Pt A, Ch 2, Sec 9

k) confirmation that the fire fighters' outfits, including their • general examination of the electrical cabling
self-contained compressed air breathing apparatus, as
well as two-way portable communication apparatus and • functional testing of the main and alternative two-way
emergency breathing masks are complete and in good communication system at the lifting operating position
condition and that the cylinders, including the spare • verification of the structural arrangement and founda-
ones, of any required self-contained breathing apparatus tions of the lifting equipment
are suitably charged
• testing of hydraulic installations
l) confirmation that doors located in bulkheads forming
boundaries with the adjacent spaces are in a satisfactory • load tests in accordance with the rules or requirements
condition referred to in the lifting equipment certificate.
m) general examination of the visible parts of items forming
the structural fire protection, such as bulkheads, decks, 10.3 Class renewal survey
doors and trunks, due attention being given to their
integrity and the integrity of the insulating material.
10.3.1 The requirements given in Rule Notes NR526 and
NR595 are applicable for renewal survey.
8.2 Class renewal survey
In addition, load tests in accordance with the rules or
8.2.1 In addition to the requirements for annual survey, the requirements referred to in the lifting equipment certificate
class renewal survey of the spaces containing the diving are to be carried out.
system is to include:
a) for breathing gas installations, testing of the gas-tight-
11 Survey of additional class notation
ness of all sealing devices of the enclosed spaces for
breathing gas storage HEL
b) functional testing of self-closing systems of doors
located in bulkheads forming boundaries with the adja- 11.1 Application
cent spaces
c) verification of accuracy of oxygen-measuring equip- 11.1.1 The requirements of this Article apply to ships
ment by means of calibration gas, as far as practicable which have been assigned the additional class notation HEL
defined in Ch 1, Sec 2, [8.4].
d) verification of the sea inlet protective structure, as relevant.

9 Survey of additional class notation 11.2 Annual survey


OHS
11.2.1 The Society considers that as a minimum these fol-
9.1 Periodical surveys lowing issues are to be examined during the periodic sur-
veys to confirm that there has been no alteration or
9.1.1 Requirements regarding periodical surveys, lay-up deterioration in the condition of the helicopter landing area:
and re-commissioning surveys, are given in Section 4 of
NR595 Classification of Offshore Handling Systems. a) The general examination of the physical characteristics
of the helideck is to include:

10 Survey of service notation Lifting • the dimensions as measured


• the declared D-value
10.1 General
• the deck shape, and
10.1.1 The requirements of this Article are additional to
• the scale drawings of deck arrangement.
those laid down in NR526 Rules for the Certification of Lift-
ing Appliances onboard Ships and Offshore Units or NR595 b) The general examination of the preservation of obstacle-
Classification of Offshore Handling Systems, whichever is protected surfaces is to include:
applicable.
• the minimum 210° Obstacle Free Sector (OFS) sur-
face
10.2 Annual survey
• the 150° Limited Obstacle Sector (LOS) surface, and
10.2.1 The survey is to include verification and testing of
• the minimum 180° falling 5:1 gradient surface with
the lifting equipment, as follows:
respect to significant obstacles.
• verification of the presence onboard of the following
documents: Note 1: If one or more of these surfaces is infringed due, for exam-
ple, to the proximity of an adjacent installation or vessel, an
- technical manual assessment is to be made to determine any possible negative
- planned maintenance system effect which may lead to operating restrictions.

December 2016 Bureau Veritas - Rules for Offshore Units 109