Table 1. QUANTITIES OF SEWAGE FLOW
‘Type of Establishment
Gals.Day/Person
‘Sal dwellings and cottages 50
Large dwellings with numerous foxtures 75-100
Multiple family residence 50
Rooming houses 40
Boarding houses 50
Hotels and motels 50
Restaurant (olet and kitchen wastes per person) 710
Restaurant (kitchen wastes per meal served) 12223
Kitchen wastes at hotels, camps, boarding houses, et, serving 3 meallday 7.10
Tourist camps or trailer parks 35.50
Resort camps (night and day) with limited plumbing 50
Luxury camps 75-100
Work or construction camps (semi-permanent) 50
Day schoo! without cafeterias, gymmasiums or showers” 5
Day school with cafeterias but no gyms or showers” (Quantity estimated from no.
of meas served or 80% of enrolment) 2
Day school with cafeterias, gyms and showers (Quantity estimated from maxionum
no, expected 1 use gyms and showers in one day) 20
Boarding schools 75-100
Day workers at schools and afices 15
Hospitals" (Gallons per bed) 150.250
Public instittions other than hospitals 75.128
Factories (Galperson/shif exclusive of industrial wastes) 15.35
Public picnie parks (toilet wastes only) 5
Picnic park, with bathhouse, showers and flush toilets 10
‘Swimming pools and bathing places 10
Luxury residences and estates 100-1 50
Country clubs per resident members” 25-50
"Subsurface drain fields not recommended for secondary treatment
24