You are on page 1of 11

INE s CCIE Data Center v2

Nexus Wiring Diagram


© INE Inc.

Rack 1 C200-1 C200-2 C200-3


Rack 3 Rack 5

Ten0 Ten1 Ten0 Ten1 Ten0 Ten1

E101/1/1
Server1 Server2 E102/1/1 E101/1/1
Server5 Server6 E102/1/1 Server9 Server10
E101/1/1 E102/1/1

N2K3 N2K4 N2K5 N2K6 N2K7 N2K8


Ten0 Ten1 Ten0 Ten1 Ten0 Ten1 Ten0 Ten1 Ten1
Ten0 Ten1 Ten0

E1/1 E1/1 E1/1 E1/1 E1/1 E1/1


E1/2 E1/2 E1/2
E1/21 - 22 E1/2 E1/23 - 24 E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/2 E1/23 - 24 E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/2 E1/23 - 24 E1/21 - 22 E1/23 - 24

E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4


N5K1 N5K2 N5K5 N5K6 N5K9 N5K10

E1/5 E1/6 E1/5 E1/6 E1/5 E1/6 E1/5 E1/6 E1/6 E1/5
E1/5 E1/6

E1/3 E1/4 E1/4 E1/19 E1/20 E1/19 E1/20 E1/35


E1/3 E1/36 E1/35 E1/36

E1/1 - 2 E1/1 - 2 E1/17 - 18 E1/17 - 18 E1/33-34 E1/33-34


N7K1 N7K2 N7K5 N7K6 N7K9 N7K10

E1/6 E1/5 E1/22 E1/38


E1/21 E1/37
E1/5 E1/6 E1/21 E1/22 E1/37 E1/38

E1/13 E1/29 E1/30 E1/45 E1/46


E1/14 E1/13 E1/14 E1/30 E1/29 E1/46 E1/45

N7K3 N7K4 N7K7 N7K8 N7K11 N7K12


E1/9 - 10 E1/9 - 10 E1/25 - 26 E1/25 - 26 E1/41 - 42 E1/41 - 42

E1/12 E1/11 E1/28 E1/27 E1/44 E1/43


E1/12 E1/28
E1/11 E1/27 E1/43 E1/44

E1/6 E1/5 E1/6 E1/6 E1/5 E1/6 E1/6 E1/5


E1/5 E1/5 E1/5 E1/6

N5K3 E1/3 - 4 E1/3 - 4 N5K4 N5K7 E1/3 - 4 E1/3 - 4 N5K8 N5K11 E1/3 - 4
N5K12
E1/3 - 4

E1/21 - 22 E1/1 E1/23 - 24 E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/1 E1/23 - 24 E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/23 - 24
E1/1 E1/1 E1/1 E1/1
E1/2 E1/2 E1/2
E1/2 E1/2 E1/2

Ten0 Ten1 Ten0 Ten1 Ten0 Ten1 Ten0 Ten1 Ten1


Ten0 Ten1 Ten0
N2K3 N2K4 N2K5 N2K6 N2K7 N2K8

E101/1/1 E102/1/1 E101/1/1 E102/1/1 E101/1/1 E102/1/1


Server3 Server4 Server7 Server8 Server11 Server12

Ten0 Ten1 Ten0 Ten1 Ten0 Ten1

Rack 2 Rack 4 Rack 6


C200-1 C200-2 C200-3

www.INE.com
C220 M4 INE s CCIE Data Center v2
ACI Wiring Diagram
© INE Inc.

Ten0 Ten1

N9K
APIC M2 E101/1/1 E102/1/1 Spine1
N2K1 N2K2
Ten1 E1/1

Ten0 E1/2

E1/44 - 47 E1/44 - 47
E1/49
E1/48
E1/49 E1/48
N9K N9K
Leaf1 Leaf2
E1/10 E1/3
E1/1 E1/11 E1/12 E1/1 E1/2 E1/12
E1/4 E1/9
E1/2 E1/7 E1/6 E1/11
E1/5 E1/8 E1/9 E1/4 E1/5 E1/8
E1/3 E1/6 E1/7 E1/10

E1/7 E1/7 E1/15 E1/15 E1/23 E1/32 E1/40 E1/40 E1/48 E1/48
E1/24 E1/31
E1/8 E1/8 E1/16 E1/16 E1/24 E1/31 E1/39 E1/39 E1/47 E1/47
E1/23 E1/32

N7K1 N7K2 N7K3 N7K4 N7K5 N7K6 N7K7 N7K8 N7K9 N7K10 N7K11 N7K12

www.INE.com
INE s CCIE Data Center v2
Storage & UCS
Wiring Diagram
© INE Inc.

Rack 1 UCS2 Rack 3 UCS2 Rack 5 UCS2


B5108 B5108 B5108

UCS2 UCS2 UCS2 UCS2 UCS2 UCS2


FI-A E1/1 - 2 E1/1 - 2 FI-B FI-A E1/1 - 2 E1/1 - 2 FI-B FI-A E1/1 - 2 E1/1 - 2 FI-B

E1/5 E1/5 E1/11 E1/11 E1/17 E1/17


FC1/31 - 32 FC1/31 - 32 FC1/27 - 28 FC1/27 - 28 FC1/23 - 24 FC1/23 - 24
E1/3 - 4 E1/3 - 4 E1/9 - 10 E1/9 - 10 E1/15 - 16 E1/15 - 16

FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45


E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13
FC SAN A FC SAN B FC SAN A FC SAN B FC SAN A FC SAN B
FC1/48 FC1/48 FC1/48 FC1/48 FC1/48 FC1/48
E1/14 E1/14 E1/14 E1/14 E1/14 E1/14

N5K1 N5K2 N5K5 N5K6 N5K9 N5K10


E1/11 E1/11 E1/11 E1/11 E1/11 E1/11
E1/15 E1/15 E1/15
E1/15 E1/15 E1/15
E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10
FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47

E1/3 - 4 E1/3 - 4 E1/9 - 10 E1/9 - 10 E1/15 - 16 E1/15 - 16


iSCSI SAN A iSCSI SAN B iSCSI SAN A iSCSI SAN B iSCSI SAN A iSCSI SAN B
FC1/31 - 32 FC1/31 - 32 FC1/27 - 28 FC1/27 - 28 FC1/23 - 24 FC1/23 - 24
E1/5 E1/5 E1/11 E1/11 E1/17 E1/17

UCS1 UCS1 UCS1


E1/1 - 2 B5108 E1/1 - 2 E1/1 - 2 B5108 E1/1 - 2 E1/1 - 2 B5108 E1/1 - 2
UCS1 UCS1 UCS1 UCS1 UCS1 UCS1
FI-A FI-B FI-A FI-B FI-A FI-B

Rack 2 UCS2 Rack 4 UCS2 Rack 6 UCS2


B5108 B5108 B5108

UCS2 UCS2 UCS2 UCS2 UCS2 UCS2


FI-A E1/1 - 2 E1/1 - 2 FI-B FI-A E1/1 - 2 E1/1 - 2 FI-B FI-A E1/1 - 2 E1/1 - 2 FI-B

E1/8 E1/8 E1/15 E1/15 E1/20 E1/20


FC1/29 - 30 FC1/29 - 30 FC1/25 - 26 FC1/25 - 26 FC1/21 - 22 FC1/21 - 22
E1/6 - 7 E1/6 - 7 E1/12 - 13 E1/3 - 4 E1/18 - 19 E1/18 - 19

FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45 FC1/44 - 45


E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13 E1/12 - 13
FC SAN A FC SAN B FC SAN A FC SAN B FC SAN A FC SAN B
FC1/48 FC1/48 FC1/48 FC1/48 FC1/48 FC1/48
E1/14 E1/14 E1/14 E1/14 E1/14 E1/14

N5K3 N5K4 N5K7 N5K8 N5K11 N5K12


E1/11 E1/11 E1/11 E1/11 E1/11 E1/11
E1/15 E1/15 E1/15
E1/15 E1/15 E1/15
E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10 E1/9 - 10
FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47 FC1/46 - 47

E1/6 - 7 E1/6 - 7 E1/12 - 13 E1/12 - 13 E1/18 - 19 E1/18 - 19


iSCSI SAN A iSCSI SAN B iSCSI SAN A iSCSI SAN B iSCSI SAN A iSCSI SAN B
FC1/29 - 30 FC1/29 - 30 FC1/25 - 26 FC1/25 - 26 FC1/21 - 22 FC1/21 - 22
E1/8 E1/8 E1/14 E1/14 E1/20 E1/20

UCS1 UCS1 UCS1


E1/1 - 2 B5108 E1/1 - 2 E1/1 - 2 B5108 E1/1 - 2 E1/1 - 2 B5108 E1/1 - 2
UCS1 UCS1 UCS1 UCS1 UCS1 UCS1
FI-A FI-B FI-A FI-B FI-A FI-B

www.INE.com
INE s CCIE Data Center v2
VXLAN Wiring Diagram
N7K1 N7K2 © INE Inc.

E1/44 E1/4
E1/3 E1/3 E1/19
E1/43 E1/11
E1/12 E1/20 E1/28 E1/20 E1/28 E1/36 E1/44
E1/36 E1/12
E1/4
E1/19 E1/27 E1/35 E1/27 E1/35 E1/43
E1/11

E1/6
E1/6 E1/6
E1/5 E1/6
E1/5 E1/6
E1/6 E1/5 E1/6 E1/6 E1/5 E1/5 E1/5 E1/5 E1/6
E1/6 E1/5 E1/6 E1/5 E1/6 E1/5 E1/5 E1/5

N5K1 N5K2 N5K3 N5K4 N5K5 N5K6 N5K7 N5K8 N5K9 N5K10 N5K11 N5K12

www.INE.com
KEY

Layer 2 Ports
Layer 3 Ports

Rack 1 Server1 Server5 Rack 3 Server9


Rack 5
Server2 Server6 Server10

Ten0 Ten1 Ten0 Ten1 Ten1


Ten0

E1/1 E1/1 E1/1


E1/2 E1/2 E1/2
VLAN 169 VLAN 169 VLAN 169
169.254.0.X/24 169.254.0.X/24 169.254.0.X/24
E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4 E1/3 - 4
N5K1 N5K2 N5K5 N5K6 N5K9 N5K10
10.1.3.0/24 10.3.3.0/24 10.5.3.0/24
E1/5 E1/6 E1/5 E1/6 E1/5 E1/6 E1/5 E1/6 E1/6 E1/5
E1/5 E1/6

10.1.2.0/24 10.3.2.0/24 10.5.2.0/24

E1/3 E1/4 E1/4 E1/19 E1/20 E1/19 E1/20 E1/35


E1/3 E1/36 E1/35 E1/36
10.1.1.0/24 10.3.1.0/24 10.5.1.0/24

N7K1 N7K2 N7K5 N7K6 N7K9 N7K10

E1/7 E1/7 E1/23 E1/39


E1/23 E1/39

ACI ACI ACI

E1/15 E1/15 E1/31 E1/31 E1/47 E1/47

N7K3 N7K4 N7K7 N7K8 N7K11 N7K12


10.4.1.0/24
10.2.1.0/24 10.6.1.0/24
E1/12 E1/11 E1/28 E1/27 E1/44 E1/43
E1/12 E1/28
E1/11 E1/27 E1/43 E1/44
10.4.2.0/24
10.2.2.0/24 10.6.2.0/24

E1/6 E1/5 E1/6 E1/6 E1/5 E1/6 E1/6 E1/5


E1/5 E1/5 E1/5 E1/6
10.4.3.0/24
10.2.3.0/24 10.6.3.0/24
N5K3 E1/3 - 4 E1/3 - 4 N5K4 N5K7 E1/3 - 4 E1/3 - 4 N5K8 N5K11 E1/3 - 4
N5K12
E1/3 - 4
VLAN 169 VLAN 169 VLAN 169
169.254.0.X/24 E1/8 169.254.0.X/24
169.254.0.X/24
E1/1 E1/1 E1/2 E1/1

E1/2 E1/2

Ten0 Ten1 Ten0 Ten1 Ten1


Ten0

Rack 2 Server3 Server7 Rack 4 Server11


Rack 6
Server4 Server8 Server12

INE s CCIE Data Center v2


OTV Diagram www.INE.com
© INE Inc.
INE s CCIE Data Center v2
Nexus Wiring Diagram
© INE Inc.
Rack 1 C200-1

Ten0 Ten1

E101/1/1
Server1 Server2 E102/1/1

N2K3 N2K4
Ten0 Ten1 Ten0 Ten1

E1/1 E1/1
E1/2
E1/2
E1/21 - 22 E1/23 - 24 E1/21 - 22 E1/23 - 24

E1/3 - 4 E1/3 - 4
N5K1 N5K2

E1/5 E1/6 E1/5 E1/6

E1/3 E1/4 E1/4


E1/3

E1/1 - 2 E1/1 - 2
N7K1 N7K2

E1/6 E1/5
E1/5 E1/6

To Rack 2 To Rack 2 www.INE.com


INE s CCIE Data Center v2
To Rack 1 To Rack 1 Nexus Wiring Diagram
© INE Inc.
E1/13
E1/14 E1/13 E1/14

N7K3 N7K4
E1/9 - 10 E1/9 - 10

E1/12 E1/11
E1/12
E1/11

E1/6 E1/5 E1/6


E1/5

N5K3 E1/3 - 4 E1/3 - 4 N5K4

E1/21 - 22 E1/1 E1/23 - 24 E1/21 - 22 E1/23 - 24


E1/1
E1/2
E1/2

Ten0 Ten1 Ten0 Ten1


N2K3 N2K4

E101/1/1 E102/1/1
Server3 Server4

Ten0 Ten1

Rack 2 C200-1

www.INE.com
INE s CCIE Data Center v2
Nexus Wiring Diagram
© INE Inc.

C200-2
Rack 3

Ten0 Ten1

E101/1/1
Server5 Server6 E102/1/1

N2K5 N2K6
Ten0 Ten1 Ten0 Ten1

E1/1 E1/1
E1/2
E1/21 - 22 E1/2 E1/23 - 24 E1/21 - 22 E1/23 - 24

E1/3 - 4 E1/3 - 4
N5K5 N5K6

E1/5 E1/6 E1/5 E1/6

E1/19 E1/20 E1/19 E1/20

E1/17 - 18 E1/17 - 18
N7K5 N7K6

E1/22
E1/21
E1/21 E1/22

www.INE.com
To Rack 4 To Rack 4
INE s CCIE Data Center v2
Nexus Wiring Diagram
To Rack 3 To Rack 3 © INE Inc.

E1/29 E1/30
E1/30 E1/29

N7K7 N7K8
E1/25 - 26 E1/25 - 26

E1/28 E1/27
E1/27 E1/28

E1/6 E1/5 E1/6


E1/5

N5K7 E1/3 - 4 E1/3 - 4 N5K8

E1/21 - 22 E1/1 E1/23 - 24 E1/21 - 22 E1/23 - 24


E1/1
E1/2
E1/2

Ten0 Ten1 Ten0 Ten1


N2K5 N2K6

E101/1/1 E102/1/1
Server7 Server8

Ten0 Ten1

Rack 4
C200-2
www.INE.com
INE s CCIE Data Center v2
Nexus Wiring Diagram
© INE Inc.

C200-3
Rack 5

Ten0 Ten1

E101/1/1
Server9 Server10 E102/1/1

N2K7 N2K8
Ten0 Ten1 Ten0 Ten1

E1/1 E1/1
E1/2
E1/21 - 22 E1/2 E1/23 - 24 E1/21 - 22 E1/23 - 24

N5K9 E1/3 - 4 E1/3 - 4 N5K10

E1/5 E1/6 E1/5 E1/6

E1/35 E1/36 E1/35 E1/36

E1/33-34 E1/33-34
N7K9 N7K10

E1/38
E1/37
E1/37 E1/38

www.INE.com
To Rack 6 To Rack 6
INE s CCIE Data Center v2
To Rack 5 To Rack 5 Nexus Wiring Diagram
© INE Inc.

E1/45 E1/46
E1/46 E1/45

N7K11 N7K12
E1/41 - 42 E1/41 - 42

E1/44 E1/43
E1/43 E1/44

E1/6 E1/5 E1/6


E1/5

N5K11 E1/3 - 4
N5K12
E1/3 - 4

E1/21 - 22 E1/1 E1/23 - 24 E1/21 - 22 E1/23 - 24


E1/1
E1/2
E1/2

Ten0 Ten1 Ten0 Ten1


N2K7 N2K8

E101/1/1 E102/1/1
Server11 Server12

Ten0 Ten1

Rack 6
C200-3
www.INE.com

You might also like