Total compressive load= 18 Kn

Length of columne 1 Mtr factor 1


Effective length of column in x direction 1 mtr
Effective length of column in y direction 1 mtr
yield stregth of stee 310 n/mm2
PROVIDE SECTION
PROVIDE SECTION = 32x32x2
AREA (A) = 2.3 cm2 = 230 mm2
rx = 1.21 mm = 12.1 mm
ry = 1.21 mm = 12.1 mm
ZX = 2.1
ZY = 2.10
Slender ration in x direction 82.64
slender ration in y direction 82.64
Maximum slenderness ratio 82.64
MAXIMUM Fibre stress 167.07 N/MM2

Allowable axial compressive load = 167.07X230


= 38426.1 N
= 38.43 Kn

section is safe