the use of the building such as: residential, industrial, office, educational, welfare, sports. The use will define the variable loads that in turn defines the thickness of the slabs. This is expressed in the COVENIN standards, where it says: minimum actions for the building project. Residential building Variable Load The variable load of the roof slab is different from that of the mezzanine slab. The roof has a load of 100 k / m2 because nobody is going to transit it. While the mezzanine is 175 k / m2. Permanent loads The permanent loads correspond to the Partition, the own weight ... see more ... The square root of this value is taken to obtain two numbers that multiplied in this area that gives us 13 cm The minimum area that this column would need to have is 13 cm x 13 cm. There is a norm that says that no column can have an area smaller than 900 k / m2 that is 30 cm x 30 cm. The area of this column would then be 30 cm x 30 cm. To calculate the area of some column of the lower floor than the previous one, the total load of the reinforced slab is multiplied by 2: 1418 k / m2 and the other procedures are continued. The load capacity of the columns of the upper floors far exceeds the value of the total weight that the columns are supporting, for this reason in the pre- dimensioning of the structure we can reduce the area of the columns that are indicated in BLUE color (graphic 1) at 0.30 mx 0.30 m, since the area.