Professional Documents
Culture Documents
10.001.34 - 10.001.35 Equipo de Presión Constante y Velocidad Variable PDF
10.001.34 - 10.001.35 Equipo de Presión Constante y Velocidad Variable PDF
Lenntech
IT T Goulds Pumps is a brand of ITT Corporation. Goulds Pumps is ISO 9001 Registered.
Goulds Pumps
Commercial Water
Contents
Coverage Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Market Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Characteristics of 1-22SV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Characteristics of 33-125SV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Applications of e-SV Pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
e-SV Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
1-22SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
33-92SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
125SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18
e-SV Mechanical Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Maximum Allowable Working Pressure Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Maximum Inlet Pressure / Motor Data - Starts Per Hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Motor Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-25
3500 RPM Curves, Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-47
1750 RPM Curves, Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-69
Horizontal Mounting Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-73
Table of Hydraulic Performances at 3500 RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74-79
Table of Hydraulic Performances at 1750 RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-85
Technical Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86-88
Lenntech
PAGE 3
Goulds Pumps
Commercial Water
METERS FEET
1200
350 3500 RPM
300 1000
250 800
200 22SV
600
150
125SV
400
100
200
50 46 66 92
1SV 3SV 5SV 10SV 15SV 33SV SV SV SV
0
1 2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 GPM
METERS FEET
300
1750 RPM
75 250
200
50
150
22SV
125SV
100
66 92
25 SV SV
50 33 46
1SV 3SV 5SV 10SV 15SV SV SV
0 0
1 2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 GPM
PAGE 4
Lenntech
Goulds Pumps
Commercial Water
MOTOR
• Standard NEMA TC Frame motors in open drip proof or totally
enclosed fan cooled.
• 3500 RPM nominal
• Standard voltage:
• Single phase version: 115-208/230 V, 60 Hz up to 3 HP or
208-230 V for 5 HP
• Three phase version, 2 pole: 208-230/460 V, 60 Hz up 75 HP
* Based on pump staging
Lenntech
PAGE 5
Goulds Pumps
Commercial Water
e-SV Characteristics
Optional Features
• Horizontal version • Tropicalized motors
• Special voltages, 50 Hz frequency • Premium E and explosion proof motors
• Special materials for the mechanical seal, gaskets and • 1750 RPM, 4 pole motors
elastomers • Passivation
Lenntech
PAGE 6
Goulds Pumps
Commercial Water
SERIES SVT SERIES SVF, SVN SERIES SVR SERIES SVP SERIES SVG, SVN
1SV, 3SV, 5SV, 1SV, 3SV, 5SV, 1SV, 3SV, 5SV, VICTAULIC 33SV, 46SV, 66SV,
10SV, 15SV, 22SV 10SV, 15SV, 22SV 10SV, 15SV, 22SV 1SV, 3SV, 5SV, 92SV, 125SV
10SV, 15SV, 22SV
e-SV Product Range 1SV 3SV 5SV 10SV 15SV 22SV 33SV 46SV 66SV 92SV 125SV
Nominal Flow (GPM) 9 15 30 50 80 110 150 220 350 450 600
Flow Range(GPM) 2-12 3-22 7-45 9-75 18-125 21-150 30-195 45-285 70-420 90-580 120-700
Max. Head (Ft) 860 1085 975 1150 1060 880 1125 1210 850 715 570
Max. Working Pressure (PSIG) 580 360/580
Temperature Range (°F) Standard -20°F - 250°F (-30°C - 121°C)
High Temp Option up to 300°F (150°C) –
Motor Power [HP] ½ – 5 HP ½ – 7½ ¾ – 10 ¾ – 20 2 – 25 3 – 30 3 – 60 7½ – 75 10 – 75 15 – 75 20 – 75
Max Pump Efficiency 51% 60% 70% 70% 70% 71% 76% 78% 78% 80% 79%
Materials of Construction
SVT 304 SS –
SVF 304 SS –
SVN 316L SS Cast Stainless Steel / 316L SS
SVR 304 SS –
SVP 316L SS –
SVC 316L SS –
SVG ASTM Class 35/40B Cast Iron / 304 SS
Connection Sizes
SVT - Oval NPT 1¼" 1¼" 1¼" 2" 2" 2" –
SVF - Round ANSI 1¼" 1¼" 1¼" 2" 2" 2"
–
Size/Class 300# 300# 300# 300# 300# 300#
SVN - Round ANSI 1¼" 1¼" 1¼" 2" 2" 2" 2½" 3" 4" 4" 5"
Size/Class 300# 300# 300# 300# 300# 300# 150/300# 150/300# 150/300# 150/300# 150/300#
SVR - Top/Bottom Round 1¼" 1¼" 1¼" 2" 2" 2"
–
ANSI Size/Class 300# 300# 300# 300# 300# 300#
SVP - Victaulic 1¼" 1¼" 1¼" 2" 2" 2" –
SVC - Clamp 1½" 1½" 1½" 2" 2" 2" –
SVG - Cast Iron 1¼" 1¼" 1¼" 2" 2" 2" 2½" 3" 4" 4" 5"
Size/Class 250# 250# 250# 250# 250# 250# 125/250# 125/250# 125/ 250# 125/ 250# 125/250#
Lenntech PAGE 7
Goulds Pumps
Commercial Water
Water Treatment
• Ultra iltration systems
• Reverse osmosis systems
• Water softeners and de-mineralization
• Distillation systems
• Filtration
Light Industry
• Washing and cleaning plants (washing and degreasing of
mechanical parts, car and truck wash tunnels, washing of
electronic industry circuits)
• Commercial washers
• Fire ighting system pumps
PAGE 8
Lenntech
Goulds Pumps
Commercial Water
Lenntech
PAGE 9
Goulds Pumps
Commercial Water
Lenntech
PAGE 10
Goulds Pumps
Commercial Water
Lenntech PAGE 11
Goulds Pumps
Commercial Water
PAGE 12 Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 13
Goulds Pumps
Commercial Water
F, G, P, R VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
Stainless Steel (F, P, R) AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
1 Pump Body
Cast Iron (G) ASTM Class 35/40B EN 1561 GJL 250 (JL1040)
2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
3 Diffuser Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
5 Shaft Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
6 Adapter Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
Aluminum (F, P, R) A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
7 Base
N/A (G) N/A N/A
8 Coupling Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
9 Seal Plate Stainless Steel AISI 316L EN 10088-1-X2-CrNi17-12-2 (1.4404)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
15 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
16 Wear Ring PPS
17 Seal Gland Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
N, P, C VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
EN 10088-1-X2-CrNiMo17-12-2
1 Pump Body Stainless Steel AISI 316L
(1.4404)
EN 10088-1-X2-CrNiMo17-12-2
2 Impeller Stainless Steel AISI 316L
(1.4404)
EN 10088-1-X2-CrNiMo17-12-2
3 Diffuser Stainless Steel AISI 316L
(1.4404)
EN 10088-1-X2-CrNiMo17-12-2
4 Casing Stainless Steel AISI 316L
(1.4404)
EN 10088-1-X2-CrNiMo17-12-2
5 Shaft Stainless Steel AISI 316
(1.4401)
6 Adapter Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
7 Base Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8 Coupling Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
9 Seal Plate Stainless Steel AISI 316L EN 10088-1-X2-CrNi17-12-2 (1.4404)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
EN 10088-1-X2-CrNiMo17-12-2
14 Fill/Drain Plugs Stainless Steel AISI 316
(1.4401)
15 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
16 Wear Ring PPS
EN 10088-1-X2-CrNiMo17-12-2
17 Seal Gland Stainless Steel AISI 316
(1.4401)
PAGE 14 Lenntech
Goulds Pumps
Commercial Water
SV G-N
45 36
6
8
11
44
13
29 9 18
41
3 3 18
49 15
16
46
19 48
12 LESS PISTON 34
5 10
4
38 2
30 30
24
20
21
47 28
31 23
35
26
18
37 18
39 27 14
27A
25 32 40
22 1 10
12
WITH PISTON
33
35 28
7 40
23
42
1
12 10
Lenntech PAGE 15
Goulds Pumps
Commercial Water
PAGE 16
Lenntech
Goulds Pumps
Commercial Water
SV G-N
Lenntech
PAGE 17
Goulds Pumps
Commercial Water
G VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
3 Diffuser Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
EN 10088-1-X2-CrNiMo17-12-2
4 Casing Stainless Steel AISI 316L
(1.4404)
EN 10088-1-X17-CrNiMoN22-5-3
5 Shaft Duplex Stainless Steel UNS S 31803
(1.4507)
Adapter (up to 40HP) Cast Iron ASTM Class 25 EN 1561-GJL-200 (JL1040)
6
Adapter (50HP and higher) ASTM Class A536 EN 1561-GJL-500-7 (JS1050)
7 Wear Ring PPS
Coupling (up to 40HP) Cast Iron A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8
Coupling (50HP and higher)
9-9A Upper Head / Seal Housing Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Bushing for Diffuser Carbon
EN 10088-1-X2-CrNiMo17-12-2
15 Fill/Drain Plugs Stainless Steel AISI 316
(1.4401)
16 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
17 Adapter Ring Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
N VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
2 Impeller Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
3 Diffuser Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
EN 10088-1-X17-CrNiMoN22-5-3
5 Shaft Duplex Stainless Steel UNS S 31803
(1.4507)
Adapter (up to 40HP) Cast Iron ASTM Class 25 EN 1561-GJL-200 (JL1040)
6
Adapter (50HP and higher) ASTM Class A536 EN 1561-GJL-500-7 (JS1050)
7 Wear Ring PPS
Coupling (up to 40HP) Cast Iron A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8
Coupling (50HP and higher)
9-9A Upper Head / Seal Housing Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Bushing for Diffuser Carbon
15 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
16 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
17 Adapter Ring Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
PAGE 18
Lenntech
Goulds Pumps
Commercial Water
1 – 22SV 33 – 125SV
Rotating Face Stationary Face Elastomers Spring Metal Components Elastomer Temp Seal Temp Max. Working
Pump Code Application
1 2 3 4 5 Limits °F (°C) Limits °F (°C) Pressure
1SV 0 Carbon -14 - 392°F General Service
Viton
3SV 2 Silicon Carbide (-10 - 200°C) 580 psi
Graphite Filled Silicon Carbide -22 - 250°F (40 bar) Abrasive
5SV 4 -30 - 300°F
EPR 316SS 316SS
10V 6 Carbon Graphite Filled (-34 - 150°C) General Service
15SV FDA Grade -14 - 392°F up to 340°F 255 psi
1 AFLAS Boiler Feed
22SV Carbon (-10 - 200°C) (171°C) (17.6 bar)
33SV 0 Carbon General Service
-14 - 392°F
46SV 2 Viton
Silicon Carbide Silicon Carbide (-10 - 200°C) -22 - 250°F 580 psi
66SV 316SS 316SS Abrasive
4 Graphite Filled Graphite Filled (-30 - 120°C) (40 bar)
92SV -22 - 250°F
EPR
125SV 6 Carbon (-30 - 120°C) General Service
Rotating Stationary
Elastomers Spring Sleeve Set Screw Locking
Pump Face Face Collar
1 2 3 4 5 6
33SV VENT 1⁄8 NPT
Carbon Viton
46SV Silicon
316SS 316SS 300SS 316SS
66SV Carbide Silicon
EPR VENT 1⁄8 NPT
92SV Carbide
7 5 4 3 2 1 3 3 PULLER
HOLES
6
CARTRIDGE SEAL
Lenntech PAGE 19
Goulds Pumps
Commercial Water
1SV-22SV
800
Standard
300
Limit
Seal
OVAL “T”
200
100
Viton
0
-20 -14
-50 0 50 100 150 200 250 300 350
TEMPERATURE (F)
33SV-92SV
800
700
MAXIMUM WORKING PRESSURE (PSIG)
400
Seal Limit
100
0
-20 -14
-50 0 50 100 150 200 250 300 350
TEMPERATURE (F)
Lenntech
PAGE 20
Goulds Pumps
Commercial Water
p1max ≤ PN - pmax
Lenntech PAGE 21
Goulds Pumps
Commercial Water
Motor Data
Lenntech
PAGE 22
Goulds Pumps
Commercial Water
Motor Data
Lenntech PAGE 23
Goulds Pumps
Commercial Water
Motor Data
PAGE 24
Lenntech
Goulds Pumps
Commercial Water
Motor Data
Lenntech PAGE 25
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
PAGE 26
Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 27
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
Lenntech PAGE 29
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
PAGE 30
Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 31
Goulds Pumps
Commercial Water
PAGE 32
Lenntech
Goulds Pumps
Commercial Water
TOTAL STAGES
20
10SV 60Hz
19 3500 RPM
18
17
16
15
14
13
12
11
10
9
8
7
6
3
2
Lenntech PAGE 33
Goulds Pumps
Commercial Water
Lenntech
PAGE 34
Goulds Pumps
Commercial Water
15SV 60Hz
TOTAL STAGES 3500 RPM
15
14
13
12
11
10
Lenntech PAGE 35
Goulds Pumps
Commercial Water
Lenntech
PAGE 36
Goulds Pumps
Commercial Water
TOTAL STAGES
22SV 60Hz
12 3500 RPM
11
10
8.66 L2
(220) 4.11
6.69 7.50 (104.5)
(170) (190.5)
7.50 (190.5)
Cast Iron 316SS
2½" Class 125 R.F. 2½" Class 150 R.F.
9.45 11.42
(240) (290) VENT FILL
1/2 BSP Ø 5.88 B.C.
1/2 BSP Ø 5.88 B.C. (149.3)
Ø .6 (15) (149.3) Ø .88 (22)
4 HOLES L1 Ø .88 (22) 8 HOLES
8 HOLES
3/8 3/8
NPT NPT
4.13
(105) 4.94 4.11
DRAIN 1/2 BSP (125.5) (104.5)
1.18 12.60 7.50 (190.5) 7.50 (190.5)
All dimensions are in inches (mm). (30) (320) Cast Iron 316SS
2½" Class 250 R.F. 2½" Class 300 R.F.
PAGE 38 Lenntech
Goulds Pumps
Commercial Water
0 10 20 30 40 50 Q [m3/h]
9
1000 9/1
300
9/2
900 8
8/1
8/2
250
800 7
7/2
700 6
6/1 200
6/2
600
5
5/1
5/2
500 150
4
4/1
400 4/2
3
3/1 100
300 3/2
2
200 2/1
2/2
50
1
100 1/1
0 0
6 80
Full Dia.
HP/STAGE
4 70
EFF [%]
2 60
Efficiency [%]
Reduced Dia.
0 50
40
NPSHr [METERS]
10
NPSHr [FEET]
30
8
20 6
4
10
2
0 0
0 25 50 75 100 125 150 175 200 225 250
Q [US GPM]
MINIMUM FLOW RATE: 35 GPM [8 m3/hr]
Lenntech PAGE 39
Goulds Pumps
Commercial Water
L2
9.45 8.25 5.00 (127)
(240) (209.5)
7.48 8.25 (209.5)
(190) Cast Iron 316SS
3" Class 125 R.F. 3" Class 150 R.F.
5.5
(140)
DRAIN 1/2 BSP
1.77 5.69
(45) 14.4 5.00 (127)
(365) (144.5)
8.25 (209.5) 8.25 (209.5)
All dimensions are in inches (mm). Cast Iron 316SS
3" Class 250 R.F. 3" Class 300 R.F.
PAGE 40
Lenntech
Goulds Pumps
Commercial Water
0 10 20 30 40 50 60 70 Q [m3/h]
9 350
9/1
1100 9/2
8
1000 8/1
300
8/2
900 7
TOTAL DYNAMIC HEAD [FEET]
5 200
5/1
600
5/2
4
500 4/1 150
4/2
400 3
3/1
3/2 100
300
2
2/1
200 2/2
50
1
100 1/1
0 0
80
8 Full Dia.
Efficiency [%]
HP/STAGE
7 70
EFF [%]
6 Reduced Dia.
60
5
4 50
20 6
NPSHr [METERS]
NPSHr [FEET]
16 5
12 4
3
8
2
4
0 50 100 150 200 250 300 350
Q [US GPM]
MINIMUM FLOW RATE: 40 GPM [9 m3/hr]
Lenntech PAGE 41
Goulds Pumps
Commercial Water
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19)
(265) (315) Ø 0.75 (19)
8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
5.5 6.94
(176.3) 6.18 (157)
(140)
10.00 (254) 10.00 (254)
DRAIN 1/2 BSP
1.77 Cast Iron 316SS
(45) 14.4
(365) 4" Class 250 R.F. 4" Class 300 R.F.
PAGE 42 Lenntech
Goulds Pumps
Commercial Water
0 20 40 60 80 100 Q [m3/h]
66SV 60 Hz
6 3500 RPM
TOTAL STAGES/REDUCED STAGES
6/1 250
800 6/2
5
700
5/1
5/2 200
4/1
4/2
500 150
400 3/1
3/2
100
300 2
2/1
2/2
200
50
1
1/1
100
0 0
14 80
Full Dia.
12
HP/STAGE
70
EFF %
10 Reduced Dia.
60
8
Efficiency [%]
6 50
12
NPSHr [METERS]
40
NPSHr [FEET]
10
30 8
20 6
4
10
2
0 0
0 50 100 150 200 250 300 350 400 450 500
Q [US GPM]
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19) Ø 0.75 (19)
(265) (315) 8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
PAGE 44 Lenntech
Goulds Pumps
Commercial Water
4
600 180
4/1
4/2
500
3 140
3/1
3/2
400 120
100
2
300
2/1
2/2 80
200 60
1
1/1 40
100
20
0 0
20 85
18 Full Dia. 80
16
HP/STAGE
75
EFF %
14 Reduced Dia. 70
12 65
10 60
8 Efficiency [%] 55
6 50
50
14
NPSHr [METERS]
40
NPSHr [FEET]
12
30 10
8
20 6
10 4
2
0 0
0 100 200 300 400 500 600 700
Q [US GPM]
MINIMUM FLOW RATE: 100 GPM [23 m3/hr]
Lenntech PAGE 45
Goulds Pumps
Commercial Water
Lenntech
PAGE 46
Goulds Pumps
Commercial Water
125SV 60Hz
3500 RPM
5/0C
5/5B
4/3B
3/3A
2/0C
1/0C
Lenntech PAGE 47
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
PAGE 48
Lenntech
Goulds Pumps
Commercial Water
TOTAL STAGES
1SV 60Hz
30 1750 RPM
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
Lenntech PAGE 49
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
Lenntech
3SV-30 34.53 10.79 9.91 9.16 9.29 34.53 26.26 33.55 33.55 5.19 6.19 6.19 6.19 6.19 4.13 53 27 29 21 21 80 82 74 74
PAGE 50
Goulds Pumps
Commercial Water
3SV 60Hz
TOTAL STAGES 1750 RPM
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
Lenntech PAGE 51
Goulds Pumps
Commercial Water
All
dimensions
are in inches
(mm).
PAGE 52
Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 53
Goulds Pumps
Commercial Water
PAGE 54
Lenntech
Goulds Pumps
Commercial Water
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Lenntech PAGE 55
Goulds Pumps
Commercial Water
Lenntech
PAGE 56
Goulds Pumps
Commercial Water
15SV 60Hz
1750 RPM
TOTAL STAGES
15
14
13
12
11
10
Lenntech PAGE 57
Goulds Pumps
Commercial Water
Lenntech
PAGE 58
Goulds Pumps
Commercial Water
22SV 60Hz
1750 RPM
TOTAL STAGES
12
11
10
Lenntech PAGE 59
Goulds Pumps
Commercial Water
8.66 L2
(220) 4.11
6.69 7.50 (104.5)
(170) (190.5)
7.50 (190.5)
Cast Iron 316SS
2½" Class 125 R.F. 2½" Class 150 R.F.
9.45 11.42
(240) (290) VENT FILL
1/2 BSP Ø 5.88 B.C. Ø 5.88 B.C.
1/2 BSP
(149.3) (149.3)
Ø .6 (15) Ø .88 (22)
4 HOLES L1 Ø .88 (22) 8 HOLES
8 HOLES
3/8 3/8
NPT NPT
4.13
(105) 4.94 4.11
DRAIN 1/2 BSP (125.5) (104.5)
1.18 12.60 7.50 (190.5) 7.50 (190.5)
(30) (320) Cast Iron 316SS
2½" Class 250 R.F. 2½" Class 300 R.F.
PAGE 60
Lenntech
Goulds Pumps
Commercial Water
0 5 10 15 20 25 Q [m3/h]
300
33SV 60 Hz 90
TOTAL STAGES/REDUCED STAGES 1750 RPM
10
10/1
10/2 80
9
9/1
9/2
70
8
8/1
8/2
200
60
7/2
6
50
6/1
6/2
5
5/1 40
5/2
4
4/1
100 4/2 30
20
2
1 10
0 0
1 80
.75
HP/STAGE
Full Dia. 70
EFF %
.5
60
.25
Efficiency [%]
Reduced Dia.
0 50
10 3
NPSHr [METERS]
NPSHr [FEET]
8
2
6
4
1
2
0 0
0 25 50 75 100 125
Q [US GPM]
MINIMUM FLOW RATE: 18 GPM [4 m3/hr]
Lenntech PAGE 61
Goulds Pumps
Commercial Water
L2
9.45 8.25 5.00 (127)
(240) (209.5)
7.48 8.25 (209.5)
(190) Cast Iron 316SS
3" Class 125 R.F. 3" Class 150 R.F.
10.43 12.40
(265) (315) VENT FILL
1/2 BSP 1/2 BSP
Ø 6.62 B.C. Ø 6.62 B.C.
(168.2) (168.2) Ø .88 (22)
Ø .6 (15) L1 Ø .88 (22) 8 HOLES
4 HOLES 3/8 3/8 8 HOLES
NPT NPT
5.5
(140)
DRAIN 1/2 BSP
1.77 5.69
(45)
14.4 5.00 (127)
(365) (144.5)
8.25 (209.5) 8.25 (209.5)
Cast Iron 316SS
All dimensions are in inches (mm). 3" Class 250 R.F. 3" Class 300 R.F.
PAGE 62
Lenntech
Goulds Pumps
Commercial Water
0 5 10 15 20 25 30 35 Q [m3/h]
350
46SV 60 Hz
1750 RPM 100
TOTAL STAGES/REDUCED STAGES
10
10/1
300 10/2 90
9
9/1
9/2
80
8
250 8/1
8/2
7
7/1
7/2
200 60
6
6/1
6/2
5 50
150 5/1
5/2
4 40
4/1
4/2
100 3 30
3/1
3/2
2 20
50
1 10
0 0
1.5 80
70
HP/STAGE
1 Full Dia.
EFF %
60
.5 Efficiency [%] Reduced Dia.
50
0 40
5
NPSHr [METERS]
NPSHr [FEET]
4 3
3
2
2
1
1
0 20 40 60 80 100 120 140 160 180
Q [US GPM]
MINIMUM FLOW RATE: 20 GPM [5 m3/hr]
Lenntech PAGE 63
Goulds Pumps
Commercial Water
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19) Ø 0.75 (19)
(265) (315) 8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
5.5 6.94
(176.3) 6.18 (157)
(140)
10.00 (254) 10.00 (254)
DRAIN 1/2 BSP
1.77 Cast Iron 316SS
(45) 14.4
(365) 4" Class 250 R.F. 4" Class 300 R.F.
PAGE 64
Lenntech
Goulds Pumps
Commercial Water
0 10 20 30 40 50 Q [m3/h]
250
66SV 60 Hz
TOTAL STAGES/REDUCED STAGES 1750 RPM
70
6
200 6/1
60
6/2
5
5/1
50
5/2
150
4
4/1 40
4/2
3
100 3/1 30
3/2
2
2/1 20
2/2
50
1
10
0 0
3 80
HP/STAGE
2 70
EFF %
Full Dia.
1 60
Reduced Dia.
Efficiency [%]
0 50
12
NPSHr [METERS]
10 3
NPSHr [FEET]
8
6 2
4
1
2
0 0
0 50 100 150 200 250
Q [US GPM]
MINIMUM FLOW RATE: 35 GPM [8 m3/hr]
Lenntech PAGE 65
Goulds Pumps
Commercial Water
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19) Ø 0.75 (19)
(265) (315) 8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
5.5 6.94
(140) (176.3) 6.18 (157)
10.00 (254) 10.00 (254)
DRAIN 1/2 BSP
1.77 Cast Iron 316SS
(45) 14.4
(365) 4" Class 250 R.F. 4" Class 300 R.F.
PAGE 66
Lenntech
Goulds Pumps
Commercial Water
0 10 20 30 40 50 60 70 80 Q [m3/h]
250
92SV 60 Hz
TOTAL STAGES/REDUCED STAGES 1750 RPM
6 70
6/1
6/2
200
60
5
5/1
5/2
50
4
150 4/1
4/2
40
3
3/1
3/2
100 30
2
2/1
2/2 20
50
1
1/1 10
0 0
3 80
Full Dia.
HP/STAGE
2 70
EFF %
Reduced Dia.
1 60
Efficiency [%]
0 50
20 6
NPSHr [METERS]
5
NPSHr [FEET]
4
10 3
2
1
0 0
0 100 200 300 400
Q [US GPM]
MINIMUM FLOW RATE: 50 GPM [11 m3/hr]
Lenntech PAGE 67
Goulds Pumps
Commercial Water
Lenntech
PAGE 68
Goulds Pumps
Commercial Water
125SV 60Hz
1750 RPM
8/0C
7/0C
6/6A
5/5A
4/0C
3/3A
2/0C
Lenntech
PAGE 69
Goulds Pumps
Commercial Water
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump coniguration. Use for mounting location only.
Lenntech
PAGE 70
Goulds Pumps
Commercial Water
Lenntech PAGE 71
Goulds Pumps
Commercial Water
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump coniguration. Use for mounting location only.
PAGE 72 Lenntech
Goulds Pumps
Commercial Water
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump coniguration. Use for mounting location only.
Lenntech PAGE 73
Goulds Pumps
Commercial Water
PAGE 74 Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 75
Goulds Pumps
Commercial Water
Lenntech
PAGE 76
Goulds Pumps
Commercial Water
Lenntech
PAGE 77
Goulds Pumps
Commercial Water
Lenntech
PAGE 78
Goulds Pumps
Commercial Water
Lenntech
PAGE 79
Goulds Pumps
Commercial Water
PAGE 80 Lenntech
Goulds Pumps
Commercial Water
Lenntech PAGE 81
Goulds Pumps
Commercial Water
Lenntech
PAGE 82
Goulds Pumps
Commercial Water
Lenntech
PAGE 83
Goulds Pumps
Commercial Water
PAGE 84
Lenntech
Goulds Pumps
Commercial Water
Lenntech
PAGE 85
Goulds Pumps
Commercial Water
PAGE 86
Lenntech
Goulds Pumps
Commercial Water
NPSH
The minimum operating values that can be reached at the The maximum possible suction head for installation de-
pump suction end are limited by the onset of cavitation. pends on the value of the atmospheric pressure (i.e. the
elevation above sea level at which the pump is installed)
Cavitation is the formation of vapor-filled cavities within
and the temperature of the liquid.
liquids where the pressure is locally reduced to a critical
value, or where the local pressure is equal to, or just below To help the user, with reference to water temperature
the vapor pressure of the liquid. (40ºF) and to the elevation above sea level, the following
tables show the drop in hydraulic pressure head in relation
The vapor-filled cavities flow with the current and when
to the elevation above sea level, and the suction loss in
they reach a higher pressure ares the vapor contained in
relation to temperature.
the cavities condenses. The cavities collide, generating
pressure waves that are transmitted to the walls. These, Water Temperature (ºF) 68 104 140 176 194 230 248
being subjected to stress cycles, gradually become de- Suction Loss (ft) -.7 2.3 6.6 16.4 24.3 50.5 70.5
formed and yield due to fatigue. This phenomenon, char-
acterized by a metallic noise produced by the hammering Elevation Above Sea Level (ft) 1600 3300 4900 6500 8200 9800
on the pipe walls, is called incipient cavitation. Suction Loss (ft) 1.8 3.6 5.4 7.2 9.0 10.8
The damage caused by cavitation may be magnified by To reduce it to a minimum, especially in cases of high suc-
electrochemical corrosion and a local rise in temperature tion head (over 13 – 16 feet) or within the operating limits
due to the plastic deformation of the walls. The materials with high flow rates, we recommend using a suction line
that offer the highest resistance to heat and corrosion are having a larger diameter than that of the pump’s suction
alloy steels, especially austenitic steel. The conditions that port. It is always a good idea to position the pump as close
trigger cavitation may be assessed by calculating the total as possible to the liquid to be pumped.
net suction head, referred to in technical literature with
the acronym NPSH (Net Positive Suction Head).
The NPSH represents the total energy (expressed in feet) of
the liquid measured at suction under conditions of incipi-
ent cavitation, excluding the vapor pressure (expressed in
feet) that the liquid has at the pump inlet.
To ind the static height (hz) at which to install the ma-
chine under safe conditions, the following formula must
be veriied:
hp + hz ≥ (NPSHr + 2 ft) + hf + hpv
where:
hp is the absolute pressure applied to the free liquid sur-
face in the suction tank, expressed in feet of liquid; hp
is the quotient between the barometric pressure and
the speciic weight of the liquid.
hz is the suction lift between the pump axis and the free
liquid surface in the suction tank, expressed in feet;
hz is negative when the liquid level is lower than the
pump axis.
hf is the flow resistance in the suction line and its acces-
sories, such as: ittings, foot valve, gate valve, elbows,
etc.
hpv is the vapor pressure of the liquid at the operating
temperature, expressed in feet of the liquid. hpv is
the quotient between the Pv vapor pressure and the
liquid‘s speciic weight.
0.5 is the safety factor.
Lenntech PAGE 87
Goulds Pumps
Commercial Water
info@lenntech.com
Lenntech www.lenntech.com
Tel. +31-152-610-900
PAGE 88
Fax. +31-152-616-289