You are on page 1of 3
att EFTY POWER SYSTEMS CORPORATIO Request for Quotation Company: Bauer Foundations Philippines From: HEFTY POWER SYSTEMS CORPORATION Attention: Ws. Jazreel Estipular Tel.#: (02) 759-9511 ToliMobile #: Mobilett: 0917 306 2955 EmaliAd: —_estipular@bauernetioh Email: _kysmendoza@heftypower.com.ph Project: ‘Nabas-Caticlan-Boracay TL Project Contact Person: Kyle S. Mendoza nae Description ty. | unit Unit Price ‘Total Price [Bored Pile Foundations (see atta details) sched file for more Grand Total Price Toi Nox (02) 293° "Ema nfo Fey (on) 376 2055 | (02) 75 lefypowercom-ph NABAS-CATICLAN-BORACAY TRANSMISSION LINE PROJECT (138 KV / 230 KV OVERHEAD TRANSMISSION LINE PORTION) ‘Sp19.NCBOHTL.Vt-0414 SCHEDULE OF BORED PILE FOUNDATION TOWERIPOLE NO. BURIED DEPTH | EXPOSED DEPTH (As per etructure sty | TOWERTYPE | DIAMETER (D) | TOTAL DEPTH (Hd (H) REMARKS. NC-01 DraDua 200 20.007 19.00 1.00 NC-03. DiTaten5-21-230 2.50 20.00 19.00 7.00 NC-04 Ds4 4.80 17.00) 15,50. 1.50 NC-08 Da4/DR4 1.60 78.00. 16.50 1.50) NC-09 Diraten5-21-230 2.00 720.00. 18.50 1.50 NC-10- DQ4/DR4 1.60, 19.00, 17.50. 7.50 NC=12 DTTaten5-21-230 2.00 21.00 19.50. 1.50, NC-13 DQ4/DR4 1.60. 18.00. 16.50. 1.50 NC-15 DQ4/DR4 7.60. 17.00) 15.50. 7.50 NC-19 DiTatens-Z1-230 2.50 22.00 21.00 7.007 NC-21 Draten30-Z1-230 2.50. 20.00. 18.00 2.00 with te beam, Note: All dimensions indicated above are for bidder's reference only in their bid price proposal. Final dimension shall be based on the approved design of the bidder. SECTION A-A RTS NOTES : ‘ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAY PERIOD, fe = 211 kg/cm? (3,000 PSI). REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF PNS 49:2002, DEFORMED STEEL BARS GRADE 414 (FY = 60 KSI). ALL ASPECTS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST ACI CODE. DETAILS OF REINFORCING BARS SHALL CONFORM TO LATEST ACI CODE. USE BUNDLE BARS IF CLEAR SPACING OF REINFORCING BARS IS LESS THAN 70 MM (MAXIMUM OF FOUR BARS PER BUNDLE). SPLICING OF BARS SHALL BE STAGGERED WITH LENGTH OF SPLICING NOT LESS THAN 40 x MAIN BAR DIAMETER. PROVIDE 5 EXTRA 12 mm DIA TIE AT THE TOP OF THE CASE, SPACED AT 50 mm 0.C. NO_SEPARATE PAYMENT WILL BE MADE FOR METAL SUPPORTS, SPLICING/ OVERLAPPING, WASTAGE, TIES, HOOKS, CHAIR, WIRE TIES AND ALL OTHER APPROVED SUPPORTS TO INSTALL AND SECURE REINFORCING BARS PROPERLY. ef ‘BORED PILE ELEVATION mea xevian, STEEL TOWER FOUNDATION TYPICAL BORED PILE DRAWING "ELEVATION AND SECTION

You might also like