Professional Documents
Culture Documents
Vickers PVB pump PVB5 PVB6 PVB10 PVB15 PVB20 PVB29 PVB45
- Basic Characteristics
Type . . . . . . . . . . . . . Axial piston pumps
Operating pressure . . . . . up to 210 bar (3000 psi)
Displacement . . . . . 10,5 to 197,5 cm3/r (0.64 to 12 in3/r)
Drive speed . . . . . . . . .up to 3600 r/min
- Typical Section
Variable displacement model with compensator control “C” or “CM”
- General Description
Both fixed and variable displacement models make up this range of
axial piston pumps. Their high performance ratings and efficiencies
are achieved with a variety of hydraulic fluids. Fixed displacement
models are noted for their volumetric and mechanical efficiencies.
Variable displacement models can closely match pressure and/or
flow demand with a control selected from:
Pressure compensator with or
without a remote control facility.
Pressure compensator with adjustable displacement control.
Load sensing compensator.
Mechanical (lever) control.
Hand wheel control
Technical data:
Input Input
Geometric Out flow Speed Pressure KW Geometric Out flow Speed Pressure KW
Model displ. LPM rpm bar [hp] Model displ. LPM rpm bar [hp]
cm3/r [gpm] [psi] @high cm3/r [gpm] [psi] @high
[ in3/rev] @rpm pressure [ in3/rev] @rpm pressure
&speed &speed
10,55 18,9 210 13,0 10,55 37,8 210 13,0
PVB5 1800 PFB5 3600
[.64] [5] [3000] [17.5] [.64] [10] [3000] [17.5]
13,81 22,7 140 26,1 21,10 68,1 210 26,1
PVB6 1800 PFB10 3600
[.084] [6] [2000] [35] [1.294] [18] [3000] [35]
21,1 37,5 210 29,4 42,80 102 172 29,4
PVB10 1800 PFB20 3600
[1.29] [10.0] [3000] [39.5] [2.61] [27] [2500] [39.5]
33,0 59,4 141 29,4 94,4 208 210 71,7
PVB15 1800 PFB45 2200
[2.01] [15.7] [2000] [39.5] [5.76] [55] [3000] [96.1]
General Description
Both fixed and variable displacement
models make up this range of axial
piston pumps. Their high performance
ratings and efficiencies are achieved
with a variety of hydraulic fluids. Fixed
displacement models are noted for their
volumetric and mechanical efficiencies.
Variable displacement models can
closely match pressure and/or flow
demand with a control selected from:
Pressure compensator with or
without a remote control facility.
Pressure compensator with
adjustable displacement control.
Load sensing compensator.
Mechanical (lever) control.
Handwheel control
Functional Symbols
PFB PVB
Fixed displacement Variable displacement
models models
With handwheel,
or lever.
PVB 15- (F)- (M) R S (F)(X) Y-31 - ** - (C) - (G)- (L) -11 - ****
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PVB90 197,50 (12.0) 1800 1200 1200 210 (3000) 140 (2000) 140 (2000)
Supercharge pressure
Supercharge pressure
15
Supercharge pressure
1,8 0,8 2,0 1,0
Absolute pressure
Absolute pressure
30 10
1,6 1,8 0,8
0,6 30
25 1,6 0,6
1,4 0,4 25
5 1,4 0,4
20 5
1,2 0,2 20
1,2 0,2
1,0 0 0 15 1,0 0 0
10 0,8 170 m bar 10 0,8 170 m bar
(5 Hg)
0,6 0,6 (5 Hg)
0 2000 2400 2800 3200 1200 1800 2400 3000
Drive speed, r/min Drive speed, r/min
40 25
Supercharge pressure
1,8 0,8 2,6 1,6
25 10 35 2,4 1,4 20
Absolute pressure
Absolute pressure
PVB45 PVB90
psi bar bar psi psi bar bar psi
Supercharge pressure
Supercharge pressure
1,8 1,8
0,8 0,8
25 1,6 1,6
Absolute pressure
Absolute pressure
0,6 0,6
1,4 0,4 1,4 0,4
20 5 20 5
1,2 0,2 1,2 0,2
15 1,0 0 0 15 1,0 0 0
Vacuum: Vacuum:
0,8 170 m bar 0,8 170 m bar
10 (5 Hg) 10 (5 Hg)
0,6 0,6
0 1800 1900 2000 2100 2200 0 1200 1400 1600 1800
Drive speed, r/min Drive speed, r/min
Performance Data at 1500 r/min Drive Speed
With oil at 21cSt (102 SUS) and at 49 C (120 F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to
A.14
PFB5
US gpm L/min kW hp Nm lbf in
100
400
80 10 40
300
60 5 20 30
10
4 15
40 20 200
3 5
10 5 100
20 2
10
1 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
PFB10
100 US gpm L/min kW hp Nm lbf in
80 800
25
80
60 10 40 15 20 600
60
8 30 15
40 10 400
6 20 40
10
20 4
5 20 200
10 5
2
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
PFB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80
30 200
60 20 1500
150
20 80 15 20
1000
40 60 100
10
10 40 10
20 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 175 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 psi
Outlet pressure
Performance Data at 1500 r/min Drive Speed (cont’d)
With oil at 21cSt (102 SUS) and at 49 C (120 F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14
PVB5 US gpm L/min kW hp Nm lbf in
100
400
80 10 40
60 5 20 10 300
30
4 15
40 1 5 20 200
3
2 10 5
20 2 100
5 10
1
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
PVB6
100 US gpm L/min kW hp Nm lbf in
300
6 8 30
80 25 250
6 5
60 20 6 200
4 20
4 15 150
40 3 4
10 3 2 10 100
20 2 1 2
2 50
5 1
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 70 bar (1000 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)
3 = Delivery with compensator setting of 140 bar (2000 psi)
PVB10
100 US gpm L/min kW hp Nm lbf in
30
80 20 800
25 80
60 10 40 15 20 600
60
8 30
40 15 400
10
6 20 1 40
4 2 10
20 5 20 200
2 10 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
Performance Data at 1500 r/min Drive Speed (cont’d)
With oil at 21cSt (102 SUS) and at 49 C (120 F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14
PVB15 US gpm L/min kW hp Nm lbf in
100 800
80 700
80 600
14 60
60 15 60 8 10 500
6 8 40 400
40 10 40 1 300
6
4
20 2 4 20 200
20 5
2 2 100
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 50 bar (750 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)
PVB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80 30 200
60 20 1500
150
20 80 15 20
40 1000
60 100
10 1 10 10
40 3 4
20 2 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)
PVB29
100 US gpm L/min kW hp Nm lbf in
250
80 2000
30 200
25 100 20 1500
60 150
20 80 15 20
2 3 1000
40 15 60 100
1 10
10 40 4 10
20 50 500
5 20 5
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)
Performance Data at 1500 r/min Drive Speed (cont’d)
With oil at 21cSt (102 SUS) and at 49 C (120 F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14
PVB45
100 US gpm L/min kW hp Nm lbf in
400
80
3000
60 60 80 300
60 2000
40 150 200
40 40
30 100 2 40 1000
20 1
20 20 100
50 20
10
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
PVB90
100 US gpm L/min kW hp Nm lbf in
175 1000
80 125 8000
150 800
60 100 125 6000
80 300 75 100 600
40 75 4000
60 50 400
40 200 2 50
1
20 25 200 2000
20 100
25
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
Control Data for PVB Pumps
Controls available as indicated in “Model “CG” Pressure Compensator, “M” Lever Control
Code” section. Remotely Controlled Provides mechanical or manual variation
Same as the “C” compensator, but of pump delivery in approximate
“C” and “CM” Pressure arranged for remote pressure proportion to the angular movement from
Compensators adjustment by suitable pilot controls. the center position. This control may be
Automatically adjusts pump delivery at One or more pilot relief valves (e.g. operated on both sides of center
pre-adjusted pressure to match system C-175-*) and/or pilot directional valves, permitting bi-directional flow
demand. Delivery can decrease rapidly in series or in parallel, can provide many characteristics. The pintle-mounted lever
from maximum to zero through a varied remote pilot systems. control must be secured by suitable
pressure gradient typically 4 to 6 bar (60 linkage to maintain desired settings;
to 90 psi) with normal circuit volumes. Your Vickers representative will be both extremes of pintle travel are limited
pleased to advise on optimum by internal stops to approx. 17.5 from
For pressure adjustment ranges see arrangements for individual applications.
“Model Code”. center.
Note: “CV” Load Sensing Comensator, Control torques (approx. at 1500 r/min).
1. When using PVB6, 15 or 29 pumps Remotely Controlled PVB5 . . . . . . . . . . . . . 3,8 Nm @ 210 bar
with “C” type compensators ther user Automatically matches pump delivery to (33 lbf in at 3000 psi)
must ensure that the maximum system demand at a pressure PVB6 . . . . . . . . . . . . . 2,7 Nm @ 138 bar
pressure setting never exceeds 140 approximately 17 bar (250 psi) above (24 lbf in at 2000 psi)
or 100 bar (2000 or 1500 psi) load pressure. This pressure difference PVB10 and PVB15 . . 7,5 Nm @ 70 bar
dependent on the type of fluid being can be created by: (66 lbf in at 1000 psi)
used. – a variable flow restrictor (non-
Caution. It is possible to compensated flow control) or the Note: Torque varies with pressure and
mechanically adjust the spool opening of a directional control speed.
compensator up to 210 bar valve.
“GE1” Minimum Displacement
(3000 psi).
Both forms can be used with fixed and Control
2. It is recommended that, as for other
variable speed pump drives. In the latter Option for C(M)(C) and CG(C)
types of positive pump, a relief valve
case a fixed restrictor can provide pre- compensators to limit the minimum
should be fitted externally as
set, near-constant pump flow displacement, in the fully compensated
protection against overloads. Where
independent of drive speed, provided mode, to nominally 10% of full
a relatively large amount of fluid is
that the speed exceeds that which gives displacement.
directly subject to compensator
the required flow at full displacement. An
pressure, it may be possible to omit Hydraulic Fluids
external pressure limiter must be added
the relief valve. Consult your Vickers All pumps can be used with anti-wear
to prevent overloading the pump; see
representative. hydraulic oils, water glycols and
“Functional Symbols” page A.3.
“CC” and “CMC” Pressure water-in-oil (invert) emulsions. It is
The matching of pump pressure and possible to use these pumps with high
Compensators with Adjustable Max.
delivery to system demands provides water base fluids (e.g. 5%/95%
Displacement Stop
power matching and conservation by oil-in-water emulsion) at pressures up to
The pressure compensator section
minimizing system power wastage. 70 bar (1000 psi). However, first consult
performs as described above. The
your Vickers representative.
adjustable stop allows the maximum “H” Handwheel Control
pump delivery to be adjusted between Provides manual variation or selection of The extreme operating viscosity range
25 to 100%. To assist priming, adjust the pump delivery. The control can be is from 220 to 13 cSt (1020 to70 SUS)
stop setting to provide at least 40% of operated on both sides of center for all pumps (except where 5%/95%
the maximum displacement. permitting bi-directional flow emulsions are used). The
characteristics. recommended running range is 54 to 13
Approximate change of displacement cSt. (245 to 70 SUS)
per one turn of handwheel is:
PVB5 . . . . . . . . . . . . . 2,6 cm3 (0.16 in3) The viscosity of 5%/95% emulsions is
PVB6 . . . . . . . . . . . . . . 3,4 cm3 (0.21 in3) near-constant at about 1 or 2 cSt
PVB10 . . . . . . . . . . . . . 5,2 cm3 (0.32 in3) (<35 SUS).
PVB15 . . . . . . . . . . . . . . 8,2 cm3 (0.5 in3)
Temperature Limits * To obtain maximum service life from both - Drive Methods
Minimum ambient . . . . . . . –20 C (–4 F) fluid and hydraulic system, 65 C (150 F) Direct co-axial drive through a suitable
Maximum ambient. . . +70 C (+158 F) normally is the maximum temperature except flexible coupling is preferred. If an
for water-containing fluids. Whatever the indirect drive is to be used, first consult
Fluid Temperatures actual temperature range, ensure that your Vickers representative.
Mineral Water- viscosities stay within the limits specified in
oil containing Filtration Requirements
“Hydraulic Fluids” section.
Mininmum –20 C +10 C 20/18/14 or ISO 18/14..
(–4 F) (+50 F) Drive Requirements:
- Direction of Rotation
Maximum* +80 C +54 C
Clockwise or anti-clockwise (viewed at
(+176 F) (+129 F) shaft end) to order; see also “Model
Code”, and “Installation Dimensions”
sections.
Noise Levels
* Typical values equivalent to NFPA
Noise level – dB(A)*
Speed r/min Pressure bar (psi) Stroke PVB5 PVB6 PVB10 PVB15 PVB20 PVB29
Full flow 51 52 54 58 – –
35 (500)
Cutoff 51 51 44 47 – –
Full flow 54 55 56 60 – –
70 (1000)
Cutoff 52 54 49 54 – –
1000
Full flow 56 57 60 62 – –
140 (2000)
Cutoff 58 56 55 59 – –
Full flow 60 – 61 – – –
210 (3000)
Cutoff 59 – 59 – – –
Full flow 50 51 55 60 – –
35 (500)
Cutoff 52 51 48 51 – –
Full flow 54 55 57 61 74 70
70 (1000)
Cutoff 56 57 51 54 – –
1200
Full flow 59 59 60 63 74 73
140 (2000)
Cutoff 59 60 54 58 69 76
Full flow 60 – 62 – 78 –
210 (3000)
Cutoff 61 – 56 – – –
Full flow 54 54 58 63 – –
35 (500)
Cutoff 52 52 51 52 – –
Full flow 58 58 60 64 – –
70 (1000)
Cutoff 57 57 55 55 – –
1500
Full flow 61 62 62 66 – –
140 (2000)
Cutoff 62 59 62 59 – –
Full flow 64 – 65 –– – –
210 (3000)
Cutoff 62 – 63 –– – –
Full flow 57 58 61 64 – –
35 (500)
Cutoff 55 57 55 56 – –
Full flow 60 61 63 67 76 77
70 (1000)
Cutoff 59 58 59 60 – –
1800
Full flow 63 66 65 69 81 81
140 (2000)
Cutoff 62 63 62 64 75 81
Full flow 64 – 67 – 81 –
210 (3000)
Cutoff 64 – 65 – – –
Vickers PVB Pump and Its Part Number
www.hydpump.com