You are on page 1of 5

Q 0.50124755 ft^3/s Q 0.

50124755
L1 8 ft L2 360
V1 7.29893898 ft/s V2 15.0685562
D1 0.2957 ft D2 0.2058
E1 0.00015 ft E2 0.00015
A1 0.06867403 ft^2 A2 0.03326447
L1/D1 27.0544471 L2/D2 1749.27114
Re 178371.592 Re 256289.988
f 0.0191 f 0.0197
V1^2/2g 0.82724395 ft V2^2/2g 3.5257979
D1/E1 1971.33333 D2/E2 1372
v 0.0000121 ft^2/s v 0.0000121

PERDIDAS cantidad ki ki total hi


Tuberia 1 1 0.5167399391 0.51673994 0.42746999 ft
Entrada 1 0.5 0.5 0.41362197 ft
Válvula de compuerta 1 0.1528 0.1528 0.12640288 ft
tuberia 2 1 34.460641399 34.4606414 121.501257 ft
Valvula de retencion 1 1.8 1.8 6.34643623 ft
Valvula mariposa 1 0.81 0.81 2.8558963 ft
codo estandar 2 0.54 1.08 3.80786174 ft
salida 1 1 1 3.5257979 ft
450
perdida total Hl 139.004744 ft
carga estatica 160.77 ft
400
Hb 299.774744 ft f(x) = 1.71

350
gal/min cfts SRC
0 0 160.77 ft
300
25 0.05569417 162.77 ft
50 0.11138834 167.586651 ft
75 0.16708252 176.21 ft 250
100 0.22277669 188.23 ft
125 0.27847086 203.67 ft 200
150 0.33416503 222.55 ft
175 0.38985921 244.86 ft 150
200 0.44555338 270.6 ft
caudal de diseño 225 0.50124755 299.77 ft 100
250 0.55694172 332.38 ft
275 0.6126359 368.42 ft 50
300 0.66833007 407.89 ft
0
0 25
ft^3/s
ft
ft/s
ft
ft
ft^2

ft

ft^2/s

450

400
f(x) = 1.717658992x^2 - 3.4606687672x + 162.6049841818

350

300

250

200

150

100

50

0
0 25 50 75 100 125 150 175 200 225 250 275 300

You might also like