakage 100 µA or less at 24 VDC

Indicator light Operating position······Red LED lights when ON.


Optimum operating position······Green LED lights when ON.
Auto Switch Internal Circuit • Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.2 mm2, 4 cores (Brown, Black, Orange,
Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7.
DC (+)
Brown
OUT (Normal output)
Weight
Black
(g)
Main circuit
of switch

Diagnosis OUT
(Diagnostic output)
Auto switch model D-G59F
Orange
0.5 20
Lead wire length
(m) 3 74
DC (–)
Blue 5 117

Diagnostic Output Operation


The diagnostic signal is ON
output within unsteady
detecting area (where OFF Red Green Red OFF Red
Indicator light
indicator light is Red), and
the diagnostic output
becomes OFF when the OUT
detecting position remains (Normal output)
within the optimum
operating position (where
indicator is Green). When Diagnosis OUT
the detecting position is not (Diagnostic output)
adjusted, the diagnostic
output becomes ON.

Dimensions
ø4

Indicator light

ø4.5 mounting hole

Most sensitive position

8-30-40
2-color Indication Type with Diagnostic Output
Solid State Switch: Rail Mounting Style
D-F79F For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Since the output signal can be PLC: Abbreviation of Programmable Logic Controller
detected in an unsteady detecting D-F79F (With indicator light)
area, the difference of detecting Auto switch model D-F79F MX
position can be confirmed by the Wiring 4-wire
side of PLC (Programmable Logic Output NPN MTS
Controller). Diagnostic output Normal operation
Applicable load IC circuit, Relay, PLC
MY
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption
CY
10 mA or less
Load voltage 28 VDC or less MG
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA) CX
Current leakage 100 µA or less at 24 VDC
Operating position······Red LED lights when ON.
D-
Indicator light
Optimum operating position······Green LED lights when ON.
Auto Switch Internal Circuit
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue), 0.5 m
-X
Note 1) Regarding the common specifications of the solid state switches, refer to page 8-30-7.
Note 2) Regarding the lead wire length, refer to page 8-30-7. 20-
DC (+)
Brown Weight Data
OUT (Normal output)
Black (g)
Main circuit

Auto switch model D-F79F


of switch

Diagnosis OUT
(Diagnostic output) 0.5 13
Orange Lead wire length
(m) 3 56
DC (–) 5 90
Blue

Diagnostic Output Operation


The diagnostic signal is ON
output within unsteady OFF Red Green Red OFF Red
detecting area (where Indicator light
indicator light is Red), and
the diagnostic output
becomes OFF when the OUT
detecting position remains (Normal output)
within the optimum
operating position (where
indicator is Green). When Diagnosis OUT
(Diagnostic output)
the detecting position is not
adjusted, the diagnostic
output becomes ON.

Dimensions
ø3.2 mounting hole
Indicator light
ø3.4

Most sensitive position

8-30-41
2-color Indication Type with Diagnostic Output
Solid State Switch: Tie-rod Mounting Style
D-F59F For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Since the output signal can be PLC: Abbreviation of Programmable Logic Controller
detected in an unsteady detecting D-F59F (With indicator light)
area, the difference of detecting Auto switch model D-F59F
position can be confirmed by the Wiring type 4-wire
side of PLC (Programmable Logic Output type NPN
Controller). Diagnostic output Normal operation
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA)
Leakage current 100 µA or less at 28 VDC

Indicator light Operating position······Red LED lights when ON.


Optimum operating position······Green LED lights when ON.
Auto Switch Internal Circuit • Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 11-11-5.
Note 2) Regarding the lead wire length, refer to page 11-11-5.

DC (+)
Brown Weight
OUT (Normal output)
Black (g)
Main circuit

D-F59F
of switch

Diagnosis OUT Auto switch model


(Diagnostic output)
Orange 0.5 22
Lead wire length
(m) 3 77
DC (–) 5 121
Blue

Diagnostic Output Operation


The diagnostic signal is
output within unsteady ON
detecting area (where OFF Red Green Red OFF Red
indicator light is Red), and Indicator light
the diagnostic output
becomes OFF when the
detecting position remains OUT
within the optimum (Normal output)
operating position (where
indicator is Green). When Diagnosis OUT
the detecting position is not (Diagnostic output)
adjusted, the diagnostic
output becomes ON.

Dimensions

Mounting hole

Indicator light
ø4

Most sensitive position

11-11-28
2-color Indication Type Solid State Switch
Band Mounting Style
D-H7NW/D-H7PW/D-H7BW For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-H7W (With indicator light)
of the light. Auto switch model D-H7NW D-H7PW D-H7BW
(Red → Green ← Red) Wiring type 2-wire
3-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
Indicator light
Auto Switch Internal Circuit Optimum operating position······Green LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
D-H7NW 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
DC (+) Note 2) Regarding the lead wire length, refer to page 6-16-7.
Brown
Main circuit

OUT
of switch

Black
Weight
DC (–) (g)
Blue
Auto switch model D-H7NW D-H7PW D-H7BW
0.5 13 13 11
Lead wire length
D-H7PW (m) 3 57 57 50
5 92 92 81
DC (+)
Brown
Main circuit
of switch

OUT Dimensions
Black

DC (–)
Blue

D-H7BW

OUT (+) Indicator light


Brown
Main circuit
of switch

ø3.5 mounting hole

OUT (–)
Blue

Most sensitive position


Indicator light/Display method

Operating range

Indication
Red Green Red

Optimum operating position

6-16-40
2-color Indication Type Solid State Switch
Band Mounting Style
D-G59W/D-G5PW/D-K59W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-G5W, D-K59W (With indicator light)
of the light.
(Red → Green ← Red)
Auto switch model D-G59W D-G5PW D-K59W CJ1
Wiring type 3-wire 2-wire
Output type NPN PNP — CJP
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — CJ2
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
CM2
Load current 40 mA or less 80 mA or less 5 to 40 mA
CG1
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current) MB
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON. MB1
Indicator light
Optimum operating position······Green LED lights when ON.
Auto Switch Internal Circuit
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), CA2
D-G59W 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7. CS1
DC (+)
Note 2) Regarding the lead wire length, refer to page 6-16-7.
Brown
C76
Main circuit

OUT
of switch

Black
Weight C85
(g)
DC (–)
Blue
C95
Auto switch model D-G59W D-G5PW D-K59W

Lead wire length


0.5 20 20 18 CP95
D-G5PW (m) 3 78 78 68
5 124 124 108 NCM
DC (+)
Brown
NCA
Main circuit
of switch

OUT Dimensions
Black D-
DC (–)
Blue -X
20-
D-K59W
Data
OUT (+)
Brown
Indicator light
Main circuit
of switch

ø4.5 mounting hole

OUT (–)
Blue

Indicator light/Display method


Most sensitive position

Operating range

Indication
Red Green Red

Optimum operating position

6-16-41
2-color Indication Type Reed Switch
Rail Mounting Style
D-A79W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-A79W (With indicator light)
of the light. Auto switch model D-A79W
(Red → Green ← Red) CJ1
Applicable load Relay, PLC
Load voltage 24 VDC CJP
Load current range (3) 5 to 40 mA
Contact protection circuit None CJ2
Internal voltage drop 4 V or less
Operating position······Red LED lights when ON.
CM2
Indicator light
Optimum operating position······Green LED lights when ON.
CG1
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7. MB
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
MB1
Auto Switch Internal Circuit more.
CA2
D-A79W
Weight
OUT (+) CS1
Brown (g)
Reed switch
Reverse flow
prevent diode Auto switch model D-A79W C76
Main circuit
of switch

0.5 11
LED
Lead wire length
3 53 C85
(m)
OUT (–) 5 —
Blue C95
Indicator light/Display method CP95
Dimensions
NCM
Operating range

Indication
NCA
Red Green Red
D-
Optimum operating position
-X
Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer. 20-
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 6-16-7 for contact Data
protection box.)

Most sensitive position

6-16-25
2-color Indication Type Solid State Switch
Rail Mounting Style
D-F79W/D-F7PW/D-J79W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-F7W, D-J79W
of the light.
Auto switch model D-F79W D-F7PW D-J79W
(Red → Green ← Red)
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
Indicator light
Auto Switch Internal Circuit Optimum operating position······Green LED lights when ON.

D-F79W • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
DC (+) Note 2) Regarding the lead wire length, refer to page 6-16-7.
Brown
Main circuit
of switch

OUT
Black
Weight
(g)
DC (–)
Blue Auto switch model D-F79W D-F7PW D-J79W
0.5 13 13 11
Lead wire length
D-F7PW (m) 3 57 57 50
5 92 92 81
DC (+)
Brown
Main circuit
of switch

OUT
Black Dimensions
DC (–) ø3.2 mounting hole
Blue
Indicator light

D-J79W
OUT (+)
Brown
Main circuit
of switch

Most sensitive position


OUT (–)
Blue

Indicator light/Display method

Operating range

Indication
Red Green Red

Optimum operating position

6-16-42
2-color Indication Type Solid State Switch
Rail Mounting Style
D-F7NWV/D-F7BWV For details about the applicable products
conforming to the standards applied in
some countries, refer to SMC’s web site.

Grommet Auto Switch Specifications


Electrical entry: Perpendicular PLC: Abbreviation of Programmable Logic Controller
The optimum operating position D-F7WV (With indicator light)
can be determined by the color Auto switch model D-F7NWV D-F7BWV CJ1
of the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) — CJP
Output type NPN
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
CJ2
Current consumption 10 mA or less —
CM2
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA CG1
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA load current) MB
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
MB1
Indicator light
Optimum operating position······Green LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
CA2
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7. CS1
Note 2) Regarding the lead wire length, refer to page 6-16-7.

C76
Auto Switch Internal Circuit Weight C85
D-F7NWV (g)
C95
Auto switch model D-F7NWV D-F7BWV
DC (+)
Brown Lead wire length
0.5 13 11 CP95
Main circuit

OUT 3 57 50
of switch

(m)
Black
5 92 81 NCM

DC (–) NCA
Blue
Dimensions D-
ø3.2 mounting hole
D-F7BWV -X
Indicator light
OUT (+)
Brown 20-
Main circuit
of switch

Data

OUT (–)
Blue

Indicator light/Display method

Operating range

Most sensitive position


Indication
Red Green Red

Optimum operating position

6-16-43
2-color Indication Type Reed Switch
Tie-rod Mounting Style
D-A59W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-A59W (With indicator light)
of the light.
(Red → Green ← Red) Auto switch model D-A59W RE BA
Applicable load Relay, PLC
Load voltage 24 VDC REC
Load current range (3) 5 to 40 mA
Contact protection circuit None CX
Internal voltage drop 4 V or less
Operating position······Red LED lights when ON.
CY
Indicator light
Optimum operating position······Green LED lights when ON.
MQ MQ
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7. RHC
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
MK(2)
Auto Switch Internal Circuit more.
RS QG
D-A59W
Choke coil Weight
OUT (+) RS AH
Brown (g)
Reed switch
Zener diode Auto switch model D-A59W RZQ
Main circuit
of switch

0.5 25
LED
Lead wire length
(m) 3 80 MI WS
OUT (–) 5 —
Blue CEP1
Indicator light/Display method Dimensions CE1

Operating range
CE2

Indication
ML2B
Red Green Red

C GJ 5-S
Optimum operating position
CV
Indicator light MVGQ
CC
RB
J
Most sensitive position
D-
-X
20-
Data

10-20-25
2-color Indication Type Solid State Switch
Band Mounting Style
D-F59W/D-F5PW/D-J59W For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color
of the light. D-F5W, D-J59W (With indicator light)
(Red → Green ← Red) Auto switch model D-F59W D-F5PW D-J59W
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
Indicator light
Auto Switch Internal Circuit Optimum operating position······Green LED lights when ON.

D-F59W • Lead wire –– Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
DC (+) Note 2) Regarding the lead wire length, refer to page 6-16-7.
Brown
Main circuit

OUT
of switch

Black

Weight
DC (–) (g)
Blue
Auto switch model D-F59W D-F5PW D-J59W
0.5 23 23 21
Lead wire length
D-F5PW (m) 3 81 81 71
5 127 127 111
DC (+)
Brown
Main circuit
of switch

OUT
Black
Dimensions

DC (–) Mounting hole


Blue

D-J59W Indicator light

OUT (+)
Brown
Main circuit
of switch

OUT (–)
Blue

Indicator light/Display method

Most sensitive position


Operating range

Indication
Red Green Red

Optimum operating position

6-16-44
2-color Indication Type Solid State Switch
Direct Mounting Style
D-F9NW(V)/D-F9PW(V)/D-F9BW(V) For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-F9W, D-F9WV (With indicator light)
Auto switch model D-F9NW D-F9NWV D-F9PW D-F9PWV D-F9BW D-F9BWV RE BA
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire REC
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC CX
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
CY
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
MQ MQ
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less RHC
at 10 mA load current)
Auto Switch Internal Circuit Leakage current 100 µA or less at 24 VDC 0.8 mA or less MK(2)
D-F9NW, D-F9NWV Operating position······Red LED lights when ON.
Indicator light
Optimum operating position······Green LED lights when ON. RS QG
DC (+)
• Lead wire — Oil resistant vinyl heavy-duty cord: ø2.7, 3 cores (Brown, Black, Blue), 0.15 mm2
Brown
2 cores (Brown, Blue) 0.18 mm2, 0.5 m RS AH
Main circuit

OUT
of switch

Black
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.
RZQ
Weight
DC (–)
Blue
MI WS
(g)
Auto switch model D-F9NW(V) D-F9PW(V) D-F9BW(V) CEP1
0.5 7 7 7
D-F9PW, D-F9PWV Lead wire length CE1
(m) 3 34 34 32
DC (+) 5 56 56 52
Brown CE2
Main circuit
of switch

Dimensions
OUT
Black
ML2B
D-F9W Mounting screw M2.5 x 4l
DC (–) Slotted set screw C GJ 5-S
Blue
Indicator light
ø2.7

2
CV
D-F9BW, D-F9BWV MVGQ
22
2.8
2.6

OUT (+)
Brown
4 CC
Main circuit
of switch

Most sensitive position


6 RB
J
OUT (–)
Blue D-F9WV
Mounting screw M2.5 x 4l
Slotted set screw
D-
4.3
Indicator light/Display method 2 Indicator light -X

Operating range
20-
ø2.7 20
2.8
4.6

Indication Data
3.8

Red Green Red

Optimum operating position


6.2

4
3.1

6 Most sensitive position

10-20-47
2-color Indication Type Solid State Switch
Direct Mounting Style
D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V) For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position PLC: Abbreviation of Programmable Logic Controller
can be determined by the color D-Y7W, D-Y7WV (With indicator light)
of the light. (Red → Green ← Red)
Auto switch model D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV CJ1
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire CJP
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC CJ2
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
CM2
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) CG1
Load current 40 mA or less 80 mA or less 5 to 40 mA

Internal voltage drop


1.5 V or less
(0.8 V or less 0.8 V or less 4 V or less
MB
at 10 mA load current)
Auto Switch Internal Circuit Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC MB1
D-Y7NW, D-Y7NWV Operating position······Red LED lights when ON.
Indicator light Optimum operating position······Green LED lights when ON. CA2
DC (+)
• Lead wire — Oil resistant, flexible vinyl heavy-duty cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue),
Brown
2 cores (Brown, Blue), 0.5 m CS1
Main circuit

OUT
of switch

Black Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7. C76
DC (–)
Weight C85
Blue
(g)
Auto switch model D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) C95
D-Y7PW, D-Y7PWV 0.5 11 11 11
Lead wire length
3 54 54 54
CP95
(m)
DC (+)
5 88 88 88
Brown NCM
Main circuit
of switch

OUT Dimensions NCA


Black
D-Y7W Mounting screw M2.5 x 4l
DC (–) Slotted set screw D-
Blue
Indicator light
ø3.4

2.5
-X
SMC
6.2

D-Y7BW, D-Y7BWV 20-


29
OUT (+)
Brown
Data
Main circuit
of switch

12.5 Most sensitive position


OUT (–)
Blue D-Y7WV Mounting screw M2.5 x 4l
Slotted set screw
Indicator light
2.5
Indicator light/Display method
SMC
6.2

Operating range
27.3
Indication
Red Green Red
ø3.4

Optimum operating position


8.5
5

12.5 Most sensitive position

6-16-45
2-color Indication Type Solid State Switch
Direct Mounting Style
D-M5NW/D-M5PW/D-M5BW For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


The optimum operating position
can be determined by the color D-M5W (With indicator light)
of the light. Auto switch model D-M5NW D-M5PW D-M5BW
(Red → Green ← Red) Wiring type 3-wire 2-wire RE BA
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
REC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
CX
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) CY
Load current 40 mA or less 80 mA or less 5 to 40 mA

Internal voltage drop


1.5 V or less MQ MQ
(0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 1 mA or less at 24 VDC
RHC
Operating position······Red LED lights when ON.
Auto Switch Internal Circuit Indicator light
Optimum operating position······Green LED lights when ON.
MK(2)
D-M5NW Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
• Lead wire
2 cores (Brown, Blue) 0.5 m
RS QG
DC (+)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Brown Note 2) Regarding the lead wire length, refer to page 10-20-7. RS AH
Main circuit

OUT
of switch

Black
RZQ
Weight
DC (–) (g) MI WS
Blue
Auto switch model D-M5NW D-M5PW D-M5BW
0.5 16 16 14
CEP1
Lead wire length
D-M5PW (m) 3 60 60 53
CE1
5 95 95 84
DC (+)
Brown CE2
Main circuit

Dimensions
of switch

OUT ML2B
Black Indicator light

DC (–)
C GJ 5-S
Blue
CV
D-M5BW MVGQ
OUT (+) CC
Brown
Main circuit

RB
of switch

ø3 mounting hole

J
OUT (–)
Blue
D-
Indicator light/Display method Most sensitive position -X

Operating range
20-
Indication Data
Red Green Red

Optimum operating position

10-20-49
6-15-36
6-15-36
6-15-36
6-15-36
Solid State Switch with Timer
Band Mounting Style
D-G5NTL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller

D-G5NTL (With indicator light)


Auto switch model D-G5NTL
Wiring type 3-wire
Output type NPN
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight
(g)
Auto switch model D-G5NT
0.5 —
Lead wire length
(m) 3 78
Auto Switch Internal Circuit
5 124

DC (+)
Brown
Timer Operation
Detection of intermediate positioning for high-speed cylinder
Main circuit
of switch

OUT Detecting point dispersion occurs due to


Black Switch operating range (mm)
response time of PLC (sequencer); e.g. Switch detecting time Cylinder speed (mm/s)
scanning.
Ex.) Cylinder speed — 1000 mm/sec. Switch output ON time
DC (–)
Blue
Sequencer response time — 0.1 sec.
Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into considera- PLC response time
tion when using.

Dimensions
ø4

Indicator light
ø4.5 mounting hole

Most sensitive position

10-20-60
Solid State Switch with Timer
Rail Mounting Style
D-F7NTL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller

D-F7NTL (With indicator light)


Auto switch model D-F7NTL RE BA
Wiring type 3-wire
Output type NPN REC
Output operation Off-delay
Operating time 1 ms or less CX
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
CY
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
MQ MQ
Current consumption 10 mA or less
Load voltage 28 VDC or less RHC
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA) MK(2)
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED lights when ON.
RS QG
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard) RS AH
Note 1) For the solid state switch common specifications, refer to page 10-20-7.
Note 2) For lead wire length, refer to page 10-20-7. RZQ
Weight
MI WS
(g)
Auto switch model D-F7NT CEP1
0.5 —
Lead wire length
3 57
CE1
Auto Switch Internal Circuit (m)
5 92
CE2
DC (+) Timer Operation ML2B
Brown
Detection of intermediate positioning for high-speed cylinder
Main circuit

C GJ 5-S
of switch

OUT Detecting point dispersion occurs due to


Switch operating range (mm)
Black response time of PLC (sequencer); e.g. Switch detecting time Cylinder speed (mm/s)
scanning.
CV
Ex.) Cylinder speed — 1000 mm/sec. Switch output ON time
DC (–) Sequencer response time — 0.1 sec.
Blue Detecting point dispersion — Within MVGQ
100 mm (= 1000 mm/sec. x 0.1 sec.)
PLC response time
Take PLC response time into considera-
tion when using.
CC

Dimensions RB
ø3.2 mounting hole J
Indicator light
D-
-X
20-
ø3.4

Data

Most sensitive position

10-20-61
Solid State Switch with Timer
Tie-rod Mounting Style
D-F5NTL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller

D-F5NTL (With indicator light)


Auto switch model D-F5NTL
Wiring type 3-wire
Output type NPN
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight
(g)
Auto switch model D-F5NT
0.5 —
Lead wire length
(m) 3 81
Auto Switch Internal Circuit
5 127

DC (+)
Brown
Timer Operation
Detection of intermediate positioning for high-speed cylinder
Main circuit
of switch

OUT Detecting point dispersion occurs due to


Black Switch operating range (mm)
response time of PLC (sequencer); e.g. Switch detecting time Cylinder speed (mm/s)
scanning.
Ex.) Cylinder speed — 1000 mm/sec. Switch output ON time
DC (–) Sequencer response time — 0.1 sec.
Blue
Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into considera- PLC response time
tion when using.

Dimensions

Mounting hole

Indicator light
ø4

Most sensitive position

10-20-62
Solid State Switch with Timer
Direct Mounting Style
D-M5NTL/D-M5PTL For details about the applicable products
conforming to the standards applied in
some countries, refer to SMC’s web site.

Grommet Auto Switch Specifications


With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller
D-M5TL (With indicator light)
Auto switch model D-M5NTL D-M5PTL RE BA
Wiring type 3-wire
Output type NPN PNP REC
Output operation Off-delay
Operating time 1 ms or less CX
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
CY
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
MQ MQ
Current consumption 10 mA or less 12 mA or less
Load voltage 28 VDC or less — RHC
Load current 80 mA or less

Internal voltage drop


2 V or less MK(2)
0.8 V or less
(0.8 V or less at 10 mA load current)
Leakage current 100 µA or less at 24 VDC RS QG
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 3 m
RS AH
(Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7. RZQ
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight MI WS
(g) CEP1
Auto switch model D-M5NT D-M5PT
Auto Switch Internal Circuit 0.5 — — CE1
Lead wire length
3 60 60
(m)
5 95 95
CE2
DC (+)
Brown
Timer Operation ML2B
Main circuit
of switch

OUT
Black Detection of intermediate positioning for high-speed cylinder C GJ 5-S
Detecting point dispersion occurs due to
Switch operating range (mm)
response time of PLC (sequencer); e.g.
scanning.
Switch detecting time Cylinder speed (mm/s) CV
DC (–)
Blue
Ex.) Cylinder speed — 1000 mm/sec. Switch output ON time MVGQ
Sequencer response time — 0.1 sec.
Detecting point dispersion — Within
Indicator light/Display method 100 mm (= 1000 mm/sec. x 0.1 sec.)
PLC response time
CC
Take PLC response time into considera-
tion when using.
DC (+)
Brown
RB
Dimensions
J
Main circuit
of switch

Indicator light
OUT
D-
ø3.4

Black

DC (–)
Blue
-X
20-
ø3 mounting hole Data

Most sensitive position

10-20-63
Water Resistant 2-color Indication Type
Solid State Switch: Band Mounting Style
D-H7BAL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-H7BAL (With indicator light)
Auto switch model D-H7BAL
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Caution Leakage current 0.8 mA or less at 24 VDC
Precautions Operating position······Red LED lights when ON.
Indicator light
Please consult with SMC if using coolant Optimum operating position······Green LED lights when ON.
liquid other than water based solution. • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight
(g)
Auto switch model D-H7BA
0.5 —
Lead wire length
(m) 3 50
5 81
Auto Switch Internal Circuit

OUT (+) Dimensions


Brown
Main circuit
of switch

ø3.4

OUT (–)
Blue

Indicator light
Indicator light/Display method
ø3.5 mounting hole

Operating range

Indication
Red Green Red Most sensitive position

Optimum operating position

10-20-54
Water Resistant 2-color Indication Type
Solid State Switch: Band Mounting Style
D-G5BAL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-G5BAL (With indicator light)
Auto switch model D-G5BAL RE BA
Wiring type 2-wire
Output type — REC
Applicable load 24 VDC Relay, PLC
Power supply voltage — CX
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
CY
Load current 5 to 40 mA
MQ MQ
Internal voltage drop 4 V or less
Caution Leakage current 0.8 mA or less at 24 VDC RHC
Precautions Operating position······Red LED lights when ON.
Indicator light
Please consult with SMC if using coolant Optimum operating position······Green LED lights when ON. MK(2)
liquid other than water based solution. • Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.
RS QG
RS AH
Weight
(g)
RZQ
Auto switch model D-G5BA MI WS
0.5 —
Lead wire length
(m) 3 68 CEP1
5 108
Auto Switch Internal Circuit CE1
CE2
OUT (+) Dimensions
Brown ML2B
Main circuit
of switch

C GJ 5-S
ø4

OUT (–) CV
Blue
Indicator light
MVGQ

Indicator light/Display method ø4.5 mounting hole CC


RB
Operating range
J
Indication Most sensitive position
Red Green Red
D-
Optimum operating position -X
20-
Data

10-20-55
Water Resistant 2-color Indication Type
Solid State Switch: Rail Mounting Style
D-F7BA(V)L For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-F7BA(V)L (With indicator light)
Auto switch model D-F7BAL D-F7BAVL
Electrical entry direction In-line Perpendicular
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Caution Internal voltage drop 4 V or less
Precautions Leakage current 0.8 mA or less at 24 VDC
Please consult with SMC if using coolant liquid Operating position······Red LED lights when ON.
other than water based solution. Indicator light Optimum operating position······Green LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight
(g)
Auto switch model D-F7BA D-F7BAV
0.5 — —
Lead wire length
(m) 3 50 50
Auto Switch Internal Circuit 5 81 81

Dimensions
OUT (+)
Brown D-F7BAL ø3.2 mounting hole
Main circuit

Indicator light
of switch

15

OUT (–)
Blue

Indicator light/Display method Most sensitive position

Operating range

D-F7BAVL ø3.2 mounting hole


Indication 8
Red Green Red Indicator light
15

Optimum operating position


SMC
7

23

ø3.4
3.2
15
11

6.2

8.5 Most sensitive position

10-20-56
Water Resistant 2-color Indication Type
Solid State Switch: Tie-rod Mounting Style
D-F5BAL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-F5BAL (With indicator light)
Auto switch model D-F5BAL RE BA
Wiring type 2-wire
Output type — REC
Applicable load 24 VDC Relay, PLC
Power supply voltage — CX
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
CY
Load current 5 to 40 mA
MQ MQ
Internal voltage drop 4 V or less
Caution Leakage current 0.8 mA or less at 24 VDC RHC
Precautions Operating position······Red LED lights when ON.
Indicator light
Please consult with SMC if using coolant Optimum operating position······Green LED lights when ON. MK(2)
liquid other than water based solution. • Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 3 m (Standard)
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7. RS QG
Note 2) Regarding the lead wire length, refer to page 10-20-7.

RS AH
Weight
RZQ
(g)
Auto switch model D-F5BA MI WS
0.5 —
Lead wire length
(m) 3 71 CEP1
5 111
Auto Switch Internal Circuit CE1
CE2
OUT (+) Dimensions
Brown ML2B
Main circuit
of switch

Mounting hole
C GJ 5-S
Indicator light
OUT (–) CV
Blue

MVGQ
ø4

Indicator light/Display method CC


RB
Operating range
J
Indication
Red Green Red
D-
Most sensitive position
Optimum operating position -X
20-
Data

10-20-57
Water Resistant 2-color Indication Type
Solid State Switch: Direct Mounting Style
D-F9BAL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-F9BAL (With indicator light)
Auto switch model D-F9BAL
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 30 mA
Internal voltage drop 5 V or less
Caution Leakage current 1 mA or less at 24 VDC
Precautions Operating position······Red LED lights when ON.
Indicator light
Please consult with SMC if using coolant Optimum operating position······Green LED lights when ON.
liquid other than water based solution. • Lead wire — Oil resistant vinyl heavy-duty cord, ø2.7, 2 cores (Brown, Blue), 0.18 mm2, 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Note 2) Regarding the lead wire length, refer to page 10-20-7.

Weight
(g)
Auto switch model D-F9BA
0.5 —
Lead wire length
(m) 3 37
5 57
Auto Switch Internal Circuit

OUT (+) Dimensions


Brown
M2.5 x 4l
Main circuit
of switch

Slotted set screw


Indicator light
ø2.7

OUT (–)
Blue

Indicator light/Display method

Operating range
Most sensitive position
Indication
Red Green Red

Optimum operating position

10-20-58
Water Resistant 2-color Indication Type
Solid State Switch: Direct Mounting Style
D-Y7BAL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller
D-Y7BAL (With indicator light)
Auto switch model D-Y7BAL RE BA
Wiring type 2-wire
Applicable load 24 VDC Relay, PLC REC
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA or less CX
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
CY
Indicator light
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
MQ MQ
Caution • Lead wire — Oil resistant, flexible vinyl heavy-duty cord, ø3.4, 0.15 mm2, 2 cores (Brown, Blue), 3 m
RHC
(Standard)
Precautions Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
Please consult with SMC if using coolant liquid Note 2) Regarding the lead wire length, refer to page 10-20-7. MK(2)
other than water based solution.
RS QG
Weight
(g) RS AH
Auto switch model D-Y7BA
RZQ
0.5 —
Lead wire length
(m) 3 54 MI WS
5 88
CEP1
Auto Switch Internal Circuit Dimensions CE1
Mounting screw M2.5 x 4l
Slotted set screw CE2
OUT (+) Indicator light
Brown ML2B
Main circuit
of switch

C GJ 5-S
OUT (–) CV
Blue

MVGQ

Indicator light/Display method CC


Most sensitive position
RB
Operating range
J
Indication
Red Green Red
D-
Optimum operating position -X
20-
Data

10-20-59
6-15-36
Magnetic Field Resistant 2-color Indication Type
Solid State Switch: Rail Mounting Style
D-P5DWL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Possible to use in an environment PLC: Abbreviation of Programmable Logic Controller
where disturbance magnetic fields D-P5DW (With indicator light)
are generated. Auto switch model D-P5DWL
Wiring type 2-wire (non-polar)
Applicable load 24 VDC relay, PLC
Load voltage 24 VDC (20 to 28 VDC)
Load current 6 to 40 mA or less
Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less

Operating position······Red LED lights when ON.


Indicator light
Caution Optimum operating position······Green LED lights when ON.
Precautions • Lead wire — Oil resistant vinyl heavy-duty cord, ø6, 0.5 mm2, 2 cores (Brown, Blue), 3 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 10-20-7.
For use with single-phase AC welders. Not Note 2) Regarding the lead wire length, refer to page 10-20-7.
applicable for DC inverter welding, arc
welding nor capacitor welding.
Weight
(g)
Auto switch model D-P5DW
0.5 —
Lead wire length
(m) 3 150
5 244

Auto Switch Internal Circuit Magnetic Field Resistance


When the AC welding current is 16000 A or less, the operational distance between the welding
conductor (welding gun or cable) and the cylinder or auto switch can be 0 mm.
Please consult with SMC when exceeding 16000 A.
Main circuit

OUT (±)
of switch

Brown
±
Dimensions
OUT ( )
Blue
Indicator light
ø6

Indicator light/Display method

Operating range OFF 2-ø3.5 mounting hole

Indication
Red Green Red

Optimum operating position

Most sensitive position

10-20-64
Magnetic Field Resistant 2-Color Display
Solid State Auto Switch
D-P3DW/L/Z
(Electrical entry: Grommet)
For details about certified products
conforming to international standards,
Auto Switch Specifications visit us at www.smcworld.com.

 It is possible to use in an PLC: Programmable Logic Controller


environment which generates a
D-P3DW/L/Z (With indicator light)
magnetic field disturbance (AC
Auto switch model D-P3DW/L/Z
magnetic field).
Applicable load 24 VDC relay, PLC
 The optimum operating position 24 VDC (20 to 28 VDC)
Load voltage
can be determined by the color
Load current 6 to 40 mA
of the light.
(Red → Green ← Red) Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating position······Red LED illuminates.
Indicator light
Optimum operating position······Green LED illuminates.
Standards CE marking, UL (CSA), RoHS
• Lead wire — Oilproof heavy-duty vinyl cable, ø0.189, 0.775 x 10–3 in2, 2 cores,
D-P3DW: 19.7 in, D-P3DWL: 118 in, D-P3DWZ: 197 in
• Impact resistance — Switch: 39370 in/s2
• Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
• Ambient temperature — 14 to 140°F
• Enclosure — IEC60529 standard IP67
Caution • Polarity: Non-polar
Precautions
For single-phase AC welding machines Magnetic Field Resistance
If it is used for current inverter welders (including
rectifying type) and condenser type welders, the If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the
magnetic field resistance is reduced. Please contact distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 in.
SMC regarding the performance. Please contact SMC when the AC welding current exceeds 16000 A.

Mass Unit: lb(s)

Auto Switch Internal Circuit Auto switch model D-P3DW/L/Z


D-P3DW/L/Z 19.7 0.044
Lead wire length (in) 118 0.225
197 0.37
main circuit

OUT (±) Brown


Switch

OUT ( ±) Blue
Dimensions Unit: in
ø0.189

Body Indicator light


0.236

Indicator light/Display method


ø0.11 mounting hole
ON 0.118
Operating 1.14 19.7 (118, 197)
0.433 0.0394

range OFF

Indication
Red Green Red

Optimum operating Most sensitive


0.126

position 0.413 position

Auto switch mounting bracket Auto switch mounting bracket


(For round groove mounting: (For square groove mounting:
BQ3-032S) BMG5-025S)

0.185 (1.14) 0.185 (1.14)


0.157

0.157
0.539 Most sensitive 0.244 0.539 Most sensitive
(0.598) position (0.598) position

∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed. In that
case, please order it separately.

2
Magnetic Field Resistant 2-color Indication
Solid State Switch
D-P4DWL/D-P4DWZ
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
Auto Switch Specifications
Grommet PLC: Programmable Logic Controller
It is possible to use in an envi- D-P4DW쏔 (With indicator light)
ronment which generates a Auto switch model D-P4DWL D-P4DWZ
magnetic field disturbance (AC Applicable load 24 VDC relay, PLC
magnetic field). Load voltage 24 VDC (20 to 28 VDC)
Load current 6 to 40 mA or less
Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating position······Red LED illuminates when turned ON.
Indicator light
Optimum operating position······Green LED illuminates when turned ON.
• Lead wire — Oilproof heavy-duty vinyl cable, ø6, 0.5 mm2, 2 cores,
D-P4DWL: 3 m, D-P4DWZ: 5 m
• Impact resistance — 1000 m/s2
• Insulation resistance — 50 M or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
• Ambient temperature — –10 to 60C
Caution • Enclosure — IEC529 standard IP67, JIS 0920 waterproof structure
Precautions
For single-phase AC welding machines
Not applicable for DC inverter welding Magnetic Field Resistance
machines (including rectifying type) and or
condenser type welding. If the current of the AC welding machine is 16,000 A or lower, the switch can be used, even if the
distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm.
Please contact SMC when the AC welding current exceeds 16,000 A.
Auto Switch Internal Circuit
D-P4DWL/Z
Dimensions Unit: mm
main circuit

OUT () Brown Indicator light


Switch

ø6

OUT () Blue
9.2
8.8

SMC

D-P4DW (DC24V)

32 4 3000 (5000)
Indicator light/Display method
ON
Operating 6 2-ø3.5 mounting hole
range OFF
1
6

Indication
20

Red Green Red

Optimum operating
position
13 Most sensitive position

20
Magnetic Field Resistant Reed Switches
D-P70/P74/P75/P80
Auto Switch Specifications
Grommet
D-P70, D-P74, D-P75 (with indicator light)
Auto switch part no. D-P70 D-P74 D-P75
Electrical entry Grommet
Application Relay, PLC PLC
Load voltage 100VAC 24VDC 100VDC 24VDC
Max. load voltage/Load current range 20mA 5 to 40mA 5 to 20mA 40mA
Contact protection circuit Yes No
Internal voltage drop (internal resistance) (10Ω or less) 2.4V or less (0)
Leakage current 1.8mA 0 1.2mA

Indicator light Red LED lights Red LED lights Red LED lights
up when OFF up when ON up when OFF

D-P80 (without indicator light)


Auto switch part no. D-P80
Electrical entry Grommet
Application Relay, PLC
AC AC AC
Load voltage 24V DC or less 48V DC 100V DC
Maximum load voltage 50mA 40mA 20mA
Contact protection circuit No
Internal resistance 0
Caution • Operating time 1.2ms
Refer to "Magnetic Field Resistant Reed • Lead wire Oil resistant, fire resistant heavy duty cord, ø6.8, 0.75mm², 2 wire (Brown, Blue [White, Black]), 0.5m∗
• Impact resistance 300m/s²
Switches/Specific Product Precautions" • Insulation resistance 50MΩ or more at 500VAC (between lead wire and case)
(pages 31 and 32). • Ambient temperature –10 to 60°C
• Enclosure IEC standard IP67, watertight (JISCO920), oil proof construction
∗ Indicate "L" for 3m lead wire and "Z" for 5m lead wire at the end of an auto switch part number.

Auto Switch Internal Circuits


D-P70 Surge absorber

Reed switch Auto Switch Dimensions


Choke LED
coil Resistor
ø6.8

Diode
Brown Blue
[White] [Black]

D-P74 Surge absorber Printed auto switch part no.


Choke Resistor Reed 2 x 2-ø6 32 5 500 (3000) [5000] 13.6
coil switch
Depth of counter bore 2.4 5 22
LED
2-ø3.4 through
Zener diode
4

Brown Blue D-P70


(+) (–)
20

[White] [Black]

D-P75 Reed switch


Lead wire: Oil and fire resistant
Case: PBT resin Effective operating range∗ 3mm 0.75mm² x 2
Resistor Fire resistant (UL94-V0) Operating range∗∗ (Refer to the table below.) l

16 Most sensitive position


LED
Diode bridge
Brown Blue
[White] [Black] Operating range ( Dimension l )
D-P80 Applicable bore sizes (mm) ∗ Effective operating range:
Reed switch Cylinder series The range with enough magnetic force to resist
Brown Blue 40 50 63 malfunction due to the outside magnetic field
[White] [Black] CLK1P 7 8 8 when the switch is ON.
∗∗ Operating range:
The range within which the switch turns ON.

21
6-15-36
Heat Resistant 2-color Indication Type
Solid State Switch: Rail Mounting Style
D-F7NJL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


Improved heat resistant type PLC: Abbreviation of Programmable Logic Controller
D-F7NJL (With indicator light)
Auto switch model D-F7NJL CUJ
Wiring type 3-wire
Output type NPN CU
Applicable load Relay, PLC
Power supply voltage 24 VDC (20 to 26 VDC) CQS
Current consumption 25 mA or less
Load voltage 28 VDC or less
CQM
Load current 40 mA
CQ2
Internal voltage drop 0.8 V or less
Caution Leakage current 100 µA at 24 VDC RQ
Precautions Operating position······Red LED lights when ON.
Indicator light
Auto switch which can be mounted on heat Optimum operating position······Green LED lights when ON. MU
resistant, compact cylinder, CDQ2-XB14. For
Sensor section: 0 to 150°C
using for other cylinders, please confirm Ambient temperature D-
Amplifier section: 0 to 60°C
SMC.
Sensor section: 1000 m/s2
Impact resistance
Amplifier section: 300 m/s2 -X
• Lead wire — Between sensor and amplifier: Oil resistant vinyl heavy-duty cord, ø3.4, 3 m
Grommet on amplifier: Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores
20-
(Brown, Black, Blue), 3 m
Data
Weight
(g)
Auto switch model D-F7NJ
Auto Switch Internal Circuit
0.5 —
Lead wire length
(m) 3 170
Amplifier section
DC (+)
5 210
Sensor section
Brown lead wire
Main circuit

OUT
of switch

Main

Black lead wire


Dimensions
Indicator light
MAX. 150°C OUT (–)
Blue lead wire 3.8 21.6
MAX. 60°C
AUTO SWITCH
HEAT PROOF

MODE POSITION
AMPLIFIRE
22

SMC

7
15

Indicator light/Display method (4) (64.5) 0.7 8

Operating range

Oil resistant vinyl heavy-duty cord


ø3.4

Indication
Red Green Red
3
24 VDC
D-F7NJ
BLACK (OUT) NPN 24 V 40 mA

Load
BROWN

40 mA

11
BLACK

MAX.

CAUTION
BLUE
GND

MADE IN JAPAN
OUT
Vcc

Don't install heated atmosphere.


BROWN (+) 24 VDC

It might cause mal function and


circuit (amplifier) is 0 to 60°C.
40

Ambient temp. of detecting

Optimum operating position


lead to cause breakage.
BLUE (-) GND

6.2
Switch
Main Circuit

ø3.4

Most sensitive
position 8.5

7-9-35
6-15-36
Wide Range Detection Type
Solid State Switch: Band Mounting Style
D-G5NBL For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

Grommet Auto Switch Specifications


PLC: Abbreviation of Programmable Logic Controller
D-G5NBL (With indicator light)
Auto switch model D-G5NBL CJ1
Wiring type 3-wire
Output type NPN CJP
Applicable load Relay, PLC
Power supply voltage 12 VDC, 24 V (10 to 28 VDC) CJ2
Current consumption 12 mA or less
Load voltage 10 to 28 VDC or less
CM2
Load current 40 mA or less
CG1
Internal voltage drop 0.4 V or less
Leakage current 100 µA at 24 VDC MB
Indicator light Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m MB1
Note 1) Regarding the common specifications of the solid state switches, refer to page 6-16-7.
Note 2) Regarding the lead wire length, refer to page 6-16-7.
CA2

Weight CS1
(g) C76
Auto switch model D-G5NB
0.5 —
C85
Lead wire length
3 79
(m) C95
5 125

CP95
Auto Switch Internal Circuit
D-G5NBL Dimensions NCM

DC (+)
D-G5NB NCA
33 11.2
Brown
D-
Main circuit
of switch

ø4

OUT
Black
SMC

-X
14

12

OUT (–)
Blue 20-
Indicator light

Data
6.5 ø4.5 mounting hole
14.3

9.5

(16) Most sensitive position

6-16-59
Made to Order Specifications: Solid State Switch
With Pre-wired Connector
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

1 With Pre-wired Connector


• Eliminates the harnessing work by cable with connector specifications
• Adopts global standardized connector (IEC947-5-2)
• IP67 construction

How to Order
Connector Specifications
D— M9N S A PC Connector model M8–3 pin M8–4 pin M12–4 pin

1 4 1 2
2 1
Solid state switch Pin arrangement
3 4
Standard part no. 3 3 4
∗ For the applicable auto switch
model, refer to the table below. Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
Cable length Connector model
Impact resistance 300 m/s2
S 0.5 m A M8—3 pin
M 1.0 m B M8—4 pin Enclosure IP-67 (IEC529 standard)

L 3.0 m D M12—4 pin Insulation resistance 100 MΩ or more at 500 M VDC


Note) L is available for Note) Type D is available
the D-P5DW for the D-P5DW Withstand voltage 1500 VAC 1 minute (between contacts), Leak current 1 mA or less
type only. type only.

Applicable Auto Switch

Electrical Lead wire length Electrical Lead wire length


Mounting Function Applicable model Mounting Function Applicable model
entry 0.5 1.0 3.0 entry 0.5 1.0 3.0
Grommet (In-line) F79, F7P, J79 앬 앬 — Grommet M5N, M5P, M5B 앬 앬 —
— Grommet
(Perpendicular) F7NV, F7PV, F7BV 앬 앬 — (In-line) Y59A, Y7P, Y59B 앬 앬 —
Grommet
2-color Grommet (In-line) F79W, F7PW, J79W 앬 앬 — — (Perpendicular) Y69A, Y7PV, Y69B 앬 앬 —
Rail Grommet
indication (Perpendicular) F7NWV, F7BWV 앬 앬 — Grommet (In-line) M9N, M9P, M9B 앬 앬 —
mounting Grommet
style With diagnostic F79F 앬 앬 — (Perpendicular) M9NV, M9PV, M9BV 앬 앬 —
Water resistant F7BA 앬 앬 — Grommet M5NW, M5PW, M5BW 앬 앬 —
Direct
With timer F7NT 앬 앬 — mounting
(In-line) Y7NW, Y7PW, Y7BW 앬 앬 —
Grommet
Magnetic field P5DW 앬 앬 앬 style 2-color (Perpendicular) Y7NWV, Y7PWV, Y7BWV 앬 앬 —
H7A1, H7A2, H7B 앬 앬 — indication Grommet (In-line) F9NW, F9PW, F9BW 앬 앬 —
— Grommet
G59, G5P, K59 앬 앬 — (Perpendicular) F9NWV, F9PWV, F9BWV 앬 앬 —
2-color H7NW, H7PW, H7BW 앬 앬 — Water resistant Grommet Y7BA, F9BA 앬 앬 —
Band indication G59W, G5PW, K59W 앬 앬 — With timer (In-line) M5NT, M5PT 앬 앬 —
Grommet
mounting Diagnostic output H7NF, G59F 앬 앬 — Grommet S791/2, S7P1/2, T791/2 앬 앬 —
style (In-line) Rotary
Water resistant H7BA, G5BA 앬 앬 — — (In-line) S991/2, S9P1/2, T991/2 앬 앬 —
actuator
Grommet
With timer G5NT 앬 앬 — (Perpendicular) S99V1/2, T99V1/2 앬 앬 —
Wide detection G5NB 앬 앬 —
— F59, F5P, J59 앬 앬 —

Tie-rod 2-color indication F59W, F5PW, J59W 앬 앬 —


mounting Diagnostic output F59F 앬 앬 —
style Water resistant F5BA 앬 앬 —
With timer F5NT 앬 앬 —

6-16-60
With Pre-wired Connector

Connector Pin Arrangement


Color distinction of lead wire Meaning of contact number
Sensor type
1 pin 2 pin 3 pin 4 pin 1 pin 2 pin 3 pin 4 pin
DC 2-wire type Brown — — Blue OUT (+) — — OUT (–)
±
DC 2-wire, Non-polar type — — Brown Blue — — OUT (±) OUT ( )
DC 3-wire type Brown — Blue Black DC (+) — DC (–) OUT
Diagnostic
DC 4-wire type Brown Orange Blue Black DC (+) output DC (–) OUT

CJ1
Connector Specifications
Connector model M8–3 pin M8–4 pin M12–4 pin
CJP
1 2
M8—3 pin
1 4 CJ2
2 1
Pin arrangement
3 4 CM2
3 3 4

Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
CG1
Impact resistance 300 m/s2
MB
Enclosure IP-67 (IEC529 standard)

Insulation resistance 100 MΩ or more at 500 M VDC


MB1
Withstand voltage 1500 VAC 1 minute (between contacts), Leak current 1 mA or less
CA2
CS1
M8—4 pin Dimensions
C76
Connector model
C85
C95

ø10
Sensor section
M8—3 pin
4 pin
31.4
CP95
NCM
NCA
D-
M12—4 pin
M12—4 pin
Sensor section ø14
-X
44
20-
Data

Connection (Female side) Connector Cable


As the parts are not supplied from SMC, refer to the application examples listed in the below.
(For detail such as catalog availability, etc., please contact each manufacturer.)

Connector size Number of pins Manufacturer Applicable series example


3 M8-3D
Corrence Corporation
M8 M8-4D
OMROM Corporation XS3
Corrence Corporation VA-4D
4 OMROM Corporation XS2
M12 Yamatake-Honeywell Co., Ltd. PA5-4I
Hirose Electric Co., Ltd. HR24
DKK Ltd. CM01-8DP4S

6-16-61
Made to Order Specifications: Solid State Switch
-50: No Indicator (Dark room) Specifications
-61: Oil Resistant, Flexible Cable Specifications
Symbol
2 Without Indicator Light (for dark room specifications) -50
Possible to use under the environment which hates a light.

D 50

Without indicator light


Solid state switch model (for dark room specifications)
Applicable part no.: General purpose type,
solid state switch
except D-J51 Lead wire length
For lead wire length, refer to page 6-16-7.
Note) Please consult with
SMC for water
resistant type, timer
equipped type,
output dialysis type,
wide range
detection type,
magnetic field
resistant type, heat
resistant type.

Dimensions and specifications are common as standard products with the exception of no indicator light.

Symbol
3 Oil Resistant, Flexible Heavy-duty Cord Specifications -61
This is the product which uses a heavy-duty cord having flexible characteristics 5 times (SMC
comparison) as strong as oil resistant heavy-duty cord used in the standard products.

D 61

Solid state switch part no.


Oil resistant, flexible heavy-duty cord
Applicable part no: All the solid state specifications
switches with the
exceptance of D-J51,
output diagnostic type, Lead wire length
terminal conduit type, For lead wire length, refer to page 6-16-7.
connector type,
magnetic field resistant
type, heat resistant
type
Note) Oil resistant flexible
cabtire cord is used for
A A
D-Y59 B , Y69 B ,
Y7P(V) as standard. No
need to suffix -61 to the
end of part number.

Specifications are the same as standard products with the exception of lead wire specifications.
Lead wire: For D-F8, F9 type······ ø2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
For other model nos.··················· ø3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type. Lead wire diameter is changed from ø4 to ø3.4. In other series products,
it is common as standard product's specifications.

6-16-62
Technical Data 1:
Plug-in Connector Assembly/
How to Use DIN Terminal
Plug-in Connector Assembly How to Use DIN Terminal:
D-A44/A44A/A44C
D-A73C/A80C, D-J79C
D-C73C/C80C, D-H7C Connection procedure
1. Loosen the set screw and pull out the connector from the pin plug.
2. Be sure to remove the set screw first and then insert a screwdriver into a
recessed groove under the terminal block to separate the terminal cover
from the terminal block.
CJ1
3. Follow the procedures and connect wires securely to specified terminals.
Locking ring 4. In standard cases, crimp-style terminals are used to connect wires. CJP
Please select proper crimp-style terminals so that the wire can be
properly connected to terminal fittings.
CJ2
Sleeve How to connect
Connector
CM2
AC:
Connect to terminal no. 1 and no. 2
DC: CG1
Connect (+) to no. 1 terminal and (–) to no. 2 terminal.
MB
Fixing screw MB1
With the convex port of the connector, insert the connector into the auto Tightening gland
switch into the sleeve. Screw the locking ring onto the switch. CA2
(Do not tighten with pliers.)
CS1
Gland washer
C76
Gland gasket
Terminal cover C85
Terminal block
Terminal thread
C95
CP95
Terminal gasket

NCM
NCA
How to change position of electrical entry D-
After separating the terminal block from the terminal cover, change the
position of the terminal cover to any desired direction (4 directions at every
90°) to change the position of electrical entry. -X
Caution
When plugging a connector in the pin plug or pulling it out, hold a connector
perpendicularly as much as possible, not to slant it. 20-
Applicable cable (Heavy-duty cord)
Applicable to cable O.D. of ø6.8 to ø11.5. Data
Applicable crimp-style terminal
1.25Y-3L, 1.25-3.5S, 1.25-4M

6-16-63
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Band Mounting Style


Caution <Applicable auto switch>
1. Tighten the screw under the specified torque when mounting auto switch. Reed switch······D-C73, D-C76, D-C80, D-C73C, D-C80C
2. Set the mounting band perpendicularly to cylinder tube. Solid state switch······D-H7A1, D-H7A2, D-H7B, D-H7BAL
D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW
How to Mount and Move the Auto Switch
Mounting correctly Mounting incorrectly

<Applicable auto switch>


Reed switch······D-B53, D-B54, D-B64, D-B59W Auto switch
Solid state switch······D-G59, D-G5P, D-K59, D-G5BAL
D-G59W, D-G5PW, D-K59W, D-G59F, D-G5NTL
Auto switch mounting screw
How to Mount and Move the Auto Switch M3 x 0.5 x 14 l

Auto switch mounting bracket

Auto switch

Auto switch
Auto switch mounting
screw Auto switch mounting
M4 x 0.7 x 22 l screw
M3 x 0.5 x 14 l

Auto switch mounting band Auto switch mounting band


(With bracket) (With bracket)

1. Put a mounting band on the cylinder tube and set it at the auto switch 1. For Series CDJ2: Put a mounting bracket on the cylinder tube.
mounting the mounting hole to the hole of stationary fitting. For Series CDM2: Put a mounting band on the cylinder tube and set it at the
2. Put the mounting section of the auto switch between the band mounting holes, auto switch mounting position.
then adjust the position of mounting holes of switch to those of mounting band. 2. Put the mounting section of the auto switch between the band mounting holes,
3. Lightly thread the auto switch mounting screw through the mounting hole into then adjust the position of mounting holes of switch to those of mounting band.
the thread part of band fitting. 3. Lightly thread the auto switch mounting screw through the mounting hole into
4. After reconfirming the detecting position, tighten the mounting screw to secure the thread part of band fitting.
the auto switch. (The tightening torque of M4 screw should be about 1 to 1.2 4. Set the whole body to the detecting position by sliding, tighten the mounting
N·m.) screw to secure the auto switch. (Tightening torque of M3 screw should be 0.8
5. Modification of the detection position should be made in the condition of 3. to 1.0 N·m.)
5. Modification of the detection position should be made in the condition of 3.
6. After auto switch is mounted and fixed, attach a protective tube on the tip of an
Auto Switch Mounting Bracket Part No. auto switch mounting screw.
(Including band and screw)
Applicable bore size (mm) Auto Switch Mounting Bracket Part No.
Cylinder series
20 25 32 40 50 63 80 100
(Including band and screw)
CDM2, CDBM2 BA2 BA2 BA2 BA2 Cylinder Applicable bore size (mm)
— — — — series
CDVM3/5, CDLM2 -020 -025 -032 -040 6 10 15 16 20 25 32 40 50 63
CDG1, MGG BA BA-06 BA-08 BA-10 CDJ2 BJ2-006 BJ2 — — — — — — —
BA BA BA -010 BJ2
MGC -05 — — — CDVJ3/5 — — — — — — — —
-01 -02 -32 -016
CDLG1 BA — — — — CDLJ2 — — — — — — — — —
CDV3, CNA -04 BA BA BA BA CDM2, CDBM2 BM2 BM2 BM2 BM2
— — — — — — — — —
CDVS, CDL1, CE2 -05 -06 -08 -10 CDVM3/5, CDLM2 -020 -025 -032 -040
BA- BA- BA-
RHC, MLGC, REC 01 02 32 — — — — CDG1, MGG — — — — BMA2-050 BMA2-063
[Mounting screws set made of stainless steel] CDLG1 — — — — BMA2 BMA2 BMA2 — —
BMA2
The following set of mounting screws made of stainless steel is also available. MGC — — — — -020 -025 -032 BMA2-050 —
Use it in accordance with the operating environment. -040
RHC, MLGC, REC — — — — — —
(Please order the mounting band separately, since it is not included.)
BBA3: For D-B5/B6/G5/K5
RSDG — — — — — — — BMA2-050 —
[Mounting screws set made of stainless steel]
“D-G5BAL” switch is set on the cylinder with the stainless steel screws above
The following set of mounting screws made of stainless steel is also available.
when shipped.
Use it in accordance with the operating environment.
When a switch is shipped independently, “BBA3” screws are attached.
(Please order the mounting band separately, since it is not included.)
BBA4: For D-C7/C8/H7
“D-H7BAL” switch is set on the cylinder with the stainless steel screws above
when shipped.
When only a switch is shipped independently, “BBA4” screws are attached.
6-16-64
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> <Applicable auto switch>
Reed switch ···············D-A33, D-A34, D-A44 Reed switch ···············D-A33A, D-A34A, D-A44A
Solid state switch······D-G39, D-K39 Solid state switch······D-G39A, D-K39A
CJ1

How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch CJP
D-A3, D-G3/K3 type CJ2

Auto switch
CM2
Auto switch
mounting screw
Auto switch mounting screw M5 x 0.8 x 8 l CG1
M5 x 0.8 x 16 l
MB

Auto switch
MB1
Fook CA2
Auto switch mounting screw
Mounting band M5 x 0.8 x 8 l
CS1
D-A4 C76
Auto switch mounting band
(With bracket)
C85
Auto switch

C95
Auto switch mounting screw CP95
M5 x 0.8 x 16 l
1. Tighten completely the switch mounting screw on the switch body
side. NCM
2. Put a mounting band on the cylinder tube and set it at the auto
switch mounting position. Put the mounting section of auto switch
between the interval of mounting band, then adjust the position of NCA
mounting holes of switch to those of mounting band.
Fook
3. Lightly thread the auto switch mounting screw through the mounting
hole into the thread part of band fitting.
D-
Mounting band
4. After reconfirming the detecting position, tighten the mounting screw
to secure the auto switch. (The tightening torque of M5 screw -X
should be about 2 to 3 N·m.)
5. Modification of the detecting position should be made in the 20-
1. Loosen the auto switch mounting screws at both sides to pull down condition of 3.
the hook.
2. Put a mounting band on the cylinder tube and set it at the auto Data
switch mounting position, and then hook the band. Auto Switch Mounting Bracket Part No.
3. Screw lightly the auto switch mounting screw. (Including band and screw)
4. Set the whole body to the detecting position by sliding, tighten the
Applicable bore size (mm)
mounting screw to secure the auto switch. (The tightening torque Cylinder series
should be about 2 to 3 N·m.) 20 25 32 40
5. Modification of the detecting position should be made in the CDM2, CDBM2
BM3-020 BM3-025 BM3-032 BM3-040
condition of 3. CDLM2

Auto Switch Mounting Bracket Part No. (Band)


Cylinder Applicable bore size (mm)
series 20 25 32 40 50 63 80 100 125 140 160 180 200
CDV3, CDVS — — — — —
BD1 BD1 BD1 BD1 BD1
CE2, CNA — — — -04M -05M -06M -08M -10M
CDL1 BS1 BS1 BS1 — —
-125 -140 -160 BS1 BS1
CDS1 — — — — — — — — -180 -200

BD1 BD1 BD1 BD1


RHC -01M -02M -02 -04M — — — — — — — — —

BMB2 BMB2 BMB1 BMB1 BMB1 BMB1


MDB — — -032 -040 -050 -063 -080 -100 — — — — —

6-16-65
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch>
Reed switch ···············D-A72, D-A73, D-A80, D-A72H, D-A73H, D-A76H, D-A80H, D-A73C, D-A80C, D-A79W
Solid state switch······D-F79, D-F7P, D-J79, D-F7NV, D-F7PV, D-F7BV, D-J79C, D-F79W, D-F7PW, D-J79W,
D-F7NWV, D-F7BWV, D-F79F, D-F7BAL, D-F7BAVL, D-F7NTL
How to Mount and Move the Auto Switch

Auto switch mounting screw Auto switch mounting screw


(M3 x 0.5 x 8 l) (M3 x 0.5 x 8 l)

Auto switch

Auto switch mounting nut Auto switch mounting nut


(Square nut)

Auto switch mounting rail

Auto switch mounting screw


(M3 x 0.5 x 6 l) Auto switch mounting screw
(M3 x 0.5 x 10 l)
Auto switch
mounting nut
Auto switch spacer

Auto switch
mounting nut

1. Slide the auto switch mounting nut inserted into the mounting rail and 3. Push the auto switch mounting screw lightly into the mounting nut
set it at the auto switch mounting position. through the hole of auto switch mounting arm.
2. Fit the convex part of auto switch mounting arm into the concave part 4. After reconfirming the detecting position, tighten the mounting screw
of auto switch mounting rail. Then slide the switch over the nut. to secure the auto switch. (Tightening torque of M3 screw should be
(Series CDQ2: Fit the convex part of auto switch mounting arm 0.5 to 0.7 N·m.)
through the auto switch spacer into the concave part of auto switch 5. Modification of the detecting position should be made in the
mounting rail.) condition of 3.
Auto Switch Mounting Bracket Part No. (Including nut, screw, (spacer))
Applicable bore size (mm)
Cylinder series 40
12 16 20 25 32 50 63 80 100 125 140 160
CDQ2 BQ-1 BQ-1 BQ-1 BQ-1 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2
MDU — — — BMU1-025 BMU1-025 BMU1-025 BMU1-025 BMU1-025 — — — — —
RSDQ — — — — — — — —
BQ-1
MK, MK2 — — BQ-1 BQ-2 — — — — —
BQ-2 BQ-2 BQ-2
CE1 BQ-1 — — — — — — —
CXT — — — — — — — — — — —
[Mounting screws set made of stainless steel]
The set of stainless steel mounting screws (with nuts) described below is available and can be used depending on the operating environment.
(Please order the auto switch spacer, since it is not included.)
BBA2: For D-A7/A8/F7/J7
“D-F7BAL” switch is set on the cylinder with the stainless steel screws above when shipped.
When only a switch is shipped independently, “BBA2” screws are attached.

6-16-66
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch>
Solid state switch······D-P5DWL
CJ1
How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
Switch mounting bracket fixing screw CJP
Hexagon socket head cap bolt
Hexagon wrench key 2
M3 x 0.5 x 14 l CJ2
Hexagon socket head cap screw (M2.5 x 8 l )

Spring washer
CM2
Switch
mounting Magnetic field CG1
bracket resistant
auto switch
MB

Switch
MB1
mounting nut
CA2

Hexagon wrench key 2.5 CS1


Auto switch
Switch mounting screw Hexagon socket head cap screw (M3 x 16 l )
Round head Phillips screw C76
with spring washer
M3 x 0.5 x 16 l
C85
1. Mount the mounting bracket onto the mounting nut by tightening bracket 1. Insert the hexagon socket head cap screw (M2.5 x 0.45 x 8 l) down lightly
fixing screw lightly through the mounting hole on the top of bracket. to the M2.5 tapped portion of the lower part of switch mounting bracket's C95
2. Insert the mounting bracket assembly (bracket + nut) into the mounting concave part. (2 locations) Use caution to avoid the tip of a screw from
groove and set it at the auto switch mounting position. sticking out of the switch mounting bracket's bottom surface.
3. Push the auto switch mounting screw lightly into the auto switch through 2. Install a spring washer in the hexagon socket head cap bolt (M3 x 0.5 x CP95
the mounting hole to secure. 16 l), then put it through the part of through-holes (2 locations) of an auto
4. After reconfirming the detecting position, tighten the mounting screw to
secure the mounting bracket and the auto switch. (Tightening torque
switch. NCM
3. As for switch mounting bracket, slightly thread the hexagon socket head
should be 0.5 to 0.7 N·m.) cap screw w into M3 tapped portion. (2 locations)
4. Fit the switch mounting bracket into the switch mounting groove on the NCA
cylinder body, and then slide it to the detection position roughly.
5. After reconfirming the detecting position, tighten the mounting screw to
secure the auto switch. D-
-X
Auto Switch Mounting Bracket Part No. Auto Switch Mounting Bracket Part No.
(Including bracket, screw) (Including bracket, screw) 20-
Applicable bore size (mm) Applicable bore size (mm)
Cylinder series Cylinder series Data
40 50 63 80 100 40 50 63 80 100
CDQ2 BQP1-050 BQP1-050 BQP1-050
BQP1-050 BQP1-050 MGP, MLGP BMG1-040 BMG1-040 BMG1-040 BMG1-040 BMG1-040
MK, MK2 — —

Caution
Auto Switch Mounting Tool
• When tightening hexagon socket head cap screw of an auto switch, use a
hexagon wrench key 2 and 2.5, depending on the case.

Tightening Torque
• As a guide, set approximately 0.3 to 0.5 N·m for M2.5, 0.5 to 0.7 N·m for
M3 respectively.

6-16-67
How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch>
Solid state switch······D-P5DWL

How to Mount and Move the Auto Switch

Hexagon socket head cap screw


With spring washer, M3 x 0.5 x 5 l Switch mounting bracket
Auto switch
Flat washer
ø8 x ø3.3 x t0.8 Round head Phillips screw
With spring washer,
M3 x 0.5 x 14 l

Switch mounting nut

1. From the cutoff part of the rail on the cylinder body, insert the switch
mounting nuts (2 pcs.) into the rail groove.
2. Slide the switch mounting nuts (2 pcs.) and set into the auto switch
mounting position roughly. (25 mm or more should be left for the distance
between 2 nuts.)
3. Insert the convex portion of the switch mounting bracket into the concave
portion of a rail groove. Through-hole for the switch mounting bracket
should be placed on the switch mounting nut.
4. Put a flat washer (ø8 x ø3.3) through a hexagon socket head screw (with
spring washer, M3 x 0.5 x 5 l) and passing through the hole of a switch
mounting bracket, then turning it lightly down to a mounting nut of switch.
(2 locations)
5. Put a round head Phillips screw (with spring washer, M3 x 0.5 x 14 l)
through the auto switch's through-hole (2 locations), and then push it
down into the M3 tapped part on the switch mounting bracket while
turning it lightly.
6. After reconfirming the detecting position, tighten the mounting screw to
secure the mounting bracket and the auto switch. (Tightening torque of
M3 screw should be 0.5 to 0.7 N·m.)

Auto Switch Mounting Bracket Part No.


(Including bracket, screw)
Applicable bore size (mm)
Cylinder series
40 50 63
MDU BMU2-040 BMU2-040 BMU2-040

6-16-68
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> <Applicable auto switch>
Reed switch···············D-A53, D-A54, D-A56, D-A64 Reed switch ···············D-A33C, D-A34C, D-A44C
D-A67, D-A59W Solid state switch······D-G39C, D-K39C
Solid state switch······D-F59, D-F5P CJ1
D-J59, D-J51, D-F5BAL How to Mount and Move the Auto Switch
D-F59W, D-F5PW, D-J59W CJP
Auto switch mounting screw
D-F59F, D-F5NTL (With hexagon socket head)
M5 x 0.8 CJ2
How to Mount and Move the Auto Switch CM2
Auto switch
Bracket set screw
(With hexagon socket head) CG1
Auto switch mounting screw (M4) M5 x 0.8 x 12 l

Mounting bracket (A) MB


MB1
Auto switch CA2
Auto switch mounting bracket
Set screw (M4)
CS1
C76
Mounting
Tie-rod bracket (b)
C85
Auto switch mounting screw
(With hexagon socket head)
M5 x 0.8
C95
CP95
Auto switch

Bracket set screw


NCM
M5 x 0.8 x 12 l
NCA
Mounting bracket (A)
1. Fix the auto switch on the auto switch mounting bracket with the
D-
mounting screw (M4) and install the set screw.
2. Fit the mounting bracket into the cylinder tie-rod and then fix the auto -X
switch at the detecting position with the hexagonal wrench. (Be sure
to put the auto switch on the surface of cylinder tube.)
3. When changing the detecting position, loosen the set screw to move
20-
the auto switch and then re-fix the auto switch on the cylinder tube.
(Tightening torque of M4 screw should be 1 to 1.2 N·m.) Data
Auto Switch Mounting Bracket Part No.
(Including bracket, set screw) Mounting
Cylinder Applicable bore size (mm) bracket (b)
series 32 40 50 63 80 100 125 140 160 180 200
CDV3, CDVS 1. Fix the mounting bracket (A) on the auto switch with the set screw.
— BT BT BT BT BT — — — — — 2. Fit the concave part of mounting bracket into tie-rod and set the auto
CE2, CNA
-04 -04 -06 -08 -08 switch at the mounting position.
CDL1 — BT BT BT — —
— — — — — — -12 -12 -16 -18A BT BT 3. Insert the mounting bracket (B) from the underneath and put lightly in
CDS1 -20
the tie-rod with the mounting screw.
MDB, MDBB BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 — — — — —
4. Set the whole body to the detecting position by sliding, tighten the
[Mounting screws set made of stainless steel] mounting screw to secure the auto switch. (Tightening torque of M5
The following set of mounting screws made of stainless steel is also screw should be 2 to 3 N·m.)
available. Use it in accordance with the operating environment. 5. Modification of the detecting position should be made in the
(Please order the mounting band separately, since it is not included.)
condition of 3.
BBA1: For D-A5/A6/F5/J5
“D-F5BAL” switch is set on the cylinder with the stainless steel screws Auto Switch Mounting Bracket Part No.
above when shipped. (Including bracket, screw)
When a switch is shipped independently, “BBA1” screws are attached. Applicable bore size (mm)
Cylinder series
40 50 63 80 100
BA3 BA3 BA3 BA3 BA3
CDV3, CDVS, CDL1, CE2, CNA
-040 -050 -063 -080 -100

6-16-69
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> <Applicable auto switch>
Reed switch·············· D-Z73/Z76/Z80 Solid state switch······D-P5DWL
Solid state switch····· D-Y59 AB /Y69 AB , D-Y7P(V) How to Mount and Move the Auto Switch
D-Y7NW(V)/Y7PW(V)/Y7BW(V)
D-Y7BAL MDB, MDBB, MDNB
Hexagon socket head cap screw
How to Mount and Move the Auto Switch M4 x 0.7 x 8 l
Switch mounting bracket

Watchmakers’ (precision) screwdriver

Hexagon socket head set screw


Series MB, CA1: M4 x 0.7 x 6 l
Series CS1: M4 x 0.7 x 8 l
Auto switch
Tie-rod
Auto switch
Hexagon socket head cap bolt
Auto switch CDNA, M3 x 0.5 x 14 l
mounting screw CDL1, (ø40 to ø100)
Hexagon socket head set screw
M4 x 0.7 x 6 l
Switch mounting bracket
Switch mounting bracket

Note) When tightening an auto switch mounting screw, use a Auto switch
watchmaker’s screwdriver with a grip diameter of 5 to 6 mm.
Also, set the tightening torque to be 0.05 to 0.1 N·m. Tie-rod
As a guide, turn 90° from the position where it comes to feel
tight. Set the tightening torque of a hexagon socket head set Round head Phillips screw
screw (M4 x 0.7) to be 1 to 1.2 N·m. With spring washer, M3 x 0.5 x 14 l
1. Fix it to the detecting position with a set screw by installing a mounting
bracket in cylinder tie-rod and letting the bottom surface of a mounting 1. (For MDB)
bracket contact the cylinder tube firmly. Slightly screw the hexagon socket head cap screw (M4 x 0.7 x 8 l) into
the M4 tapped portion of switch mounting bracket. (2 locations) Use
(Use hexagon wrench)
caution that the tip of the hexagon socket head cap screw should not
2. Fit an auto switch into the switch mounting groove to set it roughly to the stick out to the concave portion of switch mounting bracket.
mounting position for an auto switch. 2. (For MDB)
3. After confirming the detecting position, tighten up the mounting screw Put a round head Phillips screw (M3 x 0.5 x 14 l) through the auto
attached to an auto switch, and secure the switch. switch's through-hole (2 locations), and then push it down into the M3
4. When changing the detecting position, carry out in the state of 2. tapped part on the switch mounting bracket while turning it lightly.
3. Place the concave part of the switch mounting bracket into the cylinder
∗ To protect auto switches, ensure that main body of an auto switch should tie-rod, and slide the switch mounting bracket in order to set roughly to
be embedded into auto switch mounting groove with a depth of 15 mm or the detecting position.
more. 4. After reconfirming the detecting position, tighten the M3 mounting screw
to secure the auto switch by making the bottom face of auto switch
attached to the cylinder tube. (Tightening torque of M3 screw should be
Auto Switch Mounting Bracket Part No. 0.5 to 0.7 N·m.)
Applicable cylinder 5. Tighten up M4 screw of switch mounting bracket to secure the switch
Bore size (mm) Mounting Accessory
mounting bracket. (Ensure that tightening torque of M4 screw should be
32, 40 BMB4-032 set 1.0 to 1.2 N·m.)
MDB, MBB, MDNB 50, 63 BMB4-050 Hexagon
80, 100 BA4-063 socket head
set screw Auto Switch Mounting Bracket Part No.
40, 50 BA4-040 (M4 x 0.7 x 6 l) (Including bracket, screw)
CDL1, CDNA 63 BA4-063 Quantity: 2 Applicable bore size (mm)
80, 100 BA4-080 Cylinder series
32 40 50 63 80 100
125, 140 BS4-125 Hexagon MDB, MDBB, MDNB BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080
160 BS4-160 socket head CDL1, CDNA — BAP2-040 BAP2-040 BAP2-063 BAP2-080 BAP2-080
CDS1, CDL1, CDLS set screw
180 BS4-180 (M4 x 0.7 x 8 l)
200 BS4-200 Quantity: 2

6-16-70
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> <Applicable auto switch>
Reed switch······D-90/97, D-90A/93A Reed switch···············D-E73A/E76A/E80A
Solid state switch······D-M5N/M5P/M5B CJ1
D-M5NW/M5PW/M5BW
How to Mount and Move the Auto Switch D-M5NTL/M5PTL CJP
How to Mount and Move the Auto Switch
Auto switch
CJ2
CM2
Auto switch mounting bracket

Set screw CG1

Note) The tightening torque of set screw


Auto switch mounting nut MB
should be about 0.5 to 0.6 N·m.
MB1
Auto Switch Mounting Bracket Part No. Auto switch mounting screw CA2
(Including bracket, screw) M2.5 x 10 l (D-E7A/E8A)
Cylinder Applicable bore size (mm) M2.5 x 12 l (D-M5/M5W/M5T)
series 6 10 15
CS1
1. Insert the auto switch mounting nut into the auto switch mounting
CDJP-D BP-1 BP-1 BP-1 groove and then set the switch at the mounting position by sliding.
2. Put the convex part of auto switch into the mounting groove and C76
<Applicable auto switch> slide it over the nut.
Reed switch·················D-A90(V)/A93(V)/A96(V) 3. Push the auto switch mounting screw lightly into the mounting nut C85
through the mounting hole.
Solid state switch········D-M9N(V)/M9P(V)/M9B(V) 4. After reconfirming the detecting position, tighten the mounting screw
F9NW(V)/F59W/F9BW(V) to secure the auto switch. (Tightening torque of M2.5 screw should C95
F9BAL be 0.1 to 0.2 N·m.)
Auto Switch Mounting Bracket Part No. (Including nut, screw) CP95
How to Mount and Move the Auto Switch Cylinder Applicable bore size (mm)
series 25 32 40 NCM
M2.5 x 12l BMY2-025 BMY2-025 BMY2-025
ML1 NCA
Set screw M2.5 x 10l BMY1-025 BMY1-025 BMY1-025

<Applicable auto switch> D-


Reed switch···············D-Z73/Z76/Z80
A A
Solid state switch······D-Y59 B /Y69 B , D-Y7P(V) -X
Auto switch D-Y7NW(V)/Y7PW(V)/Y7BW(V)
D-Y7BAL 20-
How to Mount and Move the Auto Switch
• When tightening an auto switch mounting
screw, use a watchmaker’s screwdriver with Data
a grip diameter of 5 to 6 mm. The tightening Note) When tightening an auto
Auto switch mounting screw
switch mounting screw, use a
torque should be about 0.1 to 0.2 N·m.
watchmaker’s screwdriver with a M2.5 x 4 l
grip diameter of 5 to 6 mm. Also,
set the tightening torque to be
0.05 to 0.1 N·m. As a guide, turn
90° from the position where it
comes to feel tight.

1. Insert the auto switch into the mounting groove and set it at the auto
switch mounting position.
2. After reconfirming the detecting position, tighten the mounting screw
to secure the auto switch.
3. Modification of the detecting position should be made in the
condition of 1.

6-16-71
Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Direct Mounting Style


<Applicable auto switch>
Reed switch··············· D-Z73/Z76/Z80
Solid state switch······D-Y59 AB /Y69AB , D-Y7P(V)
D-Y7NW(V)/Y7PW(V)/Y7BW(V)
D-Y7BAL

How to Mount and Move the Auto Switch

Flat head watchmakers’ screwdriver


Switch mounting screw (M2.5 x 4 l )
Accessory

ø5
to
ø6
Switch spacer

Note) When tightening an auto switch


mounting screw, use a watchmaker’s
screwdriver with a grip diameter of 5 to
6 mm. Also, tighten with a torque of
about 0.05 to 0.1 N·m
As a guide, it should be turned about
90° past the point at which tightening
can be felt.
When attaching an auto switch, first take a switch spacer between your
fingers and press it into a switch mounting groove. When doing this, confirm
that it is set in the correct mounting orientation, or reattach if necessary.
Next, insert an auto switch into the groove and slide it until it is positioned
under the switch spacer.
After establishing the mounting position, use a watchmakers flat head
screwdriver to tighten the switch mounting screw which is included.

Correct Incorrect

Switch Spacer No.


Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100
MDB1 BMP1-032

6-16-72
Series D-P3DW
Mounting and Moving Method of Auto Switch
Direct Mounting to the Round Groove Direct Mounting to the Square Groove
Auto switch Auto switch
Applicable cylinder/actuator mounting bracket Applicable cylinder/actuator mounting bracket
part no. part no.
CDQS ø25 (ø0.98)∗ MGP ø25 to ø100 (ø0.98 to ø3.94)∗
Compact cylinder Compact guide cylinder
CDQ2 ø32 to ø100 (ø1.26 to ø3.94)∗ MGPS ø50, ø80 (ø1.97, ø3.15)∗ BMG5-025S
Compact cylinder with lock CDLQ ø25 to ø100 (ø0.98 to ø3.94)∗ BQ3-032S Compact guide cylinder with lock MLGP ø25 to ø100 (ø0.98 to ø3.94)∗
Pin clamp cylinder CKQG ø50 (ø1.97)∗ ∗ Equivalent inch size.
Pin clamp cylinder with lock CLKQG ø50 (ø1.97)∗ Note) For the MGP end lock type, as the auto switch cannot be mounted
onto the lock mechanism face, mount it to the groove on the bottom
∗ Equivalent inch size. of the lock mechanism face.
Note) When the auto switch is mounted onto the CDBQ2 end lock type,
please contact SMC. Mounting and Moving Method of D-P3DW (2)
q Insert the protrusion on the bottom of the auto switch into the mating
Mounting and Moving Method of D-P3DW (1)
part of the auto switch mounting bracket and fix the auto switch and
q Insert the protrusion on the bottom of the auto switch into the mating part the auto switch mounting bracket temporarily by tightening the
of the auto switch mounting bracket and fix the auto switch and the auto hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
switch mounting bracket temporarily by tightening the hexagon socket
w Insert the temporarily tightened mounting bracket into the mating
head cap screw (M2.5 x 9 L) 1 to 2 turns.
groove of the cylinder/actuator, and slide the auto switch onto
w Insert the temporarily tightened mounting bracket into the mating the cyinder/actuator through the groove.
groove of the cylinder/actuator, and slide the auto switch onto the
e Check the detecting position of the auto switch and fix the auto
cylinder/actuator through the groove.
switch firmly with the hexagon socket head cap screw (M2.5 x 6
e Check the detecting position of the auto switch and fix the auto switch L, M2.5 x 9 L).∗
firmly with the hexagon socket head cap screw (M2.5 x 6 L, M2.5 x 9 L).∗
r If the detecting position is changed, go back to step w.
r If the detecting position is changed, go back to step w.
∗ The hexagon socket head cap screw (M2.5 x 6 L) is used to fix the
∗ The hexagon socket head cap screw (M2.5 x 6 L) is used to fix the mounting mounting bracket and cylinder/actuator.
bracket and cylinder/actuator. This enables the replacement of the auto switch without adjusting the auto
This enables the replacement of the auto switch without adjusting the auto switch position.
switch position.
Note 1) Ensure that the auto switch is covered with the mating groove to
Note 1) Ensure that the auto switch is covered with the mating groove to protect protect the auto switch.
the auto switch. Note 2) The torque for tightening the hexagon socket head cap screw (M2.5
Note 2) The torque for tightening the hexagon socket head cap screw (M2.5 x 6 L, x 6 L, M2.5 x 9 L) is 1.77 to 2.66 in-lb.
M2.5 x 9 L) is 1.77 to 2.66 in-lb. Note 3) Tighten the hexagon socket head cap screws evenly.
Note 3) Tighten the hexagon socket head cap screws evenly.

Hexagon socket head cap screw


(M2.5 x 9 L)

Hexagon socket head cap screw


(M2.5 x 9 L)
Hexagon socket head cap screw
(M2.5 x 6 L) Convex part

Hexagon socket head cap screw


BQ3-032S Note) (M2.5 x 6 L) Convex part

Auto switch mounting bracket

BMG5-025S Note)

Note) When the auto switch


Auto switch mounting bracket
mounting bracket is
ordered by its part number,
it includes the bracket and
screws in the dashed line.

Precautions for the Cylinder/Actuator Mounting


• When mounting the D-P3DW onto a cylinder/actuator with ø1.26 to
ø1.97, to avoid mutual interference, use a fitting with width across flats
0.47 inch or less for ø1.26 and ø1.58, and use a fitting with width across Note) When the auto switch mounting
flats 0.55 inch or less for ø1.97. Also, if the corner of the fitting interferes bracket is ordered by its part
with the housing of the auto switch, adjust the tightening of the fitting to number, it includes the bracket
eliminate the interference. In the case of interference with an elbow type and screws in the dashed line.
fitting, direct the port of the fitting away from the auto switch. Such
interference must be avoided especially when a speed controller and
speed exhaust controller with a fitting are selected.
• In the CDQSø0.98 and CDLQø0.98, the auto switch will interfere with
the fitting if mounted onto the face with the port, so it needs to be
mounted on a different face.

7
Series D-P3DW 
Magnetic Field Resistant
2-Color Display Solid State Auto Switch

Rod Mounting Type 1 Rod Mounting Type 2


Applicable cylinder/actuator Applicable cylinder/actuator
Clamp cylinder CKG1 ø40 to ø63 (ø1.58 to ø2.48)∗ MDB ø80 to ø125 (ø3.15 to ø4.92)∗
Air cylinder
Clamp cylinder with lock CLK2G ø40 to ø63 (ø1.58 to ø2.48)∗ CDA2 ø63 to ø100 (ø2.48 to ø3.94)∗
MDB ø32 to ø63 (ø1.26 to ø2.48)∗ MDNB ø80 to ø100 (ø3.15 to ø3.94)∗
Air cylinder Air cylinder with lock
CDA2 ø40, ø50 (ø1.58, ø1.97)∗ CDNA ø63 to ø100 (ø2.48 to ø3.94)∗
MDNB ø32 to ø63 (ø1.26 to ø2.48)∗ ∗ Equivalent inch size.
Air cylinder with lock
CDNA ø40, ø50 (ø1.58, ø1.97)∗ Mounting and Moving Method of D-P3DW (4)
∗ Equivalent inch size. q Install the auto switch mounting bracket 2 to the tie-rod, and fix it
Mounting and Moving Method of D-P3DW (3) to the approximate mounting position with the cone points of
q Insert the protrusion on the bottom of the auto switch into the hexagon socket head cap screw (M4 x 8 L) while keeping firm
mating part of the mounting bracket and fix the auto switch by contact between the bottom of the auto switch mounting bracket 2
tightening the hexagon socket head cap screw (M2.5 x 9 L). and the cylinder tube.
w Install the mounting bracket on which the auto switch is mounted to w Insert the protrusion on the bottom of the auto switch into the mating
the switch mounting rod, and move it to find the detecting position part of the auto switch mounting bracket 1 and fix the auto switch and
while keeping firm contact between the bottom of the auto switch the auto switch mounting bracket 1 temporarily by tightening the
mounting bracket and the cylinder tube. hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
e After checking the detecting position, fix the auto switch mounting e Insert the temporarily tightened mounting bracket 1 to the mating
bracket to the detecting position with the cone points of hexagon groove of the mounting bracket 2, and fix the auto switch by
socket head cap screw (M4 x 8 L). tightening the hexagon socket head cap screw (M2.5 x 6 L and
r If the detecting position is changed, go back to step w). M2.5 x 9 L) after checking the detecting position.
r If the detecting position is changed, go back to step q or e).
Note 1) When tightening the cone points of hexagon socket head cap screw (M4 x
8 L), keep the tightening torque within 8.85 to 10.6 in-lb. Note 1) Ensure that the auto switch is covered with the mating groove by a
Note 2) The torque for tightening the hexagon socket head cap screw (M2.5 x 9 minimum of 0.59 inch to protect the auto switch.
L) is 1.77 to 2.66 in-lb. Note 2) When tightening the cone points of hexagon socket head cap screw (M4 x
Note 3) Tighten the hexagon socket head cap screws evenly. 8 L), keep the tightening torque within 8.85 to 10.6 in-lb.
Note 3) The torque for tightening the hexagon socket head cap screw (M2.5 x
Hexagon socket head cap screw 6 L, M2.5 x 9 L) is 1.77 to 2.66 in-lb.
(M2.5 x 9 L) Note 4) Tighten the hexagon socket head cap screws evenly.
Auto switch Hexagon socket head cap screw
(M2.5 x 9 L)
Convex part
Auto switch
Auto switch mounting bracket Cone points of hexagon Cone points of hexagon Convex part
socket head cap screw socket head cap screw
(M4 x 8 L) (M4 x 8 L)

BMB8-0S Note) Auto switch mounting bracket 2


Auto switch mounting
bracket 1
BA7T-0S Note)
Switch mounting rod
Hexagon socket
head cap screw
(M2.5 x 6 L)

Tie-rod
Note) When the auto switch mounting
bracket is ordered by its part
number, it includes the bracket
and screws in the dashed line.
Note) When the auto switch mounting
bracket is ordered by its part
Auto Switch Mounting Bracket Part No. for CK Series number, it includes the bracket
and screws in the dashed line.
(Including Bracket and Screws)
Bore size Auto Switch Mounting Bracket Part No. for MB Series
Series (Including Bracket and Screws)
40 (1.58)∗ 50 (1.97)∗ 63 (2.48)∗
Bore size
CKG1
BMB8-050S Series 32 40 50 63 80 100 125
CLK2G
(1.26)∗ (1.58)∗ (1.97)∗ (2.48)∗ (3.15)∗ (3.94)∗ (4.92)∗
∗ Equivalent inch size.
Auto Switch Mounting Bracket Part No. for CA Series MDB BMB8-032S BMB8-050S BA7T-063S BA7T-080S
(Including Bracket and Screws) MDNB (1.26 to 3.94)
Bore size ∗ Equivalent inch size.
Series
40 (1.58)∗ 50 (1.97)∗ 63 (2.48)∗ 80 (3.15)∗ 100 (3.94)∗
Note) Differences in color and glossiness of the metal surface treatment do not
affect the performance. Due to the characteristics of the chromate
CDA2 BMB8-050S BA7T-063S BA7T-080S treatment (trivalent) applied to the whole body of the auto switch mounting
CDNA bracket, the color may be slightly different between manufacturing lots.
∗ Equivalent inch size. However, this will not reduce the corrosion resistance.