You are on page 1of 1

Catchment Area A = 1904 m2

Rainfall Intensity I = 142.4 mm


Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.18 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 0.9 m
Height inclusion of Free board = 1.1 m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Area of cross sectio of Drain/C A = 0.99
Wetted Perimeter P = 2.5
Radius R = 0.396
Dishcarge through Drain/Culve Q = (1/N)xAxR2/3xS1/2
= 0.21 m3/s
Hence the section of size may be provi 0.9 x 1.1 m

Structural Design
Thickness of walls considered = 0.2 m
Thickness of bottom slab considered = 0.15 m
Thickness of top slab = 0m
Length considered for the design = 197 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 18 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

You might also like