NAPID QA/QC E & I QUESTIONATRES -RE-QUALIFICATION TEST FOR EF. & | QUALITY CONTROL INSPECTOR Name: ate Score: 1. Which standard refer tothe installation ofeable tray and supports loca a. NEMA VE-1 b. NEMA VE2 NEMA 250 a. None ofthe listed above 2, During testing of Low voltage cables with insulation rating of 600V, 450/750V oF {600/1000 Volts AC, How much DC voltage to be applied to check the insulation? a. 500 Vde_ b. SKVde ©. 250 Vde 4 1000 Vde 3. What isthe maximum bends of Rigid Metal Conduit per NEC-2005 requirements? Two (2) quarter bends or 180 deg. b. Three (3) quarter hends or 270 deg ©. Four(4) quarter bends or 360 deg, 4. Five (5) quarter bends of 450 deg. 4. For below ground connections to grounding grids or rods, which of Method is corect. e following By thermite welding or brazing. b. Byaapproved compression grounding connectors ‘c. Forconnection at ground test station by approved mechanical connectors 4d. Allo the above. Fences constructed with concrete posts and PY coated fencing material are not Required to be grounded. a. Tae b. False 6. Which ofthe following electrical equipments is allowed to install in outdoor location? and non air-condition location? ‘a. Manual Transfer Switch (MTS) 'b. Automatic Transfer Switeh (ATS) © Control gear Adjustable Frequency Drives. 7. Boxes and conduit bodies shall be installed so that the wiring contained in them ean be rendered accessible without removing any part ofthe building, a True b. False ‘8, What i the uit of lighting ouput illuminance? ‘a. Foot candle b, Lux Allofthe above 9. Where the LV pane! board is supplied through a transformer, where should he the location of the overcurrent protection required of NEC 2005, a At the secondary side of the transformer, . Atthe primary side ofthe transformer. No overcurrent protection is required, 4 None of the listed above. 10. What isthe maximum length requited for nonmetallic flexible conduit to used as a ‘ap conductor for lighting installation a 3meters b. 18meters ©. 0.5 meters 4 Tmeter 11, Choose the correct installation of motor controller disconnect switches, ‘2. Shall be located insight from the controller. ’. Shall be located in anyplace as long as the disconnect switch installed properly ‘©. Forover 600 Volts or nominal it can be installed out of sight as long as the Disconnect switches can be locked in open position. 4. Botha &e 12, Which ofthe following statement is correct to allow the conduit at top entry? Top entry is allowable provided a drain seal is installed on the conduit within 18" of the enclosure. ‘Top entry is allowable in any method as long as the conduit is properly supported. Top entry is allowable without drain seal installed on the conduit. 4. None of the statement above. 13, Which ofthe following statement is not correct? In severe corrosive environments, cable glands shall be protected against corrosion, '. Allconnections and entries shall comply with the electical area cls ©. Low point conduit drains shall be provided. 4. None of the statement above. 114, Which article in the latest edition of National Electrical Code (NEC) refers the grounding and bonding? & Article 110 b. Article 340, & Amicle 250 4d. Axticle 240 15. Which chapter ofthe latest edition of National Electrical Code (NEC) refers the wiring? Methods and Materials? Chapter 1 ‘b. Chapter 2 Chapter 3 Chapter 4 16, Monty the area tht the ground fault circuit interrupter (GFCD protection is required, a In laundry or utility sink 1b. Bathrooms «. Portable hand tools atthe construction ste (drill machine, cutting machine. ec) 4. Allof the mentioned above, 17, Which statement is correct under space in enclosures? Cabinet and cutout boxes shall have sufficient space to accommodate all conductors installed in them without crowding, »._ Spacing within cutout boxes and cabinets isnot required ©. Spacing with in cutout boxes is only required for High voltage AC cable termination, 4. None of te statement above. 18, For installation of armored cables, which application is not permitted by National Electrical Code (NEC-2005, Art. 320.10). ‘a. In both exposed and concealed work b, Incable way Indry locations, 44. Indamp or wet locations. 19, Type AC eables Per NEC-2005, Art, 32030 shall be secured with in the flowing, 300mm (12 inch) ‘400mm (16 inch) 500mm (0.5 Meter) 4. 1000mm (1 Meter) 20. Does the single core cable penetrate in individual hole in ferromagnetic enclosures ‘has no inductive heating effect?” a Tre b. False 21, Boundary Seal of Class | locations of NEC-2005 art 511.4 is permitted within, atk bst cat 4 on 222, What isthe standard length of Rigid Metal Conduit (RMC or IMC) NEC-2005, including the attached coupling. ‘2.40 Meters b. 3.05 Meters e. Imeter 2.50 Meters 23. Which one ofthe following value is unacceptable voltage drop of AC cables per the Per the latest edition of National Electieal Code 2. More than 5.0 % b. Less than 1.0% © Less than 3.0% d._Allof the above. 24, Choose the following items the insulation color code of grounding cables; a. Green b. Black © Green with yellow stripes d. Botha&e 25, Which ofthe following statement is correct forthe grounding conductor used as a grid equipment or bonding; Be soft or annealed copper. If larger than 35 mm.sq. (#2 awg) be stranded. ‘exposed above grade ina severe corrosion area be insulated All ofthe above 26. A conduit outlet box (GUAT) shall be installed with ‘12° from the instrument devices. . 18" from the instrument devices 6" from the instrument devices 4d. Tmeter 27, Which of the following statement is correct for the use of flexible conduit at the instrument end? ‘8. To provide isolation forthe vibration b, To protect against thermal expansion of rigid conduit ‘c. Easy for maintenance 4. Allofthe above 28. For Instrument cable signal segregation & separation. What is the minimum distance ‘when it comes to tray spacing between Level | & Level 2 ‘2. 100mm 650mm © 150mm 200mm 29. What isthe two types of grounding methods for instrumentation system? 30. Enclosures of instrument device operates less SOVDC shall be grounded conn enclosure directly to the grid using: ‘a. 4mm? Grounding conductor . 16mm? Grounding conductor ‘conductar 4. 35mm2 Grounding conductor

You might also like