You are on page 1of 3

OFFSHORE TESTING & INSPECTION SERVICES (I) PVT. LTD.

(AN ISO 9001:2015 CERTIFIED, ISO/IEC 17025:2005 ACCREDITED& BIS RECOGNISED LAB)
W-147, M.I.D.C., PAWANE, THANE BELAPUR ROAD, NAVI MUMBAI - 400710.
TEL.: 41411414 . FAX: 2763 3982 . E-mail: info@otislab.com . www.otislab.com Certificate No.TC-7643

TEST C E R TIFIC A TE
QR/OTIS/TC/Ol, R ev.02

M/s SPARKLE CLEANTECH PVT. LTD. ULR-TC768319000003381P


C/o. Subhash Silk Mills Ltd.,At.-Sajgaon, DATE OF COMPLETION : 24-10-2019
Khopoli-Pen Road, Khopoli, Tal.-Khalapur,
Dlst.-Ralgad, Maharashtra.
DESCRIPTION : Testing of CS Plate Cut Test Ref..: Ch. No : F179/2019-20
Piece Sample Dated: 16-10-2019
STAMP/SIGNED BY: — No. of Samples : 1
Sample Drawn By : Party Test Compliance:--
Sample Received on: 18-10-2019 Material Specification : IS 2062 (2011) Grade E250A
Project Title: Waste Water Treatment Proj. CORRESPONDING LAB Sr. No. Page 1 of 3
Tag No.: MPT-Z-942 MR/19/01/02/12028-1
Size 300.0mm x 300.0mm x 25.00mm Thk
Heat No. SP-P-001

I.CHEMICAL TESTING
ljMetals & Alloys
CHEMICAL ANALYSIS Test Method : ASTM E 415:2017 Date of Performance : 23-10-2019
Observed Value Reqd. Value
Carbon(C)% 0.15 0.23 Max.
Silicon (Si)% 0.16 0.40 Max.
Manganese (Mn)% 0.63 1.50 Max.
Phosphorus(P)% 0.018 0.045 Max.
Sulphur (S)% 0.013 0.045 Max.
Chromium (Cr)% 0.10 -
Nickel (Ni)% 0.10 -
Molybdenum (Mo)% 0.002# -
Copper(Cu)% 0.011 -
Vanadium (V)% 0.001# -
Carbon Equivalent (C.E.)% 0.28 0.42 Max.
Remark Satisfactory
Remarks: Above sample meets the requirements of IS 2062 (2011) Grade E250A specification with
respect to elements analysed.

fv y V g g C --
Checked By Authorised By
RENU MISHRA
(CHEMICAL DEPT.)

Continued on next page.


OFFSHORE TESTING & INSPECTION SERVICES (I) PVT. LTD.
(AN ISO 9001:2015 CERTIFIED, ISO/IEC 17025:2005 ACCREDITED& BIS RECOGNISED LAB)
W-147, M.I.D.C., PAWANE, THANE BELAPUR ROAD, NAVI MUMBAI - 400710.
TEL.: 41411414 . FAX: 2763 3982 . E-mail: info@otislab.com . www.otislab.com Certificate No.TC-7643

TEST C E R TIFIC A TE
QR/OTIS/TC/Ol, Rev.02

M/s SPARKLE CLEANTECH PVT. LTD. ULR-TC768319000003381P


C/o. Subhash Silk Mills Ltd.,At.-Sajgaon, DATE OF COMPLETION : 24-10-2019
Khopoli-Pen Road, Khopoli, Tal.-Khalapur,
Dist.-Raigad, Maharashtra.
DESCRIPTION : Testing of CS Plate Cut Test Ref..: Ch. No : F179/2019-20
Piece Sample Dated: 16-10-2019
STAMP/SIGNED BY: — No. of Samples : 1
Sample Drawn By : Party Test Compliance:--
Sample Received on: 18-10-2019 Material Specification : IS 2062 (2011) Grade E250A
Project Title: Waste Water Treatment Proj. CORRESPONDING LAB Sr. No. Page 2 of 3
Tag No.: MPT-Z-942 MR/19/01/02/12028-1
Size 300.0mm x 300.0mm x 25.00mm Thk
Heat No. SP-P-001
II.MECHANICAL TESTING
l)Mechanical Properties of Metals
Tensile Test Test Method : IS 1608:2005 (Reapp.2012) Date of Performance : 23-10-2019
(Equipment Sr. No. 2011/47 Cal. Dt: 03-Qct-2019 Due Dt.: 02-Qct-2020)______________________________
Observed Value Reqd. Value
Specimen T1 T2
Gauge Dia. (mm) 14.09 14.08
Area (mm2) 155.92 155.70
Gauge Length (mm) 70.00 70.00
Yield Load (N) 39750 42000
Ultimate Load (N) 66500 67250
Final Gauge Length (mm) 93.60 93.18
Yield Strength (N/mm2) 254.93 269.74 240 Min.
U.T.S (N/mm2) 426.49 431.91 410 Min.
Elongation (%) 33.71 33.11 23 Min.
Fracture WGL WGL
Remark. Satisfactory Satisfactory
Remarks: Tensile test meets the requirements of IS 2062 (2011) Grade E250A specification with
respect to test carried out.___________________________________________________________

Checked By Authorised By
REEVA MORE
(MECHANICAL DEPT.)

Continued on next page..


OFFSHORE TESTING & INSPECTION SERVICES (I) PVT. LTD.
(AN ISO 9001:2015 CERTIFIED, ISO/IEC 17025:2005 ACCREDITED& BIS RECOGNISED LAB)
W-147, M.I.D.C., PAWANE, THANE BELAPUR ROAD, NAVI MUMBAI - 400710.
TEL.: 41411414. FAX: 2763 3982 . E-mail: info@otislab.com . www.otislab.com
Certificate No.TC-7683

TEST C E R TIFIC A TE
QR/QTIS/TC/01, R ev.02

M/s SPARKLE CLEANTECH PVT. LTD. ULR-TC768319000003381P


C/o. Subhash Silk Mills Ltd.,At.-Sajgaon, DATE OF COMPLETION : 24-10-2019
Khopoli-Pen Road, Khopoli, Tal.-Khalapur,
Dist.-Raigad, Maharashtra.
DESCRIPTION : Testing of CS Plate Cut Test Ref..: Ch. No : F179/2019-20
Piece Sample Dated: 16-10-2019
STAMP/SIGNED BY: — No. of Samples : 1
Sample Drawn By : Party Test Compliance:--
Sample Received on: 18-10-2019 Material Specification : IS 2062 (2011) Grade E250A
Project Title: Waste Water Treatment Proj. CORRESPONDING LAB Sr. No. Page 3 of 3
Tag No.: MPT-Z-942 MR/19/01/02/12028-1
Size 300.0mm x 300.0mm x 25.00mm Thk
Heat No, SP-P-001
Bend Test Test Method : IS 1599:1985 (Reapp.2012) Date of Performance : 23-10-2019
(Equipment Sr. No. 2011/47 Cal. Dt: 03-0ct-2019 Due Dt.: 02-0ct-2020)
Observed Value
Specimen Thickness mm 25.12
Specimen Width mm 40.00
Bend Degree 180°
Former dia mm 50.00
Bend 1 Satisfactory
Bend 2 Satisfactory
Remarks. Satisfactory
Remarks: Bend test meets the requirements of IS 2062 (2011) Grade E250A specification with
respect to test carried out.

Checked By lorised By
REEVA MORE
(MECHANICAL DEPT.)

Note: The result pertains to the above sample tested.


# Indicates range & elements does not covered under NABL scope.
Test certificate shall not be reproduced except in full, without written approval of the laboratory.
OTIS has made best endeavour/efforts to provide accurate & reliable information. OTIS shall not however be responsible for any consequential
loss owing to any inadvertent error/omissions.
End of Report------