# TPEB-QHSE-F-01
ISSUE# 01
IN-PROCESS ASSEMBLY INSPECTION CHECK LIST
ISSUE DATE 05-06-2017
#2 4 MAN (A TO F)
ITE
M ACCEPTANCE CRITERIA Reference PASS FAIL N/A REMARKS
NO.
D: Roofing Assembly
The roof LGS frame shall be constructed of minimum 150 x 41 x 1 mm GI sections TPEB- SPR-
D1
designed to support. 10
TPEB- SPR-
D2 The roofing shall be designed with a minimum slope of 10%.
10
The roof shall be covered with minimum 0.5 mm thick pre-painted corrugated roofing
metal sheet cladding. The cladding shall be screwed directly to the roof structure. All TPEB- SPR-
D3
trims provided for inward and outward corners, bottom & top shall match the exterior 10
cladding
All roofing shall be insulated with 100mm fiberglass blanket insulation with R-value TPEB- SPR-
D4
of ( R-16) 10
REMARKS:
ISSUE# 01
IN-PROCESS ASSEMBLY INSPECTION CHECK LIST
ISSUE DATE 05-06-2017