Es100 123 Ise70
Es100 123 Ise70
RoHS
General
For air
It is possible to change the Blue
Sub screen
Label (Display item), Set value (Threshold value)
Visualization of Settings
Set value
(Threshold value)
Hysteresis value
Peak value
Bottom value
Rotating display
After installation, the display can be
Install a switch with 336° rotated to an easy-to-see direction
a wrench.
by securing the body by hand.
Mode Examples
Visualization of Settings Hysteresis mode
Set value Reversed Set value
Normal output
The sub screen (label) shows the item to be set. (Threshold value) output (Threshold value)
UP DOWN UP DOWN
SET SET
Reversed output/ Set value Reversed output/ Set value
Lo side (Threshold value) Hi side (Threshold value)
Always displayed
Switches between displays on one screen
NPN PNP
Label Label
(Peak) Peak value (Bottom) Bottom value Peak value Bottom value
Output mode/Output type display Rated range display Level bar display Pressure unit display
Hysteresis mode Window comparator mode Positive pressure range kPa MPa psi*1 bar*1
1
3-Screen Display High-Precision Digital Pressure Switch ISE7 m/7 mG Series
Convenient Functions
Security code Resolution switch function Applied pressure error
The key-lock function keeps Reduces monitor flickering When the applied pres-
unauthorized persons from
sure exceeds the rated
tampering with the settings.
pressure, the pressure
Power-saving mode application is counted as
Power consumption is reduced an applied pressure error
by tur ning off the monitor. (the maximum number of
(Reduce power consumption
by approx. 60%.)
1/1000 1/100 applied pressure errors The number of applied
(Only the displayed values are changed; the accuracy remains the same.) is 1000 counts). pressure errors
3 Setting Modes
3-Step Setting Mode Simple Setting Mode Function Selection Mode
Select the setting mode that best
meets your needs. Higher
Simple Settings
function
• Output mode selection
• Threshold value setting • Threshold value setting • Selection of normal or reversed
• Threshold value setting
or • Hysteresis value setting
• Hysteresis value setting
• Hysteresis value setting • Delay time selection • Delay time selection
• Display color selection
3 Normal or reversed
output selection
Select from • Normal output
• Reversed output
5 Hysteresis value
setting
• Adjust the numerical value.
IO-Link Compatible
Visualization of operation/equipment status/Remote monitoring and control by communication
Configuration File (IODD File*1)
•Manufacturer •Product part no. •Set value
IO-Link is an open communication
*1 IODD File: interface technology between the
IODD is an abbreviation of IO Device sensor/actuator and the I/O terminal that
Description. This file is necessary for is an international standard, IEC61131-9.
setting the device and connecting it to a
PLC master. Save the IODD file on the PC to
PC be used to set the device prior to use.
Fieldbus
Confirm the pressure condition during
Read the device data. operation and monitor the device status.
Device settings • Switch ON/OFF signal and analog value Monitor the abnormal pressure and the
can be set by the • Device information: abnormal status of a pressure sensor remotely
master. Manufacturer, Product part number, to prevent unexpected stops.
• Threshold value Serial number, etc.
• Operation mode, • Normal or abnormal device status
etc. • Cable breakage
Display function SIO mode Start-up mode Preoperate mode Operate mode
Displays the output
communication status and
indicates the presence of
communication data
Start up
At the start of communication
Preoperate
Yes *1
Version does IO-Link version does not match that of the master.
*2 IO-Link not match The master uses version 1.0.
mode
Abnormal
(Flashing)
Lock Back-up and re-store required due to data storage lock
*1 The COM indicator is ON when communication with the master is established. *2 In IO-Link mode, the IO-Link indicator is ON or flashes. *3 When the sub screen is set to Mode
3
3-Screen Display High-Precision Digital Pressure Switch ISE7 m/7 mG Series
Introduction of Series
ISE70/71 p. 6 ISE70G/75G/76G/77G p. 8
Blue Gray
Applicable
Air General fluids
fluid
10 MPa
5.0 MPa
Rated
pressure
range
2.0 MPa
1.6 MPa
1.0 MPa 1.0 MPa
Withstand
1.5 MPa 2.4 MPa 3.0 MPa 5.0 MPa 12.5 MPa 30 MPa
pressure
Power supply voltage
When used
as a switch 12 to 24 VDC ±10% with 10% voltage ripple or less
output device
When used
as an IO-Link 18 to 30 VDC, including ripple (p-p) 10%
device
Temperature
±2% F.S. (25°C standard) ±3% F.S. (ISE70G)/±5% F.S. (ISE75G/76G/77G)
characteristics
Number of
screens/ 3-screen/2-color display
Display type
Enclosure IP67
Materials of Sensor pressure receiving area: Silicon Sensor pressure receiving area: Al2O3 (Alumina 96%)
parts in Piping port: C3604 Piping port: C3604 (Electroless nickel plating)
contact with (Electroless nickel plating) O-ring: FKM + Grease (ISE70G)
fluid O-ring: HNBR Square ring: FKM (ISE75G/76G/77G)
Note Selectable pressure unit, Anti-chattering function, Display calibration function, Power-saving mode, Sub screen setting function
4A
3-Screen Display High-Precision Digital Pressure Switch ISE7 m/7 mG Series
For details, refer to the Web Catalog.
For General Fluids: Remote Type Variations Click here for the PSE56 series. Click here for the PSE57 series.
Select either the integrated type or the remote type according to the application.
ISE7G (With bracket B)
<Integrated type>
Steel tube
piping
Hydraulic
manifold
Hydraulic cylinder
PSE300AC
<Remote type>
Steel tube
piping
PSE57m
Hydraulic
manifold
Hydraulic cylinder
CONTENTS
3-Screen Display High-Precision 3-Screen Display High-Precision
Digital Pressure Switch: For Air Digital Pressure Switch: For General Fluids
ISE70/71 Series ISE70G/75G/76G/77G Series
How to Order·································································· p. 6 How to Order·································································· p. 8
Options/Part Nos.··························································· p. 6 Options/Part Nos.··························································· p. 8
Specifications································································· p. 7 Specifications································································· p. 9
Set Pressure Range and Rated Pressure Range························································································································· p. 10
Internal Circuits and Wiring Examples·········································································································································· p. 10
Dimensions··················································································································································································· p. 11
Function Details············································································································································································ p. 12
Safety Instructions······························································································································································ Back cover
B 5
®
ISE70/71 Series
How to Order
ISE70 02 L2 M
Pressure range
Symbol Description Option 3
ISE70 0 to 1 MPa Symbol Description
ISE71 0 to 1.6 MPa Nil Operation manual
Y None
Operation manual +
Piping specification K Calibration certificate
Symbol Description
T Calibration certificate
02 Rc1/4
N02 NPT1/4
F02 G1/4*1 Option 2
Symbol Description
*1 ISO 1179-1 compliant
Nil None
Output specification*1 A
Bracket A
(Interchangeable with ISE70)
Symbol Description
B Bracket B
IO-Link: Switch output 1 + Switch output 2
L2 (Switch output: NPN or PNP switching type)
Switch output 1 + Switch output 2 Option 1
AB (NPN or PNP switching type) Symbol Description
*1 Refer to pages 7 and 10 for details. Nil None
S Lead wire with M12 connector (Straight, 5 m)
Unit specification L Lead wire with M12 connector (Right-angled, 5 m)
Symbol Description
Nil Unit selection function*1
M SI unit only*2
*1 U
nder the New Measurement
Act, switches with the unit selec-
tion function are not permitted for
use in Japan.
*2 Fixed unit: MPa, kPa
Options/Part Nos.
When only optional parts are required, order with the part numbers listed below.
Description Part no. Note
Lead wire
with M12 connector: ZS-31-B Lead wire length: 5 m
Straight
Lead wire
with M12 connector: ZS-31-C Lead wire length: 5 m
Right-angled
6A
ISE70/71 Series
For pressure switch precautions and specific product precautions, refer
to the “Operation Manual” on the SMC website. Click here for details.
Specifications
Display RoHS
ISE70G/75G/76G/77G Series
How to Order
ISE70G 02 L2 M
Pressure range
Symbol Description Piping specification
ISE70G 0 to 1 MPa Symbol Description
ISE75G 0 to 2 MPa 02 Rc1/4
ISE76G 0 to 5 MPa N02 NPT1/4 Option 3
ISE77G 0 to 10 MPa F02 G1/4*1 Symbol Description
*1 ISO 1179-1 compliant Nil Operation manual
Y None
Orifice
Operation manual +
Symbol Description K Calibration certificate
Nil None
T Calibration certificate
T Yes*1
*1 O
rifice is shipped together Option 2
with the product.
Symbol Description
Output specification*1 Nil None
Symbol Description Bracket A
A (Interchangeable with ISE75(H))
IO-Link: Switch output 1 + Switch output 2
L2 (Switch output: NPN or PNP switching type) B Bracket B
*1 Refer to pages 9 and 10 for details.
Option 1
Unit specification Symbol Description
Symbol Description Nil None
Nil Unit selection function*1 Lead wire with M12 connector
M SI unit only*2 S (Straight, 5 m)
*1 U
nder the New Measurement Lead wire with M12 connector
Act, switches with the unit selec- L (Right-angled, 5 m)
tion function are not permitted for
use in Japan.
*2 Fixed unit: MPa, kPa
Options/Part Nos.
When only optional parts are required, order with the part numbers listed below.
Description Part no. Note
Orifice ZS-48-A
Lead wire
with M12 connector: ZS-31-B Lead wire length: 5 m
Straight
Lead wire
with M12 connector: ZS-31-C Lead wire length: 5 m
Right-angled
8A
ISE70G/75G/76G/77G Series
For pressure switch precautions and specific product precautions, refer
to the “Operation Manual” on the SMC website. Click here for details.
Specifications
Pressure range
Switch
−0.1 MPa 0 1 MPa 2 MPa 5 MPa 10 MPa
0 1.6 MPa
For 1.6 MPa
ISE71 −0.105 MPa
(For air)
1.68 MPa
0 2 MPa
For 2 MPa
ISE75G −0.105 MPa
(For general fluids)
2.1 MPa
0 5 MPa
For 5 MPa
ISE76G −0.25 MPa
(For general fluids)
5.25 MPa
0 10 MPa
For 10 MPa
ISE77G −0.50 MPa
(For general fluids)
10.5 MPa
When used as a switch output device * The numbers in the circuit diagrams show the connector pin layout.
Setting of NPN open collector 2 outputs Setting of PNP open collector 2 outputs
Brown DC(+) q Brown DC(+) q
Load
Main circuit
+ +
12 to 24 VDC 12 to 24 VDC
White OUT2 w − White OUT2 w −
Load
Load
Black C/Q r
Main circuit
C/Q
IO-Link
White DO w master
DI
Blue L− e
L−
10
ISE7 m/7 mG Series
Dimensions
Without bracket Bracket A (Interchangeable with ISE70/ISE75(H))
48 (Part no.: ZS-50-A)
10 49
(40.1)
34
(26)
15
14
6.5
80.4
70.4
(11.4)
8 1.6
46 25
60
Bracket B
24
(Part no.: ZS-50-B) 49
Piping port
02: Rc1/4 24 6
N02: NPT1/4
F02: G1/4 (ISO 1179-1)
24
22
2 x M4 thread depth 5
15
12
5.5
6.5 1.6
32 25
42
Lead wire with M12 connector
(Part no.: ZS-31-B)
5000 (38.6)
Brown 45
30 1: Brown 2: White
White Cable Specifications
Nominal cross section AWG23
ø15
Conductor
Blue Outside diameter 0.72 mm
4: Black 3: Blue
Material Cross-linked vinyl chloride
Black M12
Insulator Outside diameter 1.14 mm
Number of cores 4
(Part no.: ZS-31-C) Sheath Material Oil resistant vinyl chloride
5000 (31)
Finished outside diameter ø4
Brown 45 23.5
White 30 When used as a switch output device
No. Description Lead wire color Note
1 DC(+) Brown 12 to 24 VDC
Blue
(30.8)
Switch ON Switch ON
Turns ON at the Difference between
Measured value set value or more. OFF ON and ON OFF
Switch OFF Switch OFF
Set value
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 MPa 0.40 0.45 0.50 0.55 MPa
Measured value
Switch ON Switch ON
Turns ON at the Difference between
set value or less. ON OFF and OFF ON
Switch OFF Switch OFF
Set value
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 MPa 0.45 0.50 0.55 0.60 MPa
Switch ON Switch ON
Turns ON at the Turns ON at the Difference between
Measured value set value or more. set value or less. ON and OFF
Set value
Switch OFF Switch OFF
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 MPa 0.2 0.3 ………
0.6 0.7 MPa
Measured value
Switch ON Switch ON
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 MPa 0.3 0.4 ………
0.5 0.6 MPa
12
ISE7 m/7 mG Series
Function Details
A Auto-preset function (F4) * When using with IO-Link, the set values cannot be changed by communication.
Auto-preset function, when selected in the initial setting, calculates and stores the set value from the measured pressure.
Using this function is possible to automatically determine the optimum set value based on the variation in measured pressure due to the repeated
operation of the device.
During zero-clear operation, pressure over ±7% F.S. is present. Note that the Perform zero-clear operation again
Residual
mode is returned to measurement mode automatically 1 second later. The zero after restoring the applied pressure to
pressure error
clear range varies by ±1% F.S. due to variation between individual products. an atmospheric pressure condition.
IO-Link master IO-Link version does not match that of the master. Ensure that the master IO-Link
version error The master uses version 1.0. version matches the device version.
If the error cannot be solved after the instructions above are performed, or errors other than those above are displayed, please contact SMC for investigation.
13
Function Details ISE7 m/7 mG Series
Function Details
<Principle>
This function averages pressure values measured during the response time set by the user and then
compares the average pressure value with the pressure set point value to output the result on the switch.
Pressure ↑ Momentary change
14
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.
Revision History
Edition B ∗ The ISE7G for general fluids has been added.
∗ Number of pages has been increased from 12 to 16.
WQ
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.