ABUTMENT PILE CAP 10500

Ø16@300 C/C
300 Ø16@300 C/C Ø16@300 C/C
(ADDITIONAL)
(ADDITIONAL) (ADDITIONAL)
1200

800
BACK WALL REINF.
500
2000

Ø12@75
PITCH

2000
14-Ø20 (T)

@NSZ

1000
Ø12@200
(4-LEGGED STIRRUPS)

A A
9.304m

1000
3+3Ø12 3+3Ø12
3+3 Ø12
Ø12@75 4 LEDGED STIRRUPS C
PITCH Ø12@200

40-Ø25
14-Ø20 (T)
1430
STIRRUPS
Ø12@400

Ø12@75
1500
LAP

PITCH
2750

3-Ø12 (RINGS)
1000 Y
SHEAR KEY TO BE CAST
AFTER PLACING OF GIRDER
HELIX
10.5m

10 1980 10
Ø12@75

100
PITCH
$

VARIES
455
355
40-Ø25
40-Ø25
20 PAIR
Stiffeners Ø25@2000c/c

420
14-Ø16 10mm SHEET EXTRUDED POLYSTYRENE
BETWEEN SHEAR KEY & GIRDERS

Ø12@75
SECTION A-A 3-Ø16
Y
1500
LAP

PITCH
SECTION X-X OF SHEAR KEY
1000
DIAPHRAGM

HELIX
3-Ø12 (RINGS)
3-Ø12 (RINGS) 3-Ø16
B B
12m

100

300
26-Ø25
26-Ø25 X X
14-Ø16
Ø12@150 1980
PITCH
Stiffeners Ø25@2000c/c
PLAN OF SHEAR KEY
SECTION B-B 25mm THICK EXTRUDED POLYSTYRENE
SHEET BETWEEN DIAPHRAGM & SHEAR KEYS
14-Ø16

$ THE
LENGTH OF PILE WILL BE TAKEN FROM
3-Ø16
TABLE SHOWN IN Dwg No.A-004 & A-005
REINF. OF ABUT. PILES @
NSZ (NO SPLICE ZONE)
(TYPICAL PILE) SECTION Y-Y OF SHEAR KEY DATE
REVISED
DEC, 2017

CECON 04 DESIGNED BY Dr. M IQBAL


REINF. OF ABUT. PILES & TRANSOM
Civil Engineers & Consultants NATIONAL HIGHWAY AUTHORITY 03
02
DRAWN BY

CHECKED BY
ARIF RAO

HASSAM ULLAH
SWAN BRIDGE (NBC) RAWAT SIDE
N TS
H# 470, Street 17,Chaklala Scheme 3 Rawalpindi
E-mail:cecon.rwp@gmail.com URL:www.cmiqbal.com
ISLAMABAD 01 Km: 1534 (N-5) DATE DWG. NO.