[DRIVEWINDOW 2.

0 Report File]
12/03/2013 9:55

ROD PUMP CTRL {0}{1}

Parameters, 01: SENALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


01.01: VELOCIDAD [rpm] 650,22339
01.02: VELOC ESTIMADA [rpm] 652,37036
01.03: FRECUENCIA [Hz] 33,199432 -500 499,999939
01.04: CORRIENTE [A] 93,983093 -1289,761475 1289,76123
01.05: TORQUE [%] 75,36438 -1877,860107 1877,859863
01.06: TORQUE ESTIM [%] 80,12204
01.07: POTENCIA [%] 41,326523 -1000 999,9998779
01.08: TENSION BUS CC V [V] 639,84399 -4051,418945 4051,418457
01.09: TENSION DE RED [V] 452,21448 0 9999,998047
01.10: TENSION DE SALIDA [V] 265,73303 249,9997559 999,9990234
01.11: TEMP DEL ACS800 [C] 69,972046 -1000 999,9998779
01.12: HORAS OPER [h] 19538,18
01.13: TEMP AUTO-REAJST [min] 1 0 100000000
01.14: KILOWATIOS HORA [kWh] 231251,28 0 16609382
01.15: TEMP MOTOR 1 [C] 0 -5000 5000
01.16: TEMP MOT EST [C] 53,266289 -1000 999,9998779
01.17: TEMP1 BMB [C] 0 -10000 10000
01.18: TEMP2 BMB [C] 0 -10000 10000
01.19: ESTADO ED6 - 1 0X45
01.20: ESTADO SR3 - 1 0X3
01.21: EA1 (V) 0,00404001 0 10
01.22: EA2 (mA) 0 0 22
01.23: EA3 (mA) 0 0 22
01.24: SA1 (mA) 4,0534124 0 22
01.25: SA2 (mA) 19,99955 0 22
01.26: ESTADO XT ED6-1 0X0
01.27: ESTADO XT SR6-1 0X0
01.28: XT EA1 [%] 0 0 150
01.29: XT EA2 [%] 0 0 150
01.30: XT EA3 [%] 0 0 150
01.31: XT EA4 [%] 0 0 150
01.32: XT EA5 [%] 0 0 150
01.33: XT EA6 [%] 0 0 150
01.34: XT SA1 [mA] 0 0 22
01.35: XT SA2 [mA] 0 0 22
01.36: XT SA3 [mA] 0 0 22
01.37: XT SA4 [mA] 0 0 22
01.38: TEN MIN ARRANQUE [lb] 0 0 100000000
01.39: TEN MAX ARRANQUE [lb] 0 0 100000000
01.40: TEN MIN PARO [lb] 0 0 100000000
01.41: TEN MAX PARO [lb] 0 0 100000000
01.42: TEN MIN OPERAC [lb] 0 0 100000000
01.43: TEN MAX OPERAC [lb] 0 0 100000000
01.44: TEN MIN CICLO [lb] 0 0 100000000
01.45: TEN MAX CICLO [lb] 0 0 100000000
01.46: TIEMPO CICLO VACIO [min] 0 0 100000000
01.47: CONT CICLO BOMB 0X0
01.48: TMPO FALLA VACIO [min] 607 0 100000000
01.49: CONT FALLA BOMBA 0X0
01.50: LUGAR DE CONTROL EXT1

Parameters, 02: SENALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


02.01: REF VELOCIDAD 2 [rpm] 656,45081 525,3981934 1050,554199
02.02: REF VELOCIDAD 3 [rpm] 656,45081 525,3981934 1050,554199
02.03: REF VELOCIDAD 4 [rpm] 656,45081 525,3981934 1050,554199
02.04: REF TORQUE 1 [%] 0 -300 300
02.05: REF TORQUE 2 [%] 13,253983 -1877,860107 1877,859863
02.06: REF TORQUE 3 [%] 9,7884312 -1877,860107 1877,859863
02.07: REF TORQUE 4 [%] 10,851088 -1877,860107 1877,859863
02.08: REF TORQUE 5 [%] 13,900261 -1877,860107 1877,859863
02.09: REF TORQUE USUDA [%] 14,884119 -1408,39502 1408,39502
02.10: REF VELO USADA [rpm] 656,45081 525,3981934 1050,554199
02.11: CORRIENTE MTR IA [A] 96,991592 0 10000
02.12: CORRIENTE MTR IB [A] 95,586075 0 10000
02.13: CORRIENTE MTR IC [A] 99,510605 0 10000
02.14: CODIG DE EST 0X1F37
02.15: PUMP STATUS WRD1 0X8000
02.16: PUMP STATUS WRD2 0X4000
02.17: CODIGO FALLO 1 0X0
02.18: CODIGO FALLO 2 0X0
02.19: CODIGO ALARMA 1 0X0
02.20: CODIGO LIMITE 0X0

Parameters, 03: ACTUALES BALANCIN

NAME VALUE MINIMUM MAXIMUM


03.01: POTENCIA [Hp] 42,357193 0 10000
03.02: TORQUE BOMBA [lbft] 242,84082 -10000 10000
03.03: TENSION CABL [lb] 0 0 100000000
03.04: POSICION CALC [%] 100 -100 100
03.05: VELOC CALC BOMB [spm] 4,9925385 -10000 10000
03.06: CAMB VEL BOMB [rpm] 0 -10000 10000
03.07: TIEMPO OPER [min] 524 0 100000000
03.08: 24H TMP OPER [min] 1357 0 100000000
03.09: TMP REMA OPER [min] 15 0 100000000
03.10: TMP REMA LLENA [min] 30 0 100000000
03.11: POSICION STROKE [%] 100 0 100
03.12: STROCK BOMB UPSTROKE
03.13: CONT STROCK [stk] 0,5 0 100000000
03.14: APC SPD INC COUNT 0X0
03.15: PEAK TORQUE [%] 76,787903 0 500
03.16: ENERGY PER STRK [KWS] 2102,3486 0 100000000
03.17: CONT ALTO CARGA 0X0
03.18: CONT MIN CARGA 0X0
03.19: FLUJO PRODUCCION [Brl] 0,14042872 0 100000000
03.20: 24H PRODUCCION [Brl] 0,14042872 0 100000000
03.21: RATA PRODUCCION [Bpd] 2019,3035 0 10000
03.22: PRESION CASING [psi] 0 0 10000
03.23: PRESION TUBING [psi] 0 0 10000
03.24: PRESION INTAKE [psi] 0 0 10000
03.25: VELOC MED SPM [spm] 23,076923 -10000 10000

Parameters, 04: INFORMACION APLIC

NAME VALUE MINIMUM MAXIMUM


04.01: SW PACKAGE VER BRXR3300
04.07: APPL NAME BRAR3300
04.09: APPL RELEASE DATE APR 23, 2008
04.10: BOARD TYPE RMIO - 0X

Parameters, 06: ENTRADA FIELDBUS

NAME VALUE MINIMUM MAXIMUM


06.01: PALB COMAND 0X0
06.02: REF VELOC 1 0X0
06.03: REF VELOC 2 0X0
06.04: COMAND BOMBA 0X0
06.05: INPUT DATA WORD5 0X0
06.06: INPUT DATA WORD6 0X0
06.07: INPUT DATA WORD7 0X0
06.08: INPUT DATA WORD8 0X0
06.09: INPUT DATA WORD9 0X0

Parameters, 09: SEÐALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


09.01: EA1 ESCALADA 0X8
09.02: EA2 ESCALADA 0X0
09.03: EA3 ESCALADA 0X0
09.04: XT EA1 ESCALADA 0X0
09.05: XT EA2 ESCALADA 0X0
09.06: LCU ACT SIGNAL1 0XB8E
09.07: LCU ACT SIGNAL2 0X158
09.08: XT EA3 ESCALADA 0X0
09.09: XT EA4 ESCALADA 0X0
09.10: XT EA5 ESCALADA 0X0
09.11: XT EA6 ESCALADA 0X0

Parameters, 10: MARCHA/PARO/DIR

NAME VALUE MINIMUM MAXIMUM


10.01: EXT1 MAR/PARO ED1
10.02: EXT2 MAR/PARO ED1
10.03: DIRECCION AVANCE
10.04: PERMISO DE MARCHA YES

Parameters, 11: SELEC REFERENCIA

NAME VALUE MINIMUM MAXIMUM


11.01: SELEC EXT1/EXT2 SIN SEL
11.02: SELEC REF EXT1 PANEL PARA ARRANQUE PANEL-P
11.03: REF EXT1 MINIMO [spm] 3,9994993 0 18000
11.04: REF EXT1 MAXIMO [spm] 7,997159 0 18000
11.05: SELEC REF EXT2 PANEL
11.06: REF EXT2 MINIMO [spm] 3,9994993 0 18000
11.07: REF EXT2 MAXIMO [spm] 7,997159 0 18000

Parameters, 12: VELOC CONSTANTES

NAME VALUE MINIMUM MAXIMUM


12.01: SEL VELOC CONST SIN SEL
12.02: VELOC CONST 1 [rpm] 500 -500 500
12.03: VELOC CONST 2 [rpm] -500 -500 500

Parameters, 13: ENTRADAS ANALOG

NAME VALUE MINIMUM MAXIMUM


13.01: MINIMO EA1 0V
13.02: ESCALA EA1 100 50 500
13.03: FILTRO EA1 10 1 10000
13.04: MINIMO EA2 4 mA
13.05: ESCALA EA2 100 50 500
13.06: FILTRO EA2 100 1 10000
13.07: MINIMO EA3 4 mA
13.08: ESCALA EA3 100 50 500
13.09: FILTRO EA3 100 1 10000
13.10: MINIMO XT EA1 20%
13.11: ESCALA XT EA1 100 50 500
13.12: FILTRO XT EA1 100 1 10000
13.13: MINIMO XT EA2 20%
13.14: ESCALA XT EA2 100 50 500
13.15: FILTRO XT EA2 100 1 10000
13.16: MINIMO XT EA3 20%
13.17: ESCALA XT EA3 100 50 500
13.18: FILTRO XT EA3 100 1 10000
13.19: MINIMO XT EA4 20%
13.20: ESCALA XT EA4 100 50 500
13.21: FILTRO XT EA4 100 1 10000
13.22: MINIMO XT EA5 20%
13.23: ESCALA XT EA5 100 50 500
13.24: FILTRO XT EA5 100 1 10000
13.25: MINIMO XT EA6 20%
13.26: ESCALA XT EA6 100 50 500
13.27: FILTRO XT EA6 100 1 10000

Parameters, 14: SALIDAS DE RELE

NAME VALUE MINIMUM MAXIMUM


14.01: DO1 GROUP+INDEX 214 0 2000
14.02: DO1 BIT NUMBER 1 0 23
14.03: DO2 GROUP+INDEX 214 0 2000
14.04: DO2 BIT NUMBER 2 0 23
14.05: DO3 GROUP+INDEX 216 0 2000
14.06: DO3 BIT NUMBER 13 0 23
14.07: XTDO1 GROUP+INDEX 215 0 2000
14.08: XTDO1 BIT NUMBER 0 0 15
14.09: XTDO2 GROUP+INDEX 215 0 2000
14.10: XTDO2 BIT NUMBER 2 0 15

Parameters, 15: SALIDAS ANALOG

NAME VALUE MINIMUM MAXIMUM


15.01: SALIDA ANALOG 1 304 0 10000
15.02: INVERTIR EA1 NO
15.03: MINIMO SA1 4 mA
15.04: FILTRO SA1 10 0 10000
15.05: ESCALA SA1 30000 0 1000000
15.06: SALIDA ANALOG 2 311 0 10000
15.07: INVERTIR SA2 NO
15.08: MINIMO SA2 4 mA
15.09: FILTRO SA2 10 0 10000
15.10: ESCALA SA2 100 0 1000000
15.11: XT SALIDA ANALO1 303 0 10000
15.12: INVER XTSA1 NO
15.13: MINIM XTSA1 4 mA
15.14: FILTRO XTSA1 300 0 10000
15.15: ESCAL XTSA1 30000 0 1000000
15.16: XT SALIDA ANALO2 305 0 10000
15.17: INVER XTSA2 NO
15.18: MINIM XTSA2 4 mA
15.19: FILTRO XTSA2 500 0 10000
15.20: ESCAL XTSA2 18 0 1000000
15.21: XT SALIDA ANALO3 311 0 10000
15.22: INVER XTSA3 NO
15.23: MINIM XTSA3 4 mA
15.24: FILTRO XTSA3 300 0 10000
15.25: ESCAL XTSA3 100 0 1000000
15.26: XT SALIDA ANALO4 323 0 10000
15.27: INVER XTSA4 NO
15.28: MINIM XTSA4 4 mA
15.29: FILTRO XTSA4 300 0 10000
15.30: ESCAL XTSA4 500 0 1000000

Parameters, 16: ENTR CONTR SIST

NAME VALUE MINIMUM MAXIMUM


16.01: SEL RESTAUR FALLO MODULO COMUN
16.02: BLOQUEO PARAMETRO ABIERTO
16.03: CODIGO ACCESO 0 0 30000
16.04: BLOQUEO LOCAL NO
16.05: SALVAR PARAMETROS DONE

Parameters, 20: LIMITES

NAME VALUE MINIMUM MAXIMUM


20.01: VELOCIDAD MINIMA [rpm] 525,39819 -5999,999023 1050,554199
20.02: VELOCIDAD MAXIMA [rpm] 1050,5542 525,3981934 5999,999023
20.04: CORRIENTE MAXIMA [%Ihd] 180 0 204,9994812
20.05: RUN SPC TRQMAX [%] 300 0 300
20.06: SPC TORQMIN [%] -300 -600 0
20.07: FREQ TRIP MARGIN [Hz] 54 0 499,9949951
20.08: CTRL SOBRETENSION SI

Parameters, 21: MARCHA/PARO

NAME VALUE MINIMUM MAXIMUM


21.01: FUNCION MARCHA MAGN CC CNST
21.02: TIEMPO MAGN CONST [ms] 1000 30 10000
21.03: FUNCION PARO PARO LIBRE

Parameters, 22: ACEL/DECEL

NAME VALUE MINIMUM MAXIMUM


22.01: TIEMPO ACELER 1 [s] 5 0 1800
22.02: TIEMPO DECELER 1 [s] 0 0 1800
22.03: TIPO RAMPA ACE/DE [s] 0 0 1000

Parameters, 23: REF VELOCIDAD


NAME VALUE MINIMUM MAXIMUM
23.01: REF VELOCID [rpm] 656,45081 525,3981934 1050,554199
23.02: MULTIPLI VEL [%] 100 0 500
23.03: CORREC VEL [rpm] 0 -5999,999023 5999,999023
23.04: REF SPD ADD [rpm] 0 -5999,999023 5999,999023

Parameters, 24: CTRL VELOCIDAD

NAME VALUE MINIMUM MAXIMUM


24.01: MARCHA AUTOAJUSTE NO
24.02: DAMPENING COEF 2 0,016000748 8
24.03: GANANCIA 11,999966 0 250
24.09: TIEMP INTEGRACION [s] 0,29993057 0,01001358 999,9990234
24.10: INTEG INIT VALUE [%] 0 -300 300
24.11: DROOP RATE [%] 0 0 100
24.12: TIEMPO DERIVACION [ms] 0 0 9999,990234
24.13: DERIV FILT TIME [ms] 7,9870224 0 100000,0313
24.14: COMPENSACION ACE [s] 0 0 999,9998779
24.15: ACC COMP FILT [ms] 7,9870224 0 999999
24.16: GANANCIA DESLZMTO [%] 100 0 399,999939
24.21: TIEMP FILT VELACT [ms] 7,9870224 0 999999

Parameters, 27: CHOPPER

NAME VALUE MINIMUM MAXIMUM


27.01: CTRL CHOPPER OFF
27.02: FUNC SOBREC RESIS NO
27.03: VALOR RESIST [Ohm] 99,999908 0 99,99990845
27.04: CONST TERM RESIS [s] 0 0 9999,998047
27.05: POT FREN CONT MAX [HP] 0 0 9999,998047
27.06: MODO CTRL CHOPPER COMMON DC

Parameters, 30: FUNCIONES FALLOS

NAME VALUE MINIMUM MAXIMUM


30.01: MODO PROT TERM MO DTC/KLIXON DI6 DTC SIN TERMISTOR INS
30.02: PROT TERMICA MOT FALLO
30.03: M1 TEMP AI1 KEUZE SIN USAR
30.04: MOT1 TEMP ALM L [C] 90 -10 10000
30.05: MOT 1 TEMP FT L [C] 120 -10 10000
30.09: TIEMPO TERM MOTOR [s] 3359,9854 255,9995728 9999,900391
30.10: CURVA CARGA MOTOR [%] 100 50 150
30.11: CARGA VELOC CERO [%] 74 25 150
30.12: PUNTO RUPTURA [Hz] 53,999962 0,999987125 300
30.16: FUNC BAJA CARGA NO
30.17: TIEMPO BAJA CARGA [s] 20 0 600
30.18: CURVA BAJA CARGA 4
30.19: FALLO FASE MOTOR NO
30.20: FALLO A TIERRA FALLO
30.21: LVL FALLA TIERRA 3 0 8
30.22: EA<FUNCION MINIMA NO
30.23: FALLO PANEL ULTIMA VELOC
30.24: FALLO EXTERNO SIN SEL

Parameters, 34: AUT RESET FALLA

NAME VALUE MINIMUM MAXIMUM


34.01: SOBRETENSION OFF
34.02: SUBTENSION SI
34.03: OVRFREQ_SPD RESET OFF
34.04: CTRL HCASE PRES OFF
34.05: CTRL HTUBE PRES OFF
34.06: SENAL EA<MIN OFF
34.07: CTRL TEMP OFF
34.08: NUM REARRANQ 3 0 20
34.09: RETR TMP FUERA [min] 1 0 100000
34.10: TMP RETRAZO [min] 4 0 100000
34.11: PRESS SW RESET SI
34.12: LINE CONV RESET SI

Parameters, 52: MODBUS ESTANDAR

NAME VALUE MINIMUM MAXIMUM


52.01: NUM ESTACION 1 1 247
52.02: VEL TRANSM 9600
52.03: PARIDAD 1 STOP BIT

Parameters, 70: CONTROL DDCS

NAME VALUE MINIMUM MAXIMUM


70.01: DIREC CANAL 0 1 0 254
70.02: VEL TRANSM CH 0 1 Mbit/s
70.03: CH0 TIMEOUT [ms] 3000 0 60000
70.04: CH0 COM LOSS CTRL NO ERR CHK
70.12: DIREC CANAL 3 1 1 254

Parameters, 71: CONTROL BOMBA

NAME VALUE MINIMUM MAXIMUM


71.01: RANGO CELDCARGA [lb] 30000 0 1000000
71.02: MAX CARG CAB [lb] 15000 0 1000000
71.03: MIN CARG CAB [lb] 4000 0 1000000
71.04: VEL MAX BOMBA [spm] 8 0 100 PARA EL ARRANQUE INIC
71.05: VEL MIN BOMBA [spm] 4 0 100 PARA EL ARRANQUE INIC
71.06: VEL ARRANQUE [spm] 5 0 100 PARA EL ARRANQUE
71.07: TMP VEL ARR [s] 4 0 100 PARA EL ARRANQUE
71.08: DIAM POL MOTOR [inch] 11 0 1000000 PARA EL ARRANQUE I
71.09: DIAM POL UNID [inch] 52 0 1000000 PARA EL
71.10: RATA CAJAREDUC [ :1] 28 0 100 PARA EL ARRANQUE
71.11: EFICIENCIA BOMBA [%] 80 0 100
71.12: DIAMETRO BOMBA [inch] 5,4880457 0 1000000
71.13: LARGO STROKE [inch] 143,99991 0 1000000
71.14: CONT MAX CARGCAB 4 0 10
71.15: TMP MIN CARG CAB [s] 5 1 100
71.16: LIM MINCARG SPAN [lb] 4000 0 1000000
71.17: CNT MINCARG SPAN 3 0 12
71.18: FNC FALL CELCARGA NO FALLO
71.19: SL PERD CARG/INCL CTRL ON/OFF
71.20: SEL ENT INCLINO NO INCLINE
71.21: PUMPING UNIT TYPE MARK 2
71.22: SEL EA CELCARG SIN SEL
71.23: HABILITAR BOMBA NO HABILITAD PARA EL ARRANQUE
71.24: VALID RUN CNT LIM 5 0 100
71.25: TMP OPERAC BOMB [min] 15 1 1440
71.26: TMP LLENADO BMB [min] 30 1 1440
71.27: SEL REF CTRL SENO 0 10000
71.28: VAL NOM CTRL SENO 0 1000000
71.29: FLT REF CTRL SENO [ms] 0 1000000
71.31: START DELAY [s] 2 0 100 PARA EL ARRANQUE
71.32: START TORQ LIM [%] 300 0 300

Parameters, 72: ON/OFF & CTRL SENO

NAME VALUE MINIMUM MAXIMUM


72.01: POS VEL UPSTROKE [%] 75 0 99
72.02: POS VE1 DWNSTROKE [%] 70 0 99
72.03: AJT VEL DWNSTROKE [%] 2,9999757 -100 100
72.04: LIM MIN CARGA [lb] 1000 0 100000
72.05: HYST MIN CARGA [lb] 4000 0 100000
72.06: CONT MIN CARGA 3 1 100
72.07: VEL C MINCARGA [spm] 1,999999 0 100

Parameters, 74: SUPERVISION BOMB

NAME VALUE MINIMUM MAXIMUM


74.03: FUNC TEMP KLIXON NO
74.04: SEL TEMP KLOXON1 SIN SEL
74.05: CMB VEL TEMP MTR [spm] 1 0 20
74.06: SEL TIPO TEMP1 TEMP BEARING
74.07: FUNC TEMP1 BMB NO
74.08: SEL EA TEMP1 BMB EA5
74.09: ALM TEMP1 BMB [C] 170 0 500
74.10: LIM ALT TEMP1 BMB [C] 190 0 500
74.11: CMB VEL TEMP1 BMB [s] 1800 0 86400
74.12: MAX TEMP1 BMB [C] 302 0 500
74.13: SEL TIPO TEMP2 TEMP BEARING
74.14: FUNC TEMP2 BMB NO
74.15: SEL EA TEMP2 BMB EA6
74.16: ALM TEMP2 BMB [C] 170 0 500
74.17: LIM ALT TEMP2 BMB [C] 190 0 500
74.18: CMB VEL TEMP2 BMB [s] 1800 0 86400
74.19: MAX TEMP2 BMB [C] 302 0 500
74.20: CMB VEL TEMP BMB [spm] 1 0 20
74.21: FUNCION PRESION FAULT PARA EL ARRANQUE
74.22: SEL PRES CASING SIN SEL
74.23: MAX PRES CASING [psi] 50 0 1000
74.24: LIM PRES CASING [psi] 40 0 1000
74.25: SEL PRES TUBING SIN SEL
74.26: MAX PRES TUBING [psi] 500 0 1000
74.27: LIM ALT P TUBING [psi] 300 0 1000
74.28: LIM BAJ P TUBING [psi] 20 0 1000
74.29: TMP LIM PRESION [s] 1 1 1000 PARA EL ARRANQUE
74.30: SEL PRES INTAKE SIN SEL
74.31: MAX PRES INTAKE [psi] 500 0 5000
74.32: HIGH PRES SWITCH DI5 PARA EL ARRANQUE
74.33: PACKING SWITCH SIN SEL

Parameters, 75: VAL REAJUSTES

NAME VALUE MINIMUM MAXIMUM


75.01: REAJST 24Hor ACT NO REAJUSTAR
75.02: REAJST TEN ARRAQ NO REAJUSTAR
75.03: REAJST TEN PARO NO REAJUSTAR
75.04: RAJT CIC TMP/CNT NO REAJUSTAR
75.05: RAJUT TMP/CNT NO REAJUSTAR
75.06: RST TMP PRODCC SIN SEL

Parameters, 76: LIMIT TORQ

NAME VALUE MINIMUM MAXIMUM


76.01: FUNC TORQ MOTOR SIN SEL
76.02: LIM ALT TORQ MTR [lbft] 445,11554 0 10000
76.03: TMP ALT TORQ MTR [s] 30 0 86400
76.04: VEL ALT TRQ MTR [spm] 4 0 20
76.05: CONT ALTO TORQ 5 0 100
76.06: LIM BAJO TRQ MTR [lbft] 80,117432 0 10000
76.07: TMPO BAJ TRQ MTR [s] 60 0 86400

Parameters, 90: ENTRAD FIELDBUS

NAME VALUE MINIMUM MAXIMUM


90.01: INPUT DATA WORD5 0 0 10000
90.02: INPUT DATA WORD6 0 0 10000
90.03: INPUT DATA WORD7 0 0 10000
90.04: INPUT DATA WORD8 0 0 10000
90.05: INPUT DATA WORD9 0 0 10000

Parameters, 92: SALIDAS FIELDBUS

NAME VALUE MINIMUM MAXIMUM


92.01: OUTPUT DATA WORD1 214 0 10000
92.02: OUTPUT DATA WORD2 215 0 10000
92.03: OUTPUT DATA WORD3 216 0 10000
92.04: OUTPUT DATA WORD4 305 0 10000
92.05: OUTPUT DATA WORD5 303 0 10000
92.06: OUTPUT DATA WORD6 307 0 10000

Parameters, 95: HARDWARE SPECIF

NAME VALUE MINIMUM MAXIMUM


95.01: MODO CTRL VENT CONTROLADO
95.05: PERM INC FREQ CON NO
95.06: LCU Q PW REF 0 -10000 10000
95.07: LCU DC REF 0 0 1100
95.08: LCU PAR1 SEL 116 0 10000
95.09: LCU PAR2 SEL 117 0 10000
95.10: TEMP INV AMBIENT [C] 39,999962 0 49,99995422

Parameters, 98: MODULOS OPCIONAL

NAME VALUE MINIMUM MAXIMUM


98.02: MODULO COMUNIC MODBUS ESTAN
98.03: MOD EXT 1 E/S NO
98.04: MOD EXT 2 E/S NO
98.06: MODULO EXT1 E/S A NO
98.07: MODULO EXT2 E/S A NO
98.08: MODULO EXT3 E/S A NO
98.10: DI DEBOUNCE FILT 50 50 1000

Parameters, 99: DATOS DE PARTIDA

NAME VALUE MINIMUM MAXIMUM


99.01: IDIOMA ESPANOL
99.02: MACRO APLICACION DUAL SPD CTR
99.03: RESTAURAR APLIC SI PRIMER PASO ANTES DE P
99.04: MODO CTRL MOTOR DTC
99.05: TENSION NOM MOTOR [V] 459,9762 249,9997559 999,9990234 VOLTAGE DE PLACA
99.06: INTENS NOM MOTOR [A] 115,9799 0 341,9995117 CORRIENTE DE PLACA
99.07: FREC NOM MOTOR [Hz] 60 8,000015259 300 FRECUENCIA DE PLAC
99.08: VELOC NOM MOTOR [rpm] 1179,9336 1,001358032 17999,99609 VELOCIDAD RPM PLAC
99.09: POTENCIA NOM MOT [HP] 74,599976 0 9000 POTENCIA PLACA NOM
99.10: MARCHA IDENT MOT ID MAGN
99.11: TORQUE MOTOR CALC [lbft] 332,05182 0 10000
99.12: COMPL/CORTO MENU FULL MENU
ARA ARRANQUE PANEL-PARA SAM AI1
DTC SIN TERMISTOR INSTALADO/KLIXON DI6 SI EL TERMISTOR SE CONECTO
ARA EL ARRANQUE INICIAL OPCIONAL DEPENDE DEL MONTAGE
ARA EL ARRANQUE INICIAL OPCIONAL DEPENDE DEL MONTAGE
PARA EL ARRANQUE INICIAL
PARA EL ARRANQUE INICIAL
PARA EL ARRANQUE INICIAL MEDIR LA POLEA DEL MOTOR
PARA EL ARRANQUE INICIAL SEGÚN UNIDAD
PARA EL ARRANQUE INICIAL SEGÚN PLACA CAJA REDUCTORA UNIDAD

PARA EL ARRANQUE INICIAL

PARA EL ARRANQUE INICIAL


PARA EL ARRANQUE INICIAL

PARA EL ARRANQUE INICIAL

PARA EL ARRANQUE INICIAL


RIMER PASO ANTES DE PROGRAMAR

VOLTAGE DE PLACA MOTOR


CORRIENTE DE PLACAMOTOR
FRECUENCIA DE PLACA MOTOR
VELOCIDAD RPM PLACA MOTOR
POTENCIA PLACA NOMINAL MOTOR ( KW - HP )