You are on page 1of 6

CORRIGENDUM-I

Name of work: “Appointment of Architectural Consultant for Refurbishment, Retrofit & Renovation of the old T-1 Terminal building
at Jaipur Airport”.
Tender ID : 2018_AAI_6683_1

1. Reference may please be made to Tender Document for the above work published through CPP portal on 25.01.2018
2. The following amendments in the above referred tender document bid have been incorporated:

S. Reference Existing Amended


No. (Page No. /
Para No. /
Line No.)
1 Page No. 1 of estimated cost of Rs. 1743.23 Lakh estimated cost of Rs. 3403.00 Lakhs
WNIT, Para-
1.1
2 Page No. 1 of Tender fee of Rs. 3,360/- (Non-refundable) Shall remain same.
WNIT, Para-
1.1
3 Page No. 2 of Should have satisfactory completed Consultancy for Should have satisfactory completed Consultancy for Project of
WNIT, Para- Project of Remodeling/ Refurbishment/Retrofit and Remodeling/ Refurbishment/Retrofit and Renovation of
1.3.2 Renovation of buildings/ heritage Structures along with buildings/ heritage Structures along with associated works with
associated works with total project costing one work not total project costing one work not less than Rs. 27.23 Crores or
less than Rs. 14.40 Crores or two such projects costing two such projects costing not less than Rs. 17.02 Crores during
not less than Rs. 09.00 Crores during last 7 years last 7 years last date (extended date) of submission of bid in
ending 31st December, 2017 India.

CORRIGENDUM – I: Page 1 of 6
S. Reference Existing Amended
No. (Page No. /
Para No. /
Line No.)
4 Page No. 8 of It is proposed to implement the project of It is proposed to implement the project of (Operationalization
Tender (Operationalization of T-01Building at Jaipur Airport), of T-01Building at Jaipur Airport), through the engagement of
Document through the engagement of Architectural Architectural Consultant specializing in refurbishment, retrofit
Para- 2.0 Consultant specializing in refurbishment, retrofit & & Upgradation of public buildings / heritage structures. The
Upgradation of public buildings / heritage structures. Consultant so appointed shall be responsible from concept to
The Consultant so appointed shall be completion stage i.e. Concept design, detailed design &
responsible from concept to completion stage i.e. engineering, bid process management & construction
Concept design, detailed design & engineering, bid management services. The award of work to consultant shall be
process management & construction management by call of open bids (E-Tender route) on the basis of item rate
services. The award of work to consultant shall be by tender document to be finalized by Consultant.
call of open bids (E-Tender route) on the basis of item The Consultant is required to provide comprehensive
rate tender document to be finalized by Consultant. Architectural & Engineering Consultancy services. The
The Consultant is required to provide Architectural & objective is to ensure refurbishment of the old T-1 terminal
Engineering Consultancy services. The objective is to building with local architectural heritage for a sustainable and
ensure refurbishment of the old T-1 terminal building cost effective solution for Operationalization of T-01 Building
with local architectural heritage for a sustainable and at Jaipur Airport.
cost effective solution for Operationalization of T-01
Building at Jaipur Airport.

CORRIGENDUM – I: Page 2 of 6
S. Reference Existing Amended
No. (Page No. /
Para No. /
Line No.)
5 Page No. 9 of The scope of work shall be planning, designing & The scope of work shall be planning, designing & detailing of
Tender detailing of the project which will include layout the project which will include layout planning, preparation of
Document planning, preparation of conceptual plan, perspective conceptual plan, perspective view/artist’s view, Architectural
Para- 2.1 (A) view/artist’s view, Architectural plan, showing plan, showing tentative arrangement of various facilities for
tentative arrangement of various facilities for smooth smooth passenger flow along with City side and Air side
passenger flow along with City side and Air side elevations of a modern energy efficient terminal building
elevations of a modern energy efficient terminal depicting local architecture/ culture/ art/ heritage including
building depicting local services such as Water Supply, Drainage, Sanitary installations,
architecture/culture/art/heritage including services such Internal & External Electrical Installations, modification in
as Water Supply, Drainage, Sanitary installations, existing HVAC system, baggage handling system in
Internal & External Electrical Installations, Media plan, departure & arrival level, provision of DG Set and essential
interior designing and external lighting and other power supply, LT panel, UPS etc., fire alarm & fire-fighting
services etc. and preparation of technical specifications, system, replacement of light fittings, signages (Internal &
detailed estimate, Item rate tender documents and External), drinking water system, PA system, FIDS, CCTV,
assisting AAI in selection of bidder and award of work IT, Telephone wiring & instruments, Media plan, interior
to the Contractor, including site visits, Co-ordination designing and external lighting and other services etc. and
and Clarification etc. during preparation of technical specifications, detailed estimate, Item
execution of works. rate tender documents and assisting AAI in selection of bidder
and award of work to the Contractor, including site visits, Co-
ordination and Clarification etc. during
execution of works.
6 Page No. 11 of c) All the detailed working drawings for Civil, c) All the detailed working drawings for Civil, structural,
Tender structural, plumbing, internal & External plumbing, internal & External Electrification, firefighting
Document Electrification, firefighting system (Hydrants & system (Hydrants &
Para- 2.3.1.4 sprinklers), External lighting and any other systems sprinklers), External lighting and any other systems covered in
covered in the scope of work shall be prepared and the scope of work shall be prepared and certified: “GOOD FOR
certified: “GOOD FOR CONSTRUCTION” and CONSTRUCTION” and submitted with the signature of
submitted with the signature of consultant in each consultant in each drawing. The working drawings shall also
drawing. The working drawings shall also incorporate incorporate the equipment directly engineered by AAI.
the equipment directly engineered by AAI.
Based on the detailed system design, equipment like Smoke
Based on the detailed system design, equipment like detectors and control panel etc., for pipe size & pumps / motors
Smoke detectors and control panel etc., for pipe size & etc. for firefighting system, light fixtures, fans DBs and LT
pumps / motors etc. for firefighting system, light Panels etc. for Internal & External Electrical Installations shall
CORRIGENDUM – I: Page 3 of 6
fixtures, fans DBs and LT Panels etc. for Internal & be selected based on standard items available in the market
External Electrical Installations shall be selected based close to the design value.
on standard items available in the market close to the
design value. d) The Tender Documents, Technical Specification, Rate
Analysis etc. shall be got approved by AAI. In case of any
d) The Tender Documents, Technical Specification, modification, the
Rate Analysis etc. shall be got approved by AAI. In case consultant has to modify the same and resubmit to AAI.
of any modification, the
consultant has to modify the same and resubmit to AAI.
Note: consultant shall use AAI’s standard specifications to the
Note: consultant shall use AAI’s standard specifications extent possible. in respect of the following electrical works:-
to the extent i) Internal Electrical installation.
possible in respect of the following electrical works:- ii) Firefighting and sprinkler system.
i) Internal Electrical installation.
ii) Firefighting and sprinkler system.
e) The consultant shall assist AAI in finalizing the pre-
e) Before opening of tenders the consultant has to qualification criteria and also regarding selection of
submit justification statement covering Analysis of contractor experienced in similar nature of work.
Rates based on prevailing market rates for all the items
of all the packages as per CPWD Analysis of Rates. f) Before opening of tenders the consultant has to submit
justification statement covering Analysis of Rates based on
prevailing market rates for all the items of all the packages as
per CPWD Analysis of Rates.

CORRIGENDUM – I: Page 4 of 6
S. Reference Existing Amended
No. (Page No. /
Para No. /
Line No.)
7 Page No. 24 of Criteria : Should have satisfactory completed Criteria : Should have satisfactory completed Consultancy for
Tender Consultancy for Project of Remodeling/ Project of Remodeling/ Refurbishment/Retrofit and Renovation
Document Refurbishment/Retrofit and Renovation of buildings/ of buildings/ heritage Structures along with associated works
(PQ- heritage Structures along with associated works with with total project costing one work not less than Rs. 27.23
Performa) total project costing one work not less than Rs. 14.40 Crores or two such projects costing not less than Rs. 17.02
Para- 4.1.1 Crores or two such projects costing not less than Rs. Crores during last 7 years last date (extended date) of
09.00 Crores during last 7 years ending 31st December, submission of bid in India.
2017)
8 Page No. 25 of Criteria : Should have satisfactory completed Criteria : Should have satisfactory completed Consultancy for
Tender Consultancy for Project of Remodeling/ Project of Remodeling/ Refurbishment/Retrofit and Renovation
Document Refurbishment/Retrofit and Renovation of buildings/ of buildings/ heritage Structures along with associated works
(PQ- heritage Structures along with associated works with with total project costing one work not less than Rs. 27.23
Performa) total project costing one work not less than Rs. 14.40 Crores or two such projects costing not less than Rs. 17.02
Para- 4.2.1 Crores or two such projects costing not less than Rs. Crores during last 7 years last date (extended date) of
09.00 Crores during last 7 years ending 31st December, submission of bid in India.
2017)

3. The critical data sheet :- (Page No. 3 of WNIT, Para- 1.4)

Existing Revised
Publishing Date 25.01.2018 -
Bid Document Download / Sale Start Date (Next 26.01.2018 from 10.00 hrs. -
Day of Publishing Date)
Clarification Start Date 26.01.2018 from 10.00 Hrs. 14.02.2018 from 10.00 Hrs.
Clarification End Date 31.01.2018 upto 18.00 Hrs. 17.02.2018 upto 18.00 Hrs.
Bid Submission Start Date 05.02.2018 from 10.00 Hrs. 21.02.2018 from 10.00 Hrs.
Bid Submission End Date 10.02.2018 upto 18.00 Hrs. 23.02.2018 upto 18.00 Hrs.
Last date and time of submission of original 15.02.2018 upto 17.00 Hrs. 28.02.2018 upto 17.00 Hrs.
BG/Demand Draft against EMD and Tender Fee,
Signed hard copy of AAI Unconditional Acceptance

CORRIGENDUM – I: Page 5 of 6
Letter.
Bid Opening Date (Envelope- I) 16.02.2018 from 12.00 Hrs. 01.03.2018 from 12.00 Hrs.
Bid Opening Date (Envelope- II) To be intimated later on through CPP Portal No Change

Tender Fee Rs. 3360/- (Rupees Three Thousand Three No change


Hundred and Sixty Only) (i/c GST) in the form
of Demand Draft only, Nonrefundable.
EMD Rs. 5,00,000/- (Rupees Five Lakhs Only) in the No change
form of Demand Draft / FDR/ Bank Guarantee
as per annexure – III, Page No. 34 of NIT.

4. All other terms and conditions shall remain the same.


5. This Corrigendum-I (06 pages) shall form part of the tender document.

(D. Meganathan) (Pankaj Kumar)


Asst. Mgr Engg. (C) Manager Engg.(E)

(Satyendra Singh) (Mukul Mittal)


Sr. Manager Engg. (C) A.G.M Engg. (E)

(S.K.Sagar) (N.B. Goel)


D.G.M. Engg. (C) D.G.M Engg. (E)

(M.N.N. Rao) (Chandra Shekhar)


G.M. Engg. (C) G.M. Engg. (E)
APPROVED

(K. Bhattacharjee)
Executive Director (ENGG)-NR, CHQ

CORRIGENDUM – I: Page 6 of 6