You are on page 1of 1

34'

35'

603
0
907
5 36'
33'

R I
P R

670
A P

0
TRENC
H DRAIN O R
B E 37'
UTIL. / R M
00
STORAGE

LI T
90

NE
ENGINEERING

ER ES
32'
STORAGE UP

AT H
SERVICE
STAIRS

AIN
W HIG

DR
CH
K

EN
TR
C
Y
A

BA
ENGINEERING W 38'

K
00
STORAGE E

T
90
V

AC
31' I

SE
M R
R D

TB
E

m
B

SE
30
AIN
R M

CK
DR
CH
O EN R
TR
8 CAR SLOT E

m
B

A
P
A

TB

50
R ENGINEERING R
89
75
P 8 CAR SLOT O
I STORAGE

SE
30' DR
AIN
P
R EN
CH
A
TR
R

m
P
I

20
R
29' Y

K
AC
6
A

TB
531

SE
W

m
50
E
14' 15' 16' 17' 18' 19' 20' 22' 22' 24' 25' 26' 27' V
I
28' R
4 D

ALL
460
UTILITY

W
PICK-UP BAY

G
IN
AIN
RET
8 AIN
434 DR
CH
EN
TR

O ELECTRICAL
0
470 ROOM
ELEV 8

R I B E
TR ENCH
DRAIN
ELEV 6

D
9
10 8

P R R M
11 23 7
12
22 6

IN
13

I V
21 5
ELEV 5 Y

DRA
14 20
15 4
19 3
18
A

CH
2

A P
17 1
UP

TREN
E
16

MRF W
E

CK

W
V
I

O R
N R

Y
D 4 CAR SLOT
ELEVATOR
LOBBY
M
UP

DROP-OFF
SEE FOUNDATION PLAN

L
L
A
W
K P
A IN A
DR R
I P

L
CH

WAL
EN

R
TR

INING
RETA

UP
45 45 450 450 450 460
00 00 0 0 0
0

P-
7 CAR SLOT

M
RA
20 21 22 D R I V E W A Y
23
9 10 11 12 13 14 15 16 17 18 19 24 25 26 27 28 29 30 31 32 33 34
J

TRENCH DRAIN
TB
M'
GUARD

E
POST

N
IN
DRA
NCH

LI
TRE

K
Y M
A

ER
W R
E

RA
E B
I V

MP
AT
R R

-D
D O
L'

N
P

W
IN

L
DRA
A

WAL
NCH
R

25,000GALS CAP.

RE
ALL
TRE
I I P

RESERVE TANK
NON POTABLE
ST

TA
G
11 CAR SLOT

W
R

ININ

ININ
G
IN
E

AIN

TA

GW
100,000GALS CAP.

GH

RET

RE

R
18,000GALS CAP.

AC
AL
3A 4A 5A 6A 7A 8A 9A 10A 11A 12A

18,000GALS CAP.
30,000GALS CAP.
RAIN WATER

I P
L
RESERVE TANK
FIRE RESERVE

RESERVE
POTABLE
HI
DETENTION TANK

TANK

POTABLE

R
35366

TANK
RETAINING WALL
H

IN
DRA
3 730 4432 3650 4500 4500 5413 4368 4773

SE
SEWAGE TREATMENT

NCH
BT
FACILITY

TRE
LP4/LP5/LP6/BACK UP

O
4500

R
PUMP ROOM J'

B
6175

E
G

R
BT

CK

M
LP1/LP2/LP3/BACK UP

L
RETAINING WALL RETAINING WALL RETAINING WALL

AL
A

GW
46 00
11

KA

TB
10
9

ININ
12

ELEVATOR ELEVATOR 13 8
K'

1500
SERVICE HALLWAY 14
7
6
LOBBY 15

SE
EXISTING JA

TA
LOBBY 16
17
5
4
3

RE
18
19 2
F

1500
1
20 1
UP UP

BUILDINGIA
2

m
21
3
22

RE
4

617
5

TB
(VERIFY ACTUAL) ELEV 9

20

TA
6
7

IN
HA SERVER

4500
8
CCTV ROOM

1 500
ADMINISTRATION

IN G
9 4

1 8 17 1 6 1 5 1 4 1 3 1 2 10
ROOM UTIL. 2
3

GA I'

WAL
11 1
UP

K
0

OFFICES

Y
1 500
450

AC

A
L
FA

LLW
6
E

405
5

EA 4

TB

HA
3
2 20 00

1632
16 69
1

m
FIRE

IC E
SE
DA EXIT FIRE COMMAND

4500

RV
CENTER

SE
LA NDSCAP H'

m
0
OTH ERSE BY

LANDSCAPE
OPEN 450
TO ABOVE

30
D
LANDS
CAPE
OTHER BY
S
BY
ADMIN.
EMPLOYEE
DELIVERY
OTHERS

AD

4500
21708 DOCK
ENTRANCE

RO

K
G'

WAL
DN
CA 0

ICE
MP 450
RA

TH
SERV
C

SE
PA
101°

20 00

30

L
MAIN

AL
6010

445 0
ELECTRICAL

GW
DELIVERY 22

GENSET ROOM 21
ROOM F'

ININ
BAY UP

A CK
20
1 0
19
A=69.00 SQ.M 450

TB
2
ENGINEERING

K
18

SE
3

TA
17

m
4

12734

50
16
STORAGE B 5

RE
11610
6 15
BA 7
8
14
13
9 12
10 11

2754
A
E'

5600
0
450
551

5581

AA UTILITY ACCESS ROAD


AC TO UTILITY
970

3013
17 385

1314

3161
450
0
D'

m
0
450
BUILDING
279
574 2 7

C'
1A 2A 1 2 3 4 5 6 7 8

B'

A CK
TB
TB

SE

50
m
50
SE

KEYPLAN
m

SCALE NTS
20

29'

K
AC
TB
SE
m
50
14' 15' 16' 17' 18' 19' 20' 22' 22' 24' 25' 26' 1 27'
A - 101.2
28'
04
46
L
AL
W
NG
NI
T AI
RE

4 8
43

O
00
47

TREN
CH DR
AIN
9
10 8
11 7
12 23
22 6
13
14 21 5
15 20 4
19 3
18 2
UP
17
1
16

SEE FOUNDATION PLAN

LL
WA
ING
AIN
45

RET
00

20 21 22
23
11 12 13 14 15 16 17 18 19 24 25 26 27 28
J

TRENCH DRAIN
M'
POST
1 1
A - 101.1 A - 101.1

RA
M P-
DN
L' AIN
LL

H DR
C
EN
WA
25,000GALS CAP.

TR
RE

I
RESERVE TANK
NON POTABLE

TA
NG

INI
INI

1
TA

100,000GALS CAP.
GW

A - 101.2
RE

AL

7A 8A 9A 10A 11A 12A RAIN WATER


L

DETENTION TANK FOR BIDDING


TANK

35366
RETAINING WALL DATE : 2019 JUNE 14
4500 5413 4368 4773
H

HOT AND COLD WATER LINE LAYOUT


1 LOWER GROUND FLOOR PLAN - 1
P-02 SCALE 1 : 100 MTS

REVISIONS CADD BY DATE


These drawings are documents of
Information to be used only by the
405 Greenbelt Mansion,
Architect and the General Contractor. PROPOSED THE BELLEVUE HOT AND COLD WATER LINE LAYOUT FNB COM - 17-06-01
106 Perea St., Legaspi Village
1226 Makati City They are the sole property of BELLESOUTH PACIFIC 04-05-19
Tel. +632.478.3445, +632.818.1111 loc. 252
Fax +632.817.4471
John Patrick Anthony L. Buensalido
7347520 0019481
RESORT - PHASE 2 PROPERTIES INC.
RAMIL S. GUTIERREZ
and cannot be copied nor reproduced

P 02
design@buensalidoarchitects.com
www.buensalidoarchitects.com 01 JAN 2019 15 Feb 2005 without their written permission.
Makati City 31 Jan 2020 REP. ACT 9266 BRGY. DOLJO, PANGLAO ISLAND, BOHOL

You might also like