Professional Documents
Culture Documents
DATA PENGAMATAN STHE-DPHE - Fix
DATA PENGAMATAN STHE-DPHE - Fix
WAKTU
(LPM) (LPM) IN OUT IN OUT KONDENSAT (Kg)
0 60 40 20 28
3 46 38 26 38
6 48 37 21 26 0.42
3
9 48 37 21 28 0.46
12 49 37 21 28 0.44
15 52 36 21 28 0.42
0 52 36 21 25
3 54 34 21 25 0.42
2.16
6 6 55 33 21 25 0.38
9 56 32 22 25 0.38
12 54 32 22 25 0.38
0 56 31 21 24
3 60 31 22 25 0.52
6 9 52 32 22 24 0.46
9 50 32 22 24 0.46
12 45 32 22 24 0.4
0 43 38 21 28
3 40 37 21 26 0.36
6 3.14 43 34 21 27 0.48
9 46 38 21 28 0.5
12 44 38 21 28 0.64
0 46 43 21 29
3 47 44 21 29 0.8
6 3 4.8 41 40 21 28 0.56
9 40 38 21 27 0.56
12 40 37 21 28 0.38
0 42 37 22 28
3 46 38 21 28 0.44
6 4.2 48 36 21 28 0.46
9 50 38 21 30 0.5
12 50 38 21 30 0.52
AVERAGE M MASSA AIR DINGIN (Kg) MASSA KONDENSAT (Kg)
4.54 0.42
0.46
0.44
0.435 RUN 1
0.42
0.42
0.38
0.39 RUN 2 0.38
0.38
2.32
2.88 0.52 2.84
0.46 RUN 3 0.46 3.34
0.46 3.3
0.4 3.74
2.3
2.12 0.36 2.66
0.495 RUN 1 2.44 0.48
0.5 2.94
0.64 3.58
CO CURRENT
CO CURRENT
0.6 HIJAU
0.58 PINK
PINK
T
WAKTU LAJU AIR LAJU AIR T HOT T COLD
(MENIT) DINGIN (LPM) PANAS (LPM) IN OUT IN OUT
0 40 30 21 24
3 42 34 21 26
6 6 40 36 21 26
9 40 33 21 26
12 38 33 21 26
0 40 32 21 25
3 40 32 21 25
6 8 5 42 33 21 26
9 46 36 21 26
12 48 37 21 26
0 48 37 21 26
3 46 36 21 26
6 10 44 35 21 26
9 43 34 21 25
12 39 32 21 24
0 36 32 21 25
3 35 30 21 25
6 6 34 30 21 25
9 33 28 21 24
12 32 28 21 24
0 35 26 21 24
3 36 30 21 24
6 6 4 34 28 21 24
9 36 28 21 24
12 36 28 21 24
0 32 28 21 22
3 33 28 21 24
6 5 32 28 21 24
9 32 28 21 24
12 32 28 21 24
MASSA
KONDENSAT (Kg)
pink 2.8 0.62
0.62 3.44 0.58
0.58 RUN 1 0.62 4.04
0.62 0.54 4.56
0.54
PINK 4.48 0.56
0.56 ijo 5.12 0.62
0.62 RUN 2 pink 5.1 0.72 COUNTER CURR
0.72 ijo 2.08 0.78
0.78 5.88
pink 2.68 0.68
0.68 pink 3.36 0.48
0.48 RUN 3 3.84 0.62
0.62 pink 5.16 0.76
0.76 5.34
pink 2 5.64
0.48 ijo 2 5.84 0.48
0.5 RUN 1 pink 3 6.14 0.5
0.5 0.5
0.48 0.48
Flow dingin massa jenis laju alir massa laju alir massa Cp (j/kg ΔTh (oC) ΔTc (oC)
(m3/s) (kg/m3) dingin (kg/s) panas (kg/s) oC)
STHE
Flow dingin massa jenis laju alir massa laju alir massa Cp (j/kg ΔTh (oC) ΔTc (oC)
(m3/s) (kg/m3) dingin (kg/s) panas (kg/s) oC)
0.006 5.98 4.98 6.8 4.6
0.008 996 7.97 4.98 4200 9.2 4.6
0.01 9.96 4.98 9.2 4.4
HE
hot cold
Efisiensi A(m2) Q rata-rata ΔTlmtd U (W/m2 WAKTU
Qh (W) Qc (W) (%) oC) (menit)
WAKTU
(menit)
0
3
6
9
12
T HOT (oC) T COLD (oC)
F AIR DINGIN F AIR PANAS MASSA
(m3/s) (m3/s) IN OUT IN OUT KONDENSAT (Kg)
60 40 20 28
46 38 26 28
0.003 48 37 21 26 0.42
48 37 21 28 0.46
49 37 21 28 0.44
52 36 21 25
54 34 21 25 0.42
0.00216
0.006 55 33 21 25 0.38
56 32 22 25 0.38
54 32 22 25 0.38
56 31 21 24
60 31 22 25 0.52
0.009 52 32 22 24 0.46
50 32 22 24 0.46
45 32 22 24 0.4
40 30 21 24
42 34 21 26 0.62
0.006 40 36 21 26 0.58
40 33 21 26 0.62
38 33 21 26 0.54
40 32 21 25
40 32 21 25 0.56
0.008 0.005 42 33 21 26 0.62
46 36 21 26 0.72
48 37 21 26 0.78
48 37 21 26
46 36 21 26 0.68
0.01 44 35 21 26 0.48
43 34 21 25 0.62
39 32 21 24 0.76
0.003 0.00216
ln
DT1 DT2 DT2-DT1 DT2/DT1
DT2/DT1
20 12 -8 0.60 -0.51
8 10 2 1.25 0.22
11 11 0 1.00 0.00
11 9 -2 0.82 -0.20
12 9 -3 0.75 -0.29
CO
CURRENT 16 11 -5 0.69 -0.37
20 9 -11 0.45 -0.80
22 8 -14 0.36 -1.01
24 7 -17 0.29 -1.23
22 7 -15 0.32 -1.15
25 7 -18 0.28 -1.27
29 6 -23 0.21 -1.58
20 8 -12 0.40 -0.92
18 8 -10 0.44 -0.81
13 8 -5 0.62 -0.49
16 9 -7 0.56 -0.58
16 13 -3 0.81 -0.21
14 15 1 1.07 0.07
14 12 -2 0.86 -0.15
12 12 0 1.00 0.00
15 11 -4 0.73 -0.31
15 11 -4 0.73 -0.31
COUNTER
CURRENT 16 12 -4 0.75 -0.29
20 15 -5 0.75 -0.29
22 16 -6 0.73 -0.32
22 16 -6 0.73 -0.32
20 15 -5 0.75 -0.29
18 14 -4 0.78 -0.25
18 13 -5 0.72 -0.33
15 11 -4 0.73 -0.31015493
DPHE
Flow panas massa jenis laju alir massa laju alir massa Cp (j/kg oC) ΔTh (oC) ΔTc (oC)
(m3/s) (kg/m3) dingin (kg/s) panas (kg/s)
0.00314 2.99 3.13 6.20 6.40
0.0048 996 2.99 4.78 4200 2.40 7.20
0.0042 2.99 4.18 9.80 7.60
STHE
Flow panas massa jenis laju alir massa laju alir massa Cp (j/kg oC) ΔTh (oC) ΔTc (oC)
(m3/s) (kg/m3) dingin (kg/s) panas (kg/s)
0.006 5.98 5.98 4.4 3.6
0.004 996 5.98 3.98 4200 7.4 3
0.005 5.98 4.98 4.2 2.6
DPHE
hot cold Efisiensi U (W/m2 WAKTU
A(m2) Q rata-rata ΔTlmtd
Qh (W) Qc (W) (%) oC) (menit)
81438.54 80317.44 98.62338 1 161755.98 6.87 23550.58 0
48190.46 90357.12 187.5 1 138547.58 5.61 24692.78 3
172180.51 95376.96 55.39359 1 267557.47 16.14 16574.65 6
9
12
STHE 0
hot cold Efisiensi U (W/m2 3
A(m2) Q rata-rata ΔTlmtd
Qh (W) Qc (W) (%) oC) 6
110436.48 90357.12 81.81818 1 200793.60 7.82 25674.75 9
123822.72 75297.60 60.81081 1 199120.32 9.14 21788.22 12
87847.20 65257.92 74.28571 1 153105.12 7.64 20042.48 0
3
6
9
12
0
3
6
9
12
0
3
6
9
12
0
3
6
9
12
F AIR DINGIN F AIR PANAS T HOT (oC) T COLD (oC) MASSA
(m3/s) (m3/s) IN OUT IN OUT KONDENSAT (Kg)
43 38 21 28
40 37 21 26 0.36
3.14 43 34 21 27 0.48
46 38 21 28 0.5
44 38 21 28 0.64
46 43 21 29
47 44 21 29 0.8
3 4.8 41 40 21 28 0.56
40 38 21 27 0.56
40 37 21 28 0.38
42 37 22 28
46 38 21 28 0.44
4.2 48 36 21 28 0.46
50 38 21 30 0.5
50 38 21 30 0.52
36 32 21 25
35 30 21 25 0.48
6 34 30 21 25 0.5
33 28 21 24 0.5
32 28 21 24 0.48
35 26 21 24
36 30 21 24 0.38
6 4 34 28 21 24 0.34
36 28 21 24 0.34
36 28 21 24 0.38
32 28 21 22
33 28 21 24 0.32
5 32 28 21 24 0.32
32 28 21 24 0.3
32 28 21 24 0.26
DT1 DT2 DT2-DT1 DT2/DT1 ln DT2/DT1
5 10 5 2.00 0.69
3 11 8 3.67 1.30
9 7 -2 0.78 -0.25
8 10 2 1.25 0.22
6 10 4 1.67 0.51
3 15 12 5.00 1.61
1 12 11 12.00 2.48
CO
CURRENT 2 11 9 5.50 1.70
3 9 6 3.00 1.10
5 9 4 1.80 0.59
8 10 2 1.25 0.22
12 8 -4 0.67 -0.41
12 8 -4 0.67 -0.41
12 8 -4 0.67 -0.41
4 7 3 1.75 0.56
10 9 -1 0.90 -0.11
9 9 0 1.00 0.00
9 7 -2 0.78 -0.25
8 7 -1 0.88 -0.13
11 5 -6 0.45 -0.79
12 9 -3 0.75 -0.29
10 7 -3 0.70 -0.36
COUNTER
CURRENT 12 7 -5 0.58 -0.54
12 7 -5 0.58 -0.54
10 7 -3 0.70 -0.36
9 7 -2 0.78 -0.25
8 7 -1 0.88 -0.13
8 7 -1 0.88 -0.13
8 7 -1 0.88 -0.13
8 7 -1 0.88 -0.13
Variasi Air Dingin
Flow dingin Flow panas
Qh (W) Qc (W) U (W/m2 oC) Efisiensi (%)
(m3/s) (m3/s)
0.003 112042.83 72787.68 13039.54 64.96
0.006 0.0216 187942.81 90357.12 20477.84 48.08
0.009 189749.95 90357.12 20848.33 47.62
90.00
80.00
Efisiensi (%)
50.00
40.00
0.0020.0030.0040.0050.0060.0070.0080.009 0.01
Laju Alir Air (m3/s)
Variasi Air Dingin
Flow dingin Flow panas U (W/m2 Efisiensi
Qh (W) Qc (W)
(m3/s) (m3/s) oC) (%)
0.006 142228.80 115456.32 20337.48 81.18
0.008 0.005 192427.20 153941.76 22802.04 80.00
0.01 192427.20 184060.80 23421.12 95.65
78.96
Grafik Efisiensi terhadap Variasi Laju Alir Air Panas dan Dingin
100
90
80
Efisiensi (%)
60
50 Grafik Efisiensi terhadap Variasi Laju Alir Air Panas dan DIngin [STHE]
100.00
40
75.00 80.00 85.0095.0090.00 95.00 100.00
Laju Alir Air (m3/s)
90.00
85.00
80.00
Axis Title