You are on page 1of 1
GRACO PROTECTIVE COATINGS Et Airless Applicators Tip Selection Guide + Stondard RAC 5 Swithiips are back. + Fine Finch RAC (FS) Switch are green. + LinLazer RAC UL) Switehips ae yetlow. + Graco Heaw-Duty (GHO) RAC tps are gray RAC 5 SwitchTips (286XXX) ‘a. (mm) 007 009 011.013 015 097 019 021 023 QUIPMENT § APPLICATORS Making Sense of the Numbers Graco uses 2 unique numbering system forall airless spray tips. The first three characters designate the type of tip. For example, a 286417 is a RAC 5 SwitchTip™. The chart below shows other types. 286 RAC 5 SwitchTip 221 RACIV Switchiip FS Fine Finish RAC S SwitchTip 269 Contractor Flat Tip US LineLazer™ RAC 5 SwitchTip 163 Fine Finish and Siver Flat Tip GHD Heavy-Duty RAC SwitchTip Double the fourth digit forthe approximate fan width in inches when the gun is held 12 in (305 mm) from the surface. Example: 286417 has a fan width of approximately 8 in. (203 mm). Divide the last two digits by 1000 for the tip orifice size in inches. Example: 286417 has an orifice size of 0,017 in. (0.43 mm). Also, look at the RAC 5 chart below to determine the flow rate of a 017 tip. As indicated in the chart, tis tip has a flow rate of 0.31, or approximately 1/3 gpm (which is about 1.2 lpm). Orifice Size - Inches 025 .027 .028 081 083 085 038 .043 048 051 055 068 .065 ze ging [fue fm fns [nsf [ra] 2 45 ice [a7 foo Jann [ais ais [air ig | 22 [228 | 8 28 54 (seat 307 [30 fair ta fas [37 faa faz | 23 | 25 [sar | fae a Bsn owas] [aoa {errata | ans [ar7| a 1 [123 25 [or | a] Pasa as faa | wa far fas sora sens) | {50a |st1 | taf ss sr a | sat [5 sm [sar | se0 fat fsa a5 [Seo] set | 1214 sae [Jom fort [a {1s | 7] 1921 2 | | st | 653 5 we] fess] | as © ics sea) | trai |re 3 78 16:8 (6467) cs [a7 aia fat el [ast | asa as 18.2 (6750) a 5 Fw rate gpm) 5 | 08 | 2 | 18 | 26 | st [58 ar | sr far | rr | oo |r| vat faa ig 217 | 279] 325] 26] asa ow rate Com) |20 | | 0 {50 | 1 fixr|iar|iza2ns|2s4| 2963.42 }390]4 cl 498 [61a] 731 | 62a asi teza tl 37 (ser @ 2000s 13.8 Pa, 128) ‘rape trap wit @ TT (28 mn) oe anda Ta SRR) pao Or TEST Fan wih of 0 sry pater metsred 12 (305 rn) hn he sure Fine Finish RAC 5 SwitchTips (FF5XXX) LineLazer RAC 5 SwitchTips (LL5XXX) Orifice Size - Inches ‘Orifice ize - inches i twm [ovolorlond in. (wm) |ors}015]017]019|021]023] 025] 027] 05 46 (o2se)[a0 [ie] 2 2 on [asfas [arf so2 e305) [510 [1254 #2 cos xt [os | [wr 124 @05-356){_ [612 [er row rate oom {| 2 [i | 8 | ar | sr | | 7 [325 ow rat gpm [15 [21 wate fom) [23 [st [us fra [v9 2s [ase ow ate tom [3 | 0 utr 0098 18 a a) (ve 200 1.8 MPa 38 ‘camper op with @ 0075 (238 am) oles and a 4h. (02m) samp or 2p wih « 0070 h (025 mm) alice ond @ 10m (254 mm) pate, order FFSS10. from the srloce Fon width of sprey pater is measured ot 12 (505 mm) pate, order US5I5. Fan wih of srey pater is measured 6 in (152 mm) fromthe surface wth alc point 2000 psi (158 MPa 158 bo)

You might also like