You are on page 1of 8

UTS BETON PRATEGANG

Diketahui :

 Beton: fc  50MPa  Mutu Tulangan Biasa: fy  400MPa


kN
γc  24
3  Panjang Penampang: lp  16000mm
m
 Asumsi dimensi balok: h  900mm

 Tendon: fpu  1860MPa b  450mm


ds  12.7mm
2 Eps  195000MPa
Ae  99mm

γ  15%

kN kN
 Beban: SDL  12 DL  γc  b  h  9.72
m m

kN kN
LL  22 Wu  DL  SDL  21.72 
m m

Jawaban :
0.5
 Tinjau Beton: Ec  4700 ( fc MPa )  33234.018716 MPa
2
 Tinjau Penampang: Ac  b  h  405000 mm
Ic     b  h  27337500000.000004  mm
1 3 4
 
12

h
ct   450  mm
2

h
cb   450  mm
2

Ic
r   259.807621 mm
Ac

2 2
r  67500  mm
Rangkuman tegangan izin menurut SNI Beton Pasal 8.4.

Perhitungan Tegangan Izin

 Tegangan Izin Kondisi Awal (Sebelum Kehilangan Prategang)

Kekuatan Awal : fci  0.75 fc  37.5 MPa

Tegangan Tekan (Ujung Bentang) : Fcip  0.7 fci  26.25  MPa

Tegangan Tekan (Tengah Bentang) : Fci  0.6 fci  22.5 MPa

0.5
Tegangan Tarik (Tengah Bentang) : Fti  0.25 ( fci MPa )  1.530931 MPa

0.5
Tegangan Tarik (Ujung Bentang) : Ftip  0.5 ( fci MPa )  3.061862 MPa

 Tegangan Izin Kondisi Layan (Setelah Kehilangan Prategang)


Tegangan Tekan (Beban Tetap) : Fc  0.45 fc  22.5 MPa

Tegangan Tekan (Beban Total) : Fct  0.6 fc  30 MPa


0.5
Tegangan tarik Terjauh Kondisi Tarik : Ft  0.5 ( fc MPa )  3.535534 MPa

 Data Tegangan Baja Prategang

fpy  0.9 fpu  1674 MPa


Kekuatan Leleh baja Prategang :

Gaya Penarikan Baja Prategang : fp1  0.94 fpy  1573.56  MPa

Tetapi tidak lebih besar dari : fpizin  0.8 fpu  1488 MPa

fp  ( 0.94 fpy) if fp1  fpizin


fp  1488 MPa
fpizin otherwise

Segera setalah Transfer Prategang : fpi1  0.82 fpy  1372.68  MPa


fpiizin  0.74 fpu  1376.4 MPa
Tetapi tidak lebih besar dari :

fpi  ( 0.82 fpy) if fpi1  fpiizin fpi  1372.68  MPa

fpizin otherwise fpe  ( 1  γ)  fpi  1166.778 MPa

 Menghitung Momen maksimum


2
DL lp
M DL   311.04 kN m
8

 1   LL lp2  704  kN m


M LL   
8

 1   SDL  lp2  384  kN m


M SDL   
8

M total  M DL  M LL  M SDL  1399.04  kN m

 Cek Modulus Penampang


Modulus Penampang Maksimum
 ( 1  γ)  MDL  MSDL  MLL 3
st     0.059499 m
 γ  Fti  Fc 
( 1  γ)  M DL  M SDL  M LL 3
sb   0.195699 m
Ft  γ Fci

Modulus Penampang serat atas


Ic 3
St   0.06075  m cekst  "OK" if St  st
0.5 h
"Not Ok" otherwise

Modulus Penampang Serat Bawah cekst  "OK"


Ic 3
Sb   0.06075  m
0.5 h ceksb  "OK" if Sb  sb
"Not Ok" otherwise

cekst  "OK"

 Eksentrisitas
 h   100mm  350  mm
emaks   
2

e1  300mm

Kondisi awal pada balok serat atas, tengah bentang (tarik)

 M DL 
 Fti  
Pi 
 St   Ac  2693.627091  kN
 e1  ct 
1 
 2
 r 

Jumlah strand:
Pi
n Strand   19.767767
0.74 fpu Ae

Maka diambil
n strand  15

2
Aps  n strand Ae  1485 mm

PiPakai  fpi Aps  2038.4298  kN

Pe  PiPakai  ( 1  γ)  1732.66533 kN
 PEMERIKSAAN TEGANGAN
 TENGAH BENTANG
Kondisi Awal:
PiPakai PiPakai  cb e1 M DL cb
fai     0.08684  MPa Fti  1.530931 MPa
Ac Ic Ic

cek1  
"OK" if fai  Fti 
"NOT OK" otherwise

cek1  "OK"

PiPakai PiPakai  cb e1 M DL cb


fbi     9.97948  MPa
Ac Ic Ic
Fci  22.5 MPa

cek2  
"OK" if fbi  Fci 
"NOT OK" otherwise

cek2  "OK"

Kondisi Layan:
Pe Pe cb e1 M total cb
fa     18.751279  MPa Fct  30 MPa
Ac Ic Ic
cek3  "OK" if fa  Fct 
"NOT OK" otherwise

cek3  "OK"

Pe Pe cb e1 M total cb


f.b     10.194907  MPa Ft  3.535534 MPa
Ac Ic Ic
cek4  
"OK" if f.b  Ft 
"NOT OK" otherwise

cek4  "NOT OK"

 TUMPUAN e2  50mm

Karena perletakan balok merupakan sendi-roll maka momen di tumpuan=0

Kondisi Awal:
PiPakai PiPakai  cb e2
fai2    6.71088  MPa Fcip  26.25  MPa
Ac Ic

cek5  
"OK" if fai2  Fcip 
"NOT OK" otherwise

cek5  "OK"
PiPakai PiPakai  cb e2
fbi2    3.35544  MPa
Ac Ic Fcip  26.25  MPa

cek6  
"OK" if fbi2  Fcip 
"NOT OK" otherwise

cek6  "OK"

Kondisi Layan:
Pe Pe cb e2 Fct  30 MPa
fa2    5.704248 MPa
Ac Ic cek7  
"OK" if fa2  Fct 
"NOT OK" otherwise

cek7  "OK"

Pe Pe cb e2 Fct  30 MPa


fb2    2.852124 MPa
Ac Ic
cek8  
"OK" if fb2  Fct 
"NOT OK" otherwise

cek8  "OK"

PERHITUNGAN TULANGAN NON PRATEGANG


1. Momen Terfaktor

kN
Wu  [ 1.2 ( SDL  DL) ]  ( 1.6 LL)  61.264
m

momen terfaktor dihitung dengan:


2
Wu  lp
M u   1960.448 kN m
8
2. Tegangan baja prategang fps pada kekuaran nominal
TENGAH BENTANG
fpe  1166.778 MPa
0.5 fpu  930  MPa

cek9  "OK" if ( fpe  0.5 fpu)


"NOT OK" otherwise

cek9  "OK"

Dengan demikian, prosedur pendekatan ACI untuk menentukan fps dapat


digunakan.
Asumsi KASUS TERLEKAT
fpy
 0.9 maka γp  0.28
fpu

Asumsi digunakan 4D25


n  4
D  25mm
1 2 2
As  n   π D  1963.495408  mm
4
d p  ct  e1  750  mm

d  h   40 mm   10 mm  837.5  mm


D

Aps 2 
ρp   0.0044
b dp

As fy
ω    0.04168
b  d fc

β1  0.85  0.008    30  0.69


fc
 MPa 

Untuk ω2  0

 γp  fpu d 
fps  fpu 1   ρp    
ω  ω2   1701.328005  MPa
 β1  fc d p 
Aps  fps  As fy
a   173.169686 mm
0.85 fc b

Untuk penampang persegi panjang dengan tulangan tarik dan tekan dari baja lunak
d
cek1  ω 
dp
ω  ω2  0.088222
cek2  0.36 β1  0.2484

cek1 < cek2 maka rumus Mn adalah: (asumsi tidak ada tulangan atas).

Mndesain  Aps  fps   d p    As fy   d    2265.867261  kN m


a a
ϕ  0.9
 2   2

ϕ Mndesain  2039.280535 kN m

M u  1960.448 kN m
cek10  
"OK" if ϕ Mndesain  M u 
"NOT OK" otherwise

cek10  "OK"

Cek Momen Retak


Tegangan tarik retak: fr  0.62 γ fc MPa  0.657609 MPa

Menghitung momen retak penampang:


 r 
2
M cr  fr Sb  Pe  e1    819.649164 kN m Pe  1732.66533 kN
 cb 

cek11  "OK" if ϕ Mndesain  M cr cek11  "OK"

"NOT OK" if ϕ Mndesain  M cr