COATING SYSTEM - SHOP PAINTED - STRUCTURAL STEEL AND PIPING APPLICATION: EXTERIOR STRUCTURES PROCEDURE: 1 ALL SURFACES TO BE COATED SHALL BE CLEAN, DRY AND FREE FROM CONTAMINATION. PRIOR TO PAINT ‘APPLICATION, ALL SURFACES SHALL BE ASSESSED AND TREATED IN ACCORDANCE WITH ISO 8504:2000. (Ol. OR GREASE SHALL BE REMOVED IN ACCORDANCE WITH $SPC-SPI SOLVENT CLEANING. ABRASIVE BLAST CLEAN TO STANDARD SSPC-$P6. IF OXIDATION HAS OCCURRED BETWEEN BLASTING AND APPLICATION, THE SURFACE SHOULD BE RESLASTED TO THE SPECIHED VISUAL STANDARD. SURFACE DEFECTS REVEALED BY THE BLAST CLEANING PROCESS SHALL 8 GROUND, FILLED OR TREATED IN THE APPROPRIATE MANNE THE PREPARED SURFACE SHALL HAVE A SHARP ANGULAR PROFILE OF 2-MILS (50-75 MICRONS} IDEALLY, THE SURFACE MUST BE PRIMED WITHIN 4 HOURS OF COMMENCEMENT OF PREPARATION, A STRIPE COAT SHALL DS, LAP JOINTS, PLATE EDGES, CORNERS, SHARP. ANY OTHER AREAS WHERE SPRAY APPLICATION OF THE OVERALL COATING SYSTEM MAY PROVE DIFFICULT, RESULTING IN LOW DRY FILM THICKNESS’ FOR DETAILED PRODUCT INFORMATION, REFER TO INTERNATIONAL'S PRODUCT DATA SHEETS. COATING SYSTEM - SHOP PAINTED- STRUCTURAL STEEL & PIPING: PRODUCT INFORMATION COLOUR: VANCOUVER WHARVES BLUE: FEDERAL STANDARD 15187 SURFACE PREPARATION: ——SSPC- SPI SURFACE PREPARATION: SSPC- $P6 PRIMER: CATHACOAT 313 3+ S MILS DFT STRIPE COAT: BAR-RUST 235 oF 236 2-3 MILS DFT MID COAT: BAR-RUST 235 oF 236 6-8 MILs DFT FINISH COAT: BAR-RUST 235 oF 236 6-8 MILS DFT MIN. TOTAL DFT: 15 MILs kw 2012 cuTomuL | 5 May 2014 MORGAN 7 src: ‘CANADA TERMINALS ULC | TECHNICAL SPECIFICATION [SHOP PAINT EXTERIOR STRUCTURES ["" 1 OF 1