You are on page 1of 20

1 2 3 4 5 6

21037
4537 4500 1463 4537 6000
10500 2050 3950
02
A 4
SECOND FLOOR LINE
SECOND FLOOR LINE
DN DN
D D

A
5
W
21 2
W
20
LINEN
CHUTE
W
17 TJ A. FLORES
LAV. SNK. ARCHITECTURAL DESIGN
2000

D + CONSULTANCY
3 DRY RNG.
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305

4500
WC
KITCHEN HOME THTR. RM. MOBILE No.: +(63) 917 594 4150

OVERHEAD CABINET
DINING PANTRY A=27.00 SQM. EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
6000

TABLE
D
4 AREA
A=27.00 SQM.
SNK. D
2 TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
REF.
NOOK PRINCIPAL ARCHITECT

SHELVES

11000
P.R.C. No.: 27108 VALIDITY: 03-10-2020
7000

W
DWWDWD

ALFRESCO 11
I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017

3237
B A=50.00 SQM. KOI POND LINE
13000

SECOND FLOOR LINE


PLAY RM. PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
R.A. 9266 SECTION 33

01 01 Drawings and specifications and other contract documents duly signed, stamped or

DN
sealed, as instruments of service are the intellectual property and documents of the
3000

architect, wether the object for which they are made is executed or not. It shall be
W 12 13 14 15 16 17 18 19 20

A 4 19 11 10 9 8 7 6 5 4 3 2 1
A 4 unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

UP
DESIGN CONSULTANT

UP
C CRAFTS' RM. .

3262
HIGH CEILING
SECOND FLOOR LINE

SECOND FLOOR LINE


KOI POND
2000

LIVING RM. /LIBRARY


W TABLE
5 D
4000

1 2 3 4
SHELVES
1
D 1 2 3 4 5 6 .
W W
2000

2000
KOI POND CONSULTANT
W 9 10 P.T.R. No.: VALIDITY:
SECOND FLOOR LINE 1A W W W P.T.R. No.: DATE:
2 2 2 PLACE: T.I.N. No.:
E ENGINEER
W SECOND FLOOR LINE 21037 .
1B
UP
2000 3750 1575 3712 1463 4537 6000 2000
02
9037 6000 4925 1675
A 4
02 ROOF LINE ABOVE
.

ROOF LINE ABOVE


A 4

2000

2000
5587 2500 950 12000 W W W W W W W .

1000
8B 8B 8B 8B 8B 15 15 P.T.R. No.: VALIDITY:
4538 4500 6000 6000 CANOPY LINE CANOPY LINE CANOPY LINE CANOPY LINE CANOPY LINE CANOPY LINE P.T.R. No.: DATE:
PLACE: T.I.N. No.:
21037 W W
W W W W BALCONY D LINEN W PROJECT NAME

SHOE
18

STO.
8A
SHELVES
8A 8A 8A 4
6.0M X 1.0M CHUTE 8A 13B
TABLE
A NICHE
W

SHELVES
SHO.

4000
LAV. 13A PROPOSED CONSTRUCTION OF

SHELVES

LINEN CAB. @ 600MM DEPTH


BDRM. 01 TWO STOREY RESIDENCE

3000
WC

TABLE

TABLE
5500

WC
A=24.17 SQM.

BUILT-IN CLOSET
BDRM. 03 BDRM. 02

LAV.
CANOPY LINE
W A=23.65 SQM. D A=22.25 SQM.
16 NICHE 3 FAMILY AREA SHO.

6000

SHO.
TABLE
BUILT-IN CLOSET NICHE PROJECT LOCATION

GROUND FLOOR PLAN


D NICHE
D 2 BUILT-IN CLOSET

01 FREE STANDING
LUCAS SUBDIVISION,

WC
3 TUB

ALTAR
BRGY. SAN FERMIN, CAUAYAN CITY,

LAV.
W ISABELA 3305
A 01 SCALE: 1:100 METERS

UNDER CAB.
D LAV. 12

@ 900MM HT.

575 3925
LOW CABINET
D

4500
1500 W SHOE CAB. @ 400MM DEPTH
D 3 OWNER
13200
WALK
2

ROOF LINE ABOVE


17 HALLWAY 2 IN

14000
1400MM WIDTH CLOSET

B SHO.
SPS. JUANITO A. AVANCENA

NICHE
SHELVES

WALK-IN CLOSET
01 01

DRESSER
D BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

DN
TABLE WC
2675

D 2
12 13 14 15 16 17 18 19 20 MINI PANTRY
A 4 2
11 10 9 8 7 6 5 4 3 2 1
A 4 SHEET CONTENTS
D
5000

UP
3 360° TURN
AS SHOWN
BDRM. 04 42" LED TV

C LAV.
A=24.83 SQM.
OPEN

4600
2325

TO
WC

MASTER BDRM.

5500
W D BELOW
14A W W A=51.55 SQM.
SHO.

7 6 6B
NICHE
D D
1200

W BALCONY W TABLE W 6 W REVISIONS:


2000

4.5M X 0.8M W 6A 7 6B
14B W
SHELVES
7 W W W
CANOPY LINE ABOVE 4A 3 3 3 BALCONYW W
E ROOF LINE ABOVE
6.5M X 1.0M 7 6A

1075
2000
CANOPY LINE ABOVE CANOPY LINE ABOVE

W
4B 02
A 4 ROOF LINE ABOVE

1675 3462 1963 2037 1463 4537 6000 2000


2000 4538 4500 6000 6625
22262 CHECKED BY: SHEET No.:

SECOND FLOOR PLAN AR. TJ A. FLORES

A-1
02 CADD BY:

A 1 SCALE: 1:100 METERS KDTALAUE


DATE: ARCHITECTURAL
07-20-17 PLANS
1 2 3 4 5 6

21037
4537 4500 1463 4537 6000
10500 2050 3950

SECOND FLOOR LINE


SECOND FLOOR LINE

A
TJ A. FLORES
ARCHITECTURAL DESIGN
2000

+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305

4500
MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
6000

TRISTAN JAMES A. FLORES, UAP, PGBI-ADP


PRINCIPAL ARCHITECT

11000
P.R.C. No.: 27108 VALIDITY: 03-10-2020
7000

DWWDWD

I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017

3237
B
13000

PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000


R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
3000

architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

C .

3262
SECOND FLOOR LINE

SECOND FLOOR LINE


2000
4000

D 1 2 3 4 5 6 .
2000

2000
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
E ENGINEER
SECOND FLOOR LINE 21037 .

2000 3750 1575 3712 1463 4537 6000 2000


9037 6000 4925 1675
ROOF LINE ABOVE
.

ROOF LINE ABOVE


2000

2000
5587 2500 950 12000 .

1000
P.T.R. No.: VALIDITY:
4538 4500 6000 6000 P.T.R. No.: DATE:
PLACE: T.I.N. No.:
21037 PROJECT NAME

4000
PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

3000
5500
GROUND FLOOR PLAN

6000
PROJECT LOCATION

01 REFLECTED CEILING PLAN LUCAS SUBDIVISION,


BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
A 2 SCALE: 1:100 METERS

575 3925
4500
1500 OWNER
13200

ROOF LINE ABOVE

14000
B SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
2675

SHEET CONTENTS
5000

AS SHOWN
C

4600
2325

5500
D
1200

REVISIONS:
2000

E ROOF LINE ABOVE

1075
2000
ROOF LINE ABOVE

1675 3462 1963 2037 1463 4537 6000 2000


2000 4537 4500 6000 6625
SECOND FLOOR PLAN 22262 CHECKED BY: SHEET No.:

REFLECTED CEILING PLAN AR. TJ A. FLORES

A-2
02 CADD BY:

A 2 SCALE: 1:100 METERS KDTALAUE


DATE: ARCHITECTURAL
07-20-17 PLANS
1 2 3 4 5 6 E D C B A

APEX LINE TJ A. FLORES


ARCHITECTURAL DESIGN

2000
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
TOP OF ROOF BEAM MOBILE No.: +(63) 917 594 4150
CEILING LINE EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

3200
2600
9400

DWWDWD

SECOND FLOOR FIN. LINE


CEILING LINE
R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
3600

sealed, as instruments of service are the intellectual property and documents of the
2900

architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT
GROUND FLOOR FIN. LINE .
NATURAL GROUND LINE
600

.
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
VIEW FROM NORTH VIEW FROM WEST PLACE: T.I.N. No.:
ENGINEER

01 FRONT ELEVATION 02 RIGHT SIDE ELEVATION .

A 3 SCALE: 1:100 METERS A 3 SCALE: 1:100 METERS


.
.
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:

A B C D E 6 5 4 3 2 1 PLACE:
PROJECT NAME
T.I.N. No.:

PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

PROJECT LOCATION

LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
APEX LINE
OWNER
2000

SPS. JUANITO A. AVANCENA


TOP OF ROOF BEAM BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
CEILING LINE
SHEET CONTENTS
3200
2600

AS SHOWN
9400

SECOND FLOOR FIN. LINE


CEILING LINE
3600

REVISIONS:

GROUND FLOOR FIN. LINE


NATURAL GROUND LINE
600

VIEW FROM EAST VIEW FROM SOUTH


03 LEFT SIDE ELEVATION 04 REAR ELEVATION CHECKED BY:

AR. TJ A. FLORES
SHEET No.:

A 3 SCALE: 1:100 METERS A 3 SCALE: 1:100 METERS


CADD BY:

KDTALAUE
DATE:

07-20-17
A-3
ARCHITECTURAL
PLANS
1 2 3 4 5 6 E D C B A

APEX LINE TJ A. FLORES


ARCHITECTURAL DESIGN

2000
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
TOP OF ROOF BEAM MOBILE No.: +(63) 917 594 4150
CEILING LINE EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

3200
2600

BEDROOM MASTER BEDROOM


TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
04 BEDROOM 01
9400

PRINCIPAL ARCHITECT
DWWDWD

SECOND FLOOR FIN. LINE P.R.C. No.: 27108 VALIDITY: 03-10-2020


I.A.P.O.A. No.:23215-200668-081717
CEILING LINE HIGH CEILING P.T.R. No.:7619391 DATE: 01-18-2017
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
HIGH CEILING LIVING RM. R.A. 9266 SECTION 33
CRAFT'S Drawings and specifications and other contract documents duly signed, stamped or
3600

LIVING RM. sealed, as instruments of service are the intellectual property and documents of the
2900

ROOM DINING architect, wether the object for which they are made is executed or not. It shall be

ALFRESCO unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
AREA without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT
GROUND FLOOR FIN. LINE .
NATURAL GROUND LINE
600

.
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
ENGINEER

01 LONGITUDINAL SECTION 02 CROSS SECTION .

A 4 SCALE: 1:100 METERS A 4 SCALE: 1:100 METERS


.
.
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
PROJECT NAME

PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

PROJECT LOCATION
2000 5200 3700
LUCAS SUBDIVISION,
1500 500 1300 1300 1300 1300 1233 1233 1233 800 BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
800 600

500
OWNER

SPS. JUANITO A. AVANCENA


BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
2600

2600

2600

2600
2100

2100

2100
SHEET CONTENTS

AS SHOWN

FINISH FLOOR LINE

D-1 D-2 D-3 D-4 D-5 D-6


REVISIONS:
SETS: 2 SETS: 1 SETS: 2
SETS: 1
SETS: 7 SETS: 6 LOCATION: DINING RM.,FAMILY RM. LOCATION: DINING RM.,FAMILY RM. LOCATION: DINING RM.,FAMILY RM.
LOCATION: LIVING RM.
LOCATION: BEDRMS,KITCHEN LOCATION: ALL BATHROOMS SPECS: 12mm THK. TEMP. GLASS ON SPECS: 12mm THK. TEMP. GLASS ON SPECS: 12mm THK. TEMP. GLASS ON
SPECS: 55mm THK. SOLID DOOR
SPECS: 55mm THK. SOLID DOOR SPECS: 55mm THK. SOLID DOOR IMP. ALUMINUM SECTION. POWDER IMP. ALUMINUM SECTION. POWDER IMP. ALUMINUM SECTION. POWDER
PANEL WITH HEAVY DUTY PIVOT
PANEL WITH HEAVY DUTY HINGES. PANEL WITH HEAVY DUTY HINGES. COATED (WOOD) WITH HEAVY DUTY COATED (WOOD) WITH HEAVY DUTY COATED (WOOD) WITH HEAVY DUTY
HINGES.
STAINLESS HINGES. STAINLESS PIVOT HINGES. STAINLESS HINGES.

03 DOORS SCHEDULE CHECKED BY:

AR. TJ A. FLORES
SHEET No.:

A 4 SCALE: 1:50 METERS CADD BY:

KDTALAUE
DATE:

07-20-17
A-4
ARCHITECTURAL
PLANS
1263 1263 4100
400 863 863 400 400 1263 1263
400 400 863 863 400
F F F F F

800

800
F F F F F

500

500
F F F F F

500 600 600

500 600 600


2500

2500
F F F F F

1200

1200
F F F F F F F

2600

2600

4500
F F F F F

900

900
F F F F F
FINISH FLOOR LINE
A B A B F F F F F W-5
TJ A. FLORES
ARCHITECTURAL DESIGN
400

378
W-1 W-2 W-3 W-4 + CONSULTANCY
SETS: 1 UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
SETS: 1 SETS: 3 SETS: 3 SETS: 1 LOCATION: STAIRCASE.
LOCATION: LIVING RM. LOCATION: LIVING RM. LOCATION: 2ND FLR. LIVING RM. LOCATION: 2ND FLR. LIVING RM.
F F F F F DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
SPECS: 12mm THK. TEMP. GLASS ON EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
SPECS: 12mm THK. TEMP. GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON STAINLESS STEEL SPIDER SYSTEM
POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED
ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION F F 1100
TRISTAN JAMES A. FLORES,

400
UAP, PGBI-ADP
2000 550 550
PRINCIPAL ARCHITECT
DWWDWD
1038 1038 1200 400 1200 400 P.R.C. No.: 27108 VALIDITY: 03-10-2020
519 519 519 519 400 925 925 I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017

600 600

600 600
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
F F

1200

1200
500

500 600 600 500

500 500 700 500


R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the

F F F
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.
2200

2200

2200
1200

2800
F F DESIGN CONSULTANT

1700

1700
500

FINISH FLOOR LINE .


CONSULTANT
A B A B
400

400

400
P.T.R. No.: VALIDITY:
W-6 W-7 W-8 W-9 W-10 W-11 P.T.R. No.: DATE:
PLACE: T.I.N. No.:
ENGINEER
SETS: 2 SETS: 4 SETS: 5 SETS: 1 SETS: 1 SETS: 1
LOCATION: MASTER BDRM, BEDRM 04 LOCATION: MASTER BDRM, BEDRM 04 LOCATION: BDRMS 1,2,3 LOCATION: LIVING RM. LOCATION: CRAFTS RM. LOCATION: PLAY RM. .

SPECS: 12mm THK. TEMP. GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON
POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED
ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION
.
.
1100 2400 1200 P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
600 600 600 600 600 600 600 PLACE: T.I.N. No.:
1475 2325
600 600

PROJECT NAME
400

400
738 738 425 625 625 1075 425
1200

500 500 700 500

500

500
PROPOSED CONSTRUCTION OF
F F F F TWO STOREY RESIDENCE
F

2200

2200

2200
1200

1200
1700

1700

1700

PROJECT LOCATION

500

500
LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
FINISH FLOOR LINE ISABELA 3305

A B A B

400

400

400
OWNER

W-12 W-13 W-14 W-15 W-16 W-17


SPS. JUANITO A. AVANCENA
SETS: 1 SETS: 1 SETS: 1 SETS: 2 SETS: 1 SETS: 1 BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
LOCATION: MASTER BDRM. T&B LOCATION: BDRM. 1 LOCATION: BDRM. 4 LOCATION: BDRM. 1 LOCATION: BDRM. 3 LOCATION: HALLWAY
SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. TEMP. GLASS ON SPECS: 6mm THK. TEMP. GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SPECS: 6mm THK. CLEAR GLASS ON SHEET CONTENTS
POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED POWDER COATED (WOOD) IMPORTED
ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION ALUM. SECTION AS SHOWN

3000
400

REVISIONS:
462 400
750 750 750 750
2325
600 600

600 1125 600


500

1200
500

F F
1700

WINDOWS SCHEDULE
1450

01
900

900

FINISH FLOOR LINE A 5 SCALE: 1:50 METERS


W-18 W-19 W-20 W-21
CHECKED BY: SHEET No.:
SETS: 2 SETS: 1 SETS: 1 SETS: 1 AR. TJ A. FLORES
LOCATION: BDRM 2,3 T&B
SPECS: 6mm THK. CLEAR GLASS ON
POWDER COATED (WOOD) IMPORTED
ALUM. SECTION
LOCATION: STAIRCASE
SPECS: 6mm THK. CLEAR GLASS ON
POWDER COATED (WOOD) IMPORTED
ALUM. SECTION
LOCATION: KITCHEN
SPECS: 12mm THK. CLEAR GLASS ON
POWDER COATED (WOOD) IMPORTED
ALUM. SECTION
LOCATION: POWDER RM.
SPECS: 6mm THK. CLEAR GLASS ON
POWDER COATED (WOOD) IMPORTED
ALUM. SECTION
NOTE:
VERIFY ACTUAL HEIGHT AND
DIMENSIONS FOR QUOTATIONS.
CADD BY:

KDTALAUE
DATE:

07-20-17
A-5
ARCHITECTURAL
PLANS
OFFICE OF THE
TABLE OF CONTENTS
BUILDING OFFICIAL
CS EXTERIOR PERSPECTIVE

N. 75° 28' W. 26.51 METERS VICINITY MAP


SITE DEVELOPMENT PLAN
1 2 3 4 5 6
A-01 GROUND FLOOR PLAN
SECOND FLOOR PLAN
A-02 GF REFLECTED CEILING PLAN
2F REFLECTED CEILING PLAN
CITY OF CAUAYAN
A
A-03 FRONT ELEVATION
PROVINCE OF ISABELA TJ A. FLORES
ARCHITECTURAL DESIGN
RIGHT SIDE ELEVATION
+ CONSULTANCY
LEFT SIDE ELEVATION UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
B
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
REAR ELEVATION EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
C

D
A-04 LONGITUDINAL SECTION LAND USE AND ZONING
E CROSS SECTION
TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
DOORS SCHEDULE PRINCIPAL ARCHITECT

D
P.R.C. No.: 27108 VALIDITY: 03-10-2020
A-05 WINDOWS SCHEDULE I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the

LINE AND GRADE architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.
N DESIGN CONSULTANT

S
. 100 METER

N. 12° 40' E. 98.06 METERS


A
.
ARCHITECTURAL CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:

01 EXTERIOR PERSPECTIVE ENGINEER

CS SCALE: NTS.

S. 17° 05' W
STRUCTURAL .

O
.
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
PROJECT NAME

PROPOSED CONSTRUCTION OF
SANITARY TWO STOREY RESIDENCE

PROJECT LOCATION

R
LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
OWNER
ELECTRICAL
SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

SHEET CONTENTS

AS SHOWN

MECHANICAL

M E.
S. 75° 28' W. 32.22 METERS

79 9'
REVISIONS:

2. ° 3
8
.5
N
ELECTRONICS

02 VICINITY MAP
CS SCALE: NTS.
03 SITE DEVELOPMENT PLAN GEODETIC CHECKED BY:

AR. TJ A. FLORES
SHEET No.:

CS SCALE: 1:300 METERS


CADD BY:

KDTALAUE
DATE:

07-20-17
CS
COVER SHEET
ELECTRICAL NOTES & SPECIFICATIONS
ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION
OF THE LATEST APPROVED EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE LAWS
AND ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES AND REQUIREMENTS
OF THE LOCAL DISTRIBUTION UTILITY AND TELEPHONE COMPANY.
1. SERVICE POWER SHALL BE 230V, SINGLE-PHASE, 2-WIRES + GROUND,
60HZ SYSTEM.
2. WIRING METHOD SHALL BE DONE IN PVC PIPE (PNS14) FOR LIGHTING, POWER, TELEPHONE
AND AUXILIARY SYSTEM THAT ARE EMBEDDED IN CONCRETE SLAB; IMC PIPE FOR FIRE ALARM
SYSTEM, EXPOSED CONDUIT LAYOUT AND MAJOR FEEDER RISER. TJ A. FLORES
ARCHITECTURAL DESIGN
3. SMALLEST BRANCH CIRCUIT WIRE SHALL BE2 3.5 mm THHN FOR LIGHTING AND POWER + CONSULTANCY
SYSTEM, UNLESS OTHERWISE STATED IN THE PLAN, IN RACEWAY 15mmØ TRADE SIZE UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
CONDUIT, WIRE SHALL BE INSULATED FOR 600 VOLTS. MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
4. ALL BRANCH CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED IN THE PLAN.
EXPOSED CIRCUIT RUN SHALL BE INSTALLED PARALLEL TO OR PERPENDICULAR WITH
THE BUILDING LINE AND SUPPORTED BY CONDUIT CLAMPS EVERY 1.5 METERS MAX. TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
DIAGONAL CONDUIT RUN SHALL NOT BE ACCEPTED. PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020
5. WHENEVER NECESSARY PULLBOX OF PROPER SIZE AND DIMENSION SHALL BE PROVIDED I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
ALTHOUGH NOT INDICATED IN THE PLAN. ALL JUNCTION BOXES SHALL BE PROVIDED PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000

WITH METAL PLATE COVER. R.A. 9266 SECTION 33


Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be

6. ALL FLUORESCENT LAMP SHALL BE PRE-HEAT TYPE, WITH HIGH POWER FACTOR unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,

BALLAST, CAPACITOR AND SPRING LOADED LAMP HOLDERS. without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

7. ALL LIGHT CONTROLLED SWITCHES SHALL BE RATED 16 AMPS, 250 VOLTS AC


ONLY, SWITCHES SHALL BE INSTALLED FOR WITH HORIZONTAL MOTION.
8. ALL PANELBOARD SHALL BE PROVIDED WITH MULTI-LINE TERMINAL GROUNDING BUS.
.
9. ALL METALLIC CONDUIT, CABINET, BOXES AND EQUIPMENT SHALL BE PROPERLY
GROUNDED AND BONDED. 01 VICINITY MAP P.T.R. No.:
P.T.R. No.:
PLACE:
CONSULTANT
VALIDITY:
DATE:
T.I.N. No.:
10. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR THE LOCATION E 01 SCALE: NTS ENGINEER
AND PURPOSES.
11. ALL BOXES SHALL BE MADE OF CODE GAUGE STEEL WITH ZINC CHROMATE PROTECTION.
12. ALL RECEPTACLE OUTLET SHALL BE PROPERLY GROUNDED TO THE BOX BY MEANS
OF GROUNDING LUGS. SERVICE ENTRANCE EDGAR M. LINTAO, pee

ISELCO I 50kVA,7.62/220V, 1Ph,60Hz PROFESSIONAL ELECTRICAL ENGINEER

13.ALL WIRES AND CABLES SHALL BE COLOR CODED AS FOLLOWS: OVERHEAD DISTRIBUTION TANSFORMER P.T.R. No.:003301
P.T.R. No.:92299055
VALIDITY: 03-11-2020
DATE: 01-03-2017
PLACE: CAUAYAN CITY T.I.N. No.: 438-865-565-000
LINE-A BLACK
LINE-2 RED G PROJECT NAME

PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE
GROUND GREEN
7.62 KV, 1Phase 50kVA,7.62/220V, 1Ph,60Hz
14. MOUNTING HEIGHT NOT SHOWN ON SCHEDULE ARE AS FOLLOWS: POWER SERVICE STAND-BY GENERATOR SET
a. LIGHT CONTROLLED SWITCHES 1.40m ABOVE FLOOR FINISH @ CENTER PROJECT LOCATION

b. DUPLEX CONVENIENCE OUTLET 0.30m ABOVE FLOOR FINISH @ CENTER 2-100mm2 THHN WIRE LUCAS SUBDIVISION,
+ 30mm2 THW GRND
c. TELEPHONE OUTLET
d. PANELBOARDS
0.30m ABOVE FLOOR FINISH @ CENTER
1.40m A.F.F.L., UNLESS NOTED OTHERWISE IN 65mm dia. PVC CONDUIT M BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
OWNER
e. CATV OUTLET 0.30m A.F.F.L., UNLESS NOTED OTHERWISE
MDP SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

LEGENDS: SHEET CONTENTS

WALL LIGHT PB POWER PANEL AS SHOWN

PIN LIGHTS PB-1 1 2 PB-2


DROP LIGHT M KILOWATT HOUR METER
PB-3 3 4 PB-4
REVISIONS / NOTES:
SPECIAL CEILING LIGHTING OUTLET 09 CIRCUIT HOMERUN
PB-5 5 6 PB-6
STRIP LIGHT (COVE LIGHT) SERVICE ENTRANCE PB-7 7 8 PB-8
FCO FLOOR CONVENIENCE OUTLET
CIRCUIT BREAKER REMARKS:

CONVENIENCE OUTLET 15 AT

ACU OUTLET

SINGLE LINE DIAGRAM


CEHECKED BY: SHEET No.:
WP WEATHERPROOF OUTLET
01 E.M.LINTAO

REF
RANGE OUTLET

REFRIGERATOR OUTLET
E 01 SCALE: NTS
CADD BY:

KDTALAUE
DATE:

07-20-17
E-1ELECTRICAL
PLANS/WORKS
1 2 3 4 5 6

21038
4538 4500 1463 4537 6000
10500 2050 3950

04 SECOND FLOOR LINE


TJ A. FLORES
PB-1 SECOND FLOOR LINE
ARCHITECTURAL DESIGN
06
PB-1
a' a' h' h' h' i' i' + CONSULTANCY
A e' f' c'
b' c' g'
Sh'i'

w w
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
2000

z MOBILE No.: +(63) 917 594 4150


y v
i' EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
r r r r a c
b b d
x
d' Sxyz

4500
q
Spq
Srs a c
p Stu
TRISTAN JAMES A. FLORES,
6000

b'
Svw v UAP, PGBI-ADP
Sa' u
p Sb'c'd' PRINCIPAL ARCHITECT
Se'f'g'
d' u 01 a c d
P.R.C. No.: 27108 VALIDITY: 03-10-2020
DWWDWD

PB-2
p
Sab
u' I.A.P.O.A. No.:23215-200668-081717
u
Scd P.T.R. No.:7619391 DATE: 01-18-2017
05
b' PB-1
Sq'r'
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
t t t t Sj'k'l'

11000
Ss't'u' R.A. 9266 SECTION 33
7000

s s s s s' s' Drawings and specifications and other contract documents duly signed, stamped or
r'
sealed, as instruments of service are the intellectual property and documents of the

3237
architect, wether the object for which they are made is executed or not. It shall be

B
13000

unlawful for any person to duplicate or make copies of said documents for use in the
e' f' g' 03 j'
repetition of and for other projects or buildings, wether executed partly or whole,
PB-1 t'
b' without the written consent of the architect or author of the said documents.
m q'
n n n m DESIGN CONSULTANT
u'
3000

t'
j'

d'
o
n n
j'
p'

3262
Smno
SECOND FLOOR LINE

b' m'

SECOND FLOOR LINE


g'
p'
2000

k l k to fixture jkl
@ second flr j'
.
to fixture abc n'

1 2 3 4 5 6
d' CONSULTANT
Sjkl @ second flr
Sm'n' P.T.R. No.:
4000

to fixture def So'p' o' o' VALIDITY:


k l k @ second flr
D e' f'
b'
to fixture ghi
@ second flr l' l'
P.T.R. No.:
PLACE:
DATE:
T.I.N. No.:
2000

2000
c' ENGINEER
k l k

k' k' k'

E 02
PB-1 j j j
SECOND FLOOR LINE 21038
2000 3750 1575 3712 1463 4537 6000 EDGAR M. LINTAO, pee
9038 6000 4925 1675 PROFESSIONAL ELECTRICAL ENGINEER
P.T.R. No.:003301 VALIDITY: 03-11-2020
ROOF LINE ABOVE
P.T.R. No.:92299055 DATE: 01-03-2017

ROOF LINE ABOVE


PLACE: CAUAYAN CITY T.I.N. No.: 438-865-565-000
5588 2500 950 12000

2000
PROJECT NAME

1000
4538 4500 6000 6000 PROPOSED CONSTRUCTION OF
g 01 e
21037 PB-5 S3Wabc
l TWO STOREY RESIDENCE
Sd Sd'
d Sd S3Wabc d' d d' j
a b b b a
Sd'
01
A c
PB-4
c

b
c

b
c
Sab i

GROUND FLOOR PLAN


h

4000
d g
i k
Sd h c c c 01 l
Sfe

3000
Sfg PB-7 a Sghi
PROJECT LOCATION

5500
LIGHTING LAYOUT
Shi
f

02 Se

e
g
a
d d
c b c
f
LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,

6000
S3Wabc a e
k ISABELA 3305
E 1 SCALE: 1:100 METERS Sf Shi
j
S3Wabc
Se e e e
S3Wabc
Sjkl
i
OWNER
Sjk i 01 r
f h f PB-8
Scd

575 3925
S3Wabc Sef
h SPS. JUANITO A. AVANCENA

4500
Sg

1500
Sghi g

13200
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

ROOF LINE ABOVE


S3Wjkl Sghi
i h g h g h

14000
c Sdef
d

B S3Wabc
01
PB-3 g
e f
SHEET CONTENTS
Sbc
r
2675 j to Sabc
@ grnd flr b a b AS SHOWN
a c
Sa n
l e
Se
S3Wjkl
c' l Sn
5000

S3Wabc
Sc' m
Sfg k j
Shi c c S3Wjkl
b a l Sm
C g b c
j

4600
k
2325

f
c 01 c

5500
Sd PB-1 h Sm' REVISIONS / NOTES:
h d b q
b m'
i Sjkl

D 01
1200

PB-6 f j j
l
j
Sop
to Sghi h Sqr o
k k @ grnd flr d d e e e e d d
q
g to Sdef p
@ grnd flr

E ROOF LINE ABOVE


i i i
o o o

REMARKS:

1075
2000
g

SECOND FLOOR PLAN


ROOF LINE ABOVE

02 LIGHTING LAYOUT 1675 3462 1963 2037 1463 4537 6000 2000 CEHECKED BY:

E.M.LINTAO
SHEET No.:

E-2
2000 4538 4500 6000 6625
CADD BY:
E 2 SCALE: 1:100 METERS 22262

KDTALAUE
DATE: ELECTRICAL
07-20-17 PLANS/WORKS
1 2 3 4 5 6

TJ A. FLORES
ARCHITECTURAL DESIGN
SECOND FLOOR LINE
SECOND FLOOR LINE
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
08 DISTRICT 1, CAUAYAN CITY, ISABELA 3305
WP PB-1 03 MOBILE No.: +(63) 917 594 4150
WP
A WP
PB-2 EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

07 WP
PB-1 A-WP
ACU
PB-1 11 2HP
13
PB-1
PB-1
RNG. TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
MDP
02 PRINCIPAL ARCHITECT
PB-2
DWWDWD
MW P.R.C. No.: 27108 VALIDITY: 03-10-2020
ACU I.A.P.O.A. No.:23215-200668-081717
3HP FCO P.T.R. No.:7619391 DATE: 01-18-2017
FCO
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
REF. R.A. 9266 SECTION 33
PB-2 Drawings and specifications and other contract documents duly signed, stamped or
12
PB-1 sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
15 without the written consent of the architect or author of the said documents.
PB-1
B WP
KOI POND LINE

SECOND FLOOR LINE


ACU
1.5HP
DESIGN CONSULTANT

WP

DN
12 13 14 15 16 17 18 19 20

11 10 9 8 7 6 5 4 3 2 1

UP

UP
.
C 09
SECOND FLOOR LINE

CONSULTANT

SECOND FLOOR LINE


KOI POND PB-1 ACU 16
1.5HP PB-1 P.T.R. No.: VALIDITY:
10
PB-1 1 2 3 4 5 6 P.T.R. No.:
PLACE:
DATE:
T.I.N. No.:
ENGINEER
D
KOI POND
ACU
14 3HP
PB-1
SECOND FLOOR LINE

E EDGAR M. LINTAO, pee


SECOND FLOOR LINE
PROFESSIONAL ELECTRICAL ENGINEER
UP
P.T.R. No.:003301 VALIDITY: 03-11-2020
P.T.R. No.:92299055 DATE: 01-03-2017
ROOF LINE ABOVE
PLACE: CAUAYAN CITY T.I.N. No.: 438-865-565-000
PROJECT NAME

ROOF LINE ABOVE


PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

02 WP
PB-5

GROUND FLOOR PLAN A 03


PB-5
02
PB-3

ACU 04 PROJECT LOCATION

POWER LINE LAYOUT ACU PB-7 WH A-WP


1.5HP
2HP 02
01 A-WP
03
PB-7 LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
PB-3 03 ACU ISABELA 3305
E 03 SCALE: 1:100 METERS WH
04
PB-5
PB-7
1.5HP
OWNER
ACU
1.5HP 04 PB-5
PB-4 PB-3 PB-7
A-WP
SPS. JUANITO A. AVANCENA
PB-4 WH 06
PB-8 WH BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
02 03

ROOF LINE ABOVE


PB-4 PB-4
A-WP SHEET CONTENTS

B PB-6 04 AS SHOWN
PB-8 PB-8

DN
12 13 14 15 16 17 18 19 20

11 10 9 8 7 6 5 4 3 2 1
05 REF.
PB-8
04

UP
PB-6
ACU
2HP
C WH
A-WP
REVISIONS / NOTES:
ACU 03
02 PB-8
1.5HP PB-8
03
PB-6
02
D WP
PB-6

WP
E ROOF LINE ABOVE
REMARKS:

SECOND FLOOR PLAN ROOF LINE ABOVE

02 POWER LINE LAYOUT CEHECKED BY:

E.M.LINTAO
SHEET No.:

E 03 SCALE: 1:100 METERS


CADD BY:

KDTALAUE
DATE:

07-20-17
E-3ELECTRICAL
PLANS/WORKS
TJ A. FLORES
ARCHITECTURAL DESIGN
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

TRISTAN JAMES A. FLORES, UAP, PGBI-ADP


PRINCIPAL ARCHITECT
DWWDWD
P.R.C. No.: 27108 VALIDITY: 03-10-2020
I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

.
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
ENGINEER

EDGAR M. LINTAO, pee


PROFESSIONAL ELECTRICAL ENGINEER
P.T.R. No.:003301 VALIDITY: 03-11-2020
P.T.R. No.:92299055 DATE: 01-03-2017
PLACE: CAUAYAN CITY T.I.N. No.: 438-865-565-000
PROJECT NAME

PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

PROJECT LOCATION

LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
OWNER

SPS. JUANITO A. AVANCENA


BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

SHEET CONTENTS

AS SHOWN

REVISIONS / NOTES:

REMARKS:

CEHECKED BY: SHEET No.:

E.M.LINTAO
CADD BY:

KDTALAUE
DATE:

07-20-17
E-4ELECTRICAL
PLANS/WORKS
GENERAL PLUMBING NOTES
3300 3300
1. ALL PLUMBING WORKS HEREIN SHALL BE EXECUTED
ACCORDING TO THE REQUIREMENTS OF THE PHILIPPINE NATIONAL 100 1000 2000 100 1000 2000 100
PLUMBING CODE AND THE RULES AND REGULATIONS OF THE EXISTING - SEWER LINE
600 100 600 100 600 100 600
LOCAL CODES AND ORDINANCES. NOTHING CONTAINED IN THE DRAWING - STORM DRAINAGE LINE

100
SHALL BE CONSTRUCTED TO CONFLICT WITH THE NATIONAL AND LOCAL
ORDINANCE OR LAW GOVERNING THE IMPLEMENTATION OF THE PLUMBING - VENT
WORKS.
- COLD WATER LINE
2. REFER TO ALL ELECTRICAL, MECHANICAL, STRUCTURAL AND

100
LAV - LAVATORY
ARCHITECTURAL PLANS AND SPECIFICATIONS AND INVESTIGATE ALL

1000
500
POSSIBLE INTERFERENCES AND CONDITIONS AFFECTING PLUMBING WORKS. WC - WATER CLOSET

3. IT IS NOT INTENDED THAT DRAWINGS SHALL SHOW EVERY PIPE SH - SHOWER/SHOWER HEAD

1800
FITTING, VALVE AND OTHER APPURTENANCES. FURNISH AND INSTALL IF S - SINK

2000
NECESSARY ALL ITEMS WHETHER SPECIFICALLY MENTIONED OR NOT OR
INDICATED IN THE DRAWINGS, TO COMPLETE THE SYSTEM IN F - FAUCET
ACCORDANCE WITH THE BEST PRACTICE OF THE PLUMBING TRADE AND
TJ A. FLORES

100
TO THE ENTIRE SATISFACTION OF THE SANITARY ENGINEER IN CHARGE. FD - FLOOR DRAIN

200
ARCHITECTURAL DESIGN

1000
500
FCo - FLOOR CLEANOUT
4. PERFORM ALL LABOR IN A FIRST CLASS AND NEAT WORKMANSHIP BY

300
SPECIALISTS SKILLED IN THEIR TRADES, SUCH SPECIALISTS AND THEIR CB - CATCH BASIN + CONSULTANCY
WORKS SHALL BE TO THE ENTIRE SATISFACTION OF THE SANITARY UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
ENGINEER IN-CHARGE. SV - SEPTIC VAULT DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
GV - GATE VALVE
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
BASIC MATERIALS

100
CV - CHECK VALVE
1. PROVIDE MATERIALS THAT ARE NEW AND IN CONFORMITY WITH THE VS - VENT STACK
MATERIAL SPECIFICATIONS AS REQUIRED BY THE ARCHITECT/ SANITARY GCo - GROUND CLEAN OUT TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
ENGINEER IN CHARGE.
VAC - VENT ABOVE CEILING PRINCIPAL ARCHITECT
2. FOR OTHER REQUIRED MISCELLANEOUS MATERIALS NOT SPECIFICALLY P.R.C. No.: 27108 VALIDITY: 03-10-2020
V - VENT LINE
MENTIONED, PROVIDE THE BEST OF ITS KIND.

3. SUBMIT SAMPLES OF MATERIALS FOR APPROVAL AS REQUIRED BY


THE ARCHITECT/ SANITARY ENGINEER IN-CHARGE.
DS - DOWNSPOUT 01 SEPTIC TANK DETAIL I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391
PLACE: CAUAYAN CITY
DATE: 01-18-2017
T.I.N. No.: 276-677-312-000
R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or

4. CONFORM ALL APPLICABLE PIPES AND MATERIALS FOR VARIOUS GI - GALVANIZED IRON
P 01 SCALE: NTS sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
SERVICES TO THE STANDARDS OUTLINE BELOW. P - PLUG/CAP without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT
PLUMBING FIXTURE MM - MILLIMETERS
.
SR/SS - SEWER RISER/ SOIL STACK
1. INSTALL ALL PLUMBING FIXTURES FREE AND OPEN IN A MANNER TO SP - SOIL PIPE
690 690
ACCESS FOR CLEANING, FURNISH WITH BRACKETS, CLEATS , PLATES AND WP - WASTE PIPE
ANCHORS REQUIRED TO SUPPORT THE FIXTURE RIGIDLY IN PLACE.
BFL - BELOW FLOOR LEVEL
2. VEER AWAY AT A SUFFICIENT DISTANCE, BUT NOT LESS THAN 1/2 UF - UPFEED .
INCH (12.7mm), ALL SERVICE PIPES, VALVES AND FITTINGS FROM MH - MAN HOLE CONSULTANT
SURFACES AND LOCATIONS WHICH MAY REQUIRE FINISH COAT OR
C.I. - CAST IRON VALIDITY:
COVERING. P.T.R. No.: DATE:

690

690
PPR (Pn10) - POLYPROPYLENE RANDOM Type 3 (Fusion Weld) PLACE: T.I.N. No.:
3. EXTEND THE PIPING TO ALL FIXTURE, OUTLETS AND EQUIPMENT FROM REGISTERED MASTER PLUMBER
REQUIRED GATE VALVES INSTALLED IN EACH BRANCH NEAR RISERS. CCo - CEILING CLEAN OUT
.
AAV - AIR ADMITTANCE VALVE
SHUT-OFFS
1. PROVIDE ENTIRE SYSTEM WITH VALVES SO LOCATED THAT THE SYSTEM
OR PORTIONS OF IT CAN BE OPERATED, REPAIRED AND REPLACED AS
WELL AS AFFORDING COMPLETE CONTROL OF THE WATER SUPPLY TO FIN. LINE GRADE
EACH GROUP OF FIXTURES, WHEN REQUIRED, PROVIDE ALSO PRESSURE ROLANDO H. SIBAYAN, RMP
PVC CLEANOUT PLUG
REDUCING VALVES. POURED CONCRETE PAD REGISTERED MASTER
. PLUMBER

SOIL, WASTE, DRAIN AND VENT


PIPES
PVC CLEANOUT PLUG

PVC 1/8 BEND


FIN. WALL LINE
PVC 1/8 BEND

PVC WYE FITTING


02 CATCH BASIN DETAILS P.R.C. No.: 0007780
P.T.R. No.: 8258581
PLACE: ROXAS, ISABELA
VALIDITY: 07-08-2018
DATE: 03-20-2017

PROJECT NAME

1. INSTALL ALL PLUMBING WORKS IN CONFORMITY WITH ALL PROVISIONS P 01 SCALE: NTS
OF THE LATEST EDITION OF THE PHILIPPINE PLUMBING CODE AND
APPLICABLE REQUIREMENTS O EXISTING LOCAL CODES. PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE
2. EXCAVATE TO REQUIRED DEPTHS AND GRADES ALL EXCAVATIONS
REQUIRED FOR THE INSTALLATION OF PLUMBING ND DRAINAGE SYSTEM.
WHEN ROCK IS ENCOUNTERED, EXTEND EXCAVATION TO A DEPTH OF
150mm BELOW THE PIPE BOTTOM. PROJECT LOCATION

3. LAY WATER SUPPLY PIPES AND SEWER IN SEPARATE TRENCHES. AT GRADE LUCAS SUBDIVISION,
AT WALL BRGY. SAN FERMIN, CAUAYAN CITY,
JOINTS AND FITTINGS ISABELA 3305

1. MAKE ALL JOINTS WATER TIGHT. FOR JOINING PIPES, USE THE
FOLLOWING: 03 DETAILS OF CLEANOUT SPS. JUANITO A. AVANCENA
OWNER

a. CAST IRON PIPES: BELL AND SPIGOT JOINTS CAULKED WITH AUKUM
AND SOFT PIG LEAD P 01 SCALE: NTS BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
b. GALVANIZED IRON AND COPPER PIPES: CAREFULLY REAMED THREADED
JOINTS. APPLY TEFLON TAPE OR PAINT WITH RED LEAD AT ALL JOINT SHEET CONTENTS
LENGTHS.
c. CEMENT PIPES: GROUT WITH CEMENT, MIX ALL AROUND THE JOINTS IN AS SHOWN
A CONSISTENT MANNER. DO NOT ALLOW GROUT TO BULGE INSIDE PIPE
INTERIORS.
d. uPVP PIPES: USE APPROPRIATE COUPLING AND GLUE AT JOINTS CAPPED

VENT CAP
0.30

CLEANOUTS CHB WALL


1. FOR CLEANOUTS STEMMING FROM CAST IRON BELL AND SPIGOT PIPES
OR uPVC SUBSTITUTES THEREOF, PROVIDE WITH LONG SWEEP QUARTER HOSE BIBB
BEND OR ONE OR TWO EIGHT BENDS EXTENDED TO AN EASILY
DETAILS(STUDOR) REVISIONS:
VARIES

ACCESSIBLE PLACE AND GENERALLY WHERE INDICATED IN THE DRAWINGS.


20 MM. DIA. CWL 04
TRAPS
1. EXCEPT FOR THE PRESENCE OF GREASE INTERCEPTOR AND OTHER
DEVICES WHERE TRAPS IS AN INTEGRAL PART OF THE DESIGN, EQUIP
20 MM. DIA. GATE VALVE
P 01 SCALE: NTS
WITH A TRAP EVERY FIXTURE AND EQUIPMENT REQUIRING CONNECTION
0.30

TO THE DRAINAGE SYSTEM.

2. SET EACH TRAP AS CLOSE AS POSSIBLE TO THE FIXTURE SERVED


AND RENDER LEVEL WITH RESPECT TO THEIR WATER SEAL.

OTHERS
1. PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION REQUIRED
FOR PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR
APPROVAL OF THE SANITARY ENGINEER IN-CHARGE.
2. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL
05 HOSE BIB DETAIL 06 AIR CAP CHAMBER DETAIL CHECKED BY: SHEET No.:
R.SIBAYAN, rmp

P-1
LOCATION, DEPTH AND INVERT ELEVATIONS. P 01 SCALE: NTS P 01 SCALE: NTS CADD BY:
3. ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE INDICATED.

4. AIR CHAMBER: ALL INDIVIDUAL BRANCHES TO THE FIXTURE OR GROUP


OF FIXTURES AND/ OR EQUIPMENT SHALL BE PROVIDED WITH AIR KDTALAUE
CHAMBER WITH CAPPED VERTICAL PIPE EXTENSION OR DIMENSIONS. DATE: SANITARY &
07-20-17 PLUMBING PLANS
1 2 3 4 5 6

21037
4537 4500 1463 4537 6000 ..\..\..\Desktop\TAF Documents\TAF Logo.jpg

10500 2050 3950


1.5HP BOOSTER
PUMP 800 GALS. CAPACITY
WATER TANK
PIPE SIZE SCHEDULE
120 GALS. CAPACITY CV SECOND FLOOR LINE
PRESSURE TANK CWL - COLD WATER LINE
SECOND FLOOR LINE
DN DN TAP TO MAIN
M MAIN PIPES: USE 32mm DIA. PPR PIPE PN20
TJ A. FLORES
CWL CWL WATER
CV GV
CWR GV SUPPLY BRANCH PIPES: USE 25mm DIA. PPR PIPE PN20
A

CWL
GV
ARCHITECTURAL DESIGN

CWL
SNK.
HWL - HOT WATER LINE
2000

HOT LINE PIPES: USE 25mm DIA. PPR PIPE PN20 + CONSULTANCY
HB

CWL
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
3WV
DISTRICT 1, CAUAYAN CITY, ISABELA 3305

4500
CWR - COLD WATER LINE RISER MOBILE No.: +(63) 917 594 4150

CWL
MAIN PIPES: USE 32mm DIA. PPR PIPE PN20 EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
6000

SNK.

TRISTAN JAMES A. FLORES, UAP, PGBI-ADP


PRINCIPAL ARCHITECT

11000
P.R.C. No.: 27108 VALIDITY: 03-10-2020
7000

DWWDWD

CWL I.A.P.O.A. No.:23215-200668-081717


HB GV
P.T.R. No.:7619391 DATE: 01-18-2017

3237
GV
B KOI POND LINE
13000

PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000


HB SECOND FLOOR LINE R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or

DN
sealed, as instruments of service are the intellectual property and documents of the
3000

architect, wether the object for which they are made is executed or not. It shall be
12 13 14 15 16 17 18 19 20
unlawful for any person to duplicate or make copies of said documents for use in the
11 10 9 8 7 6 5 4 3 2 1 repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

UP
DESIGN CONSULTANT

UP
C .

3262
SECOND FLOOR LINE

SECOND FLOOR LINE


CWL

KOI POND
2000
4000

D 1 2 3 4 5 6 .
2000

2000
KOI POND CONSULTANT
VALIDITY:
SECOND FLOOR LINE P.T.R. No.: DATE:
PLACE: T.I.N. No.:
E GV REGISTERED MASTER PLUMBER
SECOND FLOOR LINE 21037 .
CWL

UP
2000 3750 1575 3712 1463 4537 6000 2000
HB
9037 6000 4925 1675
ROOF LINE ABOVE
ROLANDO H. SIBAYAN,

ROOF LINE ABOVE


RMP

2000

2000
5587 2500 950 12000 REGISTERED MASTER PLUMBER

1000
P.R.C. No.: 0007780 VALIDITY: 07-08-2018
4538 4500 6000 6000 P.T.R. No.: 8258581 DATE: 03-20-2017
PLACE: ROXAS, ISABELA
21037 CWR PROJECT NAME

CWL MAIN CWL MAIN CWL MAIN


A HWL
GV
MP

4000
PROPOSED CONSTRUCTION OF

CWL
3WV
TWO STOREY RESIDENCE

3000
HWL

HWL
CWL
5500

CWL
CWL MAIN
3WV

GROUND FLOOR PLAN MP

6000
GV PROJECT LOCATION

H&C WATER LINE LAYOUT 3WV

HWL

CWL
01 LUCAS SUBDIVISION,

CWL
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305

HWL
GV
P 2 SCALE: 1:100 METERS GV

575 3925
MP

4500
1500 OWNER
13200

CWL
CWL MP

ROOF LINE ABOVE

14000
B

HWL
SPS. JUANITO A. AVANCENA

CWL
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

DN
2675

3WV
12 13 14 15 16 17 18 19 20
CWL
SHEET CONTENTS
11 10 9 8 7 6 5 4 3 2 1
5000

UP
MP AS SHOWN
GV
C
CWL

4600
2325

HWL

5500
3WV

D
1200

REVISIONS:
2000

1075
2000
ROOF LINE ABOVE

1675 3462 1963 2037 1463 4537 6000 2000


2000 4538 4500 6000 6625
SECOND FLOOR PLAN 22262 CHECKED BY: SHEET No.:

H&C WATER LINE LAYOUT R.SIBAYAN, rmp

P-2
02 CADD BY:

P 2 SCALE: 1:100 METERS KDTALAUE


DATE: SANITARY &
07-20-17 PLUMBING PLANS
1 2 3 4 5 6

21037
4537 4500 1463 4537 6000 ..\..\..\Desktop\TAF Documents\TAF Logo.jpg

10500 2050 3950 CONNECT TO EXISTING


SEWER SYSTEM
SEPTIC
TANK
(SEE DETAILS)
PIPE SIZE SCHEDULE
SECOND FLOOR LINE SP - SOIL PIPE
SECOND FLOOR LINE
DIA. MAIN BRANCH: USE 150mm SERIES 1000 uPVC PIPE
SS
SP MAIN
VC
VS SP MAIN
VC
SP MAIN
WATER CLOSET: USE 100mm DIA. SERIES 1000 uPVC PIPE
DIA. LAV. DRAIN: USE 50mm SERIES 1000 uPVC PIPE
TJ A. FLORES
A FLOOR DRAIN: USE 50mm SERIES 1000 uPVC PIPE
ARCHITECTURAL DESIGN
FCO

VAC
+ CONSULTANCY

SP
2000

VS UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,


VAC - VENT ABOVE CEILING

VAC
SP
DISTRICT 1, CAUAYAN CITY, ISABELA 3305

DP
USE 50mm SERIES 1000 uPVC PIPE MOBILE No.: +(63) 917 594 4150

4500
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
6000

VS SS - SOIL STACK
FCO USE 150mm SERIES 1000 uPVC PIPE
FCO TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
PRINCIPAL ARCHITECT
SP

P.R.C. No.: 27108 VALIDITY: 03-10-2020

11000
DWWDWD
7000

I.A.P.O.A. No.:23215-200668-081717
No.:23215-170639-082416
P.T.R. No.:7619391 DATE: 01-18-2017

3237
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
B SS KOI POND LINE
13000

R.A. 9266 SECTION 33


SECOND FLOOR LINE Drawings and specifications and other contract documents duly signed, stamped or
FCO sealed, as instruments of service are the intellectual property and documents of the

DN
architect, wether the object for which they are made is executed or not. It shall be
3000

12 13 14 15 16 17 18 19 20
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
11 10 9 8 7 6 5 4 3 2 1 without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

UP

UP
.
C

3262
SECOND FLOOR LINE

SECOND FLOOR LINE


KOI POND
2000
4000

.
D 1 2 3 4 5 6 CONSULTANT
2000

2000
KOI POND
VALIDITY:
P.T.R. No.: DATE:
SECOND FLOOR LINE PLACE: T.I.N. No.:

E 21037
REGISTERED MASTER PLUMBER

.
SECOND FLOOR LINE

UP
2000 3750 1575 3712 1463 4537 6000 2000
9037 6000 4925 1675
ROOF LINE ABOVE
ROLANDO H. SIBAYAN,

ROOF LINE ABOVE


RMP

2000

2000
REGISTERED MASTER
. PLUMBER
5587 2500 950 12000

1000
P.R.C. No.: 0007780 VALIDITY: 07-08-2018
P.T.R. No.: 8258581 DATE: 03-20-2017
4538 4500 6000 6000 PLACE: ROXAS, ISABELA T.I.N. No.:

21037 VC SS
PROJECT NAME
VC
A FCO

SP

4000
PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

3000
5500

SP
FCO
GROUND FLOOR PLAN

6000

SP
PROJECT LOCATION

SEWER LINE LAYOUT


FCO
SS
01

VAC
LUCAS SUBDIVISION,

VAC
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
P 3 SCALE: 1:100 METERS FCO

575 3925
VC

SP

4500
1500 OWNER
13200

ROOF LINE ABOVE

14000
FCO SS
B SP
VAC
VC
SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

DN
FCO
2675

12 13 14 15 16 17 18 19 20

VAC
SHEET CONTENTS

SP
11 10 9 8 7 6 5 4 3 2 1
5000

UP
BDRM. 04 AS SHOWN
C VC

4600
VC
2325

VAC
MASTER BDRM.

5500
FCO

D
1200

REVISIONS:
2000

E ROOF LINE ABOVE

1075
2000
ROOF LINE ABOVE

1675 3462 1963 2037 1463 4537 6000 2000


2000 4538 4500 6000 6625
SECOND FLOOR PLAN 22262 CHECKED BY: SHEET No.:

SEWER LINE LAYOUT R.SIBAYAN, rmp


02
P 3 SCALE: 1:100 METERS
CADD BY:

KDTALAUE
DATE:

07-20-17
P-3
SANITARY &
PLUMBING PLANS
A 1
..\..\..\Desktop\TAF Documents\TAF Logo.jpg

VE
BO
EA
LIN
RO
OF
2
B
C 3
D VC
4 TJ A. FLORES
SS ARCHITECTURAL DESIGN
E SP
+ CONSULTANCY
A FC
O FC 1
VC SP VA
C SP
O
5 UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
SP FC
O MOBILE No.: +(63) 917 594 4150
VA
C SS EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
DWWDWD
FC
O 2
B VA
C
6 TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
VC
C 3 PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020
4
DWWDWD

D RO
OF
FC
O
SS RO
OF
I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
E
LIN LIN
E E
AB SP R.A. 9266 SECTION 33
OV
E
SP MA
AB
OV Drawings and specifications and other contract documents duly signed, stamped or
IN VC E
sealed, as instruments of service are the intellectual property and documents of the

RL
INE FC
O SP
FC
O 5 architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
SP
repetition of and for other projects or buildings, wether executed partly or whole,
OO VC
FL VS without the written consent of the architect or author of the said documents.
ND SS
CO C DESIGN CONSULTANT
SE FC VA SP S
O MA SP C S
VS S
P IN SECO VA .
FC VC
O V VAC D FL
N
KO
IP
ON
D
C
VC
OO
RL
INE
VE
6
LIN BO
E EA
DP LIN
KO OF
IP RO
ON C SP
D VA M SE
CO SE
.
AIN ND
EE TA PT
FC (S
O VS FL
OO DE NK IC CO CONSULTANT
SENNE
R TA
LIN ILS VALIDITY:
E ) WE CT
R S TO P.T.R. No.: DATE:
YS EX PLACE: T.I.N. No.:
TE IST
M IN REGISTERED MASTER PLUMBER
RO
G
OF
L INE .
AB
OV
E FC
O
A 1
E
OV ROLANDO H. SIBAYAN, RMP
E AB
LIN

E
ROO
F
2 REGISTERED MASTER
P.R.C. No.: 0007780
. PLUMBER
VALIDITY: 07-08-2018

D
FL
O OR
LIN
B P.T.R. No.: 8258581
PLACE: ROXAS, ISABELA
DATE: 03-20-2017
N
CO
SE SE PROJECT NAME
CO

GROUND FLOOR PLAN ND


FL
O OR
C 3
LIN
E
D 4
SEWER LINE LAYOUT E
A
CW
L
GV
CW
L 3W H
V WL
L 1
PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE
HW CW
MP
5
ISOMETRIC VIEW
CW L LM
GV L HW 3W IN AI
3W CWL MA N
01 V
MP
MP CW
GV
V
L CW
L CW
R PROJECT LOCATION

WL

P 4 SCALE: 1:100 METERS


H
2 CW
LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
B
DWWDWD

LM
ISABELA 3305
AIN
6
OWNER
C 3
D CW 4 LM SPS. JUANITO A. AVANCENA
HB AIN RO
OFL BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
E GV 12
PR0 GA
1.5
HP
PU BO GV
INE
AB
OV
E
CW ES LS MP OS SHEET CONTENTS

LIN
E CW CW
L
L SU . C
RE AP
TA AC
TE
R CW
L
L
MP 5
OO
R L NK ITY HW L AS SHOWN
FL C
ON
D GV WR CW
EC L GV 80 3 WV
S
CW GV CV
HW
0L
WAGAL L
HB L W
GV SE MP TE S. C
CW CO GR C
3W
V
ND
L W L VTA APA
F NK C
G L
CNW
S
K.L
H W LO C
OR
LIN
E E
ITY
6
WL V C W BO
V
A
C INE
HB OFL
SN REVISIONS:
K. RO
CW
L
SE
CO
SE ND
CO FL
ND OO
FL R
OO L
RL M INE
INE CV
L
RO CW GV TA
HB P
SUWATTO M
OF
LIN
EA PP ER A
BO LY IN
VE

SECOND FLOOR PLAN


WATER LINE LAYOUT OR
L INE
LO CHECKED BY: SHEET No.:

ISOMETRIC VIEW D F
ON
EC R.SIBAYAN, rmp

P-4
02
SE S
CO
ND
FL
OO
CADD BY:
R
LIN

P 4 SCALE: 1:100 METERS


E

KDTALAUE
DATE: SANITARY &
07-20-17 PLUMBING PLANS
GENERAL NOTES and CONSTRUCTION NOTES :
GENERAL WELDING WORKS:
1. THESE CONSTRUCTION NOTES ARE SUPPLEMENTAL TO AND FORM PART OF WELDING OF STRUCTURAL STEEL SHALL BE DONE ONLY WHEN SHOWN ON THE PLANS
THE PLANS, DRAWINGS, AND SPECIFICATIONS. OR AUTHORIZED IN WRITING BY THE ENGINEER. ALL ARC WELDING ELECTRODES
SHALL CONFORM TO THE REQUIREMENTS OF AMERICAN WELDING SOCIETY
CONCRETE HOLLOW BLOCKS REINFORCEMENT
2. WHERE DETAILS OR REQUIREMENTS ARE NOT COVERED BY THE PLANS AND SPECIFICATIONS SURFACES TO BE WELDED SHALL BE SMOOTH, UNIFORM AND FREE BLOCK REINFOCEMENT NOTES
SPECIFICATIONS, THESE CONSTRUCTION NOTES SHALL BE USED IN SO FAR AS FROM FINS, TEARS AND OTHER DEFECTS WHICH WOULD ADVERSELY AFFECT THE THICKNESS
THEY ARE APPLICABLE TO SATISFY REQUIREMENTS OF GOOD CONSTRUCTION QUALITY OF THE WELD. (MM) HORIZONTAL VERTICAL A. MIN. LAP SPLICE = 300MM LONG
PRACTICE.
B. PROVIDE RIGHT ANGLE REINF. AT CORNERS
3. IN CASE OF QUESTIONS ARISING FROM THE INTERPRETATION OF OR CONFLICT
WITH OTHER DOCUMENTS, THE ATTENTION OF THE OWNER/ENGINEER SHALL BE
100 10mm dia. BARS @ EVERY
3RD LAYER OF CHB
10mm dia. BARS AT
600mm C/C 900MM LONG. TJ A. FLORES
CALLED IN WRITING. NOTES ON FOOTINGS/FOUNDATIONS: ARCHITECTURAL DESIGN
C. WHERE CHB WALLS ADJOIN COLUMNS,
4. ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS OTHERWISE NOTED. 1. NO FOOTINGS/MAT SHALL REST ON FILL. 150 12mm dia. BARS @ EVERY 12mm dia. BARS AT RC, BEAMS, & WALLS, DOWELS W/ THE SAME + CONSULTANCY
3RD LAYER OF CHB 600mm C/C UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
SIZE & SPACING AS THAT OF THE HORIZONTAL DISTRICT 1, CAUAYAN CITY, ISABELA 3305
5. IN THE INTERPRETATION OF THE DRAWINGS, INDICATED DIMENSION SHALL 2. FOOTINGS ARE DESIGNED TO REST ON SOIL SURFACE WITH ASSUMED BEARING & VERTICAL REINF. SHALL BE PROVIDED MOBILE No.: +(63) 917 594 4150
GOVERN, DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
CAPACITY AS SPECIFIED IN THE DESIGN CRITERIA. 12mm dia. BARS @ EVERY 12mm dia. BARS AT EXCEPT AS SPECIFIED
PURPOSES. 200
3RD LAYER OF CHB 600mm C/C
3. THE CONTRACTOR SHALL REPORT TO THE ENGINEER ACTUAL UNUSUAL SOIL
6. IN CASE OF DISCREPANCIES AS TO LAYOUT, DIMENSIONS, AND ELEVATION CONDITIONS UNCOVERED AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL IN
BETWEEN STRUCTURAL PLANS AND OTHER DRAWINGS, THE CONTRACTOR SHALL TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
WRITING BEFORE DEPOSITING CONCRETE.
NOTIFY BOTH THE STRUCTURAL ENGINEER AND THE OWNER'S REPRESENTATIVE PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020
OR SITE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE AFFECTED WORK.
I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
7. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ARCHITECT'S AND
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
OTHER ENGINEERING DISCIPLINE DRAWINGS.
DESIGN CRITERIA: R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
A. CODES AND REFERENCES: unlawful for any person to duplicate or make copies of said documents for use in the
1. NATIONAL STRUCTURAL CODE OF THE PHILIPPINES - 6TH EDITION 2010 repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.
2. ASEP - EARTHQUAKE RESISTANT DESIGN OF STRUCTURES - 1991 EDITION DESIGN CONSULTANT
3. UNIFORM BUILDING CODE - 1997 EDITION
CONCRETING WORKS: 4. ACI BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE - ACI 318-05
.

1. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE ACI-318-83 B. MATERIALS:
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. 1. CONCRETE
COMPRESSIVE STRENGTH OF CONCRETE @ 28 DAYS fc = 27.80 Mpa FOR FOUNDATION, FTB, PEDESTAL, SUSPENDED SLAB STEEL COLUMN
2. UNLESS OTHERWISE INDICATED IN PLANS OR NOTED IN THE SPECIFICATIONS, COMPRESSIVE STRENGTH OF CONCRETE @ 28 DAYS fc = 20.70 Mpa FOR WALL FOOTING AND SLAB ON GRADE -
THE MINIMUM 28TH DAYS CYLINDER COMPRESSIVE STRENGTH OF CONCRETE 2. REINFORCING STEEL
CONSULTANT
P.T.R. No.: VALIDITY:
SHALL BE AS SPECIFIED IN THE DESIGN CRITERIA. ALL REINFORCING STEEL SHALL BE DEFORMED CONFIRMING TO ASTM A 615 SPECIFICATIONS REINFORCE CONCRETE SLAB P.T.R. No.: DATE:
3. ALL REINFORCING BARS SHALL BE GRADE PS 275 WITH MINIMUM YIELD AND OF INTERMEDIATE GRADE EQUIVALENT PHILIPPINE TRADE STANDARD (PTS) GRADE 40 WITH 12mm @ 300 PLACE: T.I.N. No.:
MINIMUM YIELD STRENGTH fy = 414 Mpa FOR 16mm DIA. REBARS AND ABOVE STEEL GIRDER ENGINEER
STRENGTH AS SPECIFIED IN THE DESIGN CRITERIA.
MINIMUM YIELD STRENGTH fy = 276 Mpa FOR 12mm DIA. REBARS AND BELOW .
3. STRUCTURAL STEEL AND PLATES

110
4. ALL REINFORCING BARS SHALL BE DEFORMED IN ACCORDANCE WITH ASTM-615.
ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 SPECIFICATIONS WITH MINIMUM YIELD
5. ALL BENDS AND HOOKS OF BARS SHALL CONFORM TO THE REQUIREMENTS OF STRENGTH fy = 248 Mpa
ACI CODE.
4. ANCHOR AND FASTENER BOLTS 75 75 MC NEIL P. AGWAYAWAY, CE
6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR ALL BOLTS SHALL CONFORM TO ASTM A325 SPECIFICATIONS CIVIL ENGINEER
REINFORCEMENTS. 12mm @ 300 P.T.R. No.: 109609 VALIDITY: 04.05.2020
a. CONCRETE DEPOSITED DIRECTLY AGAINST GROUND .....................75mm 5. WELDING RODS P.T.R. No.: 1940351 DATE: JANUARY 18, 2017
PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847
b. FORMED CONCRETE IN CONTACT WITH GROUND .....................40mm ALL WELDING RODS SHALL BE MILD STEEL ELECTRODE, LOW HYDROGEN E7018 WITH
c. PRIMARY REINFORCEMENT, TIES & STIRRUPS OF BEAMS AND COLUMNS..40mm MINIMUM YIELD = 420 Mpa STEEL I-BEAM PROJECT NAME

d. SLAB ON FILL .....................40mm C. ALLOWABLE SOIL BEARING CAPACITY: FULL-WELD


SOIL BEARING CAPACITY = 105 KPa PROPOSED CONSTRUCTION OF
7. ALL ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE PROPERLY POSITIONED
PRIOR TO PLACING OF CONCRETE. D. LOADS: TWO STOREY RESIDENCE
1. DEAD LOAD
8. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, RE- a. CONCRETE = 24 Kn / cu. m
HANDLING OR FLOWING, PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, b. STEEL = 77 Kn / cu. m PROJECT LOCATION
BUCKETS OR WHEEL BORROWS OR BUCKETS IN WHICH CASE THEY SHALL NOT 2. LIVE LOAD
TYPICAL STEEL BEAM TO PC
EXCEED SIX (6) METERS IN AGGREGATE LENGTH. a. GROUND TO SECOND FLOOR = 2.88 KPa COLUMN TO BEAM CONNECTION SLAB CONNECTION DETAIL LUCAS SUBDIVISION,
SCALE NTS. SCALE NTS. BRGY. SAN FERMIN, CAUAYAN CITY,
9. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS b. ROOF 0.75 KPa
ISABELA 3305
UNLESS AUTHORIZED IN WRITING BY THE DESIGNER AND ONLY FOR UNUSUAL 3. SEISMIC LOAD : AS PER ASEP GUIDE - EARTHQUAKE RESISTANT DESIGN
CONDITION WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. OF STRUCTURES OWNER
4. WIND LOAD = 250 KPH STEEL COLUMN
10. CURING OF CONCRETE SHALL BE DONE IN ACCORDANCE WITH THE METHOD SPS. JUANITO A. AVANCENA
DESCRIBE IN THE SPECIFICATION. STEEL COLUMN BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

11. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ADEQUATE FORMS AND SHORING NOTES ON MASONRY WALLS: SHEET CONTENTS
UNTIL THE CONCRETE MEMBERS HAVE ATTAINED THEIR SUFFICIENT STRENGTH FOR
THE WORKING CONDITION ANTICIPATED. 1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE APPLICABLE STD. GENERAL NOTES
12. UNLESS OTHERWISE SPECIFIED THE SCHEDULE OF REMOVAL OF FORMS AND SHORES AND SPECIFICATIONS OF THE STRUCTURAL CODE OF THE PHILIPPINES AND UNIFORM BLDG. CODE.
OF THE FOLLOWING STRUCTURAL MEMBERS ARE AS FOLLOWS: 2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 GRADE N. PROVIDE STIFFENER PLATE
a. FOUNDATIONS ..............5 DAYS WHEN NO BEAM FRAMES STEEL JOIST
b. PEDESTAL, COLUMNS, AND WALLS ..............7 DAYS 3. MORTAR AND GROUT FOR ALL CONCRETE MASONRY SHALL CONFORM TO ASTM 270- TYPE M OPPOSITE THE INDICATED BEAM
AND SHALL HAVE A MINIMUM OF 28 DAYS STANDARD CYLINDER COMPRESSIVE STRENGTH OF WITH THICKNESS SAME AS THAT
c. BEAMS ..............21 DAYS OF THE CONNECTING BEAM WEB.
d. SLABS/SLABS ON GROUND ..............14 DAYS 17.5 MPa (2500psi). REVISIONS:

13. ALL SLAB REINFORCEMENTS SHALL HAVE A MINIMUM OF 20mm CLEAR COVER FROM 4. ALL CHB SHALL BE LAYED OUT WITH THE CELLS IN UNOBSTRUCTED VERTICAL CONTINUITY, ALL CELLS
THE BOTTOM AND FROM THE TOP OF THE SLAB. ESPECIALLY THOSE WITH REINFORCEMENT SHALL BE FILLED WITH MORTAR.
5. REINFORCEMENT, AS TABULATED BELOW, SHALL BE PROVIDED UNLESS OTHERWISE SPECIFIED STEEL COLUMN
14. UNLESS OTHERWISE NOTED IN PLANS, ALL BEDDED SLAB SHALL BE REINFORCED IN THE PLAN.
WITH 10mm REINFORCING BARS @ 300mm C/C, EACH WAY AT THE CENTER OF SLAB.
15. CONSTRUCTION JOINTS FOR BEDDED SLAB SHALL NOT BE MORE THAN 6.00MTS APART.

16. SAMPLING FOR COMPRESSIVE STRENGTH TESTS SHALL BE MADE IN ACCORDANCE


WITH THE SPECIFICATIONS.

17. DEVELOPMENT LENGTH FOR ALL BARS SHALL BE MINIMUM OF 60 BAR DIAMETER GIRDER TO JOIST CONNECTION
UNLESS OTHERWISE SPECIFIED. SCALE NTS.
CHECKED BY: SHEET No.:

MCPA
CADD BY:

MCPA
DATE:

07-20-17
S-1 STRUCTURAL
PLANS
1 2 3 4 5 6 1 2 3 4 5 6
21037 21037
4537 4500 1463 4537 6000 4537 4500 1463 4537 6000

FTB-1 FTB-1 FTB-1 FTB-1 GB-1 GB-1 GB-1 GB-1


A A
C1-F1 C1-F1 C1-F1 C3-F1 C3-F1
TJ A. FLORES

FTB-1
FTB-1

FTB-1

FTB-1

FTB-1

GB-1
GB-1

GB-1

GB-1

GB-1
6000

6000
ARCHITECTURAL DESIGN
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
FTB-1 FTB-1 FTB-1 FTB-1 GB-1 GB-1 GB-1 GB-1
B B
13000

13000
TRISTAN JAMES A. FLORES, UAP, PGBI-ADP
FTB-1

FTB-1

GB-1

GB-1
3000

3000
C1-F1 C4-F2 C3-F1 PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020
FTB-1

FTB-1

FTB-1

GB-1

GB-1

GB-1
I.A.P.O.A. No.:23215-200668-081717
FTB-1 GB-1 P.T.R. No.:7619391
PLACE: CAUAYAN CITY
DATE: 01-18-2017
T.I.N. No.: 276-677-312-000
C C R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or

GB-1
2000

2000
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the

FTB-1 C2-F3 C2-F3 FTB-1 GB-1 GB-1 repetition of and for other projects or buildings, wether executed partly or whole,

GB-1
without the written consent of the architect or author of the said documents.

D D DESIGN CONSULTANT
2000

2000
.

C1-F1 FTB-1 C3-F1 GB-1 GB-1


E E
-
C1-F1 C3-F4 CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:

01 LOWER FOUNDATION PLAN 02 GRADE BEAM FRAMING PLAN PLACE: T.I.N. No.:
ENGINEER

S 02 SCALE: 1:100 METERS S 02 SCALE: 1:100 METERS


MC NEIL P. AGWAYAWAY, CE
CIVIL ENGINEER
1 2 3 4 5 6 1 2 3 4 5 6 P.T.R. No.: 109609
P.T.R. No.: 1940351
VALIDITY: 04.05.2020
DATE: JANUARY 18, 2017
PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847

21037 21037 PROJECT NAME

4537 4500 1463 4537 6000 4537 4500 1463 4537 6000
PROPOSED CONSTRUCTION OF
USE 12mm DIA. TWO STOREY RESIDENCE
REBARS SPACED AT
250mm O.C.B.W. 2B-1 2B-1 2B-1 2B-1
PROJECT LOCATION
A A LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,

2B-4

2B-4
ISABELA 3305
OWNER
2B-5 2B-5

2B-2
2B-2

2B-6

2B-6
2B-4
6000

6000
S-1 S-1 S-1 S-1 SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

2B-4

2B-4
SHEET CONTENTS

2B-3 2B-3 2B-3 LOWER FOUNDATION PLAN


UPPER FOUNDATION PLAN
B B
13000

13000
GRADE SLAB FRAMING PLAN
2B-3 GRADE BEAM FRAMING PLAN
2B-7

2B-4

2B-4
3000

3000

S-1
2B-2

2B-2
2B-6
2B-4
S-1 S-1 2B-5 2B-5 REVISIONS:

C C
S-1

2B-4
2000

2000

2B-5 2B-5

2B-4
D D 2B-5

2B-6
2B-4

2B-2
2000

2000

2B-5 2B-5 2B-5 2B-5


E E

CHECKED BY: SHEET No.:

GRADE SLAB FRAMING PLAN SECOND FLOOR BEAM FRAMING PLAN MCPA
03
S 02 SCALE: 1:100 METERS
04
S 02 SCALE: 1:100 METERS
CADD BY:

MCPA
DATE:

07-20-17
S-2 STRUCTURAL
PLANS
1 2 3 4 5 6 1 2 3 4 5 6
21037 21037
4537 4500 1463 4537 6000 4537 4500 1463 4537 6000

RB-1 RB-1 RB-1 RB-1


A A

TJ A. FLORES

RB-1

RB-1
RB-2
RB-2

RB-2
6000

6000
S-2 S-2 S-2 S-2 ARCHITECTURAL DESIGN
+ CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com
RB-2 RB-2 RB-2 RB-2
B B
13000

13000
S-2 TRISTAN JAMES A. FLORES, UAP, PGBI-ADP

RB-2

RB-2
3000

3000
PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020

RB-1

RB-1
RB-2
I.A.P.O.A. No.:23215-200668-081717

S-2 RB-1 P.T.R. No.:7619391


PLACE: CAUAYAN CITY
DATE: 01-18-2017
T.I.N. No.: 276-677-312-000
C S-2 C R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or

RB-1
2000

2000
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the

RB-1 RB-1 repetition of and for other projects or buildings, wether executed partly or whole,
without the written consent of the architect or author of the said documents.

RB-1
D D DESIGN CONSULTANT
2000

2000
.

RB-1 RB-1
E E
-
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:

01 SECOND FLOOR SLAB FRAMING PLAN 02 ROOF BEAM FRAMING PLAN PLACE: T.I.N. No.:
ENGINEER

S 03 SCALE: 1:100 METERS S 03 SCALE: 1:100 METERS


MC NEIL P. AGWAYAWAY, CE
1 2 3 4 5 6 CIVIL ENGINEER
P.T.R. No.: 109609 VALIDITY: 04.05.2020
P.T.R. No.: 1940351 DATE: JANUARY 18, 2017
21037 PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847
PROJECT NAME
4537 4500 1463 4537 6000

PROPOSED CONSTRUCTION OF
TWO STOREY RESIDENCE

Sagrods at
mid-point PROJECT LOCATION
A 12mm diameter Round Bar
Cross Bracings 150mm THICK CHB WALL 100mm THICK CHB WALL LUCAS SUBDIVISION,
LC Purlins w/ 10mm Ø VERTICAL Re-BARS @ w/ 10mm Ø VERTICAL Re-BARS @ BRGY. SAN FERMIN, CAUAYAN CITY,
spaced @ 600mm O.C. 600mm O.C. and 10mm Ø 600mm O.C. and 10mm Ø ISABELA 3305
12inches Standard HORIZONTAL Re-BARS @ EVERY 3 HORIZONTAL Re-BARS @ EVERY 3
Turn Buckles CHB LAYERS CHB LAYERS OWNER
6000

SPS. JUANITO A. AVANCENA


FFL FFL
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

200.00
SHEET CONTENTS
3 - 12mm Ø

150.00
600.00
LONGITUDINAL BAR
SECOND FLOOR SLAB FRAMING PLAN
12mm Ø at 300mm O.C. ROOF BEAM FRAMING PLAN
B
13000

300.00 TRANSVERSE BAR ROOF FRAMING PLAN


3 - 12mm Ø WALL FOOTING DETAILS
LONGITUDINAL BAR
3000

200.00
12mm Ø at 300mm O.C.
WF - 2 REVISIONS:
300.00 TRANSVERSE BAR
C
2000

WF - 1
D
2000

E
04 WALL FOOTING DETAILS
S 03 SCALE: N T S CHECKED BY: SHEET No.:

ROOF FRAMING PLAN MCPA


03
S 03 SCALE: 1:100 METERS
CADD BY:

MCPA
DATE:

07-20-17
S-3 STRUCTURAL
PLANS
DIMENSIONS (MM) REINFORCEMENT
FOOTING
D W L T BAR BAR BAR BAR REMARKS
DESIGNATION (DEPTH) (WIDTH) (LENGTH) (THICKNESS) 'A' 'B' 'C' 'D'
ISOLATED
F1 2000 1500 1500 300 8 - 16mm Ø 8 - 16mm Ø 4 - 16mm Ø 4 - 16mm Ø FOOTING

ISOLATED
F2 2000 2000 2000 300 10 - 16mm Ø 10 - 16mm Ø 4 - 16mm Ø 4 - 16mm Ø FOOTING

F3 2000 1500 4500 300 8 - 16mm Ø 16 - 16mm Ø 4 - 16mm Ø 6 - 16mm Ø COMBINED FOOTING

F4 2000 1500 3500 300 8 -16mm Ø 14 - 16mm Ø 4 - 16mm Ø 6 - 16mm Ø COMBINED FOOTING
TJ A. FLORES
℄ ℄ ARCHITECTURAL DESIGN
+ CONSULTANCY
01 FOOTING SCHEDULE SECOND FLOOR SECOND FLOOR


UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
MOBILE No.: +(63) 917 594 4150
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

S 04 SCALE: N T S SECOND FLOOR

TRISTAN JAMES A. FLORES, UAP, PGBI-ADP

HEIGHT

HEIGHT
PRINCIPAL ARCHITECT
SEE SECTION SEE SECTION P.R.C. No.: 27108 VALIDITY: 03-10-2020

HEIGHT
I.A.P.O.A. No.:23215-200668-081717
100mm THICK SLAB ON FILL
SEE SECTION P.T.R. No.:7619391 DATE: 01-18-2017
w/ 10mm Ø REINFORCING BARS @
300mm O.C.B.W. on 100mm THICK PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
20mm THICK STEEL PLATE COMPACTED GRAVEL 20mm THICK STEEL PLATE R.A. 9266 SECTION 33
REINFORCED REINFORCED Drawings and specifications and other contract documents duly signed, stamped or
WITH 6 - 25mmØ WITH 6 - 25mmØ 100mm THICK SLAB ON FILL
MARK CONCRETE ANCHOR BOLT CONCRETE ANCHOR BOLT REINFORCED
20mm THICK STEEL PLATE
w/ 10mm Ø REINFORCING
sealed, as instruments of service are the intellectual property and documents of the
WITH 6 - 25mmØ architect, wether the object for which they are made is executed or not. It shall be
PEDESTAL COLUMN PEDESTAL COLUMN BARS @ 300mm O.C.B.W. on
C1 C2 C3 C4 GRADE BEAM (GB) GRADE BEAM (GB) GRADE BEAM (GB)
CONCRETE
PEDESTAL COLUMN
ANCHOR BOLT
100mm THICK COMPACTED
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,
REFER TO BEAM SCHEDULE REFER TO BEAM SCHEDULE REFER TO BEAM SCHEDULE
LOCATION GRAVEL without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

200
100100 200
TOP OF SLAB ON GRADE
.
TOP OF FOOTING
TO NATURAL GRADE LINE
PEDESTAL 200mm
ABOVE TOP OF
GRADE BEAM FOOTING TIE BEAM (FTB)
(REFER TO PLAN REFER TO BEAM SCHEDULE

FOOTING DEPTH
FOR COLUMN
CUT-OFF) FOOTING TIE BEAM (FTB) FOOTING TIE BEAM (FTB) -
350 mm x 350 mm 350 mm x 350 mm 400 mm x 400 mm 400 mm x 400 mm REFER TO BEAM SCHEDULE REFER TO BEAM SCHEDULE CONSULTANT
P.T.R. No.: VALIDITY:
MAIN BARS 8 - 20 mm Ø 8 - 20 mm Ø 12 - 20 mm Ø 12 - 20 mm Ø
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
12mm Ø; 2 SET HOOPS, 12mm Ø; 2 SETHOOPS, 12mm Ø; 3 SETHOOPS, 12mm Ø; 3 SET HOOPS,
LATERAL TIES 4 @ 75mm, 8 @ 150mm, REST @ 4 @ 50mm, 8 @ 100mm, REST @ 4 @ 75mm, 8 @ 100mm, REST @ 4 @ 75mm, 8 @ 100mm, REST @ ENGINEER
200mm ON CENTER 200mm ON CENTER 200mm ON CENTER 200mm ON CENTER
BAR 'C' BAR 'C' .
BAR 'D' BAR 'D'
PEDESTAL 200mm
FROM TOP OF

THICKNESS
GROUND FINISH
FLOOR LINE
TO
ROOF BEAM
BOTTOM OF FOOTING MC NEIL P. AGWAYAWAY, CE

100
W 310 x 79 W 310 x 79 W 310 x 86 W 310 x 97 CIVIL ENGINEER
WIDE FLANGE SECTION WIDE FLANGE SECTION WIDE FLANGE SECTION WIDE FLANGE SECTION P.T.R. No.: 109609 VALIDITY: 04.05.2020
(W-SHAPE) - resting on (W-SHAPE) - resting on (W-SHAPE) - resting on (W-SHAPE) - resting on P.T.R. No.: 1940351 DATE: JANUARY 18, 2017
REMARKS 300mmx300mmx16mm thick Base 300mmx300mmx16mm thick Base 400mmx400mmx16mm thick Base 400mmx400mmx16mm thick Base ADDITIONAL 20mmØ Re-BARS ADDITIONAL 20mmØ Re-BARS
Plate w/ 6-20mmØ High Tensile Plate w/ 6-20mmØ High Tensile Plate w/ 6-20mmØ High Tensile Plate w/ 6-20mmØ High Tensile BAR 'B' PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847
Anchor Bolts Anchor Bolts Anchor Bolts Anchor Bolts
for COLUMN DOWELS as shown BAR 'B' for COLUMN DOWELS as shown
BAR 'A' PROJECT NAME
3 SETS - 12mm Thick Steel Plate 3 SETS - 12mm Thick Steel Plate 3 SETS - 12mm Thick Steel Plate 3 SETS - 12mm Thick Steel Plate BAR 'A'
Column Stiffeners @ every Column Column Stiffeners @ every Column Column Stiffeners @ every Column Column Stiffeners @ every Column
WEB STIFFENERS Height Height Height Height
(Floor to Floor) (Floor to Floor) (Floor to Floor) (Floor to Floor)
GRID LINE GRID LINE
PROPOSED CONSTRUCTION OF
LENGTH GRID LINE TWO STOREY RESIDENCE

02 COLUMN SCHEDULE L/2 L/2

L/2
LENGTH

L/2 PROJECT LOCATION

S 04 SCALE: N T S LUCAS SUBDIVISION,


BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
W/2

OWNER

W/2
VERTICAL BAR SPS. JUANITO A. AVANCENA
WHERE OCCURS
GRID LINE

GRID LINE
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA
WIDTH

WIDTH
CHB
SHEET CONTENTS
2 - 12mm Ø
LINTEL BEAM (CHB width x 300mm)
FOOTING SCHEDULE
10mm Ø @ 150mm o.c.

W/2
COLUMN SCHEDULE
2 - 12mm Ø N O T E S:
W/2

FOOTING-COLUMN DETAILS
WALL OPENING

TYPICAL LINTEL/BOND BEAM DETAILS


1. UNLESS INDICATED
OTHERWISE USE RC LINTEL
BEAM AT THE TOP AND RC
REVISIONS:
BOND BEAM AT THE BOTTOM
2 - 12mm Ø OF ALL WALL OPENING

BOND BEAM (CHB width x 300mm) 2. ALL LINTEL AND BOND


10mm Ø @ 150mm o.c. BEAMS SHALL BE EMBEDDED
2 - 12mm Ø AT LEAT 600MM INTO THE
CHB
VERTICAL BAR
WHERE OCCURS
CHB WALL
TYPICAL COMBINED/STRIP TYPICAL ISOLATED
FOOTING-COLUMN DETAILS FOOTING-COLUMN DETAILS
04 TYPICAL LINTEL/BOND BEAM DETAILS
S 04 SCALE: N T S 03 FOOTING-COLUMN DETAILS CHECKED BY:

MCPA
SHEET No.:

S 04 SCALE: N T S CADD BY:

MCPA
DATE:

07-20-17
S-4 STRUCTURAL
PLANS
SIZE LONGITUDINAL REINFORCEMENT
BEAM WIDTH DEPTH
DESIGNATION BAR "A" BAR "B" BAR "C" BAR "D" BAR "E" BAR "F" BAR "G" BAR "H" BAR "I" BAR "J" WEB STIRR - UPS REMARKS
B (mm) D (mm) BARS

FOOTING TIE BEAMS

FTB - 1 300 400 4 - 16mm Ø 3 - 16mm Ø 1 - 16mm Ø 1 - 16mm Ø 1 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2- 16mm Ø 2- 16mm Ø ---------- B CONTINUOUS BEAM

GRADE BEAMS

GB - 1 300 400 4 - 16mm Ø 4 - 16mm Ø 1 - 16mm Ø 1 - 16mm Ø 1 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2- 16mm Ø 2- 16mm Ø ---------- A CONTINUOUS BEAM

NOTES ON STIRR - UPS: TJ A. FLORES


A - 10mm Ø, 4 @ 50mm, 8 @ 100mm rest @ 180mm TO CENTER ARCHITECTURAL DESIGN
B - 10mm Ø, 3 @ 50mm, 6 @ 100mm rest @ 200mm TO CENTER FLANGE WEB + CONSULTANCY
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
BEAM DESIGNATION DISTRICT 1, CAUAYAN CITY, ISABELA 3305
THEORETICAL
AREA DEPTH WIDTH THICKNESS THICKNESS REMARKS MOBILE No.: +(63) 917 594 4150
MASS

REINFORCED CONCRETE BEAM SCHEDULE (kg/m)


2
(mm ) (mm) (mm) (mm) (mm)
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

01 SECOND FLOOR BEAMS

S 05 SCALE: N T S 2B - 1 W 250 x 39 38.7 4 920 262 147 11.2 6.6 WIDE FLANGE (W-SHAPE)
TRISTAN JAMES A. FLORES,
PRINCIPAL ARCHITECT
UAP, PGBI-ADP

P.R.C. No.: 27108 VALIDITY: 03-10-2020


2B - 2 W 250 x 39 38.7 4 920 262 147 11.2 6.6 WIDE FLANGE (W-SHAPE) I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
2B - 3 W 250 x 45 44.9 5 720 266 148 13.0 7.6 WIDE FLANGE (W-SHAPE) R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be

GRID GRID BAR "D" EXTRA TOP BARS GRID 2B - 4 W 250 x 45 44.9 5 720 266 148 13.0 7.6 WIDE FLANGE (W-SHAPE) unlawful for any person to duplicate or make copies of said documents for use in the
BAR "A: CONT. repetition of and for other projects or buildings, wether executed partly or whole,

TOP BARS (FIRST INTERIOR SUPPORT) without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT
BAR "E" EXTRA TOP BARS 2B - 5 W 250 x 45 44.9 5 720 266 148 13.0 7.6 WIDE FLANGE (W-SHAPE)
L1/ 3 L1/ 3 L2/ 3 L2/ 3 .
(INTERIOR SUPPORT)
WEB BARS 2B - 6 W 200 x 27 26.6 3 390 207 133 8.4 5.8 WIDE FLANGE (W-SHAPE)
(2 - 12mmØ)
2B - 7 W 200 x 27 26.6 3 390 207 133 8.4 5.8 WIDE FLANGE (W-SHAPE)
-
CONSULTANT
ROOF BEAMS P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
RB - 1 W 150 x 30 29.8 3 790 157 153 9.3 6.6 WIDE FLANGE (W-SHAPE) PLACE: T.I.N. No.:
BAR "F" EXTRA BOT. ENGINEER

BARS (EXTERIOR SUPPORT) BAR "G" EXTRA BOTTOM .


RB - 2 W 150 x 22 22.3 2 850 152 152 6.6 5.8 WIDE FLANGE (W-SHAPE)
BARS (INTERIOR SPAN)
L1/ 5 L1/ 5 L2/ 5 L2/ 5
BAR "J" EXTRA BOTTOM BARS
L1 L2 (INTERIOR SUPPORT)
BAR "H" EXTRA BOTTOM BARS
(EXTERIOR SUPPORT)
BAR "I" EXTRA BOTTOM BARS
(FIRST INTERIOR SPAN) 04 STRUCTURAL STEEL BEAM SCHEDULE MC NEIL P. AGWAYAWAY, CE

P.T.R. No.: 109609


P.T.R. No.: 1940351
CIVIL ENGINEER
VALIDITY: 04.05.2020
DATE: JANUARY 18, 2017
BAR "B: CONT. BOTTOM BARS
(EXTERIOR SPAN) S 05 SCALE: N T S PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847
PROJECT NAME

PROPOSED CONSTRUCTION OF

02 REINFORCED CONCRETE BEAM DETAILS WEB STIFFENER


TWO STOREY RESIDENCE

3 ON EVERY COLUMN HEIGHT


S 05 SCALE: N T S GRID GRID
PROJECT LOCATION

L LUCAS SUBDIVISION,
BRGY. SAN FERMIN, CAUAYAN CITY,
ISABELA 3305
WIDE FLANGE SLAB
OWNER
STEEL BEAM ON STEEL DECK
A SPS. JUANITO A. AVANCENA
BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

SHEET CONTENTS
L
L/3 L/3 L/3 REINFORCED CONCRETE BEAM
SCHEDULE and DETAILS
STRUCTURAL STEEL BEAM
SCHEDULE and DETAILS
TOP BARS TYPICAL REINFORCED CONCRETE BEAM
WIDE FLANGE SPLICE DETAILS
STEEL BEAM
A SECTION A - A REVISIONS:
D

BOTTOM BARS

2D
EXTRA STIRRUP TIES
05 STRUCTURAL STEEL BEAM DETAILS
NO SPLICE S 05 SCALE: N T S
TYPICAL SPLICE DETAILS FOR BEAMS FRAMING INTO COLUMNS

03 TYPICAL REINFORCED CONCRETE BEAM SPLICE DETAILS CHECKED BY:

MCPA
SHEET No.:

S 05 SCALE: N T S
CADD BY:

MCPA
DATE:

07-20-17
S-5 STRUCTURAL
PLANS
A'
B'
300

C'
D TJ A. FLORES
ARCHITECTURAL DESIGN
E + CONSULTANCY
500 C
500 500
UNIT R-2, GF VITRIOLO BUILDING, DR. B. REYES ST.,
DISTRICT 1, CAUAYAN CITY, ISABELA 3305
VERIFY

MOBILE No.: +(63) 917 594 4150


500 500
EMAIL: tjaflores@yahoo.com / tjafloresadc@gmail.com

500 500 500 TRISTAN JAMES A. FLORES, UAP, PGBI-ADP


500 500
PRINCIPAL ARCHITECT
P.R.C. No.: 27108 VALIDITY: 03-10-2020
500 500
I.A.P.O.A. No.:23215-200668-081717
P.T.R. No.:7619391 DATE: 01-18-2017

500 500
PLACE: CAUAYAN CITY T.I.N. No.: 276-677-312-000
R.A. 9266 SECTION 33
Drawings and specifications and other contract documents duly signed, stamped or

500 500
sealed, as instruments of service are the intellectual property and documents of the
architect, wether the object for which they are made is executed or not. It shall be
unlawful for any person to duplicate or make copies of said documents for use in the
repetition of and for other projects or buildings, wether executed partly or whole,

VERIFY without the written consent of the architect or author of the said documents.

DESIGN CONSULTANT

01 TYPICAL TRUSS/RAFTER DIAGRAM and DETAILS


S 06 SCALE: N T S -
CONSULTANT
P.T.R. No.: VALIDITY:
P.T.R. No.: DATE:
PLACE: T.I.N. No.:
LEGEND ENGINEER

ROOF FRAMING Ll (cc)


.

Ll (n)
∠ 55 x 55 x 5 mm TOP CHORD 2 ∠s 55 x 55 x 5 mm TOP CHORD

whichever is smaller
A PAINTED / FULLY - WELDED A' PAINTED / FULLY - WELDED

Ls/4 or Ll/4
MC NEIL P. AGWAYAWAY, CE
column strip
∠ 55 x 55 x 5 mm BOTTOM CHORD 2 ∠s 55 x 55 x 5 mm BOTTOM CHORD CIVIL ENGINEER
B PAINTED / FULLY - WELDED B' PAINTED / FULLY - WELDED P.T.R. No.: 109609 VALIDITY: 04.05.2020

strip
P.T.R. No.: 1940351 DATE: JANUARY 18, 2017

column strip

column strip
PLACE: NUEVA VIZCAYA T.I.N. No.: 943 - 661 - 847
PROJECT NAME

Ls (cc)
∠ 55 x 5 x 5mm WEB MEMBERS 2 ∠s 55 x 5 x 5mm WEB MEMBERS

Ls (n)
middle strip
C PAINTED / FULLY - WELDED C' PAINTED / FULLY - WELDED

middle
PROPOSED CONSTRUCTION OF

whichever is smaller
10mm Ø PLAIN ROUND BAR SAG ROD TWO STOREY RESIDENCE
D

Ls/4 or Ll/4
PLACED AS SHOWN w/ STANDARD NUT &
WASHER PAINTED column strip
PROJECT LOCATION
Ga. 24 - 100 x 50 mm C - PURLINS SPACE
E AT 700mm ON CENTER OR AS INDICATED 12mm dia. LUCAS SUBDIVISION,
Ls/4 or Ll/4 Ls/4 or Ll/4
PAINTED (PROVIDE 45mm x 45mm x 3mm main bars BRGY. SAN FERMIN, CAUAYAN CITY,
BAR CLEATS) whichever is smaller whichever is smaller ISABELA 3305
10mm dia. OWNER

LONG SPAN temp. bars


SPS. JUANITO A. AVANCENA
LONG SPAN BRGY.SAN FERMIN, CAUAYAN CITY, ISABELA

SHEET CONTENTS
STEEL REINFORCEMENT
MARK t (mm) TYPICAL TRUSS/RAFTER
SHORT SPAN LONG SPAN REMARKS DIAGRAM and DETAILS
SLAB SCHEDULE
TYPICAL SLAB DETAILS
SHORT SPAN

MIDDLE STRIP COLUMN STRIP MIDDLE STRIP COLUMN STRIP

SHORT SPAN
12mmØ @ 250mm 12mmØ @ 250mm
GS - 1 125 SLAB ON GRADE
on center BOTH WAYS on center BOTH WAYS
REVISIONS:

12mmØ @ 180mm 12mmØ @ 180mm


2S - 1 125 ONE - WAY SLAB
on center BU 2/3 on center BU 1/3

12mmØ @ 180mm 12mmØ @ 200mm 12mmØ @ 180mm 12mmØ @ 200mm


2S - 2 125 TWO - WAY SLAB
on center BU 2/3 on center BU 2/3 on center BU 1/3 on center BU 1/3

02 SLAB SCHEDULE SLAB S-1 SLAB S-2


S 06 SCALE: N T S
TYPICAL SLAB DETAILS
CHECKED BY: SHEET No.:

MCPA
03
S 06 SCALE: N T S
CADD BY:

MCPA
DATE:

07-20-17
S-6 STRUCTURAL