You are on page 1of 10

(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea

Tel : 051-463-5462~4 Fax : 051-462-8803

TEST REPORT
●●●
APPLICANT : BAIKSAN CO., LTD. REPORT NO. : B233-15-03397
SAMPLE RECEIVED DATE : 2015-09-14
TEST STARTED DATE : 2015-09-14
REPORT ISSUED DATE : 2015-09-18
PAGE : 1 OF 10

DESCRIPTION : ONE(1) PIECE OF SUBMITTED CUTTING SAID TO BE PU SYNTHETIC.


========================================================================================
POLICY NUMBER : A-01
VERSION : 13
Sample Description : PU SYNTHETIC
Amount Of Sample : 1 EA
Buyer's Name / Division : Adidas Footwear
Summary of test report : PASS
Failure test items :-
Age Group : All ages
Material Name / Code : PU SYNTHETIC / 300
Color Name / Code : BLUE
Supplier name : BAIKSAN CO., LTD.
Contact Person : JAE KON CHOI
Country Of Origin :-
Country Of Destination : -
Material Component :-
Sample Classification : -
Test Key code No. : 300
Report Type : FT(Full Test)
Full test report No. :-
P.O. No. :-
========================================================================================
TEST CONDUCTED : AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE SEE ATTACHED PAGES.
========================================================================================

PREPARED AND CHECKED AUTHORIZED BY


FOR FITI FOR FITI

SANG-KI LIM MOON-OK NOH


QUALITY MANAGER PRESIDENT

※ Report Verification No.: WYSL-VH5E-FEMH ※


(You can see the authenticity of your test report through the above "Report Verification No." at FITI homepage.)

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 2 OF 10

TEST RESULT
SUBSTANCE TLV CONCLUSION
#1
ADULTS : 1.0
ARSENIC (As) EXTRACTION ND PASS
INFANTS : 0.2
ARSENIC (As) TOTAL ND 10 PASS
ADULTS : 10
ANTIMONY (Sb) ND PASS
INFANTS : 5
CADMIUM (Cd) EXTRACTION ND 0.1 PASS
HEAVY METAL'S CADMIUM (Cd) TOTAL ND 40 PASS
CONTENT ADULTS : 1
LEAD (Pb) EXTRACTION ND PASS
INFANTS : 0.2
LEAD (Pb) TOTAL ND 40 PASS
MERCURY (Hg) ND 0.02 PASS
ADULTS : 2
CHROMIUM (Cr) ND PASS
INFANTS : 1
CHROME Ⅵ (Cr Ⅵ) ND 3 PASS
pH 6.1 4.0 - 7.5 PASS
ADULTS : 0.5
∑ PCP, TeCP and TriCP ND PASS
INFANTS : 0.05
ADULTS : 1 000
o-PP ND PASS
INFANTS : 500
AZO-AMINES ND 20 PASS
ADULTS : 75
FORMALDEHYDE ND PASS
INFANTS : 13
DISPERSE DYES AND DYESTUFFS ND 50 PASS
MBT(MONOBUTYLTIN) ND 1 PASS
DBT(DIBUTYLTIN) ND 1 PASS
DOT(DIOCTYLTIN) ND 1 PASS
TBT(TRIBUTYLTIN) ND 0.05 PASS
ADULTS : 1
TPhT(TRIPHENYLTIN) ND PASS
INFANTS : 0.5
∑ OF ALL LEGISLATED PHTHALATES ND 500 PASS
NP ND 10 PASS
OP ND 10 PASS
∑ OF NP, OP, NPEO and OPEO ND 250 PASS
REGULATED POLYCYCLIC AROMATIC
ND 1 (FOR EACH) PASS
HYDROCARBONS(PAHs) OF HIGH CONCERN
∑ OF POLYCYCLIC AROMATIC HYDROCARBONS
ND 10 PASS
(PAHs)
PFOS, PFOA ND 1 PASS
∑ SHORT CHAINED CHLOROPARAFFINES
ND 1 000 PASS
C10 TO C13 (SCCP)
∑ MEDIUM CHAINED CHLOROPARAFFINES
ND 1 000 PASS
C14 TO C17 (MCCP)

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 3 OF 10

01. HEAVY METAL'S CONTENT : ㎎/㎏


SAMPLE No. #1
ARSENIC (As) EXTRACTION (DIN EN ISO 11885 : 2009) ND
ARSENIC (As) TOTAL (DIN EN ISO 11885 : 2009) ND
ANTIMONY (Sb) (DIN EN ISO 11885 : 2009) ND
CADMIUM (Cd) EXTRACTION (DIN EN ISO 11885 : 2009) ND
CADMIUM (Cd) TOTAL (DIN EN ISO 11885 : 2009) ND
LEAD (Pb) EXTRACTION (DIN EN ISO 11885 : 2009) ND
LEAD (Pb) TOTAL (DIN EN ISO 11885 : 2009) ND
MERCURY (Hg) (DIN EN ISO 12846 : 2012) ND
CHROMIUM (Cr) (DIN EN ISO 11885 : 2009) ND
CHROME Ⅵ (Cr Ⅵ) (EN ISO 17075 : 2007) ND
NOTE) ㆍTHE SAMPLE WAS PRETREATED ACCORDING TO DIN EN ISO 105-E04(2013) IN ACID SOLUTION FOR 1 h AT
37 ℃.
ㆍCADMIUM TOTAL : ALL SYNTHETIC MARTERIAL(POLYMER, SYNTHETICS, RUBBER ETC) AND ARTIFICIAL
COATED LEATHER WAS PRETREATED ACCORDING TO EN 1122(2001).
ㆍLEAD TOTAL : MICROWAVE DIGESTION WITH H2O2 / HNO3.
ㆍCHROMIUM Ⅵ : THE SAMPLE WAS PRETREATED OF AGING FOR 24 h, 80 ℃, 5 % R.H.
THE MASS FRACTION OF THE VOLATILE MATTER = 0.3 %
ㆍDETECTION LIMIT
- EXTRACTION : As / Sb / Pb / Cr / Cr Ⅵ = 0.1 ㎎/㎏, Cd = 0.01 ㎎/㎏, Hg = 0.005 ㎎/㎏
- TOTAL : As / Cd = 1 ㎎/㎏, Pb = 10 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

02. pH ( ISO 3071 : 2005 )


SAMPLE No. #1
TEST RESULT 6.1
NOTE)ㆍEXTRACTION SOLUTION : DISTILLED WATER(pH : 5.9)
ㆍ DISTILLED WATER TEMPERATURE : 23 ℃

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 4 OF 10

03. PCP CONTENT ( GC-MS ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍPCP = Pentachlorophenol
ᆞKOH EXTRACTION, DERIVATIZATION, FOLLOWED BY GC-MS ANALYSIS.
ㆍDETECTION LIMIT : 0.05 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

04. TeCP CONTENT ( GC-MS ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍTeCP = 2,3,4,5-Tetrachlorophenol
2,3,4,6-Tetrachlorophenol
2,3,5,6-Tetrachlorophenol
ᆞKOH EXTRACTION, DERIVATIZATION, FOLLOWED BY GC-MS ANALYSIS.
ㆍDETECTION LIMIT : 0.05 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

05. TriCP CONTENT ( GC-MS ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍTriCP = 2,3,4-Trichlorophenol
2,3,5-Trichlorophenol
2,3,6-Trichlorophenol
2,4,5-Trichlorophenol
2,4,6-Trichlorophenol
3,4,5-Trichlorophenol
ᆞKOH EXTRACTION, DERIVATIZATION, FOLLOWED BY GC-MS ANALYSIS.
ㆍDETECTION LIMIT : 0.05 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

06. o-PP CONTENT ( GC-MS ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍo-PP = Orthophenylphenol
ᆞKOH EXTRACTION, DERIVATIZATION, FOLLOWED BY GC-MS ANALYSIS.
ㆍDETECTION LIMIT : 10 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 5 OF 10

07. AZO-AMINES ( prEN ISO 14362-1 : 2015 / prEN ISO 14362-3 : 2015 ) : ㎎/㎏
SAMPLE No. #1
CAS NO.
4-AMINODIPHENYL 92-67-1 ND
BENZIDINE 92-87-5 ND
4-CHLORO-o-TOLUIDINE 95-69-2 ND
2-NAPHTYLAMINE 91-59-8 ND
o-AMINOAZOTOLUENE 97-56-3 ND
2-AMINO-4-NITROTOLUENE 99-55-8 ND
p-CHLOROANILINE 106-47-8 ND
2,4-DIAMINOANISOLE 615-05-4 ND
4,4'-DIAMINODIPHENYLMETHANE 101-77-9 ND
3,3'-DICHLOROBENZIDINE 91-94-1 ND
3,3'-DIMETHOXYBENZIDINE 119-90-4 ND
3,3'-DIMETHYLBENZIDINE 119-93-7 ND
3,3'-DIMETHYL-4,4'-DIAMINODIPHENYLMETHANE 838-88-0 ND
2-METHOXY-5-METHYLBENZENAMINE(p-CRESIDINE) 120-71-8 ND
4,4'-METHYLENE-BIS-(2-CHLOROANILINE) 101-14-4 ND
4,4'-OXYDIANILINE 101-80-4 ND
4,4'-THIODIANILINE 139-65-1 ND
o-TOLUIDINE 95-53-4 ND
2,4-TOLUENEDIAMINE 95-80-7 ND
2,4,5-TRIMETHYLANILINE 137-17-7 ND
2,4-XYLIDINE 95-68-1 ND
2,6-XYLIDINE 87-62-7 ND
2-METHOXYANILINE 90-04-0 ND
4-AMINOAZOBENZENE 60-09-3 ND
NOTE)ᆞDETECTION LIMIT : 5 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

08. FORMALDEHYDE CONTENT ( JIS L 1041 : 2011 8.1.4 METHOD B ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ᆞDETECTION LIMIT : 5 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 6 OF 10

09. DISPERSE DYES AND DYESTUFFS ( DIN 54231 : 2005 ) : ㎎/㎏


SAMPLE No. #1
NAME OF DYE
DISPERSE BLUE 1 ND
DISPERSE BLUE 3 ND
DISPERSE BLUE 7 ND
DISPERSE BLUE 26 ND
DISPERSE BLUE 35 ND
DISPERSE BLUE 102 ND
DISPERSE BLUE 106 ND
DISPERSE BLUE 124 ND
DISPERSE BROWN 1 ND
DISPERSE YELLOW 1 ND
DISPERSE YELLOW 3 ND
DISPERSE YELLOW 9 ND
DISPERSE YELLOW 23 ND
DISPERSE YELLOW 39 ND
DISPERSE YELLOW 49 ND
DISPERSE ORANGE 1 ND
DISPERSE ORANGE 3 ND
DISPERSE ORANGE 11 ND
DISPERSE ORANGE 37/59/76 ND
DISPERSE ORANGE 149 ND
DISPERSE RED 1 ND
DISPERSE RED 11 ND
DISPERSE RED 17 ND
ACID RED 26 ND
BASIC RED 9 ND
BASIC VIOLET 14 ND
DIRECT BLACK 38 ND
DIRECT BLUE 6 ND
DIRECT RED 28 ND
NOTE)ᆞDETECTION LIMIT : 15 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 7 OF 10

10. MBT(MONOBUTYLTIN) ( ISO/TS 16179 : 2012 ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍDETECTION LIMIT : 0.1 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

11. DBT(DIBUTYLTIN) ( ISO/TS 16179 : 2012 ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍDETECTION LIMIT : 0.1 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

12. DOT(DIOCTYLTIN) ( ISO/TS 16179 : 2012 ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍDETECTION LIMIT : 0.1 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

13. TBT(TRIBUTYLTIN) ( ISO/TS 16179 : 2012 ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍDETECTION LIMIT : 0.01 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

14. TPhT(TRIPHENYLTIN) ( ISO/TS 16179 : 2012 ) : ㎎/㎏


SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍDETECTION LIMIT : 0.1 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 8 OF 10

15. ∑ OF ALL LEGISLATED PHTHALATES ( CPSC-CH-C1001-09.3 : 2010 ) : %


SAMPLE No. #1
DINP (DI-ISO-NONYLPHTHALATE) ND
DNOP (DI-N-OCTYLPHTHALATE) ND
DEHP (DI(2-ETHYLHEXYL)-PHTHALATE) ND
DIDP (DIISODECYLPHTHALATE) ND
BBP (BUTYLBENZYLPHTHALATE) ND
DBP (DIBUTYLPHTHALATE) ND
DIBP (DIISOBUTYLPHTHLATE) ND
DIHP (DI-C6-8-BRANCHED ALKYLPHTHALATES) ND
DHNUP (DI-C711-BRANCHED ALKYLPHTHALATES) ND
DHP (DI-N-HEXYLPHTHALATE) ND
DMEP (DI-(2-METHOXYMETHYL)-PHTHALATE) ND
DPP (DI-PENTYLPHTHALATE) ND
NOTE)ㆍTHE SAMPLE WAS TESTED IN ACCORDANCE WITH U.S. CONSUMER PRODUCT SAFETY IMPROVEMENT ACT
(CPSIA) 2008(H.R.4040) TITLE 1.
ᆞDETECTION LIMIT : 100 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

16. ALKYLPHENOLS CONTENT ( GC/MS ) : ㎎/㎏


SAMPLE No. #1
NONYLPHENOL ND
OCTYLPHENOL ND
NOTE)ㆍTHE SAMPLE WAS EXTRACTED BY DICHLOROMETHANE AND THEN ANALYZED BY GC/MS.
ㆍDETECTION LIMIT : 10 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

17. ALKYLPHENOLETHOXYLATES CONTENT ( Draft DIN EN ISO 18254 : 2014 ) : ㎎/㎏


SAMPLE No. #1
NONYLPHENOLETHOXYLATES ND
OCTYLPHENOLETHOXYLATES ND
NOTE)ㆍDETECTION LIMIT : 50 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 9 OF 10

18. REGULATED POLYCYCLIC AROMATIC HYDROCARBONS (PAHs) OF HIGH CONCERN ( AfPS GS 2014 : 01 ) : ㎎/㎏
SAMPLE No. #1
BENZO(a)ANTHRACENE ND
BENZO(a)PYRENE ND
BENZO(b)FLUORANTHENE ND
BENZO(e)PYRENE ND
BENZO( j)FLUORANTHENE ND
BENZO(k)FLUORANTHENE ND
CHRYSENE ND
DIBENZO(a,h)ANTHRACENE ND
NOTE)ㆍDETECTION LIMIT : 0.5 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

19. ∑ OF POLYCYCLIC AROMATIC HYDROCARBONS (PAHs) ( AfPS GS 2014 : 01 ) : ㎎/㎏


SAMPLE No. #1
NAPHTHALENE ND
ACENAPHTHYLENE ND
ACENAPHTHENE ND
FLUORENE ND
PHENANTHRENE ND
ANTHRACENE ND
FLUORANTHENE ND
PYRENE ND
INDENE(1,2,3-cd)PYRENE ND
BENZO(g,h,i)PERYLENE ND
NOTE)ㆍDETECTION LIMIT : 0.5 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

20. FLUOROCARBONS CONTENT ( DIN CEN/TS 15968 : 2010-11 ) : μg/㎡


SAMPLE No. #1
PFOS (PERFLUOROOCTANE SULPHONATE) ND
PFOA (PERFLUOROOCTANOIC ACID) ND
NOTE)ㆍAFTER ULTRASONIFICATION WITH METHANOL FOR 1 h 80 ℃ AND FOLLOWED BY LIQUID
CHROMATOGRAPHY - MASS SPECTROMETRIC (LC-MS) ANALYSIS.
ᆞDETECTION LIMIT : 1 μg/㎡
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
(48732) 14, Jungang-daero, 248beon-gil, Dong-gu, Busan, Korea
Tel : 051-463-5462~4 Fax : 051-462-8803

REPORT NO. : B233-15-03397


PAGE : 10 OF 10

21. ∑ SHORT CHAINED CHLOROPARAFFINES C10 TO C13 (SCCP) ( Draft DIN EN ISO 18219 : 2012-12 ) : ㎎/㎏
SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍAFTER SOXHLET EXTRACTION WITH DICHLOROMETHANE, ANALYZED BY GC-MSD/ECD.
ᆞDETECTION LIMIT : 100 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

22. ∑ MEDIUM CHAINED CHLOROPARAFFINES C14 TO C17 (MCCP) ( Draft DIN EN ISO 18219 : 2012-12 ) : ㎎/㎏
SAMPLE No. #1
TEST RESULT ND
NOTE)ㆍAFTER SOXHLET EXTRACTION WITH DICHLOROMETHANE, ANALYZED BY GC-MSD/ECD.
ᆞDETECTION LIMIT : 50 ㎎/㎏
ㆍ ND = NOT DETECTED = LESS THAN DETECTION LIMIT

** End of The Report **

SAMPLE :

The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.

You might also like