You are on page 1of 28
| PEB Metal Mis (OvGlity Steel Buildings gms “OUR MOTTO IS TO EXECUTE PROJECTS WITHIN COMMITTED SCHEDULE AND SATISFACTORY SERVICES AT ALL THE TIME...” STcluhir-lel Rela Vaiaa (aoe ler CONTENT BRIEF INTRODUCTION VISION, MISSION AND VALUE PRE-ENGINEERED BUILDING SYSTEM COMPARISION WITH CONVENTIONAL, MATERIAL OFFERED AND TECHNICAL SPECIFICATION DESIGN CODE AND PRACTICES PRE ENGINEERED BUILDING PROCESS PEB PLANT PROCESS DESIGN AND ENGINEERING BASIC BUILDING PARAMETERS PRIMARY FRAMING SYSTEM MEZZANINE AND CRANE DETAIL STRUCTURAL SUBSYSTEMS STANDARD FLASHING AND TRIMS PRIMARY PRODUCTION FLOW OUR PROJECTS QUALITY CONTROL AND SAFETY TURNKEY PROJECT MANAGEMENT Brief Introduction PEB Metal specializes in the Design,Engineering, Fabrication Supply and Erection of pre engineered steel buildings for factories, warehouses, showrooms, sport stadiums, exhibition halls, aircraft hangars, Multistories Steel Buildings ete. PEB Metal Buildings Private Limited is established by an individual professional over 20 years of rich experience in design, Engineering, Business Development, Sales & Marketing, Fabrication, Project Management, Client Servicing and Developing excellent customer relationship At PEB Metal , our management team has worked from the inception of our project and have established the foundations of our businesses and its operations. A team of similar mindsets came together to form this company having reach experience from different department in Pre-Engineered steel building system used for industrial, warehousing and various other applications, Objective behind this establishment is to provide end to end solution to the custom- er by providing good quality products, safe execution at site and timely delivery of the projects So whether your project is new or an expansion into a larger facility, PEB Metal stands ready to help you to meet your steel building construction needs VISION, MISSION AND VALUES Our Vision PEB Metal to be recognized as the preferred vendor in the pre engineered building market. This be acl -ved through good response time, optimized design, quality assurance,timely delivery ,project co-ordination and the best customer services in the industry OUR MISSION + Keep update with the latest technology of the PEB industry, such as , tools, machinery, handling equipment and engineering software. + Team based organization and not owner based + Work closely with local Architects structural consultants, arrange seminars and presentation explaining in detail the PEB, and the design software application. + To provide customer with the most convenient and cost-effective source for basic high-quality pre-engineered steel buildings and related construction products. + Our success is measured by how well we satisfy our customer's needs, and we are committed to remaining accessible and responsive to them at all time. + Our success is measured by how well we satisfy our customer's needs and we are committed to remaining accessible and responsive to them OUR VALUES + We are very much transparent truthful and honest in our communications while dealing with Clients Structural Consultants Contractors,etc. + We partner with our clients to achieve smooth execution of the project and consider it our project + Focus on Continuous improvement in products and services. + Customer service makes all the difference; customers are lifetime partners; always seek a win - win solution. + The longest journey begins with the smallest step so begin with the end in mind and focus on the long term instead of short term. + Business tie-ups with local alliances + Partnering with our suppliers for mutual success Cl SU Ce Rane LCE PRE-ENGINEERED BUILDING SYSTEMS APPLICATION - Industrial Buildings - Warehouses - Commercial Complexes - Showrooms - Offices - Schools - Indoor Stadiums : PERSO - Outdoor Stadiums with canopies - Gas Stations - Metro Stations, Bus Terminals, Parking Lots - Primary Health Centers, Angan wadi’s - And many more... 3 ee COMPARISION WITH CONVENTIONAL Pre-Engineered vs Conventional Steel Buildings Steel Buildings Feature PreEngineered Building Conventional Weight | Weight is approx. 30 % less Weight is heavier Design | Design is quick & Efficient Design is complex Fuwe Expansion Not possible Quality ‘Not good quality Delivery Aprox. 20 to 24 weeks Space | Spaciuos due to large bay spacing and It occupies more space (Civil Foundation Safety Measures & responsibility Erection Seismic Resistance Aesthetics Relocatable Maintenance Cost Accessories tapered section ‘Simple design, Easy to construct & light weight Single source of supply and factory controlled quality results in complete quality ‘Since connections of the component is standard , so erection becomes simple | The low weight flexible frames offer higher resistance to seismic forces Use of fascias,curved eave & canopies add aesthetics to the buildings It can shift from one place to other Very Low Only periodical maintenance of gutters is required Turbo VentsRIDGE Vents, Louvers,Roof Monitors can easily accommodated Foundation is heavier Multiple sources of different components ,so results in more scope of delays and lacking in safety and responsibility ‘Connections differ from project to project, which leave scope for complications ‘Dueto heavy weight frames, Conventional buildings doesn't perform in seismic zone Not appearing good Can't relocate Very High Difficult to accommodate accessories MATERIAL OFFERED & TECHNICAL SPECIFICATION S.No. Materials Specifications Yield strength 1 Built-up Members ASTM AS72M GrSO (Approved Fy =345 MPa Indian make) Equivalent to IS 2062 2 Hot Rolled Secondary | IS: 2062 Gr. A (Approved Indian Fy=250 MPa Members make) 3. Cold Formed Secondary ASTM A 570 M GrSO (Approved Fy =345 MPa Members Indian make) 4, Sheeting Panels ASTM A 792 (Approved indian Fy= 550 Mpa Make) 5S. X-Bracing Members, Rods IS : 2062 Gr A (Approved Indian Fy=250 MPa make) 6. Anchor Bolts IS : 2062 Gr A (Approved Indian Fy =250 MPa make) 7. High Strength Bolts for ASTM A 325 M- ANSI 18.2.3.7/ - Primary Connections. 18.2.3.6 M (Approved Indian make) 8. Machine Bolts for IS : 1364 Class 4.6 (Part 1 to 3) - Secondary Connections. (Approved Indian make) 9 Self Drilling Self Tapping AS 3566.1 - 2002 Corrosion - Screws Resistance Class -3 (Approved Indian make) DESIGN CODES AND PRACTICES Our Buildings are designed in compliance with the latest design and building codes (IBC 2009, MBMA 2006, AISC 2005, AWS 2008) PEB Metal engineering team complies with USA's latest applicable design and building codes for the design and fabrication of its products. PEB Metal is proud to be using design and detailing software that is developed and sold by "Metal Building Software" (MBS), a USA based company that specializes in one product only, software for the design and drafting of PEB's. HOWEVER LIVE LOAD ,SEISMIC ZONE IS CONSIDERED AS INDIAN STANDARD CODE + Wind Speed : As per IS 875- Part II + Seismic Zone : As per IS 1893 + Load Combinations : As per IS 800-2007 or AISC depends on client requirement HOT ROLLED AND BUILT UP SECTIONS ARE DESIGNED IN ACCORDANCE WITH: Manual of Steel Construction, 13th Edition, LOADS ARE APPLIED IN ACCORDANCE WITH: 2005 The 2006 Edition of Low Rise Building System Manual American Institute of Steel Construction (AISC) Metal Building Manufactures Association (MBMA) —_ East Wecker Drive, Suite 3100,Chicago, Ilinois 1300 Sumner Ave,Cleveland,Ohio 44115 60601-2001 The design live load and wind load and load All strength calculations are made as per combinations shall be as per Allowable stress Design (ASD) above mentioned manual, of AISC manual. COLD-FORMED MEMBERS ARE DESIGNED IN WELDING IS APPLIED IN ACCORDANCE WITH: ACCORDANCE WITH American Welding Society (AWS 2002 Edition of Cold formed Steel Design D1.1/D1.1M:2008) Manual Structural Welding Code - Stee! American Iron and Steel Institute (AISI) 550 ,N W Lejeune Road 1000 16th Street ,NW,Wahington DC 20036 All cold formed steel structure shall be designed as per above mentioned code. PRE ENGINEERED BUILDING PROCESS PEB PLANT PROCESS DESIGN AND ENGINEERING We use state-of-the-art metal building software to design all our buildings Custom developed tools, complete fabrication drawings and shop drawings generated for each building Cater to the extensive manufacturing and automated machinery, keeping in mind, time and cost targets PEB Metal design operates with a team of more than 15 dedicated professionals and senior structural designers We use some of the most advanced software’s for detailed design which are at par with in- ternational building design standards cena Basic Building Parameters Pre-engineered buildings are defined by the following basic param- eters: Building Width, Length, Height, Roof Slope, End Bay Length, Interior Bay Length and Design Loads. Building Width No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one sidewall to outside of eave strut of the opposite sidewall. Building Length Building length is the distance between the outside flanges of endwall columns in opposite endwalls. It is a combination of several bay lengths. Building Height Building height is the eave height, which is usually the distance from the bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from the finished floor, eave height is the distance from the finished floor level to the top of the eave strut. Roof Slope (x/10) This is the angle of the roof with respect to the horizontal. The most common roof slopes should not be less than 0.5/10. Any practical roof slope is possible. End Bay Length This is the distance from the outside of the outer flange of endwall columns to the center line of the first interior frame column. Interior Bay Length This is the distance between the center lines of two adjacent interior main frame columns. The most common bay lengths are 6, 7.5, and 9 meters. Any bay length is possible up to 15 meters. For bay lengths above 9.0 M Normally Jack Beams are used Design Loads Unless otherwise specified, Pre-Engineered Buildings are designed for the following minimum loads: Roof Live Load: 0.57 kN/m2 Design Wind Speed: As per IS : 875 Part Ill depends on job site location Design parameters of snow loads, earthquake loads, collateral loads, craneloads or any other loading condition must be specified when re- questing a quotation. Loads are applied in accordance with American codes and standards applicable to pre-engineered buildings unless other- wise requested at the time of quotation. 4 ty = = =7}_4 mm | oonSon| game | some |___ one = DULG ENT a = » ROE oS vemee, geen, | OC ERECTION PROCESS “OUR MOTTO IS TO EXECUTE PROJECTS WITHIN COMMITTED SCHEDULE AND SATISFACTORY SERVICES AT ALL THE TIME...” PRIMARY FRAMING SYSTEM Asymmetrical and non-equal Multi-span Framing Systems are also available. Please consult with your Peb Metal representative nearest to you about your specific project requirements ‘MULTI-SPAN “1” (TCMS-1) CLEAR SPAN (CS) MULTI-SPAN “2” (MS-2) SINGLE SLOPE (SCCS) ‘MULTI-SPAN “3” (MS-3) ‘MULTI SPAN “1” (MS-1) MULTI GABLE (MG) MULTI-SPAN EOT CRANE WITH MAZZANINE FLOOR ROOF SYSTEM MEZZANINE & CRANE DETAILS Mezzanine Deck Panel Mezzanine Beam BUILDING PLAN SECTION WITH MEZZANINE & CRANE SECTION WITH CRANE Email Id : info@pebmetal.in | Website : www.pebmetal.in SUC UMTS ATES canopy Curved Eave with Projection ‘Gwithout valley gutter) — i) r ROOF MONITOR ad, ba I 4 Ly} ™ ee METAL ROOF SHEET & WALL CLADDING STRUCTURAL SUBSYSTEMS PARAPET FASCIA 9” BOTTOM CURVED FASCIA ‘CURVED EAVE ‘CURVED EAVE WITH PROJECTION OTHER COMPONENT OF PRE ENGINEERED BUILDINGS | f 06 PORTAL FRAME 2&.¢ PURUNS 8 GIRTS aman = R | ‘CABLE BRACING ROD BRACING ANGLE BRACING CAGE LADDER STANDARD FLASHINGS & TRIMS HMM COVER U TRIM. EAVE GUTTER \VALLEY GUTTER DOWN sPouT ACCESSORIES USED IN PRE ENGINEERED BUILDINGS PRIMARY PRODUCTION FLOW n = PEB Metal Quality Control & Safety i: im & Lia wins © Quality is the benchmark of our products designed and supplied by us | - Single point contact responsibility - Centralized Logistic Control - Centralized Site Management and Project Control - Highest Standards in Quality - zero Accident Philosophy - Trained Safety Teams - Trained On-Site Quality Management www.pebmetal.ir Got Sl lings PEB METAL BUILDINGS PRIVATE LIMITED PNM eR 100 Ale) MeO Aha Office Address : S. No.-5/6, Siddarth Nagar,FL-23, Building-B, PCCM crc ume orate TCA rte Co BU re Reco sauce Ere telorur Reon arsenal eLy Contact No. : +91-9922490404, 7774048220

You might also like