You are on page 1of 4

TEST REPORT

No. : TJIN1907009861MR
Date : Jul 04, 2019
Page: 1 of 4

CUSTOMER NAME: QINGDAO HENGLIAN PLASTIC CO., LTD


ADDRESS: GOVERNMENT BASE OF DUANPOLAN TOWN JIMO CITY
QINGDAO CHINA

Sample Name : PE TARPAULIN


Above information and sample(s) was/were submitted and confirmed by the client. SGS, however,
assumes no responsibility to verify the accuracy, adequacy and completeness of the sample
information provided by client.
***********
SGS Ref. No. : TP19-005331-1
Date of Receipt : Jul 01, 2019
Testing Start Date : Jul 01, 2019
Testing End Date : Jul 04, 2019
Test result(s) : For further details, please refer to the following page(s)
(Unless otherwise stated the results shown in this test report refer only to
the sample(s) tested)

Signed for
SGS-CSTC Standards Technical
Services(Tianjin) Co., Ltd

Mike Wang
Authorized signatory
TEST REPORT
No. : TJIN1907009861MR
Date : Jul 04, 2019
Page: 2 of 4

Summary of Results:
No. Test Item Test Method Result Conclusion
ASTM D2261- X direction 175.5N /
1 Tear Strength
13(2017) ε1 Y direction 199.0N /
ASTM D5035- X direction 827N /
2 Tensile Test
11(2015) Y direction 918N /

Note: Pass : Meet the requirements;


Fail : Does not meet the requirements;
/ : Not Apply to the judgment.

Original Sample Photo:

X direction

Sample
TEST REPORT
No. : TJIN1907009861MR
Date : Jul 04, 2019
Page: 3 of 4

1. Test Item: Tear Strength


Sample Description: Fabric
Test Method: ASTM D2261-13(2017) ε1
Test Condition:
Specimen width: 75mm
Testing speed: 50mm/min
Lab Environmental Condition: (23±2)℃, (50±5)%RH
Test Result:

Test Item Test Result

X direction 175.5N
Tear Strength
Y direction 199.0N
Note: Test specimens were cut from the sample.

Equipment Information:
Equipment Model Equipment No. Calibration date Next Calibration date
Universal Testing
Zwick Z010 POL-022 2018-11-05 2019-11-04
Machine
TEST REPORT
No. : TJIN1907009861MR
Date : Jul 04, 2019
Page: 4 of 4

2. Test Item: Tensile Test


Sample Description: Fabric
Test Method: ASTM D5035-11(2015)
Test Condition:
Specimen: Type 1R
Specimen width: 25 mm
Testing speed: 300 mm/min
Distance between the clamps: 75 mm
Lab Environmental Condition: 23 ± 2 ℃, 50 ± 5 % RH
Test Result:

Test Item Test Result

X direction 827N
Breaking Force
Y direction 918N
Note: Test specimens were cut from the sample.

Equipment Information:

Equipment Model Equipment No. Calibration date Next Calibration date

Universal
CMT4304 POL-116 2018-11-05 2019-11-04
Testing Machine
******** End of report********

Unless otherwise stated, the results show in this test report refer only to sample(s) tested; test report
shall only be used for clients’ scientific research, teaching, internal quality control, product research
and development, etc… and just for internal reference. Without written approval or consent of our
company, the test result shall not be used for improper publicity.

You might also like