You are on page 1of 2

LAGOON DESIGN

Manning formula for flow velocity in pipe


V = 1/n * Rh^(2/3) * S^(1/2)
A = 1/4 p D^2
P=pD
Rh = A/P
S= 0.01 slope
n= 0.01 PVC
Q = AV * no's (from 2 location)
Evaporation rate 3.88 mm/day (lowest in December as per DBM)

OPTION Pipe Dia (mm) no's A (m2) P (m) Rh (m) V (m/s) Q (m3/s)
1 100 2 0.00785 0.314 0.025 0.85 0.004
2 200 2 0.0314 0.628 0.05 1.36 0.085
3 300 2 0.07065 0.942 0.075 1.78 0.251
4 400 2 0.1256 1.256 0.1 2.15 0.541
5 500 2 0.19625 1.57 0.125 2.50 0.981
Q (m3/day) Area required (m2) Length/Width (m)
302.40 77938.1 279.17
7364.11 1897965.6 1377.67
21711.85 5595836.6 2365.55
46759.16 12051330.2 3471.50
84780.00 21850515.5 4674.45

You might also like