Professional Documents
Culture Documents
Paper Change PDF
Paper Change PDF
com
International Journal of Pharmaceutical Sciences and Drug Research 2012; 4(1): 63-69
ABSTRACT
A simple, selective, rapid, precise and isocratic reversed phase high-pressure liquid chromatography method has been
developed and validated for estimation of related substances of Naproxen in pharmaceutical dosage form. It was performed
on a YMC-ODS A Pack (5μ particles size) (250mm × 4.6mm) column using mobile phase containing Acetonitrile and 10
mM Ammonium acetate buffer pH 3.8 in ratio 550:450 v/v (pH 3.8 adjusted with acetic acid) at the flow rate 0.8 ml/min.
Detection was performed at 254 nm and a sharp peak was obtained for Naproxen at a retention time at about 5.9 ± 0.01 min.
Linear regression analysis data for the calibration plot showed there was a good linear relationship between response and
concentration in the range 0.25-3μg/ml; the regression coefficient was 1.000. The detection (LOD) and quantification
(LOQ) limits were 0.13 and 0.25μg/ml respectively. The method was validated for accuracy, precision, specificity,
robustness, and detection and quantification limits, in accordance with ICH guidelines. Statistical analysis proved the
method was precise, reproducible, selective, specific, and accurate for analysis of Naproxen and its impurities. The wide
linearity range, sensitivity, accuracy, short retention time, and simple mobile phase showed that the method is suitable for
routine quantification of impurities in Naproxen in pharmaceutical dosage forms with high precision and accuracy.
A detailed literature search was conducted to check the concentration of 125μg/ml was prepared. Placebo equivalent
available methods for quantification of Naproxen impurities to 250 mg of Naproxen was weighed and transferred in
in tablet formulation and very few information was available. separate 500 ml volumetric flask for each level and dissolved
Hence, it is decided to start the method development using in 250 ml of diluent. To this, Naproxen and all impurities
reversed phase chromatography; as reversed phase stock solution (125μg/ml) was spiked and then made up to
chromatography is most commonly used and ample columns the mark by diluent.
are available for reversed phase chromatography. Further, Accuracy as Recovery
considering the pKa of Naproxen 4.2, decided to select Accuracy was determined by the standard addition method.
mobile phase pH range near to pKa. Based on this Samples of Naproxen (500μg/ml) were spiked with 10, 25,
information, selected mobile phases were investigated in the 50, 100 and 120% impurities standard and the mixtures were
development of an HPLC method suitable for analysis of analyzed by the proposed method. The experiment was
Naproxen tablet formulation. These included Acetonitrile- performed in triplicate. Recovery (%) and RSD (%) were
Water-Acetic Acid, 550:450:1(v/v), Acetonitrile-Water- calculated for each concentration.
Orthophosphoric acid (pH 3.8 adjusted with triethylamine) Precision
550:450:1(v/v) and Acetonitrile: 10mM Ammonium acetate Precision was determined as both repeatability and
buffer (pH 3.8 adjusted with acetic acid) 550:450(v/v). The intermediate precision, in accordance with ICH
suitability of the mobile phase was decided on the basis of recommendations. Repeatability of sample absorbance was
the sensitivity of the method, suitability for stability studies, determined as intra-day variation and intermediate precision
time required for the analysis, ease of preparation and use of was determined by measurement of inter-day variation. For
readily available solvents. Mobile phase were premixed and inter-day variation, six homogenous test solutions of
filtered through a 0.45μm nylon filter and degassed. Naproxen were analysed. The intermediate precision of the
Optimization and finalization of mobile phase was also done method was checked on a different instrument, analysis being
based on observations for various parameters such as performed in different laboratory.
retention time, theoretical plates and resolution. Acetonitrile– Specificity
Water 50:50(v/v) was used as the diluent. The specificity of the method was determined by analysing
Procedure: Five tablets (each tablet containing 500 mg the standard solutions of Naproxen and impurities and the
Naproxen) of Naproxen were weighed accurately. The tablets spiked samples and exposing a solution (500μg/ml) of the
were finely powdered and powder equivalent to 250 mg of sample to acidic (conc. Hydrochloric acid), basic (5N
Naproxen was taken in a 500 ml volumetric flask and then Sodium Hydroxide) and oxidising (30% Hydrogen peroxide)
dissolved in 250 ml of diluent. The powder mixture was stress conditions. The resulting solutions were then analyzed
dissolved in the diluent with aid of sonication for 15 min and the analyte peak was evaluated both for peak purity and
with occasional swirling and then diluted up to the mark with for resolution from the eluting peaks of all impurities.
diluent. After setting the chromatographic conditions and Detection (LOD) and Quantification (LOQ) Limits
stabilizing the instrument to obtain a steady base line, the LOD and LOQ were determined by the S/N Method.
tablet sample solution was filtered through 0.45µm Nylon Samples spiked with impurities were injected and the peak
filter after discarding first 2 ml. The solution was injected areas were calculated.
into the chromatographic system and chromatogram was Robustness
recorded. The robustness of the method was determined to assess the
Method Validation [15-16] effect of small but deliberate variation of the
Linearity chromatographic conditions on the determination of Related
Standard stock drug solution of Naproxen with concentration Substances of Naproxen. Robustness was determined by
of 125μg/ml was prepared in diluent. For preparation of changing column manufacturer (two other brands of same
calibration curve of drug 1, 2.5, 5, 10, 12 ml of standard specifications), column of different lot but of same
stock solution of Naproxen were transferred to series of 500 manufacturer, changing buffer pH in mobile phase, change in
ml volumetric flasks and volume was made up to the mark column oven temperature to 20°C and 30°C, changing the
with the diluent. Each solution was injected after filtration mobile phase flow rate to 0.7 and 0.9 ml/min and the ratio of
through 0.45μm membrane filter and chromatograms were acetonitrile in the mobile phase to 520 and 605 ml. The
recorded at 254 nm. The prepared dilutions were injected in stability studies and filter studies also come under robustness.
series, peak area was calculated for each dilution, and Stability
concentration was plotted against peak area. The stability of the drug in solution during analysis was
Determination of Response Factor determined by repeated analysis of samples during the course
The response factor for all impurities with respect to of experimentation on the same day and also after storage of
Naproxen was evaluated at 3 concentration levels. This was the reference and spiked sample solutions for 24 hours at
done by spiking Naproxen and all Impurities on placebo. autosampler temperature (25 ± 1°C).
Data from the duplicate determinations was collected at 3 Filter Study
concentration levels from 50% to 150% of the impurity The 100% spiked test solutions were filtered through
concentration. i.e. 0.5%. The ratio of the slope of individual different makes of filters or centrifuged and analysed for
impurity to the slope of the drug substance is the response their suitability for the proposed method.
factor for the particular impurity with respect to Naproxen in
presence of excipients. Then this response factor was used in RESULTS AND DISCUSSION
denomination of calculation formula of % Impurity. Method Development
Preparation of Concentration Levels: A solution The HPLC procedure was optimized with a view to
containing Naproxen and each of the identified impurity at developing a method for stability-indicating assay. No
internal standard was used because no extraction or Linearity was established in concentration range of 0.25-
separation step was involved. Of several solvents and solvent 3μg/ml for Naproxen.
mixtures investigated, the mobile phase Acetonitrile: 10mM The linear regression data for the calibration plot were
Ammonium acetate buffer in ratio 550:450 v/v (pH 3.8 indicative of a good linear relationship between peak area
adjusted with acetic acid) was found to furnish sharp, well- and concentration over a wide range. The correlation
defined peaks with very good symmetry (1.1) and low tR coefficient was indicative of high significance. The intercept
(about 5.98 min) at the flow rate 0.8 ml/min. The other of the ordinate showed the calibration plot did not deviate
mobile phases tried did not resulted in chromatographic from linearity.
system as good as proposed method. Table 2: Linearity Data for Naproxen Related Substances method with
Study of retention time: A standard dilution of pure drug Acetonitrile: 10mM Ammonium acetate buffer in ratio 550:450v/v (pH
3.8) as mobile phase
containing 500μg/ml of Naproxen was prepared in diluent. 5 Theoretical
ml of Reference stock solution was diluted to 100 ml with Response
Set Concentration Concentration of
(Area) (y –
Diluent. Further 5 ml of this solution was diluted to 50 ml No. Level in (%) Naproxen (ppm) (x –
value)
with diluent and loaded in injection port of instrument fitted value)
LOQ (0.05%)-10% 0.2490 107.31368
with 20μl fixed volume loop. The solution was injected and 25% 0.6225 274.56520
chromatogram was recorded. The mean retention time for Set I 50% 1.2450 574.11203
Naproxen was found to be about 5.98 min. The 100% 2.4899 1088.57419
representative chromatogram of Naproxen is reported in Fig. 120% 2.9879 1320.48796
LOQ (0.05%)-10% 0.2490 114.39526
2. 25% 0.6225 282.60135
Observations of Naproxen Tablet Analysis Set
50% 1.2450 551.68503
II
The results of analysis for tablet formulation are reported in 100% 2.4899 1103.21751
Table 1. 120% 2.9879 1319.57599
LOQ (0.05%)-10% 0.2490 114.73356
25% 0.6225 277.14292
Set
50% 1.2450 547.40852
III
100% 2.4899 1101.43640
120% 2.9879 1320.26826
1200
Area Response
1000
800
600
400
200
Fig. 2: Chromatogram of Naproxen 0.0 0.5 1.0 1.5 2.0 2.5 3.0
12000
1400
1200 10000
Area response
Area response
1000
8000
800
6000
600
4000
400
200 2000
0
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Concentration in ppm Concentration in ppm
Fig. 4: Linearity Response for Naproxen: A graph of Concentration (x- Fig. 6: Linearity Response for Impurity II: A graph of Concentration (x-
value) against area response obtained (y-value) was plotted value) against area response obtained (y- value) is plotted.
8000
for Division =
Slope of 1.00* 6.84 8.15 1.02
6000 Impurity/Slope of
Naproxen
*It will be used for quantification of unknown impurities.
4000
Precision
2000 Analysis Repeatability
It was performed by carrying out the analysis of the six
0
homogenous solutions of same test sample and content of
impurities was calculated. The determinations were carried
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
out one after the other under conditions as similar as
Concentration in ppm possible. The relative standard deviation was calculated from
Fig. 5: Linearity Response for Impurity I: A graph of Concentration (x- the results of the obtained observations.
value) against area response obtained (y- value) is plotted.
The % content of Impurity II and total impurities was found Table 9: Intermediate Precision of the method
to be below quantification level for all the six homogenous % Content
Impurity Total
test solutions, hence the method is precise. Samp Impurity I Impurity II
III Impurities
Intermediate Precision les
Day Day Day Day
Day 1 Day 2 Day 1 Day 2
The intermediate precision of the method was checked by 1 2 1 2
determining precision on a different instrument, analysis N.D BLO BLO N.D N.D BLO BLO
1. N.D.
. Q Q . . Q Q
being performed in different laboratory on a different day. N.D BLO BLO N.D N.D BLO BLO
The % content of impurity II and total impurities was found 2. N.D.
. Q Q . . Q Q
to be below quantification level even when it is performed on 3. N.D.
N.D BLO BLO N.D N.D BLO BLO
a different instrument. The method is said to be precise with . Q Q . . Q Q
N.D BLO BLO N.D N.D BLO BLO
respect to the criteria of the intermediate precision. 4. N.D.
. Q Q . . Q Q
N.D BLO BLO N.D N.D BLO BLO
Table 7: Accuracy of Naproxen in Related Substances Method 5. N.D.
. Q Q . . Q Q
Volume of %Recovery N.D BLO BLO N.D N.D BLO BLO
Concen combined 2-acetyl- 6. N.D.
6-methoxy- Methyl(2S)-2-(6- . Q Q . . Q Q
tration impurities 6- BLO BLO BLO BLO
2- methoxynaphth Mean - - - -
Levels stock solution methoxy Q Q Q Q
naphthoic alene-2-
in % 125ppm naphthal %
acid yl)propionate - - - - - - - -
added (ml) ene RSD
102 93 94
10% 0.2 102 90 80
106 94 105 Specificity
99 89 90 The specificity of the method was determined by analysing
25% 0.5 101 88 92 the standard solutions of Naproxen and impurities and the
102 90 95 spiked samples and exposing a solution (500μg/ml) of the
99 87 84
50% 1.0 98 88 88
sample to stress conditions i.e. chemical conditions like conc.
101 90 84 Hydrochloric acid, 5N Sodium hydroxide, and 30%
98 88 85 Hydrogen peroxide and physical conditions like treatment
100% 2.0 100 89 83 with heat, light and heat/humidity conditions. There was no
101 90 86
100 89 87
degradation of Naproxen and no significant change in peak
120% 3.0 99 89 83 area and retention time of Naproxen in the presence of 5N
100 90 87 Sodium hydroxide and in heat/humidity conditions. In the
Mean Recovery rate 101 89 88 presence of conc. Hydrochloric acid, 30% Hydrogen
% Relative Standard
deviation
2 2 7 peroxide and in thermal and photo stability conditions, it was
Minimum 98 87 80 found there was a substantial change in the peak area of
Maximum 106 94 105 Naproxen, but not in the retention time. The results from
stress testing, including quantification of Naproxen after
Table 8: Analysis Repeatability (% Content of Impurities) exposure to stress conditions show the method is stability-
% Content indicating.
S. No
Impurity I Impurity II Impurity III Total Impurities
1. N.D. BLOQ N.D. BLOQ Detection (LOD) and Quantification (LOQ) Limits
2. N.D. BLOQ N.D. BLOQ The LOD and LOQ of the method were 0.13 and 0.25μg/ml
3. N.D. BLOQ N.D. BLOQ respectively, which indicated the method, can be used for
4. N.D. BLOQ N.D. BLOQ detection and quantification of trace amounts of Naproxen
5. N.D. BLOQ N.D. BLOQ
6. N.D. BLOQ N.D. BLOQ
impurities over a wide range of concentrations.
Mean - BLOQ - BLOQ Robustness
% RSD - - - - There were no significant changes in the retention time of
Naproxen when the composition, column oven temperature
Table 10: Degradation Conditions of Naproxen API
Name of the Peak in Degraded Naproxen Assay of Total Imp. for
Stress % Impurity Assay of Degraded Mass
Sample Untreated Degraded
conditions /Peak purity Naproxen API Balance
Naproxen Imp. I Imp. II Imp. III Naproxen API Naproxen API
% Impurity – ND BLOQ ND
Conc. HCl 99.0 96.6 1.0 98.6
Peak purity 979 – – –
% Impurity – ND BLOQ ND
30% H2O2 99.0 94.0 4.0 99.0
Peak purity 987 – – –
% Impurity – ND BLOQ ND
5N NaOH 99.1 99.8 0.0 100.7
Peak purity 979 – – –
Thermal % Impurity – BLOQ BLOQ ND
Treatment 99.2 98.8 0.0 99.6
Peak purity 978 – – –
105°C
Photolytic % Impurity – BLOQ 0.16 ND
99.2 97.0 0.33 98.1
Exposure Peak purity 980 – 1000 –
Heat/ % Impurity – BLOQ ND ND
Humidity
Conditions 99.2 98.6 0.0 99.4
Peak purity 979 – – –
40°C/75%
RH
Note: The analysis of Untreated Naproxen API was carried out simultaneously with each forced degraded samples of Naproxen API and the % Impurity
observed in Untreated Naproxen API was below Quantification limit (BLOQ).
Table 13: Results from testing of the Robustness of the method by small changes in chromatographic conditions
Retention time Theoretical Tailing factor Resolution Resolution Resolution
Condition for Naproxen plates for for Naproxen between Naproxen between Naproxen between Naproxen
peak (tR) Naproxen peak peak and Impurity-I and Impurity-II and Impurity-III
Normal (D-192) 6.155 5912 1.2 2.5 6.0 13.3
Different lot (LC-223) 5.993 5810 1.2 2.8 6.7 13.9
Different lot (D-193) 7.728 21910 1.1 6.9 14.9 33.1
Different column
7.777 19872 1.3 6.9 13.7 31.2
Cosmosil (D-150)
Different column
7.845 19799 1.1 7.9 15.6 33.1
Kromasil (A-310)
Mobile Phase composition
6.516 5853 1.2 3.3 7.2 15.5
- 520:480 v/v
Mobile Phase composition
5.306 5985 1.2 1.9 5.3 10.9
- 605:395 v/v
Buffer pH 4 7.029 6261 1.2 3.5 7.2 16.1
Buffer pH 3.7 6.169 5927 1.2 2.4 5.8 12.9
Flow rate - 0.9 ml/min 6.801 21661 1.0 6.8 14.7 32.5
Flow rate - 0.7 ml/min 8.724 22399 1.0 6.9 14.8 32.1
Column oven -20°C 7.855 21222 1.0 6.7 14.7 28.9
Column oven -30°C 7.441 22903 1.1 7.0 14.9 32.6
(The concentration of the spiked test solution analysed was of 500μg/ml)
Table 14: Stability of the Reference Solution tailing factor of Naproxen and resolution of impurities,
Time Area of % Content % Change Reported %
shown in Table indicated the robustness of the method.
in hrs Naproxen w. r. t. 0 hr w. r. t. 0 hr change w. r. t. 0 hr
0.0 1092.9 100.0 0.0 Stability
0
5 1109.2 101.5 -1.5 The stability of the drug in solution during analysis was
-1
8.7 1087.8 99.5 0.5 determined by repeated analysis of the reference and spiked
0
12:5 1082.5 99.1 0.9 1
sample solutions during the course of experimentation on the
14.0 1093.6 100.1 -0.1 0
19.0 1088.8 99.6 0.4 same day and also after their storage at autosampler
0
23.0 1085.2 99.3 0.7 temperature (25 ± 1°C).
1
27.0 1101.8 100.8 -0.8 The reference solution stability was established up to 28 hrs
-1
28.5 1094.1 100.1 -0.1 0
and the spiked sample stability was established up to 23 hrs.
Filter Suitability Test
and flow rate of the mobile phase were changed. Changes The filter study was carried out by analyzing following
were observed in the retention time of Naproxen when there solutions
is a change in column and buffer of the mobile phase. For all 100% spiked Test solution unfiltered but centrifuged.
changed parameters, system suitability parameters of the 100% spiked Test solution filtered with different makes of
proposed method were fulfilled. The theoretical plates and the filters.
IJPSDR January-March, 2012, Vol 4, Issue 1 (63-69) 68
Mehta et al. / Development and Validation of Related Substances Method by HPLC for Analysis…..……
No significant change was observed in the filtered spiked test method was found to be accurate and precise as indicated by
solutions when compared with unfiltered spiked test the recovery studies and relative standard deviation. The
solutions. For filtration of test solution, different makes of Relative Response factor for impurities determined from
nylon filters can be used. Therefore, MDI make SY25NN validation can be used for quantification of impurities in
0.45µm and Valuprep make 0.45µm Nylon filters are suitable Naproxen in routine testing, by which there is no need to use
filters for the filtration of test solution. impurities’ standard. The method has been found to be better
than previously reported methods, because of its wide range
Table 15: Stability of the Spiked Sample Solution: Impurity I of linearity, use of readily available mobile phase, simplified
Time % % Impurity I Reported % Impurity I extraction procedure, low retention time (tR) and no internal
(hrs) Impurity I change w. r. t. 0 hr change w. r. t. 0 hr
0.0 0.20 0.00 0 standard. All these factors make this method suitable for
3.6 0.20 0.00 0 quantification of impurities in Naproxen in pharmaceutical
7.5 0.20 0.00 0 dosage forms without interference and can be successfully
9.1 0.20 0.00 0 used for routine analysis. It can therefore be concluded that it
10.9 0.20 0.00 0
15.1 0.20 0.00 0 can be used in small laboratories with very high accuracy and
19.4 0.20 0.00 0 a wide linear range.
23.5 0.20 0.00 0
ACKNOWLEDGEMENT
Table 16: Stability of the Spiked Sample Solution: Impurity II The authors are thankful to Sandoz Pvt. Ltd., Mumbai, India
Time % Impurity % Impurity-II Reported % Impurity II
for providing the sample of Naproxen as a gift and for
(hrs) II change w. r. t. 0 hr change w. r. t. 0 hr
0.0 0.16 0.00 0 providing necessary facilities to carry out the research work.
3.6 0.16 0.00 0
7.5 0.16 0.00 0 REFERENCES
9.1 0.16 0.00 0 1. Todd PA, Clissold SP. Drugs 1990; 40: 91.
10.9 0.16 0.00 0 2. Kanoute G, Nivaud E, Paulet B, Boucly P. Determination of
15.1 0.16 0.00 0 phenylpropionic acid derivatives: A pharmacological activity by
19.4 0.16 0.00 0 coulometric titration. Talanta 1984; 31: 144.
23.5 0.16 0.00 0 3. Mahrous MS, Abdel-Khakel MM, Abdel-Mamid ME. Quantitation
of indomethacin, naproxen, and ibuprofen in pharmaceutical dosage
Table 17: Stability of the Spiked Sample Solution: Impurity III forms by first and second derivative ultraviolet spectrometry. J.
Time % Impurity % Impurity-III Reported % Impurity Assoc. Off. Anal. Chem. 1985; 68: 535-539.
(hrs) III change w. r. t. 0 hr III change w. r. t. 0 hr 4. Kulsum S, Padmalatha M, Sandeep K, Saptasila B, Vidyasagar G.
0.0 0.17 0.00 0 Spectrophotometric Methods for the Determination of Naproxen
3.6 0.16 0.01 0 sodium in Pure and Pharmaceutical Dosage Forms. Int. J. Res.
7.5 0.16 0.01 0 Pharm. Biomed. Sci. 2011; 2: 1303-1307.
9.1 0.15 0.01 0 5. Gondalia RP, Dharamsi AP. Spectrophotometric simultaneous
10.9 0.16 0.01 0 estimation of naproxen sodium and sumatriptan succinate in tablet
15.1 0.16 0.01 0 dosage forms. Int. J. Res. Pharm. Biomed. Sci. 2010; 1: 24-26.
19.4 0.16 0.01 0 6. Haque T, Talukder MU, Fatema SL, Kabir AKL. Simultaneous
23.5 0.15 0.02 0 Estimation of Naproxen and Ranitidine HCl by Using UV
Spectrophotometer. Stamford J. Pharm. Sci. 2008; 1: 18-24.
7. Carretero AS, Blanco CC, Garcia MIR, Diaz BC, Alberto FG.
Table 18: Solution Stability of Spiked Test Sample: Total Impurities
Simple and rapid determination of the drug naproxen in
Reported % Total pharmaceutical preparations by heavy atom-induced room
Time % Total % Total Impurities
Impurities change w. r. temperature phosphorescence. Talanta 1999; 50: 401–407.
(hrs) Impurities change w. r. t. 0 hr
t. 0 hr 8. Wainer JW, Doyle TD. Application of high-performance liquid
0.0 0.52 0 0 chromatographic chiral stationary phases to pharmaceutical analysis
3.6 0.52 0 0 structural and conformational effects in the direct enantiomeric
7.5 0.51 1.9 2 resolution of α-methylarylacetic acid antiinflammatory agents. J.
9.1 0.51 1.9 2 Chromatogr. 1984; 284: 117-124.
10.9 0.51 1.9 2 9. Kumar R, Singh P, Singh H. Development and Validation of RP-
15.1 0.51 1.9 2 HPLC Method for Simultaneous Estimation of Naproxen and
19.4 0.51 1.9 2 Pantoprazole in Pharmaceutical Dosage Form. Int. J. Pharm. Res.
23.5 0.50 3.8 4 Development; 2011; 12: 227-232.
10. Hsu YH, Liou YB, Lee JA, Chen CY, Wu AB. Assay of naproxen
Table 19: Observations of Filter Suitability test by high-performance liquid chromatography and identification of
% % % Total % its photoproducts by LC-ESI MS. Biomed. Chromatogr. 2006; 20:
Filter used Impurity Impurity Impurity Impurity 787-93.
I II III content 11. Xu Yu-jia. Determination of related substances in compound
Centrifuged & naproxen suppositories by RP-HPLC. Central South Pharmacy
12.41 11.19 10.20 33.8
unfiltered 2005:05.
Millipore 0.45µ, 12. Monser L, Darghouth F. Simultaneous determination of Naproxen
12.45 11.07 10.31 33.8
nylon filter and related compounds by HPLC by using porous graphite carbon
Valuprep 0.45µ, column. J. Pharm. Biomed. Anal. 2003; 32: 1087-1092.
12.39 11.12 10.70 34.2
nylon filter 13. Baeyens WRG, Weken G, Schelkens M. Diclofenac and naproxen
MDI SY25NN analysis by microbore liquid chromatography (LC) with native
0.45µ, nylon 12.42 11.10 10.41 33.9 fluorescence detection. J. Fluorescence 1995; 5: 131-134.
filter 14. United States Pharmacopeia 34, National Formulary 29, United
States Pharmacopoeial Convention 2011: 3602-3605.
15. ICH, Q2A “Text on validation of analytical procedures”, Int.
This HPLC method is sensitive, accurate, precise, Conference of Harmonization, Oct. 1994.
reproducible, specific, and stability-indicating. The proposed 16. ICH, Q3B “Text on validation of analytical procedures”:
method was found to be simple and linear in the methodology, Int. Conference of Harmonization, Nov. 1996.
concentration range 0.25-3.0μg/ml for Naproxen. This