Standard vALP '( LG Tg} Steam sterilizer With vacuum pump~drying AUTOCLAVE [emen)'/= Laboratory use 100~140°C, 542------ CLG-32L «-LDVPmodels 100~137°C, 852° CLG-40Ma-MDVPmodels 100~137°C, 1052 °°" CLG-40L «-LDVPmodels cLa-32L 4 4% cLa-4ompve Conversation style operation on LCD screen With multi-functions and more safety ! Selah * Lid Interlock By the central lock lever. you can easily lock the lid with fingertip. The lid is interlocked reliably during operation and cooling down to the safe temperature. % Upward Opening Lid The lid is lightened up and down by the automatic hinge, Electro Mechanical Lock This function brings more safety to operator by locking the lid at the power failure or in the power OFF, to prevent operator from contamination by contacting un-sterilized objects carelessly. Locking is released only on standby state in the power ON. LCD Display of Conversation style LCD screen shows set data of temperature, pressure, program and error messages at all stages of the operation process. Also, magnified data of operation temperature and time can be shown by flip-key on the display. Operation is easy conversation style by the key. Usual operation!&(16-~ DVP)programs are memorized by pattern and data, *& Precise Combined Control by Temperature and Pressure for Saturated Steam Pulse air purging is repeated until achieving suturated steam when pressure is high compared with temperature. Also, another air exhaust system controlled only by temperature-time can be selected for simple objects. This enables to shorten the sterilization total time compared with by pulse air purging. > Front loading Exhaust Bottle (for CLG models) The exhaust bottle is provided on the front for easy loading and checking. * Cooling Fan as standard The rapid cooling fan is provided for ell models. The autoclave can be perfomed in shorter time to sate temperature below 80°. %*& Warming & Dissolving of Culture Medium Warming after sterilization, and dissolving cold hardened culture medium, * Start-Timer by Calender You can set operation start by month, day, hour and minute. The sterilized objects can be taken out at your work-start. %* Temperature Sensor Entry Port as standard One additional sensor port is provided as standard on the inner lid. %& Pre-Vacuum(-DVP models) The triple pulse, pre-vacuum phase by the powerful vacuum pump with a spinning water ring, removes forcibly all the remained alr from the chamber and abjects, allowing good penetration of saturated steam into the objects, thus ensuring fully effective sterilization, %& Vacuum Drying(-DVP models) After sterilization, the objects with wet by steam can be dried clearly and cleanly by the vacuum pump and drying heater through 0.24m micro pre-filter. [QIWARERIOB TIONED (on ot your order-unabie to be eaubed later) D Automatic water Supply with Pre-heating In stead of troublesome check and manuel supply of water batfore operation, proper quantity of water is automatically supplied from city water faucet. And to shorten the heating-up time after start. water in the chamber is always kept near boiling condition. u Exhaust Air Filter---O.24m PTFE membrane filter in SUS304 housing For safety of operators and the environment, this ensures sterilization with safe air exhaust free from high’ infectious pathogenes. (This does not apply to -DVP models.) DB Recorder ; For GMP, a hybrid recorder can record 2~S points of temperatures and 1 pressure in ‘the chamber by temperature sensors and pressure sensor. Record (SEALER GE TIGNY cabic to be equiped tater) Object temp.operation 7 : Dobject Temperature Sensor Contr ae sere) Chases Cherba S| An abject temperature sensor placed in the cold spot of objects gives better sterilization. The timer starts only after the temperature measured by this sensor reaches the set tomperature. Also, by this sensor equipment, unlocking temperature of the lid interlock can be changed in the range 80C~ Start Ster.time ‘Completion 98°. This realizes both of ster stion-reliability and reduction of sterilization total time simultaneously. When this sensor Is not used, it can be put in the ‘holder of inner lid as photo of left page. Derinter It prints the set data, 2 temperatures of the control sensor and the object sensor, and pressure, in every | minute (variable) “Printer and RS-282C cannot be equiped at the same time, Serial Communication Port RS-232C Wana Data Logging System — ALP-LOGGER — By RS-2920 interface and support soft"ALP-LOGG rs-2ae0 ER’. data of temperature-time, chamber pressure, operation process and abnormal warning are transmitted to PC to back up daily sterilization management. Straged data can be put cut as temperature - time graph or can be processed by Microsoft Excel®. A wiring cable between RS-232C and USB is provided as accessory. measured date Windows PC Autoclave (CLG series) OPERATION PANEL Easy friendly LCD screen ‘The LCD display provides all data of setting and operation. ‘The LCD display shows the present operation process stage by blinking ber. ‘The fault messages are displayed on the LCD screen. i te Geass PRO Power key Operation key I Magnitying display Wao Key functions ‘Switching by the flip key Pressure gauge @:20 GPERATIONRATTERNS! The folowing aisplay shows pressure on patterns. CLG series SOLIDS WASTE! ‘Ar exraust(Pulse/Time eystem) ~ Heating eM orlzaton = inaust + San LgUIB*6LOSED" Air oxraust - Heating -- Stor Natural coating (Erhavst adustabe) (Warming selectable) LiguIB*OPENED" ‘lr exraust(Pulse/Time system) — Heating ~ ‘Sterzaton = Exhaust ~ Fan (Warming coe actable) DissOLUTION ee Heating ~ Warming CLG-DVP series ‘SOLIDS-CLOTHES Pre vacuum ~ Heating ~ Sterzation ~ Drain Vasaum drying (Aaaitonalarving avalable) ‘SOLIDS-WASTE Pre vacuum ~ Heating ~ Sterlzation exhaust + Fan LiqUib*6LOSED" ‘lr exhaust - Heating ~ Stel, ~ Natural cootng (Exhaust adustabe) ~ (Warming selectable) LIQUIB*OPENED" Pre varuum - Heating » Strization "Exnavst + Fan» (Warming selectable) DisgOLUTION! rr Heating ~ Warming (Unit(me)) cLe-s2t © cL6-4om “40L (WUnit(me)) cL6-4omovP “40LDVP TOMI Round flasks Dimension 200mi 300mi 300mi cLc-40 stainless wire basket in cus-32 stainless wire basket ‘SPECIFICATIONS Vertical Autoctaves CLG/CLG:DVP series oan | S=0HardSteriizaton oni LG-32L, ‘CLG-40m LG-40L ] Prewacuu=Vacwn érvng ‘CLG-32LDVP ‘CLG-40MDVP. (CLG-40LDVP Chanber(Usabe ner da x det) 4320x676m 400x672 (2400x832 aacity (ters 540 352 1052 ‘Operating | Sterlizatin 700~1408 700-1378 temperature | Dissolution / Waring Dissolution: 40-99, Warming = 40~600 axinum operating pressure oR7oNPa 0.250NPa ‘Stritzatin/Dissoluton/ Warm tne Siriization/Dissolution = Omin~#8hr. OOmin & continuous). Warming : Onin ~48hrs 00min ‘Ai exhaust system ‘raviy subst ‘Pulse a purge by tenn. & res. sensing or Timed fee steaming Tie: astbll. eectable ‘Operation language English Hererized preerams 15C16-DVP) programs avaiable by operation pater and data Vacuum pump Wator sealed vacuum pump Q Pre-vacuum Tile pulse vacuum system 3 Vacuum deine ‘Aianate operation of vacuum and suction, or continuous vacuum aperation 2 Heating method Electrically heated chamber outside, & | Drying temperature range ‘60 to 150 co Devin tine in ~T0Ohrs OORT, Svetion ai iter ‘Zum micro caries titer ‘Start tiner “le to 361 operation star by calendar month day hour and minute. Drain valve (GLE modes: Marval value, CLG-DVP models: Aulomatc valve & manual valve = [Bute water supa ‘Automatic water supply system from eity-water-favcet by level sensor & controller 2 Pretest ssten “To shorten the come-up ime, 40~750. Provided only with autowater supoly Exhaust after PIFE membrane fit (Bore 0.2m) in starless housing on front over panel Ud interook system, Electro mechanical lock sytem. Double cheok system oid lose, Over pressure dete. Safety deviees ‘Over tomperature detectr, Water lack preventor. Sensor break indicator. Abnormal time iat. Memory of power fare, Safety valve, Breaker for slghtleakage, over curent & short ort : Safety valve 0.280MPa o2ToMPa Hares test oseNPa oa98NPa Pressure use eS =01~0.6MPa Pressure sensor =0.1~0.5MPa Hateral of chamber 308804 Stainross stool Material of enclosure ‘Steel wth melanin resn/Heat resistant lasts Power rearement ‘AC220/230/240V. Single phase. 50/60H2 2A T 8A Serentratng 15A iA Heat autut 26/2 8/2980 4074.18 Se '50x550x990m/65ke | 620x650%1000m/83kE ‘G20x650x1160m/89K6 | Cuter cimensions WADXHIWeIEN | 5506609903 /IOOKE {620% 760X1000m/127AE '620*TGOXt160R/IS3KE Suary_ | Staress wre vanxer | #300%500m.2oes. | _ #9803000, 2005 #380x400m. 2008. | acessores Oatin fr-DVP model ‘Others Exhaust botle(CLG models). Orain hose & water supply hose(G.6-DVP models) Ostlonal accessories ‘Object Temperature sensor. Printer or RS-2320. Recorder Baskel with pan, Bucket, Dressing dum ‘@Sovsiioavons on lah bu shows GLO models, and yetbw shows CLO-DVP modes, @Spesiestons sect to change wrhou ote for proven STANDARD / OPTIONAL ACCESSORIES: Stainless wire basket 4 6-4 wc eZ For standard CLG models, 2 baskets are equived as standard accessories. Stainless bucket Stainless Basket with pan - dressing drum forCLG32L forCLG-4OM/ for CLO-32L. for LOAOMM for cLe-a21 forctes2t ¢900%200m $380x200m ——«#$270x400m 6370x4000 $270%2700 $270%1808 $200200m $3goxaoom ——«27OXGDOMm —37OxC00m aaa Sano coo econ As ALP & Co.,Ltd. — ALP 2.3.10, Mdogats, Hamre Tok 25-08% sawn Ermalt apcoawonderocn ein ter 2017 URL hipaa al

You might also like