Advanced Power Supplier

HF online UPS Digital Series: 6-20KVA


N+X parallel redundancy Max: 60KVA
LCD /LED display

I S O 9 0 0 1:2008
ISO14001:2004
Advanced Power Supplier

Digital Series UPS D6K(S) -3D20KS parallel redundancy adopts double conversion true on-line structure,

which can avoid the loading strike from abnormal power and can ensure the output stabilization and

reliability. It adopts digital control technology to achieve parallel redundancy function.

High Reliable Parallel Technology


With the devices expansion, it needs relevant electric
power expansion, so just need to purchase the UPS
for the expansion and parallel it to the original power
system, which reduces the investment waste largely.

N+1 parallel redundant function


N+1 parallel redundant function means that there is
always a UPS for your important equipment to
provide protection. When Power system planning,
there is an additional UPS more than the rated
capacity, so that when any one UPS of the system
fails, the additional one will make power system
c a pa b l e of u n i n t e r r u p t e d f o r y o u r i m p o r t a n t Load 1 Load 2 Load 3
equipment to provide high-quality power, which Early stage Second phase Third phase
extension extension
makes the system more reliable, and advanced
technology makes ever y UPS parallel operation under
average share the load current, to improve the
Sketch of parallel expansion
reliability of the system at the same time also
extended the ser vice life of the ups

Miniaturization

Advanced control technology improves the power


factor, which makes the UPS with compact size and
light weight.

On-Line maintenance
LOAD LOAD
If you have the optional maintenance switch, just
need to transfer the UPS to repair mode, you can
repair the UPS on- line safely, when UPS is providing
the uninterrupted electric power to the loads; With
N+1 parallel redundancy function, even if the utility
is interrupted when the UPS is under the repair, your
valuable devices still can get the high quality power
supply.
Sketch of parallel redundant
Parallel Redundant N+X Max: 60KVA

Finance Industr y Electric Power

Free for monitor software UPSILON2000


Bond IDC Transportation

Complete Function
DC Startup function let you still use UPS when main fails. Timing startup and shutdown, remote monitor functions
realize unmanned purpose. Strong charging capability is convenient to extend the backup time. Intelligent
charging management mode prolongs the batter y life to save expense. Automatic restart function can start UPS
automatically after batter y discharged fully. Complete function design brings more convenience for your work.

Excellent technology performance


Nearly' 1 'power factor reduces the pollution for the main environment and improves the main using efficiency,
which is true green power.
Wide input voltage range can provide perfect protection to your important devices in various bad electric power
environments.
Over 93% operation efficiency with full load saves the electricity fee.
Strong anti-jamming resistance complies with IEC61000-4 EMI approvals, which provides your device with a clear
electric power environment.
Other each outstanding technical specification makes you enjoy the upscale brand at economical price.

Intelligent monitor software


Support Microsoft, Windows95/98/Me/NT/2000/XP/Linux operation systems and is fit for TCP/IP LAN, and support
TCP/IP network monitor UPS; Provides lamination table of contents structure management network UPS, unusual
event notice; Detects the UPS model and the communication interface automatically; Provides the password
protection; Supports fixed time opens/closes UPS; Supports UPS fixed time to test oneself ; Support graph to
display UPS condition; Supports network closure ser ver and workstation; Supports close the majority of application
procedure and the preser ved related documents; Supports the simplified/traditional Chinese; Supports multi-
national languages and English platform; Supports on-line assistance function. With the data record (including
experiment site, UPS, load, batter y) and the event journal function, it is convenient for the system manager to carr y
on the UPS routine maintenance.

Perfect monitor communication function


It provides RS232, intelligent slot etc monitor communication interface. Users can realize focus or remote monitor
etc functions through SNMP network card.
Specifications

Model D6K D6KS D10K D10KS 3D10KS 3D15KS 3D20KS


Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW

Phase single phase three phase

Input Voltage 120VAC ~ 275VAC 304VAC ~ 478VAC

Frequency 50/60Hz±10%
Voltage 220/230±1%VAC
Same with input (utility mode)
Output Frequency
50/60Hz±0.5 ( battery mode )

Crest Ratio 3:1(max)


Output waveform Pure sinewave

Transfer time Zero

Backup time(full/half load) 4 ~ 7′/12 ~ 20 ′ -- 3 ~ 5′/10 ~ 13′ --

DC voltage -- 192/240VDC -- 192/240VDC

Battery type Free maintenance valve regulated lead-acid battery


bypass after 1min, 125%~135% output switch to bypass after 30 seconds,
Overload capacity 105%~125% output switch toover 135% output switch to bypass after 100ms
Linear load <3%
Distortion
(full load)
Non-linear load <5%

Communication interface Rs232 interface + Intelligent slot

working temperature 0℃ ~ 40℃

Relative humidity 20~90%(non-condensing)

( 192VDC )
Dimension 515x250x616 515x240x460 515x250x616 515x240x460 515x250x616
(D x W x H)(mm)
570x260x717(240VDC)

192VDC

56 18.5 61 20 27 35 35.5
Net Weight(Kg)
240VDC

90 35 93 38 39 55 55

Remark: 1. 'S' means long backup model. Meet International EMC standards
2. Customizable output PF=0.9.

High altitude area load=Rated power×Coefficient of reduction

Altitude( m ) 1000 1500 2000 2500 3000 3500 4000 4500 5000

Coefficient of reduction 100% 95% 91% 86% 82% 78% 74% 70% 67%

If UPS is used in elevation above 1000m, it is necessar y to use the declining rating output, the drop coefficient is above the table.

※The above parameters can be adjusted and changed, please prevail in kind.