You are on page 1of 3

LOAD CELL WITH - GEFRAN CIR

LOAD CELL TYPE E+L 30 kg/66 Lb


CIR
PIN Color
C Red Supply 24Vdc 51610.
D Black Supply 0Vdc 51611.
A White Signal Out 0/10Vdc 55x05 (Example: 10kg or 22Lb = 3,3Vdc ).
B Blue Signal Out 0Vdc 55x06.

Wire LOAD
CIR
number CELL
Red 55x01 Yellow Signal Out 0/20mVdc (Example: 10kg or 22Lb = 4,5mVdc).
Yellow 55x02 Brown Signal Out 0mVdc.
Green 55x03 Green Supply 0Vdc.
White 55x04 White Supply 10Vdc (8,85Vdc).

CALIBRATION PROCEDURE
Trimmer Action
Empty cell Adjust the trimmer until you have a slightly positive signal between
ZERO
no load the wires 55x05(+) e 55x06(-).
Hang the
Adyust the trimmer until the dispay on the winder show the value
SPAN reference
of the reference weight.
weight
With the
CHECK Verify the correct value on the winder touch with one load cell at a
reference
TEST time.
weight
CHECK Empty load Check if you have the initial value, slightly positive between the
TEST cell no weight wires 55x05(+) and the 55x06(-) if negative or too positive repeat
the calibration.

You might also like