Professional Documents
Culture Documents
1. SCOPE OF APPLICATION:
The specific gravity of 1.053 is equivalent to 12.5 g/dl haemoglobin. CuSO4 solution of
specific gravity 1.053 is used for pre donation haemoglobin test.
2. RESPONSIBLITY:
The laboratory technician is responsible for preparation of CuSO4 solution for Hb
Estimation for determining suitability of donor for blood donation.
4. PROCEDURE:
Prepared By Approved By
1. Label the preparation flask with identity and date of preparation e.g. Stock
CuSO4 sol. Matching with Hb conc. of 12.5 gm%
2. Carefully weigh 159.63 gms of pure air dried crystals of CuSO4 5H2O
3. Tip the crystal into the preparation vessel and add 80% of the total volume of
copper sulphate solution.
4. Cap the vessel and mix well to ensure that it has dissolved completely.
5. Add the remaining volume of distilled water to give the correct total volume of
copper sulphate solution.
6. Recap the vessel and mix well.
7. Using a hydrometer check the specific gravity of solution. Reading should be
within 1100. If it is not within this recheck the reading. If still not correct inform
some senior member of staff.
8. If reading is correct proceed further, tightly cap the container and keep it in a
moisture free place.
9. Thoroughly clean all the reusable glassware and equipment.
Prepared By Approved By
4. Keep them at room temp. and ensure that all the bottles are labelled correctly and
there is no leak.
5. Complete the preparation record, detailing the data dispensed and number or
bottles prepared
6. Thoroughly clean all reusable glassware or equipment used.
Quality control:
Routine QC should be performed on each batch of CuSO4 solution prepared, before it
is released for use.
One bottle for each 20 bottles prepared upto a max. of 10 bottles should be set aside
for QC check.
QC Check:
1. Hold each bottle upto the light and check for cloudiness or the presence or
precipitate. If it is not completely clean it must not be used.
2. Using a hydrometer recheck that the Sp gravity is within the required range. lf it is
not so, repeat the reading, if it is still out of range do not use it and a senior
member of staff should be informed.
3. If batch passes the above checks, it can be released for use.
5. DOCUMENTATION:
Enter all details in the registers.
6. REFERENCES:
i. Technical Manual, 11th ed., American Associating of Blood Banks, 1993.
ii. Technical Manual, 15th ed., American Associating of Blood Banks, 2005.
iii. Donor room policies and procedures ........... AABB publication.
7. END OF DOCUMENT
Prepared By Approved By