You are on page 1of 6
@ . nyquist ingenieria Distribution Voltage Regulators Single Phase 2.5 to 19.9 kV Three Phase 13.2 to 34.5 kV Power Transmission & Distribution SIEMENS Single Phase Voltage Regulator & . nyquist ingenieria Electrostatically applied polyester paint gives greater resistance to corrosion in harsh environments. is standard on all JFR regulators. No rust. — Type 316 stainless steel external hardware No galling. Sealed tank with pressure relief device to vent gases produced during tap changes. With the 65°C insulation system, Siemens 55°C rise regulators can be loaded up to 12 percent above nameplate rating. EMME External MOV bypass arrester gives a superior protection tothe regulator series nyquis ingenierla winding from surge and system transients, il sight gauge allows oil levels and oil conditions to be checked without de. energizing the regulator. WEEE Motor capacitor installed in the control cabinet allows replacement without bypassing and taking the regulator out of service Polarized disconnect switch (PDS) facilitates easy control installation or change out without taking the regulator out of service. Cover mounted terminal block provides easier access to wiring by eliminating the need to go under oll to change tap connections. u Monitor and automatically control output voltage through the use of state-of-the-art microprocessor control panels MJ-4A & MJ-48, High creep bushings provide a minimum creep distance of 17 inches, HERI il drain valve that includes an oil sampling valve for easy access. BEER platform base is equipped with provisions to securely attach regulator to sub-base assembly. f . nyquist ingenieria Modification Capabilities External Modifications Accessories = Line Terminals = Remote Mounting Cables (15°50) Special Ground PadsiConnectors Substation Bases = Lowered Control Enclosure = Lightning Arrester Special Ultra-Creep Bushings Bird Guards = Thermometers or Fans (if possible) * Auxiliary Potential Transformer Special Drain Valves * Auxiliary Current Transformer = Nameplate Changes/Modifications = Bypass Switches * Paralleling Balancers Internal Modifications Source Side Potential Transformer (Not required with MJ-4A Control) © Special Current Transformers MJ-4A™ Voltage Regulator Control Panel AN f& . nyquist ingenieria @ . nyquist ingenierla The MJ-4A & MJ-48 Voltage Regulator ‘Fast path keys for immediate accessibility to the control panels are theultimate featurech most commonly used functions ‘monitoring and data communications tool, designed to save you time and money. The user friendly MIA & M-48 provide Easy-to-use menu structure for panel configuration in three easy steps substantial cost savings to utilities by = Convenient communications capabilites including providing quick, flexible voltage reduction to _—_data port, communication module and remote lower actual demand during peak periods. ‘access va laptop computer or SCADA Customizable Quick Key” allows the creation of a quick ist to the users’ most frequently accessed The powerful 32 bit Microprocessor MJ-4A contol cabinets and include all retrofit & MB control panels can be retrofitted to interface circuits. They'e backed by Siemens all manufacturers’ regulators, eliminating superior technical and field support, costiy and time-consuming replacements. extensive on-site customer training and The control panels mount into existing __ on-going assistance. IRENE Highly Visible LED Display EMI Voltage Select key WERE Local Data Port EMME Counters & Electronic Tap Position Fast-Path Key BEIM Dedicated Fast-Path Function Keys Dedicated Fast-Path Alert Key Voltage Reduction & Voltage Limit MELONI Easy-to-Use Keypad Menu Neutralite™ Test Button Carry Handle WEN Quick Key™ RemotelLocal Key HERE Maintenance Fast-path Key ‘The communication module isthe interfoco used to connect the MI-48 & M148 control ppnels 0 SCADA. The R5232/485 connection Supports 85232 multidrop configurations and [S485 loop, stor and open end configurations ‘The fiber opti ST connections supports @ loop orstar configuration. The communication ‘module can be preinstaed inthe contol nel ar easily retvofitied in the ft

You might also like