Professional Documents
Culture Documents
2 019 I
2019 I LG HVAC SOLUTION
LG Electronics Distributed by
http://www.lg.com
http://partner.lge.com
MULTI V 5 022 WALL MOUNTED UNIT 094 HYDRO KIT 148 ERV 154 INDIVIDUAL CONTROL 166 MECHANICAL ACCESSORIES 216
MULTI V S 048 CEILING MOUNTED CASSETTE 104 ERV WITH DX COIL 160 CENTRALIZED CONTROL 174 PIPING ACCESSORIES 224
MULTI V M 060 CEILING CONCEALED DUCT 118 INTEGRATION DEVICE 186
MULTI V WATER IV 066 FRESH AIR INTAKE UNIT 130
(HEAT PUMP / HEAT RECOVERY)
CEILING & FLOOR CONVERTIBLE UNIT 132
MULTI V WATER S 088 CEILING SUSPENDED UNIT
COMPATIBILITY 142
002 003
WHY LG MULTI V
2017 ~
2010 · Eurovent Certification · Large Capacity ODU LG has set up 20 official air condition- Committed to meet all requirements LG’s European Air Conditioning Distribu-
· Active Refrigerant with Biomimetics ing academies in Europe, teaching much regarding energy efficiency and environ- tion Center is located in Oosterhout, the
Control Technology Fan needed skills to thousands of current mental demands, LG has invested in its Netherlands. Supplying and delivering
· High Pressure Oil Return · Variable Heat Exchanger industry professionals including install- own testing facility named the LG Energy products all over Europe, this distribution
2008 · Ocean Black Fin
· Vapor Injection Circuit ers, consultants, designers, sales staff Lab. LG Energy Lab is an innovative site hub has contributed to smooth and rapid
· Continuous Heating · Smart Load Control
and service technicians. The academy dedicated to commercial and residential delivery, direct shipping for smaller orders
program is being used to share expertise products for heating, ventilation and the and delivery tailored to air conditioners.
2006 · Ø7.0 Wide louver · Smart Oil Return
and educate these HVAC experts by latest energy efficient air conditioning The hub tries to manage inventory ef-
· LGDC Inverter · Vapor Injection
providing a cutting-edge technical ex- solutions. Also as a showcase, LG Ener- ficiency by taking advantage of LG EU’s
(Advanced)
perience with the newest and most ad- gy Lab is equipped with complete mon- established inventory pool.
· Heat Recovery
vanced technologies and equipments. itoring and control systems. The perfor-
· Ø7.0 Corrugate Moreover, as LG’s entire product range mance of all products will be tracked and
· Fuzzy Algorithm is installed on site, professionals can be analyzed by a team of Research and De-
· AC Inverter trained in a realistic way that offers them velopment engineers based in France and
· R410A the chance to experience the latest prod- Korea, ensuring efficiency and reliability
ucts first-hand. during the whole product lifecycle.
From the moment when LG introduced Korea’s first residential Moreover, Multi V’s wide range of VRF line-up satisfies various
air conditioner in 1968, the company has continuously types and sizes of buildings; MULTI V S is the VRF with side Air Conditioning Academy
enhanced its technological innovation and credibility. As a discharge, designed for small to mid-sized building and MULTI
result of sustained improvement, LG VRF launched the first V WATER is the water-cooled VRF solution with variable water Europe Energy Lab
generation of MULTI V in 2006 and achieved significant flow controlling technology.
development. With world’s top class compressor and European Distribution Center
innovative technology competency applied on every part, In 2017, the time has arrived for the ultimate VRF system,
cycle and controlling solutions, it has evolved to be one of the MULTI V 5. This generation has fully improved its technological
world’s most efficient and reliable VRF solutions. potential with ever powerful and reliable yet economical
LG’s Ultimate Inverter Compressor, Ocean Black Fin with
Following the first and second generations with Inverter the most effective corrosion resistance performance and
technology and non-ozone depleting refrigerant, MULTI V III has biomimetics technology-applied, enlarged fans. At the same
advanced its efficiency with diverse cutting-edge technologies time, the Dual Sensing Control offers users the most pleasant
such as HiPORTM that directly returns oil to compressor and environment while minimizing the unnecessary energy loss
Vapor Injection that allows double compression by adding with system that senses both the temperature and humidity to
mid-pressure refrigerant. The innovative technologies of efficiently manage cooling, heating and part load operations.
4th generation Multi V secured MULTI V brand with product
leadership based on efficient system. For example, Smart Load With MULTI V 5 that has been solely designed for the ultimate
Control that controls operational load according to external efficiency, performance, flexibility, comfort and control, we are
temperature. The other technology is optimized to manage highly confident to bring the ultimate pleasant air experience.
refrigerant and heat exchange for cooling or heating.
004 005
WHY LG MULTI V
03 Model Selection
I II III LATS HVAC
LATS HVAC is an integrated model selection program of LG HVAC products, enabling
Energy Estimation Model Selection Installation an accurate and quick selection on the best model suitable to each sites. In addition
& Energy Modeling & Design Environment to model selection, faster estimation on refrigerant piping diameter and additional
Simulation refrigerant is possible, along with auto printing of reports.
04 Design
01 Planning LATS CAD
LATS CAD enables faster and more accurate 2D design of LG HVAC products.
LATS It also enables modules for quotation and installation review that minimize
ENERGY inherent problems appearing during installation.
* AutoCAD program is required.
02 Schematic Design
LATS Revit
LATS
LATS REVIT is developed to make 3D design of LG HVAC products.
HVAC * AutoCAD Revit program is required.
03 Design Development
Energy
Modeling LATS CAD
- eQUEST Ⓡ LATS REVIT
- TRNSYS
05 Environment Simulation
CFD
04 Construction Design - FLUENT CFD Analysis
CFD Analysis is applied in areas of estimating: indoor airflow and temperature
distribution while operating VRF products, outdoor airflow distribution, and noise
level. By running a simulation before construction, engineers estimate possible
issues and find optimal solutions of malfunction that could occur after construction.
05 Construction
006 007
WHY LG MULTI V
BENEFITS OF LG MULTI V
* Dual Smart Load Control ESEER based, below 50% humidity, model ARUM260LTE5
** LG internal test result
008 009
WHY LG MULTI V
APPLICATION SOLUTIONS
Office Supporting efficiency with flexibility Residential Home is where your comfort is
High Rise Office Building Small to Medium sized Office Building Condominium & Apartments Single Family House & Villa
• MULTI V WATER IV • High Static Duct • Variable water flow • MULTI V S HR • 1/2 Way CST
• MULTI V 5 / S • 4 Way CST • PDI • MULTI V S • Therma V • ESS & PV Solar
• DX AHU • PDI control kit • Hydro Kit • 3rd party controller RTU gateway
MULTI V series vitalizes the workspace with fresh air at all time, combined with its various indoor selection. The intelligent Remarkably compact size and high static pressure of MULTI V S enables optimal space solution, providing comfort to every
control solutions add comfort to the space. space through individual zone control and hot water solution.
Commercial Maximize business, minimize costs Hospitality Meeting diverse needs in every aspect
The highly efficient, energy saving MULTI V 5 and MULTI V M reduces operation costs, and provides comfort that suits any The diverse applications that can be applied to MULTI V 5 helps bring just the right solution to a sophisticated hotel business.
purpose and any space, helping to invest the extra space and expense to your business.
* CST : Cassette * PDI : Power Distribution Indicator * ESS : Energy Storage System * PV : Photovoltaics
010 011
WHY LG MULTI V
Cooling
Outdoor Unit
70% Pump Lighting Fan Sensor
BMS Protocol
BMS System
AHU
012 013
LINE-UP
● ● ●
● ● ● ● ● ● ●
• Dual sensing control
• Large capacity ODU (Up to 26HP)
• Continuous Heating
• Ocean black fin heat exchanger
MULTI V 5 • Ability to function as HP or HR ● ● ● ● ● ● ● ● ● ● ● ● ● ●
• Flexible installation with
heat recovery unit and large capacity
• For large space, high rise building and
individual control building
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
○ ○
• Saves floor space
• Flexible design applications
- Slim, light and wide line up
MULTI V S (4 ~ 12HP) ● ○● ○●
- Combination of indoor unit
(Up to 20 Units)
• For Small / Medium building
● ● ●
MULTI V S
Heat ○
Recovery
● ● ● ●
● ● ● ● ● ●
• Compact size
MULTI V • Light weight
○
WATER S • For Residential and Commercial
building
● 380V, 3Ø ○ 220V, 1Ø
014 015
LINE-UP
Artcool Gallery ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
Wall
Artcool Mirror ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Mounted
Unit
Standard ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4 Way Cassette
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(570 x 570)
4 Way Cassette
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(840 x 840)
4 generation
th
2 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
1 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Mid /
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
High Statics
4 generation
th
Ceiling
Low Statics ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Concealed
Duct
High Sensible ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Fresh Air Intake Units
4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ceiling & Floor Convertible Unit
4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ceiling Suspended Unit
4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Console
Low Temperature ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
HYDRO KIT
High Temperature ● ● ● ● ● ● ● ● ● ● ● ● ●
1) If 4th generation indoor units are connected to MULTI V WATER S, several funtions are not available.
2) If 4th generation indoor units are combined to 2nd generation indoor units, several funtions are not available.
More detailed information, refer to the "MULTI V Indoor units Compatibility Table"
016 017
LINE-UP
PREMTB100 PQRCVCL0QW PQWRHQ0FDB PQCSZ250S0 PACP5A000 PLNWKB000 Premium (8 port) Simple Dry Contact PZCWRCG3 For MULTI V 5 Return/Room Air control
(Indoor Unit ~32) (Indoor Unit ~256) (Indoor Unit ~64) PQNUD1S40 PDRYCB000 PVDSMN000 PAHCMR000
Standard (2 port)
PPWRDB000
Wi-Fi Controller
ACS IO Module Variable Water Flow
Standard III (Black) LG Wi-Fi Modem AC Ez Touch AC Manager 5 Modbus RTU Gateway (Input / Output Module) Remote Temperature Sensor Control kit
PEXPMB000 Dry Contact for Thermostat PQRSTA0 For MULTI V WATER IV Discharge Air control
PREMTBB10 PQRCVCL0Q For Indoor Unit PACEZA000 PACM5A000 PMBUSB00A PDRYCB300 PWFCKN000 PAHCMS000
PWFMDD200 (Indoor Unit ~64) (Indoor Unit ~8,192)
PREMTB001 PQRCHCA0QW PACS5A000 LG-AC-KNX4 PCHILLN000 2 Points Dry Contact ZRTBS01 For MULTI V IV, 5 PRCKD21E (~ 4 ODUs)
(Simple for Hotel) (Indoor Unit ~128) LG-AC-KNX8 (For Setback) PRVC2 PRCKD41E (~ 8 ODUs)
LG-AC-KNX16 PDRYCB400
LG-AC-KNX64
ACU IO Module
Standard II (Black) PI-485 EEV Kit
NEW UIO Zone Controller Cool / Heat Selector (Electronic Expansion Valve)
Premium
TXV Kit
NEW UO (Thermal Expansion Valve)
PEXPM100
Note
1. AC Smart 5 & ACP 5 provides BACnet IP / Modbus TCP
2. KNX Gateway is provided by INTESIS
018 019
OUTDOOR
UNITS
OUTDOOR
UNITS
MULTI V 5 / MULTI V S / MULTI V M
MULTI V WATER IV (HEAT PUMP / HEAT RECOVERY) /
MULTI V WATER S
020 021
OUTDOOR UNITS _ MULTI V 5 OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
OUTDOOR
CREATIVE TECHNOLOGIES
UNITS
Dual Sensing SLC (Smart Load Control) Energy Saving by Dual
Enhanced energy saving & increased indoor Comfort (Temperature & Humidity) Sensing Control
MULTI V 5
Cooling loads vary according to both temperature and humidity. Case study
- Air cooled VRF Heat Pump & Heat Recovery With Dual sensing SLC, the proper amount of work can be exerted
- 22.4kW ~ 268.8kW (Cooling capacity based) Weather characteristics of Warsaw, Poland
to meet the load not only depending on current temperature, but
- 3Φ, 380 ~ 415V, 50 ~ 60Hz The portion of cooling operation hours at low humidity condition (below
also on humidity. As a result, less work will be needed at the same
50% RH) is big. The cooling load of this condition is less than the load at
- Top discharge outdoor unit temperature when humidity is lower.
standard (50 ~ 70% RH) or high (over 70% RH) humidity condition even in
- Ability to function as Heat Pump or Heat Recovery It influences the VRF system main processor’s decision on where to the same outdoor air temperature. MULTI V 5 raises the evaporating Temp.
set the system’s target high or low system pressure values. up at low load (low humidity) condition to enable energy saving and prevent
over-cooling which can happen when the system is controlled only by using
Smart Load Control monitors two inputs
1,000m 1) Outdoor ambient dry bulb temperature
outdoor air Temp.
Relative Humidity
70%
Heating Indoor Units - adjusts target high pressure Mid Humidity Dual
60% SLC Sensing
Lowers the target high pressure as heating load falls and/or ambient temperature rises. 50% ~ 70%
110m Raises the target high pressure as heating load rises and/or ambient temperature falls. 50%
SLC
Height Difference
between ODU ~ IDU Low Humidity
40% 0% ~ 50%
What are the benefits?
Partial Defrost 30%
Enhanced energy savings 20%
- Cooling Mode 23°C 25°C 27°C 29°C 31°C 33°C 35°C
By raising the target low pressure during off-peak cooling operation, the Source : Outdoor Air Temperature
https://energyplus.net/weather
compressor lift is reduced. This slows compressor’s speed which leads to a
decrease in compressor’s power consumption. Time Portion of Relative Humidity in Summer
(Warsaw, Poland)
- Heating Mode
RH (%) Portion
By lowering the target high pressure during off-peak heating operation, the
compressor lift is reduced. This slows compressor’s speed which leads to a 70% ~ 100% 8%
decrease in compressor’s power consumption. 50% ~ 70% 45%
Switchable Heat Pump and
0% ~ 50% 47%
Heat Recovery Increased indoor comfort
Smart Load Control uses one (or two) sensors to measure changing outdoor
weather conditions and prepares the VRF system for operation under the
revised weather conditions before the changed conditions have a chance to
Energy Consumption in Cooling Season
impact indoor comfort. When we compared the energy consumption between SLC (Outdoor air
40m
Height Difference Temp. sensing only) and Dual sensing SLC (Outdoor air Temp. and humidity
Cooling load according to Cooling load according to
between IDU ~ IDU temperature change humidity change sensing), Dual sensing SLC control can save 6% more energy compared to
SLC. So dual sensing control is more efficient than SLC.
Cooling Load
Cooling Load
Type
Changeover
EER
MULTI V 5 SLC
MULTI V 5 Dual Sensing SLC 9.4 9.4
9.2
9.0
8.1 8.6
25°C 30°C 35°C Temperature 40% 60% 80% Relative 7.9
Humidity
Latent heat load Sensible heat load 6.9 6.9
* constant indoor temp. condition 6.0
Cooling Load
Previous Cooling Capacity
022 023
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
OUTDOOR
CREATIVE TECHNOLOGIES
UNITS
Comfort Cooling Intelligent Defrost Variable Path Heat Exchanger Active Refrigerant Control
Increased indoor comfort & enhanced operating efficiency Increased heating run-hours Optimized system efficiency & continuous heating Stable operation & sustaining most efficient operation
MULTI V 5
When the IDU is operating in a season when its load is less than MULTI V has provided an intelligent defrost algorithm and settings MULTI V 5 outdoor units are manufactured with horizontally split The accumulator in the outdoor unit has a storage tank mounted
design, the comfort cooling algorithm controls the indoor unit’s coil based on current outdoor ambient temperature. With the addition ODU coil consisting of two independent circuit sections. Each half of inside known as the receiver tank. The receiver tank is equipped
superheat, thus raising the discharged air temperature as the space of the outdoor air humidity sensor, MULTI V 5 Intelligent Defrost just the coil is independently controlled. with inlet and outlet valves that are electronically opened and
temperature is approaching set point. MULTI V 5’s comfort control got smarter. This split coil feature makes it possible for MULTI V 5 to provide closed. Refrigerant is being passed between the accumulator
algorithm monitors the outdoor air temperature and humidity MULTI V 5 computes the current ambient air dew point temperature continuous heating during defrost. The split coil and valve and the receiver tank on a continuous basis. MULTI V 5 active
conditions. When changing weather conditions are deteriorating - the temperature at which frost will form on the outdoor unit coil arrangement also makes it possible for the MULTI V 5 to change refrigerant control algorithm goal is to minimize the amount of
and there is a high potential the indoor unit’s load will remain stable in winter operation. MULTI V 5 makes continuous adjustments to the flow path of refrigerant through one of the two coils only, or refrigerant in circulation. The lower the volume in circulation the
or may increase, comfort cooling delays or abandons raising the the refrigeration cycle operating parameters to keep the outdoor through both coils in either a series or parallel arrangement. Based lower the cost to move it around the system and the higher the
target superheat as the room temperature approaches set-point. coil surface temperature above actual dew point which can be on system pressures, ambient temperature conditions, and mode of stability of the refrigeration cycle. It accomplishes this by constantly
When changing weather conditions are favorable to raising target calculated by using dry bulb Temp. and relative humidity. When the operation, the system controller may modify the selected path at monitoring the system operating pressures and temperatures and
superheat, target superheat is moderated. refrigeration cycle operating parameters can be adjusted no further any time. a variety of other vital control metrics of the refrigeration cycle.
without sacrificing heating comfort, further adjustment is stopped When the cycle is out of balance, an adjustment in the amount of
What are the benefits? and frost is allowed to build on the coil. circulating refrigerant occurs.
What are the benefits?
Increased indoor comfort Optimizes system efficiency regardless of operating modes as ambient weather
If comfort cooling is turned off, and the temperature of the leaving air is not What are the benefits? conditions change. What are the benefits?
raised, when the fan speed is reduced to low speed, there is a potential that Customizes the used area of the outdoor unit’s heat exchange surface.
The Intelligent Defrost algorithm increases the VRF system’s heating run-hours Widens the ambient temperature range at which stable operation occurs.
occupants located directly under a cassette IDU or supply air registers could
and reduces the number of defrost cycles required to maintain optimum Low ambient cooling and / or light building load Sustains most efficient system operation regardless of outdoor weather
feel cold air falling on them resulting in a lower overall comfort experience.
heating performance irrelevant of the mode and method of defrost selected. conditions, operating mode, or building load.
With comfort cooling turned on, the discharged air temperature is controlled. • Half active
When the IDU controller reduces the fan speed, the potential for cold air falling • Lower idle
Cooling Heating Part Load
on occupants located under the cassette IDU or supply air registers is reduced.
Amount of refrigerant
Enhanced operating efficiency Full load cooling in receiver
Raising superheat reduces refrigerant volume flowing through the coil. As • Upper & lower active
flow decreases, demand on the compressor decreases and the compressor Conventional • Series circuited
speed will be reduced, thus saving energy. Defrost • High velocity refrigerant flow
Heating
Cooling Mode Fan Mode Cooling Mode
* Indoor unit set up available with Standard III Remote Controller Non-receiver tank
Cooling
Fixed refrigerant amount Control optimized Refrigerant amount
Maximized efficiency
Preventing cold draft & repeated turn On / Offs
Series Half Active Parallel
Improved Indoor Comfort
Efficiency
Continuous Heating
Indoor temp. Fixed refrigerant type
Heating performance
LG Intelligent Defrost /
Smart Heating
Frost Heating
Not cool
Coil accumulation begins efficiency 3%
zone
Surface (°C) Part load
efficiency 10%
On Heating supply On
Dew
Point (°C)
Comfort
zone Set
temperature Additional Time
Spent Heating
Effect of partial defrost
Too cool
zone Increased heating operation time per day : Up to 17%
Cooling
• LG Internal Test result, efficiency
• Test condition (MULTI V 5 vs MULTI V IV, 22HP) Time Active Refrigerant Control
Non-Partial defrost Refrigerant quantity (kg)
Previous Model Time - Outdoor : 2/1℃ , Indoor : 20/15℃
- Humidity : 83%, Dew Point : -0.5℃
024 025
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
OUTDOOR
CREATIVE TECHNOLOGIES
UNITS
HiPORTM Sub-cooling & Vapor Injection Ocean Black Fin Biomimetic Fan
Maximized reliability & efficiency of compressor Increased heating performance Improved durability Maximized performance
MULTI V 5
HiPOR™ is an LG trademark that stands for High Pressure Oil Return. MULTI V 5 is equipped with advanced sub-cooler and vapor injection The black coating with enhanced epoxy resin is applied on the heat MULTI V 5 outdoor units fans have been upgraded. The moire pattern
It consists of an oil separator, oil drain line between the separator and the control system. The sub-cooler algorithm sub-cools liquid refrigerant exchanger for strong protection from various corrosive external from external texture of clam shells has been applied on fans to create
compressor. HiPOR™ technology enables oil to return directly into the just enough so that it can travel to the farthest IDU in the system conditions such as salt contamination and air pollution. Moreover, the range difference that results in reduction of noise level. At the
compressor, instead of returning through the refrigerant suction pipe. operating in cooling mode without changing state. During low the hydrophilic film keeps water from accumulating on the heat same time, unlike the fans installed in previous products that generate
This does not waste energy when oil flows between the separator ambient operation down to -25℃, the sub-cooler provides medium exchanger’s fin, minimizing moisture buildup and eventually making separation of flow due to absence of tubercles, the bumpy back design
and the compressor. Because the operating pressure in the chamber temperature refrigerant gas to the compressor’s vapor injection it even more corrosion resistant. inspired by the bumps on the humpback whale’s flipper is applied as the
containing the oil sump of the compressor and the pressure in the oil system. When injected into the compression chamber, system mass LG Corrosion Resistance solution passed ISO 21207 accelerated tubercles on the back side of the fans, increasing wind power by reducing
separator are nearly equal, there is no loss in compressor efficiency. flow increases which stabilizes the system’s suction pressure. In all corrosion test conducted by an independent test organization flacking. In addition to the biomimetic technology-based fans, extended
cases the vapor injection increases the compressors cycle efficiency and the result has been certified by prestigious global certification shroud of MULTI V 5 allows more high static pressure and helps fans
What are the benefits? and reduces operating cost. organization, UL (Underwriters Laboratories). to blow higher air volume for efficient operation. With wider air guide,
Maximizes reliability and efficiency of the compressor discharged air current is stabilized and noise level is reduced.
Non HiPOR™ HiPOR™ What are the benefits? What are the benefits?
Compressor
1 Refrigerant Provides stable refrigeration cycle operation over a wide range of outdoor This improvement in durability prolongs the product’s lifespan and lowers both What are the benefits?
3 ambient operating conditions. the operational and maintenance costs. Based on the biomimetic technology, the fans of MULTI V 5 increased air
4
Increases compressor efficiency when compared to systems without vapor flow rate by 10% in comparison to previous model and reduced its power
Efficiency Increase injection technology. consumption up to 20% when compared with the fan blade design on
Up to 33%
2 MULTI V IV. This eventually results in maximized performance with large capacity.
Oil Technology Mechanism
5
processor is notified that an oil return cycle is necessary. Oil balancing
EEV
cycle occurs every hour and does not hinder system performance.
It balances the oil level deposit between both compressors in multi- High temp * Tested by Method B
discharge (Test condition: Salt contaminated condition +
compressor frames. Older VRF technology protects compressors from severe industrial / traffic environment (NO2 / SO2))
oil loss based on timed oil return logic because there was no way to
know if the oil level in any one compressor was low. LG’s unique oil level MID-stage Injection
SC
measuring sensor actively monitors the oil level in each compressor. HEX
Low temp Hydrophilic film (Water flow)
What are the benefits? suction THe Hydrophilic coating minimizes moisture
buildup on the fin.
Energy savings compared with other systems. Fewer oil return cycles eliminates
Epoxy resin (Corrosion resistant)
unnecessary energy consumption.
The Black coating provides strong protection
Increases system heating run-time during winter operation. from corrosion.
ODU Coil
Increases compressor reliability.
Aluminum fin
Heating Performance Smart Oil Return Air flow rate Power consumption
Oil Oil
Temperature 35°C
Non heating Non heating 320 1,500
Oil Non-Vapor Injection 20%
Time
27% Mist of 5% NaCl (mass fraction) solution 10%
Timed oil return logic (Non-oil Sensor) Oil Level Sensor 290
Increased heating operation time per day Auto Oil Balancing Up to Condition of gas exposure test 1,200
: Up to 12% -25℃
Gas Volume Fraction
• LG Internal Test result, Relative
Temp.
• Test condition Humidity
NO2 SO2
- without oil level sensor : -25 -20 -15 -10 -5 0 7 11 15
026 027
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
OUTDOOR
DESIGN FLEXIBILITY USER-FRIENDLY CONTROL
UNITS
One Unified Model Flexible Installation with Low-Noise Operation Simple Test Run via LGMV
Heat pump / Heat recovery with one platform Large Capacity Outdoor Units For noise sensitive environment Increased overall efficiency in installation
More flexible design potential & Space saving
MULTI V 5
LG MULTI V 5 satisfies users’ various needs with just one platform. Unlike the previous model which enables Low-Noise Operation To make sure that the product functions properly, conducting a test run
Heat Pump System works for the sites where either cooling or heating only during night after judgment time, the Low-Noise Operation of is recommended. For previous product, professional engineer who is well-
Large capacity outdoor units of MULTI V 5 minimize installation
operation is needed, while Heat Recovery System fits perfectly to the MULTI V 5 can function regardless of the time at the noise sensitive aware of more than 40 different functional settings and more than 200
space that spares valuable floor space and significantly decreases
sites wherein both the cooling and heating operations are simultaneously areas. When used, the speed of the outdoor unit fans is restricted error codes had to check main parts in order to make sure that the test
total installed weight. This gives users more flexible design potential
needed or locations installed with Hot Water Solution to provide hot during normal operation. run had succeeded. With Mobile LGMV of MULTI V 5, fast and accurate
and better use of the saved space.
water and heating via radiator. By providing suitable solutions that cater auto test run can be executed and the professional installer running the
to any building types and their requirements, MULTI V 5 offers the best Previous Model test can receive test results via email, which shortens installation hours
12.25m2
HVAC system. and increases overall efficiency in installation processes.
On
12.25m2 9.42m2 3,640kg 3,100kg
6:00 12:00 13:00 18:00 21:00 0:00 6:00
Highest Start End
Previous Model Previous Model outdoor temp.
Foot print area Product weight
* Comparison basis : 1 Rows of outdoor units 728kW (72.8kW x 10sets) installation case
Low-noise Low-noise
making the product adequate for uses in specialized venues like operation operation
Type
technical rooms. Moreover, MULTI V 5’s cycle technology with enhanced On Off On Wi–Fi MV Module
durability enables optimal cooling performance at high temperature
6:00 12:00 18:00 6:00
that increases up to 48°C. Start End Start End
-20°C
-25°C
10°C 15°C 20°C 27°C
028 029
50
OUTDOOR UNITS _ MULTI V 5 _ TECHNICAL DATA
50
Multi
MultiVV
55 Outdoor
Outdoor
Units
Units
Nomenclature Cooling / Heating Operation GravityGravity point
point Gravity point
ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5
OUTDOOR
ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5
9.9.Operation
OperationLimits
Limits
2. Dimensions
Multi V 5
UNITS
ARU M 100 L T E 5
Cooling
Cooling
/ Heating
/ Heating
Operation
Operation
Gravity point
[Unit : mm] No.
1
Part Name
Leakage test hole (side)
Description
Ø 22.2
Cooling Heating 2 Wire routing hole (bottom) 2-Ø 22.2
Serial number Gravity point 3 Power cord routing hole (bottom) 2-Ø 50
50°C 20°C 4 Pipe routing hole (front) -
E: High Efficiency 48°C 18°C 5 Pipe routing hole (bottom) 2-Ø 66, Ø 53.88
45°C 6 Power cord routing hole (front) 2-Ø 45
15°C 7 Wire routing hole (front) 2-Ø 30
Air Discharge Type
MULTI V 5
10°C
298
MULTI V System with Indoor Unit using R410A 5°C 245
ARU : Global line-up
10.1 Sound Pressure Level 0°C -15°C 236
185
-5°C
Position of Sound Pressure Level -20°C 156
Note -10°C
1,690
76
731
Note
Note
799
factors such
1. 1.
as
These
These
the
figures
construction(acoustic
figuresassume
assume thethefollowing
followingoperating
operating
conditions:
conditions:
[mm(inch)]
1m
absorption coefficient)
Note
Equivalent
Equivalent pipingoflength:7.5m
piping particular room in
length:7.5m 165
System Heat Recovery Heat Pump
1. These
which the equipment figures assume
is installed the following operating conditions: Liquid Low Pressure High Pressure Liquid Gas
92 175
HP
Level
Leveldifference:0m
difference:0m pipe Gas pipe Gas pipe pipe pipe
219
Equivalent piping length : 7.5m
162
1m
141
• Sound level can
2. 2.
Levelbe
Range
Range of increased
of pullpull
down
difference
down
: 0m in static
operation:
operation: 8 Ø 9.52 (3/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 9.52 (3/8) Ø 19.05 (3/4) 101 730
If the
If the
relative
relativehumidity
humidityis too
is too
high,
high,
cooling
cooling
capacity
capacity
cancan
be be
decreased
decreased
by by
thethe
sensible
sensible
heat
heat
reduction.
reduction.
pressure mode or used air guide.
10 Ø 9.52 (3/8) Ø 22.2 (7/8) Ø 19.05 (3/4) Ø 9.52 (3/8) Ø 22.2 (7/8)
2. Range of pull down operation : 144 159 71 71 (Pitch of foundation bolt holes)
12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
• Data is valid at free field condition If the relative humidity is too high, cooling capacity can be decreased by the sensible heat 462
reduction. 625 414
• Data is valid at nominal operating condition 670
Unit:dB(A)
• Sound level will vary depending on a range of factors such as the 675 760
Mo(acoustic
del Coolingroom in Multi
Heating 735
construction absorption coefficient) of particular Multi V 5V 5 Outdoor
Outdoor Units
Units
740
Outdoor Units
System System System Heat Recovery
Heat Recovery Heat Re
ARUM120LTE5 59.0 Simultaneous
Cooling
Simultaneous 6Cooling
Cooling0.0 / Heating
/ Heating Operation
Operation Heating
Liquid Liquid
Low Liquid
LowHigh
Pressure
Low High
ARUM140LTE5 60.0 61.0 HP HP
System HP Pressure Heat Recovery
Pre
Pressure
pipe pipe
Gas pipe pipe
Outside Unit Function Gas Gas
pipe pipe
Gas pG
ARUM160LTE5 60.5 30°C 61.5 20°C
HP
Liquid Low Pressure Hig
8 8 (3/8) Ø 9.52
Ø 9.52 (3/8)(3/4)
819.05
Øpipe Ø 19.05
Ø 9.52 Ø(3/8)(3/4)
15.88 Ø1
Ø(5/8)
19.05
ARUM180LTE5
Category Functions 61.0 MULTI V 5 62.0 Gas pipe
25°C 16°C 10 10 (3/8) Ø 9.52
Ø 9.52 Ø10 (3/8)
22.2 Ø 22.2
Ø 9.52
(7/8) Ø (7/8)Ø(3/4)
(3/8)
19.05 Ø 1(
22.2
ARUM200LTVariable E5 Path of Outdoor Unit HEX 62.0 ○ 64.5 Outdoor Temperature (°C WB)
ARUM140LTE5 / ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5 8 Ø 9.52 (3/8) Ø 19.05 (3/4) Ø 1
Outdoor Temperature (°C DB)
Humidity Sensor ○
Range for pull down operation
Components
ARUM240LTAnti E5 Corrosion Black Fin 65.0 ○ 67.0 675675
12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 1
Range for warming up operation
2. Dimensions
Multi V 5
Low Noise Operation ○ 3 Power cord routing hole (bottom) 2-Ø 50
ARUM241LTE5 62.0 63.0 5°C 4 Pipe routing hole (front) -
Hgih Static Mode of Outdoor Unit Fan ○ 5°C
ARUM261LTPartial E5 Defrosting 62.5 ○ 63.5 5 Pipe routing hole (bottom) 2-Ø 66, Ø 53.88
6 Power cord routing hole (front) 2-Ø 45
ARUM280LTAuto E5 Cleaning of Outdoor Unit 62.8 ○ 0°C 63.8 7 Wire routing hole (front) 2-Ø 30
0°C
ARUM300LT(Fan
Useful Function E5 reverse rotation) 63.1 64.1
Indoor Cooling Comfort Mode Based -5°C
ARUM320LTOutdoor E5 Temperature 63.8 ○ 65.8
ARUM340LTE5 Smart Load Control (SLC) 65.6 -10°C 66.6 -5°C
(Changing indoor discharge air ○
ARUM360LTtemperature
E5 according to load) 66.0 67.8 3D View
ARUM380LTOutdoor E5 Unit Control Refer to Humidity 66.2 ○
-15°C
68.0 20°C
10°C 14°C 15°C 25°C 27°C 30°C -10°C
ARUM400LTDefrost E5 / Deicing 66.3 ○ 68.1 10°C 15°C 20°C 25°C27°C 30°C
High Pressure Switch ○ 302
ARUM420LTE5 66.5 68.2
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
Phase Protection ○ Note 280
ARUM440LTRestart E5 66.8 ○ Note 68.the 9 following operating conditions:
Reliability Delay (3-minutes)
1. 1. These
These figures
figures assume
assume the following operating conditions: 267
ARUM460LTSelf E5 Diagnosis 67.8 ○ Note
Equivalent
Equivalent piping
piping 69.3
length:7.5m
length:7.5m
1. These
Level figures
difference:0massume the following operating conditions: 214
ARUM480LTSoft E5 Start 68.0 ○ Level difference:0m 70.0
Equivalent piping length : 7.5m
2. 2. Range
Range of pull
of pull down
down operation:
operation: 205
ARUM500LTTest E5 Run Function 67.0 ○ IfLevel
If the the difference
relative
relative humidity 6is: 8
humidity 0m.is6too
too high,
high, cooling
cooling capacity
capacity cancan
be be decreased
decreased by the
by the sensible
sensible heatheat reduction.
reduction. 154
AC Ez (Simple Controller) PQCSZ250S0 2. Range of pull down operation :
ARUM520LTAC E5Ez Touch 67.PACEZA000
1 68.7
If the relative humidity is too high, cooling capacity can be decreased by the sensible heat 125
1,690
ARUM540LTAC E5Smart IV 67.PACS4B000
2 reduction. 68.8 [mm(inch)]
109
92
Controller System Heat Recovery Heat Pump
189
Liquid Low Pressure High Pressure Liquid Gas
HP
ARUM580LTACP E5 (Advanced Control Platform) IV 68.PACP4B000
3 69.8 pipe Gas pipe Gas pipe pipe pipe
ACP (Advanced Control Platform) 5 PACP5A000 14~16 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
ARUM600LTAC E5Manager 5 68.PACM5A000
5 70.4
76
18~20 Ø 15.88 (5/8) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)
705
ARUM620LTACP
BNU (Building E5 Lonworks 68.PLNWKB000
6 70.5 22
24
Ø 15.88 (5/8) Ø 28.58(1-1/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)
Ø 15.88 (5/8) Ø 34.9(1-3/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 34.9 (1-3/8)
165
NetworkAUnit)
RUM640LTACP E5 BACnet 68.PQNFB17C0
7 70.6
92 176
26~34 Ø 19.05 (3/4) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 34.9 (1-3/8)
220
ARUM660LTRefrigerant
E5 Charging Kit 68.8 PRAC1 70.6
162
140
36~40 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)
Installation
Variable Water Flow Valve Control Kit - 42~60 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 34.9 (1-3/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)
ARUM680LTStandard E5 69.PPWRDB000
0 71.1 159 Ø 22.2 (7/8)
13862~64 Ø 44.5 (1-3/4) Ø 41.3 (1-5/8) Ø 22.2 (7/8) Ø 44.5 (1-3/4) 71 71 100 1,040
PDI (Power 439
ARU
Distribution M700LTPremium
Indicator) E5 69.PQNUD1S40
6 71.3 66~96 Ø 22.2 (7/8)
444
Ø 53.98 (2-1/8) Ø 44.5 (1-3/4) Ø 22.2 (7/8) Ø 53.98 (2-1/8) 442.5 System System System
Heat Recovery Heat Rec
Heat Recovery
(Pitch of foundation bolt holes)
503 System Heat Recovery L
ARU
Cool / Heat M720LTE5
Selector 69.8 PRDSBM 71.8 508
760
HP
Liquid
HP Low HP
Liquid Liquid
Pressure High
Low Low Pres
Pressure
Pressure H
Low Ambient Kit740LTE5 pipe pipe
GasLiquid
pipe pipeGas
Low Gas pipeGas Hig
pipe
Pressure pip
ARUM 69.1 PRVC2 70.9 593 HP
pipe Gas pipe
IO Module (ODU Dry Contact) PVDSMN000 676676 1,240 14~16 Ø 12.7 (1/2)
14~16Ø 28.58
14~16
Ø 12.7 Ø 12.7
(1-1/8)
(1/2) ØØ(1/2)
22.2
28.58 Ø
(7/8)28.58
(1-1/8) (1Ø
Ø 12
ARUM760LTLGMV E5 69.2 PRCTIL0 70.9 14~16 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø
Cycle Monitoring 18~20 Ø 15.88 (5/8)
18~20Ø 28.58
18~20
Ø 15.88 Ø
(1-1/8) 15.88
(5/8) (5/8)
ØØ22.2
28.58 Ø
(7/8)28.58
(1-1/8) (1Ø
Ø 15
Device Mobile LGMV PLGMVW100 18~20 Ø 15.88 (5/8) Ø 28.58 (1-1/8) Ø
677 22 Ø 15.88 (5/8) Ø2215.88Ø
22 Ø 28.58(1-1/8) 15.88
(5/8) Ø(5/8)
Ø 28.58 Ø 28.58(1
(1-1/8)
28.58(1-1/8)Ø 15Ø
※ ○ : Applied, - : Not Applied Ø 24
15.88 (5/8)
22 ØØ28.58
28.58(1-1/8) Ø2
Outdoor Units
24 Ø 15.88 (5/8) Ø 15.88Ø
24 Ø 34.9(1-3/8) 15.88
(5/8) Ø(5/8) Ø 34.9(1-3
(1-1/8)
34.9(1-3/8) Ø
Ø 15
24 Ø 15.88 (5/8) Ø 34.9(1-3/8) Ø 2
26~34 Ø 19.05 (3/4)
26~34 26~34
Ø 34.9
Ø 19.05 Ø
(1-3/8) 19.05Ø(3/4)
Ø 28.58
(3/4) 34.9 Ø 34.9
(1-1/8)
(1-3/8)Ø (1-
Ø
19
51 26~34 Ø 19.05 (3/4) Ø 34.9 (1-3/8) Ø 2
36~40 Ø 19.05 (3/4)
36~40 36~40
Ø 41.3
Ø 19.05 Ø
(1-5/8) 19.05Ø(3/4)
Ø 28.58
(3/4) 41.3 Ø 41.3
(1-1/8)
(1-5/8)Ø (1-
Ø
19
030 031
36~40 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 2
42~60 Ø 19.05 (3/4)
42~60 42~60
Ø 41.3
Ø 19.05 Ø
(1-5/8) 19.05
(3/4) Ø(3/4)
Ø 34.9 Ø 41.3
(1-3/8)
41.3 (1-5/8)Ø (1-
Ø
19
42~60 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 3
51
OUTDOOR
MULTI V 5 Q&A
UNITS
Q1 What are the differences between MULTI V IV and MULTI V 5? Q3 How does MULTI V 5 operate when humidity reference of the dual sensing SLC is that of the outdoor?
MULTI V 5
A1 Category MULTI V IV H/P (ARUN***LTE4) MULTI V 5 H/P & H/R (ARUM***LTE5) A3 During dual sensing SLC, outdoor unit changes target pressure of the system referring to temperature and humidity in cooling mode.
- When the humidity of outdoor side is higher than that of indoor side, outdoor unit will lower target pressure to remove humidity, thus
Vapor Injection ◯ ◯
outdoor unit will consume more energy and indoor will be more cooled compared to SLC operation but more efficiency than normal operation
HiPORTM ◯ ◯
Height Difference (ODU ~ IDU / IDU ~ IDU) 110m / 40m 110m / 40m
Normal operation (non -SLC)
Cooling Operating Range (OAT, °CDB) -10 ~ 43 -15 ~ 48
20°C 25°C 30°C 35°C
Heating Operating Range (OAT, °CWB) -25 ~ 18 -25 ~ 18
1 Unit 50 ~ 200% 50 ~ 200% - When the humidity of outdoor side is lower than that of indoor side, outdoor unit will rise target pressure to save energy and keep
Combination ratio of IDU 2 Unit 50 ~ 160% 50 ~ 160% comfort, but indoor humidity will be less removed compared to normal operation.
ODU IDU Compatibility ODU DIP Switch No. 3 If dip switch setting is not correct Ref. 20°C 25°C 30°C 35°C
Discharge air will be less cold than normal or
SLC operation. Efficiency SLC under the low humidity condition
Can not communicate between Indoor (%)
Must be OFF
Gen. 2 (ARNU*2) ◯ & Outdoor unit
(factory default)
(System will not be operated)
Normal operation (non -SLC)
When Dip Switch No. 3 is OFF, 20°C 25°C 30°C 35°C
MULTI V IV Must be ON to enable
Gen. 4 (ARNU*4) ◯ System can be operated, but
MULTI V 5 gen. 4 functions
some function of Gen. 4 is not available
To keep comfort and save energy you may turn off outdoor unit humidity sensing or propose to install new standard remote controller in
When Dip Switch No. 3 is ON, order to sensing indoor humidity.
Must be OFF Can not communicate between Gen. Some function of Gen.
Gen. 2 + Gen. 4 ◯
(factory default) 2 Indoor & Outdoor unit (Gen 2 units are not 4 is not available
operated), only Gen 4 Units are operated. Sensing point SLC Setting
CASE 1. Dual Sensing SLC with Outdoor humidity sensor in ODU Setting
※ ○ : Applied, - : Not Applied Outdoor humidity
by humidity sensor (ODU) DIP-SW01
ODU main PCB dip switch is all “OFF” at default state SW04C ( X : cancel) Setting summary
SW03C (▶: forward) DIP-SW01 #5 On
(1) Check and make sure that all connected indoor units are 4 series. (ARNU******4.) SW02C (◀ : backward) Func > Fn14 >
(2) Change Dip switch No. 3 from OFF → ON Off, op1 ~ op3
SW01C (●: Confirm/
(3) Push the reset button. Automatic Addressing)
SW01D (reset)
Dip Switch 7 segment
Indoor humidity CASE 2. Dual Sensing SLC with Indoor humidity sensor in New Standard
ON ON R/C setting (PREMTB100)
Setting summary
Reset Function>
button Smart Load Control>
Off, op1 ~ op3
1 2 3 4 5 6 7 1 2 3 4 5 6 7
1 2 3 4 5 6 7 1 2 3 4 5 6 7
※ User can turn off humidity control in ODU Setting (humidity reference)
<Setting summary> ODU DIP-SW01 #5 On > Func > Fn16 > Off
032 033
OUTDOOR UNITS _ MULTI V 5 _ Q&A
OUTDOOR
MULTI V 5 Q&A
UNITS
Q4 What is the principle and accuracy of humidity sensor? Other Questions
MULTI V 5
A4 Total Tolerance (%) = Sensor measurement tolerance (%) + Location of sensor tolerance (%) Upper electrode
Item Question Answer
The capacitive measurement principle established and proved itself as a standard in the past. Thin-film polymer
For this principle, the sensor element is built out of a capacitor. The dielectric is a polymer Lower electrode The static pressure of MULTI V 5 is Max.
Fan Yes, the static pressure of MULTI V 5 is the same with MULTI V IV.
which absorbs or releases water proportional to the relative environmental humidity, and thus Glass substrate 8 mmAq as MULTI V IV??
changes the capacitance of the capacitor. This change in capacitance can be measured by an
electronic circuit. For humidity sensors with CMOSensⓇ technology, a “micro-machined” finger
electrode system with different protective and polymer cover layers forms the capacitance for Is the limitation of Compressor max. Hz applied by the No, the limitation of comp Hz is not applied for default. But, it can be
Compressor
the sensor chip, and, in addition to providing the sensor property, simultaneously protects the capacity of outdoor unit? set by option for limitation of max Hz (or current).
sensor from interference in ways previously not achieved.
Model Humidity Sensor of Outdoor Humidity Sensor of R/Controller MULTI V 5 has the function of both H/P and H/R by one unit.
Size (mm) 3 x 3 x 1.1 2.5 x 2.5 x 0.9 Main valve has a function to change the operation mode.
4Way V/V The usage of main & sub 4 way valve for MULTI V 5 ?
(cooling ↔ heating) Sub. Valve has a functions to change the
Supply voltage range 2.1 to 3.6 V 2.4 to 5.5 V product type (H/P ↔ H/R)
T operating range -40 to +125°C (-40 to +257°F) -40 to +125°C (-40 to +257°F) The optimal middle pressure for vapor injection is 1.2 PS.
VI In case of vapor injection, how much is the middle pressure?
RH response time 8 sec (tau 63%) 8 sec (tau63%) PS : Suction pressure of compressor
Q5 What is difference in refrigerant piping connection between heat pump and heat recovery?
Humidity
A5 From MULTI V 5, Low pressure gas pipe in heat pump operation changes to high pressure gas pipe in heat recovery operation Sensor
Where is Indoor Humidity sensor? It is placed inside of the RS3 remote controller.
due to internal cycle. So for heat pump cycle, no. 1, 3 pipe should be connected and for heat recovery operation, No. 1,2,3 pipe is
connected. (For the heat pump operation, DO NOT connect No.2 pipe)
Remote Does remote controller show the humidity information Yes. It shows the current humidity information on screen.
Heat Recovery Installation Heat Pump Installation Controller (status) as well? (for RS3 Only) But has no function to control the humidity
Close Close
Remote Is it possible to connect the local humidity sensor with No. All of RS3 remote controller can not be connected with local
Controller Remote controller (RS3)? humidity sensor.
Close Close
1 Close 2 3 1 2 3
Close
SLC Does dual sensing SLC function control the humidity ratio? No. There is no control of humidity ratio.
High Pressure
Low Pressure
Liquide pipe
Liquide pipe
Gas pipe
Gas pipe
Gas pipe
Is SLC fully used on Eurovent? Isn’t humdity fixed Eurovent (RH 47%) and AHRI (RH 51%) have fixed humidity test
SLC
for the test? What about AHRI? condition.
Reducer for Gas Pipe
8HP 9.52 19.05 15.88 8HP 9.52 No Use 19.05 15.88 19.05
Comfort cooling need super heating controlled and Comfort heating
10HP 9.52 22.2 19.05 10HP 9.52 No Use 22.2 19.05 22.2 Comfort
Why is not the comfort heating applied in product? need sub cooling controlled. In case of controlling EEV for sub cooling,
Cooling
20HP 15.88 28.58 22.2 20HP 15.88 No Use 28.58 noise and stable operation may be affected and critical.
22.2 28.58
※ For using as Heat Pump, Reducer for Gas pipe should be used.
Reducer is included in outdoor unit.
Does the IDU – Central controller direct connection for
Installation No, it is not possible.
communication cable is possible? (Flat connection)
034 035
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5 LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
UNITS
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com
MULTI V 5
ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5 / ARUM140LTE5 ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5 / ARUM220LTE5
HP 8 10 12 14 HP 16 18 20 22
Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Model Name Model Name
Independent Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 Independent Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Cooling (Rated) kW 22.4 28.0 33.6 39.2 Cooling (Rated) kW 44.8 50.4 56.0 61.6
Capacity Heating (Rated) kW 22.4 28.0 33.6 39.2 Capacity Heating (Rated) kW 44.8 50.4 56.0 61.6
Heating (Max) kW 25.2 31.5 37.8 44.1 Heating (Max) kW 50.4 56.7 63.0 69.3
Cooling (Rated) kW 4.49 5.80 7.58 8.68 Cooling (Rated) kW 10.89 10.91 12.77 15.70
Input Heating (Rated) kW 3.97 4.92 6.85 8.13 Input Heating (Rated) kW 10.28 10.12 12.20 14.15
Heating (Max) kW 4.78 5.92 8.26 9.72 Heating (Max) kW 12.39 11.94 14.69 16.76
EER 4.99 4.83 4.43 4.52 EER 4.11 4.62 4.39 3.92
SEER 10.1 9.7 9.59 8.89 SEER 8.38 8.23 8.05 7.51
Rated Capacity 5.64 5.69 4.91 4.82 Rated Capacity 4.36 4.98 4.59 4.35
COP COP
Max. Capacity 5.27 5.32 4.58 4.54 Max. Capacity 4.07 4.75 4.29 4.13
SCOP 4.69 4.51 5.01 4.63 SCOP 4.83 4.0 3.98 3.9
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 4,200 x 1 5,300 x 1 5,300 x 1 5,300 x 1 Compressor W x No. 5,300 x 1 (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1)
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 3,900 3,900 3,900 Oil Charge cc 3,900 5,200 5,200 5,200
Type Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2 W x No. 900 x 2 900 x 2 900 x 2 900 x 2
Number Number
Fan Air Flow Rate (High) m3/min x No. 240 x 1 240 x 1 240 x 1 320 x 1 Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1 320 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 12.7 (1/2) Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8)
Pipe Pipe
Low Pressure Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Low Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
Connctions #1 Connctions #1
High Pressure Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) High Pressure Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 12.7 (1/2) Pipe Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8)
Connctions #2 Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Connctions #2 Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x1 Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 198 x 1 215 x 1 215 x 1 237 x 1 Net Weight kg x No. 237 x 1 300 x 1 300 x 1 300 x 1
Shipping Weight kg x No. 208 x 1 225 x 1 225 x 1 250 x 1 Shipping Weight kg x No. 250 x 1 312 x 1 312 x 1 312 x 1
Sound Cooling dB(A) 58.0 58.0 59.0 60.0 Sound Cooling dB(A) 60.5 61.0 62.0 64.5
Pressure Level Heating dB(A) 59.0 59.0 60.0 61.0 Pressure Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Power Cooling dB(A) 84.0 85.0 86.0 89.0 Sound Power Cooling dB(A) 90.0 92.0 93.0 93.0
Level Heating dB(A) 87.0 88.0 89.0 93.0 Level Heating dB(A) 94.0 95.0 96.0 97.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Refrigerant Name R410A R410A R410A R410A
Precharged Amount Precharged Amount
kg 7.5 9.5 9.5 13.5 kg 13.5 16.0 16.0 16.0
Refrigerant in Factory Refrigerant in Factory
t-CO2 eq. 15.7 19.8 19.8 28.2 t-CO2 eq. 28.2 33.4 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 20 (30) 23 (35) Number of Maximum Connectable Indoor Units 1) 26 (40) 29 (45) 32 (50) 35 (56)
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
036 037
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5 LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
UNITS
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com
MULTI V 5
ARUM240LTE5 / ARUM260LTE5 / ARUM221LTE5 / ARUM241LTE5 ARUM261LTE5 / ARUM280LTE5 / ARUM300LTE5 / ARUM320LTE5
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
038 039
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5
UNITS
MULTI V 5
ARUM340LTE5 / ARUM360LTE5 / ARUM380LTE5 / ARUM400LTE5 ARUM420LTE5 / ARUM440LTE5 / ARUM460LTE5 / ARUM480LTE5
HP 34 36 38 40 HP 42 44 46 48
Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5 Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5
Model Name ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 95.2 100.8 106.4 112.0 Cooling (Rated) kW 117.6 123.2 128.8 134.4
Capacity Heating (Rated) kW 95.2 100.8 106.4 112.0 Capacity Heating (Rated) kW 117.6 123.2 128.8 134.4
Heating (Max) kW 107.1 112.1 118.4 124.7 Heating (Max) kW 131.0 137.3 143.6 148.5
Cooling (Rated) kW 23.28 24.98 26.08 28.29 Cooling (Rated) kW 28.31 30.17 33.10 34.80
Input Heating (Rated) kW 21.00 22.74 24.02 26.17 Input Heating (Rated) kW 26.01 28.09 30.04 31.78
Heating (Max) kW 25.02 27.06 28.52 31.19 Heating (Max) kW 30.74 33.48 35.56 37.60
EER 4.09 4.04 4.08 3.96 EER 4.15 4.08 3.89 3.86
SEER - - - - SEER - - - -
Rated Capacity 4.53 4.43 4.43 4.28 Rated Capacity 4.52 4.39 4.29 4.23
COP COP
Max. Capacity 4.28 4.14 4.15 4.00 Max. Capacity 4.26 4.10 4.04 3.95
SCOP - - - - SCOP - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. (5,300 x 2) + (4,200 x 1) 5,300 x 3 5,300 x 3 5,300 x 3 Compressor W x No. (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) 5,300 x 4
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 9,100 9,100 9,100 9,100 Oil Charge cc 10,400 10,400 10,400 10,400
Type Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4 W x No. 900 x 4 900 x 4 900 x 4 900 x 4
Number Number
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2 Fan Air Flow Rate (High) m3/min x No. 320 x 2 320 x 2 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Pipe Pipe
Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
Connctions #1 Connctions #1
High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connctions #2 Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Connctions #2 Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
(1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 Net Weight kg x No. (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) 310 x 2
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. (300 x 1) + (215 x 1) (310 x 1) + (215 x 1) (310 x 1) + (237 x 1) (310 x 1) + (237 x 1) Shipping Weight kg x No. (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) 320 x 2
Shipping Weight kg x No. (312 x 1) + (225 x 1) (320 x 1) + (225 x 1) (320 x 1) + (250 x 1) (320 x 1) + (250 x 1) Sound Cooling dB(A) 66.5 66.8 67.8 68.0
Sound Cooling dB(A) 65.6 66.0 66.2 66.3 Pressure Level Heating dB(A) 68.2 68.9 69.3 70.0
Pressure Level Heating dB(A) 66.6 67.8 68.0 68.1 Sound Power Cooling dB(A) 96.8 97.1 97.1 98.0
Sound Power Cooling dB(A) 93.8 95.5 96.0 96.2 Level Heating dB(A) 100.5 100.8 101.1 102.0
Level Heating dB(A) 97.6 99.4 100.0 100.2 mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
mm2 x No. (VCTF-SB)
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Refrigerant Name R410A R410A R410A R410A
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Precharged Amount
kg 33.0 33.0 33.0 34.0
Precharged Amount Refrigerant in Factory
kg 25.5 26.5 30.5 30.5 t-CO2 eq. 68.9 68.9 68.9 71.0
Refrigerant in Factory
t-CO2 eq. 53.2 55.3 63.7 63.7 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 Number of Maximum Connectable Indoor Units 1) 64 64 64 64
Number of Maximum Connectable Indoor Units 1) 55 (64) 58 (64) 61 (64) 64 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
040 041
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5
UNITS
MULTI V 5
ARUM500LTE5 / ARUM520LTE5 / ARUM540LTE5 / ARUM560LTE5 ARUM580LTE5 / ARUM600LTE5 / ARUM620LTE5 / ARUM640LTE5 / ARUM660LTE5
HP 50 52 54 56 HP 58 60 62 64 66
Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM540LTE5 ARUM560LTE5 Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM620LTE5 ARUM640LTE5 ARUM660LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5
Cooling (Rated) kW 140.0 145.6 151.2 156.8 Cooling (Rated) kW 162.4 168.0 173.6 179.2 184.8
Capacity Heating (Rated) kW 140.0 145.6 151.2 156.8 Capacity Heating (Rated) kW 162.4 168.0 173.6 179.2 184.8
Heating (Max) kW 156.2 162.5 168.8 175.1 Heating (Max) kW 181.4 186.3 192.6 198.9 205.2
Cooling (Rated) kW 33.66 35.87 35.89 37.75 Cooling (Rated) kW 40.68 42.38 43.48 45.69 45.71
Input Heating (Rated) kW 30.87 33.02 32.86 34.94 Input Heating (Rated) kW 36.89 38.63 39.91 42.06 41.90
Heating (Max) kW 36.78 39.45 39.00 41.74 Heating (Max) kW 43.82 45.86 47.32 49.99 49.54
EER 4.16 4.06 4.21 4.15 EER 3.99 3.96 3.99 3.92 4.04
SEER - - - - SEER - - - - -
Rated Capacity 4.54 4.41 4.60 4.49 Rated Capacity 4.40 4.35 4.35 4.26 4.41
COP COP
Max. Capacity 4.25 4.12 4.33 4.19 Max. Capacity 4.14 4.06 4.07 3.98 4.14
SCOP - - - - SCOP - - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 5 (Inverter) x 5 Type
Scroll Scroll Scroll Scroll Scroll
Motor Output x Combination x No. (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 6
Compressor W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) (5,300 x 4) + (4,200 x 1)
Number Motor Output x
Compressor W x No. (5,300 x 4) + (4,200 x 1) 5,300 x 5 5,300 x 5 5,300 x 5 (5,300 x 5) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Number
Oil Charge cc 13,000 13,000 14,300 14,300 Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Type Propeller fan Propeller fan Propeller fan Propeller fan Oil Charge cc 14,300 14,300 14,300 14,300 15,600
Motor Output x Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
Number Motor Output x
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6 900 x 6
Number
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Fan Air Flow Rate (High) m /min x No. (320 x 2) + (240 x 1)
3
(320 x 2) + (240 x 1) 320 x 3 320 x 3 320 x 3
Discharge Side / Top TOP TOP TOP TOP Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Discharge Side / Top TOP TOP TOP TOP TOP
Pipe
Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connctions #1 Pipe
High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
Connctions #1
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4)
Connctions #2 Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
(1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + Connctions #2 Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
Dimensions (W x H x D) mm x No.
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
(1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
Dimensions (W x H x D) - Shipping mm x No. + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
(310 x 1) + (237 x 1) + (310 x 1) + (237 x 1) + (310 x 1) + (300 x 1) + (310 x 1) + (300 x 1) + Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Net Weight kg x No. + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(215 x 1) (215 x 1) (215 x 1) (215 x 1) (310 x 1) + (300 x 1) +
(320 x 1) + (250 x 1) + (320 x 1) + (250 x 1) + (320 x 1) + (312 x 1) + (320 x 1) + (312 x 1) + Net Weight kg x No. (310 x 2) + (215 x 1) (310 x 2) + (237 x 1) (310 x 2) + (237 x 1) (310 x 2) + (300 x 1)
Shipping Weight kg x No. (215 x 1)
(225 x 1) (225 x 1) (225 x 1) (225 x 1) (320 x 1) + (312 x 1) +
Cooling dB(A) 67.0 67.1 67.2 67.4 Shipping Weight kg x No. (320 x 2) + (225 x 1) (320 x 2) + (250 x 1) (320 x 2) + (250 x 1) (320 x 2) + (312 x 1)
Sound (225 x 1)
Pressure Level Heating dB(A) 68.6 68.7 68.8 69.5 Sound Cooling dB(A) 68.3 68.5 68.6 68.7 68.8
Sound Power Cooling dB(A) 96.4 96.6 97.1 97.4 Pressure Level Heating dB(A) 69.8 70.4 70.5 70.6 70.6
Level Heating dB(A) 100.3 100.5 100.8 101.0 Sound Power Cooling dB(A) 97.4 98.3 98.5 98.6 99.0
mm2 x No. Level Heating dB(A) 101.4 102.2 102.5 102.6 102.8
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) mm2 x No.
Refrigerant Name R410A R410A R410A R410A Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
Precharged Amount Refrigerant Name R410A R410A R410A R410A R410A
kg 40.0 40.0 42.5 42.5
Refrigerant in Factory Precharged Amount
t-CO2 eq. 83.5 83.5 88.7 88.7 kg 42.5 43.5 47.5 47.5 50.0
in Factory
Refrigerant
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 88.7 90.8 99.2 99.2 104.4
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Power Supply Ø, V, Hz Control
Valve Valve Valve Valve Valve
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
042 043
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5
UNITS
MULTI V 5
ARUM680LTE5 / ARUM700LTE5 / ARUM720LTE5 / ARUM740LTE5 / ARUM760LTE5 ARUM780LTE5 / ARUM800LTE5 / ARUM820LTE5 / ARUM840LTE5 / ARUM860LTE5
HP 68 70 72 74 76 HP 78 80 82 84 86
Combination Unit ARUM680LTE5 ARUM700LTE5 ARUM720LTE5 ARUM740LTE5 ARUM760LTE5 Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM820LTE5 ARUM840LTE5 ARUM860LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Independent Unit
ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM240LTE5
ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 190.4 196.0 201.6 207.2 212.8 Cooling (Rated) kW 218.4 224.0 229.6 235.2 240.8
Capacity Heating (Rated) kW 190.4 196.0 201.6 207.2 212.8 Capacity Heating (Rated) kW 218.4 224.0 229.6 235.2 240.8
Heating (Max) kW 211.5 217.8 222.8 230.4 236.7 Heating (Max) kW 243.0 249.3 255.6 260.6 266.9
Cooling (Rated) kW 47.57 50.50 52.20 51.06 53.27 Cooling (Rated) kW 53.29 55.15 58.08 59.78 60.88
Input Heating (Rated) kW 43.98 45.93 47.67 46.76 48.91 Input Heating (Rated) kW 48.75 50.83 52.78 54.52 55.80
Heating (Max) kW 52.28 54.36 56.40 55.58 58.25 Heating (Max) kW 57.80 60.54 62.62 64.66 66.12
EER 4.00 3.88 3.86 4.06 3.99 EER 4.10 4.06 3.95 3.93 3.96
SEER - - - - - SEER - - - - -
Rated Capacity 4.33 4.27 4.23 4.43 4.35 Rated Capacity 4.48 4.41 4.35 4.31 4.32
COP COP
Max. Capacity 4.05 4.01 3.95 4.15 4.06 Max. Capacity 4.20 4.12 4.08 4.03 4.04
SCOP - - - - - SCOP - - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type Type
Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 Combination x No. (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7
Compressor Motor Output x Compressor Motor Output x
W x No. (5,300 x 5) + (4,200 x 1) (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6 W x No. (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) 5,300 x 7 5,300 x 7
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 15,600 15,600 15,600 18,200 18,200 Oil Charge cc 19,500 19,500 19,500 19,500 19,500
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x (900 x 6) + (1,200 (900 x 6) + (1,200
W x No. 900 x 6 900 x 6 900 x 6 (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) W x No. (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8
Number Number x 1) x 1)
Fan Air Flow Rate (High) m3/min x No. 320 x 3 320 x 3 320 x 3 (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) Fan Air Flow Rate (High) m3/min x No. (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Pipe Pipe
Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
Connctions #1 Connctions #1
High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connctions #2 Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Connctions #2 Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4
+ (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(310 x 2) + (237 x 1) + (310 x 2) + (237 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) +
Net Weight kg x No. (310 x 2) + (300 x 1) (310 x 2) + (300 x 1) 310 x 3 Net Weight kg x No. (310 x 3) + (215 x 1) (310 x 3) + (237 x 1)
(215 x 1) (215 x 1) (215 x 1) (215 x 1) (215 x 1)
(320 x 2) + (250 x 1) (320 x 2) + (250 x 1) (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) +
Shipping Weight kg x No. (320 x 2) + (312 x 1) (320 x 2) + (312 x 1) 320 x 3 Shipping Weight kg x No. (320 x 3) + (225 x 1) (320 x 3) + (250 x 1)
+ (225 x 1) + (225 x 1) (225 x 1) (225 x 1) (225 x 1)
Sound Cooling dB(A) 69.0 69.6 69.8 69.1 69.2 Sound Cooling dB(A) 69.2 69.4 70.0 70.1 70.2
Pressure Level Heating dB(A) 71.1 71.3 71.8 70.9 70.9 Pressure Level Heating dB(A) 71.0 71.4 71.6 72.1 72.1
Sound Power Cooling dB(A) 99.2 99.2 99.8 98.8 98.9 Sound Power Cooling dB(A) 99.2 99.4 99.4 99.9 100.1
Level Heating dB(A) 103.0 103.2 103.8 102.7 102.8 Level Heating dB(A) 103.0 103.2 103.4 103.9 104.1
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount Precharged Amount
kg 50.0 50.0 51.0 57.0 57.0 kg 59.5 59.5 59.5 60.5 64.5
in Factory in Factory
Refrigerant Refrigerant
t-CO2 eq. 104.4 104.4 106.5 119.0 119.0 t-CO2 eq. 124.2 124.2 124.2 126.3 134.6
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control Control
Valve Valve Valve Valve Valve Valve Valve Valve Valve Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
044 045
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
OUTDOOR
MULTI V 5 NOTES
UNITS
1. Eurovent Test Condition : For more info regarding program consult www.eurovent-certification.com
MULTI V 5
2. Capacities are based on the following conditions :
• Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
• Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
ARUM880LTE5 / ARUM900LTE5 / ARUM920LTE5 / ARUM940LTE5 / ARUM960LTE5 • Piping Length : Interconnected Pipe Length = 7.5m
HP
• Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
88 90 92 94 96
Combination Unit ARUM880LTE5 ARUM900LTE5 ARUM920LTE5 ARUM940LTE5 ARUM960LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 3. Wiring cable size must comply with the applicable local and national code.
Independent Unit
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 246.4 252.0 257.6 263.2 268.8 4. Sound Level Values can be increased owing to ambient conditions during operation.
Capacity Heating (Rated) kW 246.4 252.0 257.6 263.2 268.8
Heating (Max) kW 273.2 279.5 285.8 292.1 297.0
Cooling (Rated) kW 63.09 63.11 64.97 67.90 69.60 5. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units
Input Heating (Rated) kW 57.95 57.79 59.87 61.82 63.56
combination. The recommended ratio is 130%.
Heating (Max) kW 68.79 68.34 71.08 73.16 75.19
EER 3.91 3.99 3.96 3.88 3.86
SEER - - - - - 6. Explanation of Terms
Rated Capacity 4.25 4.36 4.30 4.26 4.23
COP
Max. Capacity 3.97 4.09 4.02 3.99 3.95 • EER : Energy Efficiency Ratio (Cooling)
SCOP - - - - - • SEER : Seasonal Energy Efficiency Ratio (Refer to Typical Cooling Season)
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior • COP : Coefficient Of Performance (Heating)
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / • SCOP : Seasonal Coefficient Of Performance (Refer to Typical Heating Season)
Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type Part Load Ratio Outdoor Air Temp. (°C (°F)DB) Weighting Coefficients
Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 7 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8
Motor Output x 100% 35 (95) 0.03
Compressor W x No. 5,300 x 7 (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) 5,300 x 8
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) 75% 30 (86) 0.33
Oil Charge cc 19,500 20,800 20,800 20,800 20,800
50% 25 (77) 0.41
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 8 900 x 8 900 x 8 900 x 8 900 x 8 25% 20 (68) 0.23
Number
Fan Air Flow Rate (High) m3/min x No. 320 x 4 320 x 4 320 x 4 320 x 4 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER • Formula : 0.03 x EER100% + 0.33 x EER75% + 0.41 x EER50% + 0.23 x EER25%
Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Pipe
Connctions #1
Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) 7. Due to our policy of innovation some specifications may be changed without notification.
High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connctions #2 Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) 8. This product contains Fluorinated greenhouse gases.
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4
Net Weight kg x No. (310 x 3) + (237 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) 310 x 4
Shipping Weight kg x No. (320 x 3) + (250 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) 320 x 4
Sound Cooling dB(A) 70.3 70.3 70.4 70.9 71.0
Pressure Level Heating dB(A) 72.2 72.2 72.5 72.7 73.0
Sound Power Cooling dB(A) 100.2 100.4 100.6 100.6 101.0
Level Heating dB(A) 104.2 104.3 104.4 104.6 105.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 64.5 67.0 67.0 67.0 68.0
in Factory
Refrigerant
t-CO2 eq. 134.6 139.9 139.9 139.9 142.0
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
046 047
OUTDOOR UNITS _ MULTI V S OUTDOOR UNITS _ MULTI V S _ KEY FEATURES
OUTDOOR
ENERGY SAVING
UNITS
EER / COP / Part Load Inverter Twin Rotary &
Saving Energy Cost with High Efficient Product Inverter Scroll Compressor
Adapted High Efficient Compressor according to Capacity
MULTI V S
Heat Pump
- Air cooled VRF Heat pump & Heat Recovery EER (Cooling) COP (Heating) Inverter Twin Rotary Inverter scroll compressor
- 12.1 ~ 33.6kW (Cooling capacity based) (12.1kw ~ 15.5kw) (22.4kw ~ 33.6kw)
Compressor Efficiency Comparison
- Both 1Φ, 220 ~ 240V, 50 ~ 60Hz and 3Φ, 380 ~ 415V, 50 ~ 60Hz
43%
Efficiency
Scroll Compressor
- Side discharge outdoor unit 16% 3.90 5.30 Rotary Compressor
3.35 3.71
- Includes the industry’s first single phase Heat Recovery system
Conventional MULTI V S HR Conventional MULTI V S HR
300m (MULTI V S H/P)
* Comparison Based on 15.5kW in cooling mode
(MULTI V S H/P)
* Comparison Based on 15.5kW in heating mode
12.1 19.6 28
* Based on internal test data
kw
(Cooling capacity)
TOTAL PIPING LENGTH 150m (175m)
Longest piping length
from ODU ~ IDU (Equivalent) Heat Recovery Inverter Twin Rotary
Cooling Mode Heating Mode Concentrated Winding Motor
Oil path area is improved by over 50% by increasing the extra stator cavity. Due to
Cooling EER is 5% higher than Heating COP is 5% higher than
this, caloric value of motor is reduced, improving the cooling function of stator coil.
Available in Heat Pump and conventional on average. conventional on average.
Heat Recovery Configurations Twin Rotary Rotor
Upper and lower part rotor offset imbalance in shaft rotor rotation. Vibration and
5% 3.90
5% 4.39
noise is reduced. Max torque load decreased by 45% compared to single rotor.
4.18
Energy saving by heat 3.71
recovery unit Surface Coating
Surface coating of outstanding abrasion resistance property on vane and crank shaft.
Conventional MULTI V S HR Conventional MULTI V S HR
(MULTI V S H/P) (MULTI V S H/P)
* Comparison Based on 15.5kW in cooling mode * Comparison Based on 15.5kW in heating mode Inverter scroll compressor
World Best Class Compressor Speed
20
Height Difference
between ODU ~ IDU
Increase comfortable sensation and Max. 23% energy - Down to 15Hz : Part load efficiency improvement 15
Heating and Hot Water Solution Conventional
saving thanks to MULTI V load control 6 By-pass Valve
Compressor reliability is maximized with 6 By-pass Valve
MULTI V S changes indoor discharge air temperature continuously - Prevent compressor damage due to excessively compressed refrigerant more
INDOOR UNIT efficiently than 4 by-pass valve
according to load, to save energy.
SLC (Smart Load Control) operation Direct Oil Injection
Startup Operation Real Time Operation ... - Eliminate suction refrigerant gas heat loss through direct oil injection into
compression chamber (efficiency increases)
HYDRO KIT Startup After 20 minutes
- Reliability increase due to proper oil amount supply
MULTI V S
Heat Reacovery Startup Operation Scroll Profile
- The enhanced reliability by increasing the thickness of scroll central part within largest pressure
* Heat Pump and Recovery are separated models. Basic Operation Smart Load Control - Efficiency increases by expanding 96% bypass area and 17% improved volume ratio by non
uniform scroll thickness
15m Indoor
Discharge Air
Height Difference Temperature
between IDU ~ IDU
Power
Input
Optimal Heat Exchanger
Maximize Efficiency according to different Heat Exchanger
Indoor air discharge temperature
Until 20 minutes after startup operation path by cooling and heating (LG’s own technology)
- Energy efficiency increased by 3-step Smart Load Control during startup phase
- Discharge air temperature adjusted according to outdoor and indoor temperature
- Comfort level in cooling / heating operations ensured
Variable Heat Exchanger Circuit intelligently selects the optimal
path for both heating and cooling operations. With this smart path
Max. 10% Energy saving selection technology, an average of 6% increase in the efficiency of
both operations has been achieved. The paths number and circuit
Real Time Operation velocity are adjusted to match temperatures and operation modes in
Basic Operation Smart Load Control
order to maximize efficiency instead of compromising efficiency for
3°C 10°C each operation when the number and direction of paths are fixed
Refrigerant Refrigerant
independently of temperature operation mode.
20°C 20°C
048 049
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES
OUTDOOR
HIGH RELIABILITY IMPROVED USER CONVENIENCE
UNITS
High Reliability of Refrigerant Components Smart Control Sufficient Pipe Length Limit Fan Technology and RPM Control
Superior Performance and Strong Durable Components are Pressure Control applied for smart, quick, and Sufficient pipes length limitation in Design and External static pressure control for outdoor unit fan to adapt
developed by LG’s technologies precise responds to the user's requested temperature Installation of immense variety of building more flexibly to various installation conditions of outdoor unit
MULTI V S
MULTI V S improved reliability through an excellent technique of Oil Temperature + Pressure Control MULTI V S inverter technology and sub cooling control circuit For efficient operation, newly developed fan blows higher air volume
separator / Accumulator / Sub-cooling. Senses and controls pressure directly technology allows greater piping length and outstanding elevation and has more high static pressure, also operating noise is decreased.
using pressure sensor for faster and more differences. A cooling system can be implemented more flexibly in a
exact response to load variation shop, office and even high-rise building, reducing the designer’s work
Fan Technology
time and providing more efficient design.
The new axial fan has a mogul trailing edge, narrow hub blade and reverse hub,
High Pressure Low Pressure
Sensor Sensor this provides a high efficiency, low noise, wide fan, as well as improving the air
flow rate.
Quick Operating Response Pressure +Temperature Control Piping Capabilities
Temperature Control 300m
Pressure control takes up to 14%
Total piping length Reverse
UL Verified Mark as described below.
40%
Sound Level
Night
50
58
Certificate Number: A022809
Issued To: LG ELECTRONICS INC
Claim Verified: Condenser resists 27 years of simulated severe corrosion
Product / System /
Condenser Employed on Outdoor Unit of Air‐Conditioners
Motor
Process Name:
Details: N/A
56 Step 1
R.H. NO2 SO2
Visit http://verify.ul.com for information on all products/processes/systems that are authorized to bear the UL Verified Mark.
AC
This UL Verified Mark is owned by UL LLC. Permission to use the UL Verified Mark has been granted per this certificate, yet may
be withdrawn at the sole discretion of UL LLC. Subject to the terms and conditions of our Agreements, UL has granted the
limited non-exclusive and non-transferable right to use this UL Verified Mark directly on product and packaging, and/or in
conjunction with materials used to advertise and promote the Verified claim. Any such use shall not imply any Certification or condition + severe industrial/traffic
Easy and convenient maintenance with self-diagnosis
endorsement based on the UL verification process, nor shall the UL Verified Mark be used in any professional, technical, trade,
website or other business publications in order to advertise accomplishments except where the specific product that achieved
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized
95% 10 x 10 -5
5 x 10 -6
licensee of UL. For questions, please contact a UL Customer Service Representative.
050 051
OUTDOOR UNITS _ MULTI V S _ TECHNICAL DATA
OUTDOOR
A 165 620 Piping Direction
UNITS
A Datum Iine
ARU N 100 L S S 0 Piping
Direction Cooling 45°C Heating 20°C
390
360
Serial number 43°C 18°C
40°C 15°C
Model Type
MULTI V S
Air Discharge Type
S : Side Discharge 5 5 20°C 0°C
Electrical Ratings
5 5 15°C -5°C
L : 3Ø, 380-415V, 50Hz / 3Ø, 380V, 60Hz
G : 1Ø, 220-240V, 50Hz / 1Ø, 220V, 60Hz
834
10°C
-10°C
660
627
Total Cooling Capacity in Horse Power(HP) unit
3 5°C
141 466
476
EX) 8HP → '080', 10HP → '100' -15°C
0°C
24
Combination of Inverter Type and Cooling Only B B B
83
or Heat Pump -20°C
51 148 -5°C
N : Inverter and H/P, V : Inverter and C/O 1 64
2 4
416 -10°C -25°C
40
MULTI V System Outdoor Unit using R410A 10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 27°C 30°C
111
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
291
276
Outside Unit Function 5-1.D. Ø 20 holes for drain connection 91
250 Heat Recovery
696
Category Functions MULTI V S A
continuous operation
Anti Corrosion Black Fin ○ 35°C
Range for
5°C
Dual Sensing ARUB060GSS4 only 3D View 25°C
IO Module (ODU Dry Contact) PVDSMN000 Indoor Temperature (°C WB) Indoor Temperature (°C DB)
42
91
PDI (Power Standard PPWRDB000 Note
4 1. These figures assume the following operating conditions : Equivalent piping length : 7.5m
Distribution Indicator) Premium PQNUD1S40 3 Level difference : 0m
Cool / Heat Selector PRDSBM 2. Range of pull down operation : If the relative humidity is too high, cooling capacity can be decreased by the sensible
606
536
557
○ B 25 8
(Logical operation) 3D View 81
1.5m
2. Unit should be grounded in accordance with the 4 Liquid Pipe Connection Welding joint
※ ○ : Applied, - : Not Applied local regulation or applicable national codes. 5 Handle -
3. All electrical components and materials to be 6 Pipe routing hole (front) - 1m
supplied from the site must comply with the local 7 Pipe routing hole (side) -
8 Pipe routing hole (back) -
regulations or international codes.
4. Electrical characteristics chapter should be
considered for electrical work and design.
Especially the power cable and circuit breaker
should be selected in accordance with that.
052 053
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION
OUTDOOR
MULTI V S HEAT PUMP LG participates in the ECP programme for EUROVENT
MULTI V S HEAT PUMP LG participates in the ECP programme for EUROVENT
UNITS
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com
MULTI V S
ARUN040GSS0 / ARUN040GSR0 / ARUN050GSL0 ARUN050GSS0 / ARUN050GSR0 / ARUN060GSS0 / ARUN060GSR0
HP 4 5 HP 5 6
General Model ARUN040GSS0 ARUN050GSL0 General Model ARUN050GSS0 ARUN060GSS0
Model Name Model Name
Corrosion Resistance Model ARUN040GSR0 - Corrosion Resistance Model ARUN050GSR0 ARUN060GSR0
Cooling (Rated) kW 12.1 14.0 Cooling (Rated) kW 14.0 15.5
Capacity Capacity
Heating (Rated) kW 12.5 15.0 Heating (Rated) kW 16.0 18.0
Cooling (Rated) kW 3.78 4.38 Cooling (Rated) kW 3.33 3.97
Input Input
Heating (Rated) kW 2.10 2.65 Heating (Rated) kW 2.77 3.40
EER 3.20 3.20 EER 4.20 3.90
SEER 5.98 6.60 SEER 6.56 6.65
COP Rated Capacity 5.9 5.7 COP Rated Capacity 5.77 5.30
SCOP 5.15 4.96 SCOP 5.23 5.19
Color (General) Warm Gray Warm Gray Color (General) Warm Gray Warm Gray
Color (Corrosion Resistance) Morning Gray - Color (Corrosion Resistance) Morning Gray Morning Gray
Exterior Exterior
RAL Code (Classic), General RAL 7044 RAL 7044 RAL Code (Classic), General RAL 7044 RAL 7044
RAL Code (Classic), Corrosion Resistance RAL 7030 - RAL Code (Classic), Corrosion Resistance RAL 7030 RAL 7030
Heat Heat
Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Exchanger Exchanger
Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary
Combination x No. (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1 Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 1,300 1,300 Oil Charge cc 1,300 1,300
Type Axial Flow Fan Axial Flow Fan Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W x No. 124 x 1 124 x 1 Motor Output x Number W x No. 124 x 2 124 x 2
Fan Air Flow Rate (High) m3/min x No. 60 x 1 60 x 1 Fan Air Flow Rate (High) m3/min x No. 110 x 1 110 x 1
Drive DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side Discharge Side / Top Side Side
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8)
Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4)
Dimensions (W x H x D) mm x No. (950 x 834 x 330) x 1 (950 x 834 x 330) x 1 Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,065 x 918 x 461) x 1 (1,065 x 918 x 461) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1
Net Weight kg x No. 70 x 1 73 x 1 Net Weight kg x No. 94 x 1 94 x 1
Shipping Weight kg x No. 77 x 1 81 x 1 Shipping Weight kg x No. 106 x 1 106 x 1
Sound Cooling dB(A) 50.0 52.0 Sound Cooling dB(A) 51.0 52.0
Pressure Level Heating dB(A) 52.0 58.0 Pressure Level Heating dB(A) 53.0 54.0
Sound Power Cooling dB(A) 72.0 72.0 Sound Power Cooling dB(A) 72.0 72.0
Level Heating dB(A) 75.0 75.0 Level Heating dB(A) 76.0 77.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A Refrigerant Name R410A R410A
Precharged Amount in Precharged Amount in
kg 1.8 2.4 kg 3.0 3.0
Refrigerant factory Refrigerant factory
t-CO2 eq. 3.8 5.0 t-CO2 eq. 6.3 6.3
Control Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve
1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60 1, 220, 60
Number of Maximum Connectable Indoor Units 8 8* Number of Maximum Connectable Indoor Units 10 13
* : In case of ARUN050GSL0, maximum combination ratio is 130%. Note : 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
Note : 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct. - Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT certification regulation for more detail test conditions. - Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors. 2. Performances are based on the following conditions :
2. Performances are based on the following conditions : - Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB - Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB 3. The maximum combination ratio is 160%.
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.) 4. Wiring cable size must comply with the applicable local and national codes.
4. Wiring cable size must comply with the applicable local and national codes. 5. Due to our policy of innovation some specifications may be changed without notification.
5. Due to our policy of innovation some specifications may be changed without notification. 6. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation.
6. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation. 7. Power factor could vary less than ±1% according to the operating conditions.
7. Power factor could vary less than ±1% according to the operating conditions. 8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
054 055
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION
OUTDOOR
MULTI V S HEAT PUMP LG participates in the ECP programme for EUROVENT
MULTI V S HEAT PUMP LG participates in the ECP programme for EUROVENT
UNITS
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com
MULTI V S
ARUN040LSS0 / ARUN050LSS0 / ARUN060LSS0 ARUN080LSS0 / ARUN100LSS0 / ARUN120LSS0
ARUN040LSR0 / ARUN050LSR0 / ARUN060LSR0
HP 4 5 6 HP 8 10 12
General Model ARUN040LSS0 ARUN050LSS0 ARUN060LSS0 General Model ARUN080LSS0 ARUN100LSS0 ARUN120LSS0
Model Name Model Name
Corrosion Resistance Model ARUN040LSR0 ARUN050LSR0 ARUN060LSR0 Corrosion Resistance Model - - -
Cooling (Rated) kW 12.1 14.0 15.5 Cooling (Rated) kW 22.4 28.0 33.6
Capacity Capacity
Heating (Rated) kW 12.5 16.0 18.0 Heating (Rated) kW 24.5 30.6 36.7
Cooling (Rated) kW 2.37 3.33 3.97 Cooling (Rated) kW 8.30 8.75 14.00
Input Input
Heating (Rated) kW 1.93 2.77 3.40 Heating (Rated) kW 6.62 8.12 7.46
EER 5.10 4.20 3.90 EER 2.70 3.20 2.40
SEER 6.46 6.56 6.65 SEER 6.03 6.59 5.72
COP Rated Capacity 6.49 5.77 5.30 COP Rated Capacity 3.70 3.77 4.92
SCOP 5.02 5.23 5.19 SCOP 4.33 4.17 3.86
Color (General) Warm Gray Warm Gray Warm Gray Color (General) Warm Gray Warm Gray Warm Gray
Color (Corrosion Resistance) Morning Gray Morning Gray Morning Gray Color (Corrosion Resistance) - - -
Exterior Exterior
RAL Code (Classic), General RAL 7044 RAL 7044 RAL 7044 RAL Code (Classic), General RAL 7044 RAL 7044 RAL 7044
RAL Code (Classic), Corrosion Resistance RAL 7030 RAL 7030 RAL 7030 RAL Code (Classic), Corrosion Resistance - - -
Heat Heat
Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Exchanger Exchanger
Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1 4,000 x 1 Compressor Motor Output x Number W x No. 4,200 x 1 5,300 x 1 5,300 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 1,300 1,300 1,300 Oil Charge cc 2,400 2,600 3,400
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 124 x 2 124 x 2 124 x 2 Motor Output x Number W x No. 124 x 2 250 x 2 250 x 2
Fan Air Flow Rate (High) m3/min x No. 110 x 1 110 x 1 110 x 1 Fan Air Flow Rate (High) m3/min x No. 140 x 1 190 x 1 190 x 1
Drive DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top Side Side Side Discharge Side / Top Side Side Side
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 19.05 (3/4) Connctions Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1 Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (1,090 x 1,625 x 380) x 1 (1,090 x 1,625 x 380) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,215 x 1,795 x 500) x 1 (1,215 x 1,795 x 500) x 1
Net Weight kg x No. 96 x 1 96 x 1 96 x 1 Net Weight kg x No. 115 x 1 144 x 1 157 x 1
Shipping Weight kg x No. 108 x 1 106 x 1 106 x 1 Shipping Weight kg x No. 127 x 1 160 x 1 173 x 1
Sound Cooling dB(A) 50.0 51.0 52.0 Sound Cooling dB(A) 57.0 58.0 60.0
Pressure Level Heating dB(A) 52.0 53.0 54.0 Pressure Level Heating dB(A) 57.0 58.0 60.0
Sound Power Cooling dB(A) 72.0 72.0 72.0 Sound Power Cooling dB(A) 81.0 80.0 81.0
Level Heating dB(A) 76.0 76.0 77.0 Level Heating dB(A) 84.0 84.0 85.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 3.0 3.0 3.0 kg 3.5 4.5 6.0
Refrigerant factory Refrigerant factory
t-CO2 eq. 6.3 6.3 6.3 t-CO2 eq. 7.3 9.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 8 10 13 Number of Maximum Connectable Indoor Units 13 16 20
Note : 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct. Note : 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions. - Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors. - Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions : 2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB - Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB - Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
3. The maximum combination ratio is 160%. 3. The maximum combination ratio is 160%.
4. Wiring cable size must comply with the applicable local and national codes. 4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification. 5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation. 6. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions. 7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5) 8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
056 057
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION OUTDOOR UNITS _ MULTI V S _ APPLICATION GUIDE
OUTDOOR
MULTI V S HEAT RECOVERY LG participates in the ECP programme for EUROVENT
MULTI V S APPLICATION GUIDE
UNITS
VRF program. Check ongoing validity of certification
: www.eurovent-certification.com
System Diagram
Providing a total solution by heat pump, air conditioning (cooling by refrigerant & chilled water, heating by refrigerant & hot water)
and domestic hot water supply.
MULTI V S
Air conditioning
Refrigerant piping
Indoor Unit
Water piping
ARUB060GSS4 Hot water
Domestic
supply
Hot Water
HP 6 Tank
Model Name ARUB060GSS4
Cooling (Rated) kW 15.5
Capacity HR Unit
Heating (Rated) kW 18.0
Cooling (Rated) kW 3.97
Input
Heating (Rated) kW 4.10
EER 3.90
SEER 6.84
COP Rated Capacity 4.39
SCOP 4.38 Heat Recovery HYDRO KIT
Color Warm Gray
Exterior
RAL Code (Classic) RAL 7044 Floor heating
Heat
Type Wide Louver Plus
Exchanger
Type Hermetically Sealed Scroll Energy Saving
Combination x No. (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 Energy consumption can be reduced since absorbed heat from indoor space is used for supplying hot water.
Oil Type FVC68D (PVE)
Oil Charge cc 1,700
Type Axial Flow Fan Conventional
Motor Output x Number W x No. 124 x 2 Absorbed heat is released to outdoor air.
m3/min x
Fan Air Flow Rate (High) 110 x 1
No.
Drive DC INVERTER
Discharge Side / Top Side Heat Heat Transfer
Released
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8)
Connctions Low Pressure Gas Pipe mm (inch) Ø 19.05 (3/4)
#1 High Pressure Gas Pipe mm (inch) Ø 15.88 (5/8) Heat
Absorption
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1
Dimensions (W x H x D) - shipping mm x No. (1,140 x 1,549 x 466) x 1
Net Weight kg x No. 118 x 1
Hot water
Shipping Weight kg x No. 132 x 1
Sound Cooling dB(A) 56.0
Pressure Level Heating dB(A) 58.0 Conventional Boiler Domestic
(Gas or Electric) Hot Water Tank Hot Water Supply Cooling
Sound Power Cooling dB(A) 80.0
Level Heating dB(A) 84.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C
(VCTF-SB)
Refrigerant Name R410A MULTI V S Heat Recovery with HYDRO KIT
Precharged Amount in
kg 3.5
Absorbed heat from indoor space is used for making hot water.
Refrigerant factory
t-CO2 eq. 7.3
Control Electronic Expansion Valve
1, 220 ~ 240, 50 Heat Transfer
Power Supply Ø, V, Hz
1, 220, 60
Number of Maximum Connectable Indoor Units 13 HR Unit
Note : 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct. Heat
- Refer to EUROVENT certification regulation for more detail test conditions. Absorption
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB Hot water
3. The maximum combination ratio is 160%.
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification. HYDRO KIT Domestic
6. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation. Hot Water Tank
7. Power factor could vary less than ±1% according to the operating conditions. Heat Recovery Hot Water Supply Cooling
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
058 059
OUTDOOR UNITS _ MULTI V M OUTDOOR UNITS _ MULTI V M _ KEY FEATURES
OUTDOOR
HIGH CLASS EFFICIENCY
UNITS
World best inverter compressor, smart load control and
wide louver plus fin make world class high efficiency
MULTI V M
- Air Cooled VRF Heat Pump Cooling Efficiency (EER) Heating Efficiency (COP) + Corrosion Resistance
- 14kW (Cooling capacity based) Wide Louver Plus fin technology increases efficiency and heating
- 3Φ, 380 ~ 415V, 50 ~ 60Hz (Compressor Module) 2.6% performance compared to conventional fin.
- 1Φ, 220 ~ 240V, 50 ~ 60Hz (Heat Exchanger Module) 6.2%
3.40 3.80 3.90
- Outdoor unit is installed inside building 3.20
A Company
Module type
MULTI V M
(Eurovent)
A Company
Module type
MULTI V M
(Eurovent)
+
70m 140m
Longest piping length from Compressor TOTAL PIPING LENGTH
Module to Indoor unit New Type Scroll Conventional 100%
MULTI V M ensures world’s best class energy efficiency with
innovative technology including the LG’s New Type Scroll compressor. Wide Louver
Plus Fin 128% 28%
(Cooling)
Direct Inlet / Outlet Case
Wide Louver
Motor Plus Fin 123% 23%
Indoor unit (Heating)
Heat exchange rate (%)
Heat
exchanger
3°C 10°C
REGULATORY COMPLIANCE
Building permit could be simplified
Regulation in Spain
Indoor Discharge
Air Temperature
During Start up Weather Dependent
Changed by
Indoor Temperature
Exposure regulation of
Features & Benefits Key Applications outdoor unit on wall
installation
Power Input
• Flexible Design & Installation • Regulation that Outdoor Unit should be Installed Inside Building
• Space & Installation Cost Saving • Lack of Installation Space at Restaurant, Retail Shop
• Easy Maintenance • Do Not Want to Expose the Outdoor Unit for Safety Reason or Aesthetic Design
• Building Permit could be Simplified • Building Nearby that could Cause Noise Problem or Historic City Centers
Time
• Can only be installed inside the building
Up to 30% Energy Saving • Discharge air volume less than 60CMM
Smooth (Level1) SLC Contol
• Securing more than 5m distance between outdoor discharge grilles
SLC Start up
Quick (Level 2) Basic Operation (Default Setting)
• Securing at least 2.5m from the floor
Operation
Power (Level 3)
• Securing more than 2.5m from surrounding windows
060 061
OUTDOOR UNITS _ MULTI V M _ KEY FEATURES OUTDOOR UNITS _ MULTI V M _ TECHNICAL DATA
OUTDOOR
FLEXIBLE DESIGN &
UNITS
[Unit : mm] C
ARU N 050 L M S 0
101
S : Set
C : Compressor Module
Module Type Heat exchanger module can be installed in false ceiling spaces E : Heat Exchanger Module
500
A
MULTI V M
Outside Unit Type
216
Increased freedom of design M : Modular Type
Electrical Ratings
- Additional structure installation and ceiling construction isn’t L : 3Ø, 380-415V, 50Hz / 3Ø, 380V, 60Hz 580
required G : 1Ø, 220-240V, 50Hz / 1Ø, 220V, 60Hz
Ease of service (Replacement of the comp) Total Cooling Capacity in Horse Power(HP) unit B
EX) 5HP → '050', 8HP → '080'
Low noise by module (vs Integrated Type) Combination of Inverter Type and Cooling Only
or Heat Pump
N: Inverter and H/P, V: Inverter and C/O
MULTI V System Outdoor Unit using R410A
700
Outside Unit Function
512
512
Heat Exchanger
352
Module Category Functions Modular
Variable Path of Outdoor Unit HEX -
HiPORTM (High Pressure Oil Return) -
Max. Key Refrigerant
Humidity Sensor -
249 327 249
10 indoor units Components
Anti Corrosion Black Fin ○ Left Front Right
Max.70m
Compressor module can be installed at any place inside Oil Sensor -
Max.30m Dual Sensing - D
Compressor
19
Low Noise Operation ○
Module Hgih Static Mode of Outdoor Unit Fan ○
15
22.5
Ø15
7.5
Partial Defrosting -
462
Auto Dust Cleaning of Outdoor Unit
-
Useful Function (Fan reverse rotation) Detail D
Indoor Cooling Comfort Mode Based
○
Outdoor Temperature
19
Smart Load Control (SLC) 25 530 25
(Changing indoor discharge air ○
Flexible Piping Location temperature according to load)
Outdoor Unit Control Refer to Humidity -
Defrost / Deicing ○
Neat & easy installation by flexible piping location piping.
High Pressure Switch ○
Phase Protection ○
Reliability Restart Delay (3-minutes) ○
Top side piping
Self Diagnosis ○
Soft Start ○
Test Run Function -
122
AC Ez (Simple Controller) PQCSZ250S0
AC Ez Touch PACEZA000 150 30
AC Smart IV PACS4B000
Volume Installation
Refrigerant Charging Kit
Variable Water Flow Valve Control Kit
-
-
1622
1397
19
Increased Freedom of Design Compressor Module Heat Exchanger Module PDI (Power Distribution Standard
Indicator) Premium
-
-
560
Additional structure installation or ceiling construction isn’t required 0.233 m3
Cool / Heat Selector PRDSBM
0.826 m3
300
Low Ambient Kit -
due to improved freedom of design. This makes replacement of
IO Module
19
PVDSMN000
the compressor easier, making the service and maintenance of A Company (ODU Dry Contact) 850
0.603 m3 Cycle Monitoring LGMV PRCTIL0
products handy. Moreover, split module provides low noise operation 3
0.203 m
A Company B Company Device Mobile LGMV PLGMVW100
in comparison to the integrated type. 0.494 m3
LG ※ ○ : Applied, - : Not Applied
292
LG 29 28 69 335 314 335
294
462
393
Heat Pump
352
352
357
352
352
222
Heat exchanger Cooling Heating 221 1122 219 551
555
1562
E.S.P. (External Static Pressure) Control
113
22
95
45°C 20°C 625
111
43°C 18°C
Compressor 40°C 15°C
242 170
up to 30 Pa up to 157 Pa
20°C 0°C
10°C
-10°C
1389
5°C
-15°C
Normal Mode High Static Pressure Mode 0°C
388
-20°C
-5°C
-10°C -25°C
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 27°C 30°C
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
062 063
OUTDOOR UNITS _ MULTI V M _ TECHNICAL DATA OUTDOOR UNITS _ MULTI V M _ SPECIFICATION
OUTDOOR
MULTI V M LG participates in the ECP programme for EUROVENT
UNITS
[ C omp r essor Mod ule] [ H ea t Ex c h a ng er Mod ule] VRF program. Check ongoing validity of certification
: www.eurovent-certification.com
Compressor Module Heat Exchanger Module
[ C omp r essor Mod ule] [ H ea t Ex c h a ng er Mod ule]
Microphone DISCHARE SUCTION
DUCT DUCT
MULTI V M
1.5 m
1.5 m
2m 2m
1.0 m
System
* Measuring place : Anechoic chamber * Measuring place : Anechoic chamber HP 5
I nsta lla tion S p a c e f or C omp r essor Mod ule Set ARUN050LMS0
Model Name Compressor Module ARUN050LMC0
Heat Exchanger Module ARUN050GME0
I nsta lla tion S p a c e f or C omp r essor Mod ule Cooling* (Rated) kW 14.0
Capacity Heating* (Rated) kW 14.0
Installation Space for Compressor Module
I nsta lla tion S p a c e f or C omp r essor Mod ule
Heating* (Max.) kW 16.0
Cooling* (Rated) kW 4.12
b a Input Heating* (Rated) kW 3.59
Top View Front View
Heating* (Max.) kW 4.32
c EER Based on Rated Capacity 3.40
SEER 7.03
e Based on Rated Capacity 3.90
COP
Based on Max. Capacity 3.70
SCOP 4.12
on S p a c e f or C omp r essor Mod ule
Number of Maximum Connectable Indoor Units 10
Front Side
Module
HP 5
Compressor Module Heat Exchanger Module
Service Space Model Names
ARUN050LMC0 ARUN050GME0
(Front Side)
d Color Morning Gray -
Exterior
RAL Code (Classic) RAL 7030 -
Top View F r ont View
Dimensions Net mm x No. 580 x 700 x 500 1,562 x 460 x 688
(W x H x D) Shipping mm x No. 618 x 833 x 564 1,806 x 537 x 825
I nsta lla tion S p a c e
C a tegTopor y View Ma r k Desc r F ip r ont
tionView Net kg x No. 69 x 1 84 x 1
[ mm ] Weight
a Right 10 or more Shipping kg x No. 76 x 1 95 x 1
b Lef t I nsta lla tion S p a c e 10 or more Type Hermetic Motor Compressor -
Category C a teg Top y View
orMark C Maompressor
rk Desc
c r ipF Description
r tion
ont View
Rear
Installation Space (mm)
10 or more
M odul e [ mm ] Combination x No. (Inverter) x 1 -
a a d Right Right F ront 10 or more 10 or More500 or more Compressor Motor Output W x No. 3,200 -
C a teg or y b e Lef t Left I nsta lla tion T opS p a c e 10 or more 10 or More200 or more
C Maompressor
rk Desc r ip tion
b Oil Type FVC68D (PVE) -
Compressor c Rear Rear [ mm ] 10 or more 10 or More Oil Charge cc 1,300
M a odul ec Right 10 or more
Module
b d
I nstad lla Ltion ef t S p a c e f or F H roeant Front
t Ex c h a ng10 er
or m Mod 500 or more
ore ule 200 or more500 or More
Heat Exchanger Type - Wide Louver Plus / Black Fin
C ompressor e T op Type - Sirocco Fan
M odul e c e
Rear Top View Top
10 or more 200 or More
d F ront 500 or more Fan Motor Output x Number W x No. - 400 x 2
Top View
I nstae lla tion S p a c eF r f ontor HView
T oeap t Ex c h a ng er Mod ule 200 or more Air Flow Rate (Rated) m3/min x No. - 60
External Static Nominal (Rated, Factory Set) mmAq (Pa) - 3 (29)
Top View Pressure
I nsta lla tion S p a c e f or H ea t Ex c h a ng er Mod
I nsta ule
lla tion S p a c e
Max. mmAq (Pa) - 16 (157)
Ma r k Desc r ip tion Liquid mm (inch) Ø 9.52 (3/8) to IDU Ø 12.7 (1/2) to Comp. Module
[ mm ]
a RTopight View 10 or more Pipe Connctions Gas mm (inch) Ø 15.88 (5/8) to IDU Ø 19.05 (3/4) to Comp. Module
b Lef t 10 or more Drain mm (inch) - Ø 25 (1)
sor
c Rear 10 or more Sound Pressure Cooling (Rated) dB(A) 45.0 45.0
d F ront 500 or more Level Heating (Rated) dB(A) 45.0 45.0
Installation
e Space for
T opCompressor Module 200 or more Sound Power Level dB(A) 59.0 66.0
[Unit: mm] mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C to IDU 1.0 ~ 1.5 x 2C to Comp. Module
(VCTF-SB)
on S p a c e f Top
or H View
ea t Ex c h a ng er Mod ule Front View
[Unit : mm] [Unit : mm]
Refigerant Name R410A R410A
Top View Air Suction
[Unit: mm]
600 x 600 Precharged Amount kg 2.0 -
(Service Inspection Hole) F r ont View Refrigerant
t-CO2 eq. 4.175 -
[Unit: mm]
10 or More
064 065
[Unit: mm]
OUTDOOR UNITS _ MULTI V WATER IV OUTDOOR UNITS _ MULTI V WATER IV _ KEY FEATURES
OUTDOOR
KEY FEATURES ENERGY SAVING
UNITS
High Efficiency System Regardless of Economical, Highly Efficient System
External Conditions LG’s key technologies are integrated to inverter compressor
MULTI V WATER IV
Regardless of outdoor temperature and other environmental conditions, Adopting a water-based cooling method, this unit optimizes
MULTI V WATER IV is the optimal solution. performance in comparison to compressor capacity. It also ensures
heat exchange performance for high-rise buildings, thus allowing
- Water Cooled VRF Heat Pump & Heat Recovery
electrical-savings.
- 22.4 ~ 201.6kw (Cooling capacity based)
- 3Φ, 380 ~ 415V, 50 ~ 60Hz Extended Compressor Speed 20Hz ~ 140Hz
- Outdoor unit installed indoor Independant Weather Condition - Rapid operation response
- Capable of reaching required temperature quickly
- Increase part load efficiency
COP
Uses underground heat sources such as soil, ground water, lake, river, Maximum COP 8.5
7
Heating based etc. as renewable energy for cooling and heating of a building. Water
Simultaneous operation
or antifreeze solution is circulated through the closed loop HDPE (High 6
External energy saving by between
heat recovery system Density Poly-Ethylene) pipes buried beneath the earth’s surface. It is a
Longest piping length after 1st branch 5
40m highly efficient and using renewable energy.
(Conditional application) Cooling based Heating based
4
operation operation
- The Circulating water temperature range is between -5°C ~ 45°C
0
Cooling based
40m Simultaneous operation - Antifreeze should be applied depending on the application. 20 40 60 80 100 Operation Ratio (%)
Height between * Please contact local LG office for application availability. * Outside unit water inlet temperature : 7°C
IDU ~ IDU Geothermal Application * Indoor temperature : 20°C DB / 15°C WB
* Maximum COP Condition : Cooling 40% + Heating 60% operation
37℃
Efficiency (EER)
Longest piping length after 1st 5.5 5% HEX Optimization
branch (Conditional application)
40m (90m) 10%
2% Cycle Composition
Chiller - FCU MULTI V WATER IV
Height between ODU ~ IDU 50m Improvement
5.0
Cooling Tower 1% Inverter Control
Height between IDU ~ ODU 40m Cooling Tower (Open type cooling towers can be used.)
1% Active Oil Control
Ref. 1% HiPOR™
pipe.
(Independent
control)
Efficiency (EER)
• Independent Weather Condition • Large Scale Office with Curtain Wall AHU 13% 6.7 6% HEX Optimization
4% Cycle Composition
• Utilizing Renewable Source • Building using Geothermal & Various Water Heat Source MULTI V
WATER IV Improvement
• Replacement of Chiller-FCU System • Luxurious Residential Building Water Water piping 5.8 1% Inverter Control
Cooled Chiller Pump Pump Boiler Boiler 1% Active Oil Control
• Seaside Building
(Space Saving) 1% HiPOR™
Water piping Pump
066 067
OUTDOOR UNITS _ MULTI V WATER IV _ KEY FEATURES OUTDOOR UNITS _ MULTI V WATER IV _ TECHNICAL DATA
OUTDOOR
WATER SAVING FLEXIBLE DESIGN & Nomenclature Operation Limits
UNITS
ARW N 100 L A S 4
45 45
Supporting your buildings to become greener
MULTI V WATER IV
The world’s first variable water flow control system for water cooled World’s largest capacity makes it easy to apply to large A : Basic Function
operation
30
VRF system. LG applied Variable Water Flow Control to optimise building and large systems.
30
Electrical Ratings
water flow control regarding partial cooling or heating load conditions. L : 3Ø, 380 ~ 415 V, 50Hz / 3Ø, 380V, 60Hz
25
25
Because of this it’s also possible to reduce circulation pump energy Providing 8 ~ 20HP (22.4 ~ 56kW) with single unit, and up to the 20
Total Cooling Capacity in Horse
consumption. world’s largest capacity 80HP (224kW) by combination. 20
Power(HP) unit
15
EX) 10HP → '100'
HP 8 10 14 20 22 24 28 30 34 40 42 ~ 60 62 ~ 80 15 Range for
10 operation
kW 22.4 28 39.2 56 61.6 67.2 78.4 84 95.2 112 117.6 ~ 168 173.6 ~ 224 Range for
Combination of Inverter Type and Cooling Only operation
or Heat Pump 10 -5
Variable Water 10 15 20 25 30 10 15 20 25 30
Flow Control Valve N: Inverter and H/P
LG Indoor Temperature (°CWB) Indoor Temperature (°CDB)
CoolingTower DC 0 ~ 10V MULTI V Water System with Outside Unit
1 Unit 2 Units 3 Units 4 Units using R410A
Note
1. These figures assume the following operating conditions:
2. Equivalent piping length :7.5m
Inverter Longest Piping Length 3. Level difference : 0m
Geothermal
Pump
Sufficient pipes length limitation in Design and Installation Outside Unit Function
PWFCKN00 of immense variety of building Category Functions MULTI V WATER IV
Variable Path of Outdoor unit HEX -
River / Sea Provide flexible installation up to 300m of total piping length.
HiPORTM (High Pressure Oil Return) ○ Position of Sound Pressure Level
As water pipes are not connected to indoor units, users are free Key Refrigerant
Humidity Sensor -
from water leakage problems. Components
Anti Corrosion Black Fin -
Total Water Flow (m3)
Oil Sensor ○
15,456 Longest piping length Height Dual Sensing -
after 1st branch difference 50m Low Noise Operation -
71%
Hgih Static Mode of Outdoor Unit Fan -
Height
Partial Defrosting -
between IDU
Auto Dust Cleaning of Outdoor Unit
-
Useful Function (Fan reverse rotation)
4,439 Indoor Cooling Comfort Mode Based
-
Outdoor Temperature
Total Piping Length 300m
Smart Load Control (SLC)
Constant Water Flow Variable Water Flow Actual longest piping length (Equivalent) 150m (175m) (Changing indoor discharge air -
Longest piping length after 1 branch (Conditional application)
st
40m (90m) temperature according to load)
Note Note
1. Location : Paris, France Height difference between ODU ~ IDU 50m Outdoor Unit Control Refer to Humidity - 1. Data is valid at free field condition
2. Office, 68,000m2 2. Data is valid at nominal operating condition
Height difference between IDU ~ IDU 40m Defrost / Deicing - 3. Sound level will vary depending on a range of factors such as the construction
3. Operation time : 1,344 hours (cooling period)
High Pressure Switch ○ (acoustic absorption coefficient) of particular room in which the equipment is installed
4. Sound level can be increased in static pressure mode or air guide application.
Phase Protection ○
Conventional MULTI V WATER IV Central Controller AC Smart 5 PACS5A000 1 Y branch pipe ARBLN07121
ACP (Advanced Control Platform) IV PQCPC22A0
2,600,518 36% 61% ARBLN14521
[100%] Reduced ACP (Advanced Control Platform) 5 PACP5A000
ARBLN23220
AC Manager 5 PACM5A000
28kW x 4EA 56kW x 2EA ACP Lonworks PLNWKB000 ARBL054
1,653,093 BNU (Building
Per each Per each Network Unit) ACP BACnet PQNFB17C0 ARBL057
880 x 550 mm 755 x 500 mm
Refrigerant Charging Kit - ARBL104
Installation 2 Header
* 112kw, Floor area based Variable Water Flow Valve Control Kit PWFCKN000 ARBL107
PDI (Power Standard PPWRDB000
ARBL1010
Distribution Indicator) Premium PQNUD1S40
Constant Pump Inverter Pump
Light Weight Cool / Heat Selector PRDSBM
ARBL2010
Nothing or Decrease additional load reinforcement work at building Low Ambient Kit - ARCNN21
5 years 10 years
IO Module (ODU Dry Contact) PVDSMN000 3 Connection pipe of Outdoor Units ARCNN31
Unit Energy Use Pump Running Energy Use Pump Running Easier to transport and install thanks to 18% reduction in overall weight.
Cycle Monitoring LGMV PRCTIL0 ARCNN41
(kWh) Cost ($) (kWh) Cost ($)
Device Mobile LGMV PLGMVW100
Constant pump 7,952,040 1,142,441 15,904,080 2,600,518 18% 127kg
Reduced
MULTI V WATER IV ※ ○ : Applied, - : Not Applied
Inverter pump 5,054,940 726,225 10,109,880 1,653,093 154kg
Previous Model
• Power consumption rate : 0.13$/kWh
• Annual power consumption rate expected to increase by 5% * Based on 28kW
068 069
OUTDOOR UNITS _ MULTI V WATER IV _ TECHNICAL DATA
OUTDOOR
MULTI V WATER IV Heating Dissipation Value by Model Precaution of Installation
REFERENCE SITE
UNITS
Model HP Heating Dissipation Value 1. Do not install the unit at the outdoors. (Otherwise it may
ARWN080LAS4 8 600 W 515.9 kcal/h 0.143 kcal/s cause fire, electric shock and trouble.) Recommended ambient
ARWN100LAS4 10 630 W 541.7 kcal/h 0.150 kcal/s
temperature of outdoor unit is between 0 ~ 40°C Bouygues Challenger
ARWN120LAS4 12 660 W 567.5 kcal/h 0.158 kcal/s 2. Keep the water temperature between 10 ~ 45°C. Otherwise it LG MULTI V WATER Solution with Geothermal Application
may cause the breakdown. Standard water supply temperature is
MULTI V WATER IV
ARWN140LAS4 14 690 W 593.3 kcal/h 0.165 kcal/s
ARWN160LAS4 16 700 W 601.9 kcal/h 0.167 kcal/s 30°C for cooling and 20°C for heating.
ARWN180LAS4 18 720 W 619.1 kcal/h 0.172 kcal/s 3. Establish an anti-freeze plan for the water supply when the
ARWN200LAS4 20 750 W 644.9 kcal/h 0.179 kcal/s product is stopped during the winter.
Test condition : 1) Indoor air temperature : DB 40℃, WB : 32℃
※ A design stage should be considered to ventilation system in mechanical room. 4. Be careful of the water purity control. Otherwise it may cause
the breakdown due to water pipe corrosion. Refer to ‘Standard
Table for Water Purity Control’ in PDB (Product Data Book)
ARWN080LAS4 / ARWN100LAS4 / ARWN140LAS4 5. The water pressure resistance of the water pipe system of this
/ ARWN200LAS4 product is 1.98MPa
[Unit : mm]
755 6. Always install a trap so that the drained water does not back flush
9. Install a service port to clean the heat exchanger at the each end
of the water inlet and outlet.
Liquid pipe 79
Gas pipe 79
High/Low pressure 10. It is recommended to install the flow switch to the water
Common 79
Water pipe outlet
collection pipe system connecting to the outdoor unit. (Flow switch
58 acts as the 1st protection device when the heat water is not
997
supplied.)
913
828
742
635
Water
pipe inlet product with default set value to satisfy the minimum flow rate of
169
this product. (The minimum flow rate range of this product is 50%.)
95
345 250
378
500
12. To protect the water cooling type product, you must install a
755
strainer with 50 mesh or more on the heat water supply pipe.
If not installed, it can result in damage of heat exchanger by the
following situation.
Individual Installation
1) Heat water supply within the plate type heat exchanger is
composed of multiple small paths.
2) If you do not use a strainer with 50 mesh or more, alien
particles can partially block the water paths.
3) When running the heater, the plate type heat exchanger plays Site Information
the role of the evaporator, and at this time, the temperature The industrial group Bouygues was established in France in 1952. It now maintains operations in 80 countries and employs more than 131,000 people.
of the refrigerant side drops to drop the temperature of the In 1988, after two years of construction, the new headquarters for Bouygues Construction was officially opened for business. Named Challenger, the
heat water supply, which can result in icing point in the water complex became a technological showcase for late 20th century architecture.
paths.
4) As the heating process progresses, the water paths can
be partially frozen to lead to damage in plate type heat
exchanger.
5) As a result of the damage of the heat exchanger from the LG Solution
freezing, the refrigerant side and the heat water source side Bouygues decided to convert their headquarters into an eco-friendly building by significantly reducing its energy footprint. The LG MULTI V Water system
will be mixed to make the product unusable. was chosen as the ideal HVAC solution for this project. The system not only saves energy but also reduces water usage as it recycles water in order to
regulate the temperature of the building. With LG’s advanced technology, the building’s water consumption was reduced by more than 70 percent.
Water Piping Installation
070 071
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP
UNITS
ARWN080LAS4 / ARWN100LAS4 / ARWN140LAS4 ARWN200LAS4 / ARWN160LAS4 / ARWN180LAS4
MULTI V WATER IV
HP 8 10 14 HP 20 16 18
Combination Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 Combination Unit ARWN200LAS4 ARWN160LAS4 ARWN180LAS4
Model Name Model Name
Independent Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 ARWN080LAS4 ARWN100LAS4
Independent Unit ARWN200LAS4
ARWN080LAS4 ARWN080LAS4
Cooling (Rated) kW 22.4 28.0 39.2
Capacity Cooling (Rated) kW 56.0 44.8 50.4
Heating (Rated) kW 25.2 31.5 44.1 Capacity
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 3.86 5.09 7.84
Input Cooling (Rated) kW 11.20 7.72 8.95
Heating (Rated) kW 4.2 5.34 8.17 Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.80 5.50 5.00
EER 5.00 5.80 5.63
COP Rated Capacity 6.00 5.90 5.40
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45 Maximum Pressure
Heat Exchanger Resistance kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 77 96 135
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1 Motor Output x
Number Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Oil Charge cc 3,000 5,600 5,600
Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Pipe Connctions Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 12.7 (1/2) Ø 12.7 (1/2)
Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 25.4 (1) Pipe Connctions
Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) Inlet A (inch) 40A(PT 1-1/2) (Internal Thread)
Pipes (Internal Thread) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) Outlet A (inch) 40A(PT 1-1/2) (Internal Thread)
Pipes (Internal Thread) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Cooling dB(A) 47.0 50.0 58.0
Sound Pressure Level Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Heating dB(A) 51.0 53.0 57.0
Cooling dB(A) 54.0 50.0 51.8
Cooling dB(A) 59.0 62.0 70.0 Sound Pressure Level
Sound Power Level Heating dB(A) 60.0 54.0 55.1
Heating dB(A) 63.0 65.0 69.0
Cooling dB(A) 66.0 62.0 63.8
mm2 x No. Sound Power Level
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Heating dB(A) 72.0 66.0 67.1
(VCTF-SB)
Refrigerant Name R410A R410A R410A mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Precharged Amount in (VCTF-SB)
kg 5.8 5.8 5.8 Refrigerant Name R410A R410A R410A
Refrigerant Factory
t-CO2 eq. 12.1 12.1 12.1 Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
t-CO2 eq. 6.3 24.2 24.2
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380, 60 3, 380, 60 3, 380, 60
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Number of Maximum Connectable Indoor Units 1)
13 (20) 16 (25) 23 (35) Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) Number of Maximum Connectable Indoor Units 1) 32 (50) 26 (40) 29 (45)
* This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero * This product contains Fluorinated Greenhouse Gases. (R410A)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) Note : 1. Capacities and Inputs are based on the following conditions
2. Capacities are net capacities - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation some specifications may be changed without notification - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
072 073
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP
UNITS
ARWN220LAS4 / ARWN240LAS4 / ARWN280LAS4 ARWN300LAS4 / ARWN340LAS4 / ARWN400LAS4
MULTI V WATER IV
HP 22 24 28 HP 30 34 40
Combination Unit ARWN220LAS4 ARWN240LAS4 ARWN280LAS4 Combination Unit ARWN300LAS4 ARWN340LAS4 ARWN400LAS4
Model Name ARWN140LAS4 ARWN140LAS4 ARWN140LAS4 Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit Independent Unit
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
Cooling (Rated) kW 61.6 67.2 78.4 Cooling (Rated) kW 84.0 95.2 112.0
Capacity Capacity
Heating (Rated) kW 69.3 75.6 88.2 Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 11.70 12.93 15.68 Cooling (Rated) kW 16.29 19.04 22.40
Input Input
Heating (Rated) kW 12.37 13.51 16.34 Heating (Rated) kW 17.01 19.84 23.34
EER 5.26 5.20 5.00 EER 5.16 5.00 5.00
COP Rated Capacity 5.60 5.60 5.40 COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6 Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135 Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2 Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600 Oil Charge cc 5,800 5,800 6,000
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Pipe Connctions Pipe Connctions
Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2 Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2 Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Cooling dB(A) 58.3 58.6 59.0 Cooling dB(A) 55.5 59.0 55.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 58.0 58.5 58.0 Heating dB(A) 60.8 61.0 61.0
Cooling dB(A) 70.3 70.6 72.0 Cooling dB(A) 67.5 72.0 68.0
Sound Power Level Sound Power Level
Heating dB(A) 70.0 70.5 71.0 Heating dB(A) 72.8 74.0 74.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 11.6 11.6 11.6 kg 8.8 8.8 6.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 24.2 24.2 24.2 t-CO2 eq. 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 35 (44) 39 (48) 45 (56) Number of Maximum Connectable Indoor Units 1) 49 (60) 55 (64) 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
074 075
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP
UNITS
ARWN420LAS4 / ARWN440LAS4 / ARWN480LAS4 ARWN500LAS4 / ARWN540LAS4 / ARWN600LAS4
MULTI V WATER IV
HP 42 44 48 HP 50 54 60
Combination Unit ARWN420LAS4 ARWN440LAS4 ARWN480LAS4 Combination Unit ARWN500LAS4 ARWN540LAS4 ARWN600LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN140LAS4 ARWN140LAS4 ARWN140LAS4 Independent Unit ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
Cooling (Rated) kW 117.6 123.2 134.4 Cooling (Rated) kW 140.0 151.2 168.0
Capacity Capacity
Heating (Rated) kW 132.3 138.6 151.2 Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 22.9 24.13 26.88 Cooling (Rated) kW 27.49 30.24 33.60
Input Input
Heating (Rated) kW 24.04 25.18 28.01 Heating (Rated) kW 28.68 31.51 35.01
EER 5.14 5.11 5.00 EER 5.09 5.00 5.00
COP Rated Capacity 5.50 5.50 5.40 COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6 Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135 Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600 Oil Charge cc 8,800 8,800 9,000
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Pipe Connctions Pipe Connctions
Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch) Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch) Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Shipping Weight kg x No. (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Cooling dB(A) 59.7 59.9 60.0 Cooling dB(A) 57.8 60.0 56.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 62.1 62.3 62.0 Heating dB(A) 63.4 62.0 62.0
Cooling dB(A) 71.7 71.9 74.0 Cooling dB(A) 69.8 74.0 70.0
Sound Power Level Sound Power Level
Heating dB(A) 74.1 74.3 76.0 Heating dB(A) 75.4 76.0 76.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 14.6 14.6 14.6 kg 11.8 11.8 9.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 30.5 30.5 30.5 t-CO2 eq. 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
076 077
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP
UNITS
ARWN620LAS4 / ARWN640LAS4 / ARWN680LAS4 ARWN700LAS4 / ARWN740LAS4 / ARWN800LAS4
MULTI V WATER IV
HP 62 64 68 HP 70 74 80
Combination Unit ARWN620LAS4 ARWN640LAS4 ARWN680LAS4 Combination Unit ARWN700LAS4 ARWN740LAS4 ARWN800LAS4
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit Independent Unit
ARWN140LAS4 ARWN140LAS4 ARWN140LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
Cooling (Rated) kW 173.6 179.2 190.4 Cooling (Rated) kW 196.0 207.2 224.0
Capacity Capacity
Heating (Rated) kW 195.3 201.6 214.2 Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 34.10 35.33 38.08 Cooling (Rated) kW 38.69 41.44 44.80
Input Input
Heating (Rated) kW 35.71 36.85 39.68 Heating (Rated) kW 40.35 43.18 46.68
EER 5.09 5.07 5.00 EER 5.07 5.00 5.00
COP Rated Capacity 5.47 5.47 5.40 COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6 Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135 Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600 Oil Charge cc 11,800 11,800 12,000
Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Pipe Connctions Pipe Connctions
Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8) Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Cooling dB(A) 60.7 60.9 61.0 Cooling dB(A) 59.3 61.0 57.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 64.2 64.3 63.0 Heating dB(A) 65.1 63.0 63.0
Cooling dB(A) 72.7 72.9 75.0 Cooling dB(A) 71.3 75.0 71.0
Sound Power Level Sound Power Level
Heating dB(A) 76.2 76.3 77.0 Heating dB(A) 77.1 77.0 77.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 17.6 17.6 17.6 kg 14.8 14.8 12.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 36.7 36.7 36.7 t-CO2 eq. 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
078 079
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY
UNITS
ARWB080LAS4 / ARWB100LAS4 / ARWB140LAS4 ARWB200LAS4 / ARWB160LAS4 / ARWB180LAS4
MULTI V WATER IV
HP 8 10 14 HP 20 16 18
Combination Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4 Combination Unit ARWB200LAS4 ARWB160LAS4 ARWB180LAS4
Model Name Model Name
Independent Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4 ARWB080LAS4 ARWB100LAS4
Independent Unit ARWB200LAS4
ARWB080LAS4 ARWB080LAS4
Cooling (Rated) kW 22.4 28.0 39.2
Capacity Cooling (Rated) kW 56.0 44.8 50.4
Heating (Rated) kW 25.2 31.5 44.1 Capacity
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 3.86 5.09 7.84
Input Cooling (Rated) kW 11.20 7.72 8.95
Heating (Rated) kW 4.20 5.34 8.17 Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.80 5.50 5.00
EER 5.00 5.80 5.63
COP Rated Capacity 6.00 5.90 5.40
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45 Maximum Pressure
Heat Exchanger Resistance kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 77 96 135
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1 Motor Output x
Number Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Type FVC68D(PVE) FVC68D(PVE) FVC68D(PVE)
Oil Charge cc 2,800 2,800 2,800
Oil Charge cc 3,000 5,600 5,600
Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Liquid Pipe mm (inch) Ø 12.7(1/2) Ø 12.7(1/2) Ø 12.7(1/2)
Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 25.4 (1)
Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 28.58(1-1/8) Ø 28.58(1-1/8) Ø 28.58(1-1/8)
High Pressure Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
High Pressure Gas Pipe mm (inch) Ø 19.05(3/4) Ø 19.05(3/4) Ø 19.05(3/4)
Inlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Outlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) Inlet A (inch) 40A(PT 1-1/2) (Internal Thread)
Pipes (Internal Thread) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Outlet A (inch) 40A(PT 1-1/2) (Internal Thread)
Pipes (Internal Thread) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Cooling dB(A) 47.0 50.0 58.0
Sound Pressure Level Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Heating dB(A) 51.0 53.0 57.0
Cooling dB(A) 54.0 50.0 52.0
Cooling dB(A) 59.0 62.0 70.0 Sound Pressure Level
Sound Power Level Heating dB(A) 60.0 54.0 55.0
Heating dB(A) 63.0 65.0 69.0
Cooling dB(A) 66.0 62.0 64.0
mm2 x No. Sound Power Level
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Heating dB(A) 72.0 66.0 67.0
(VCTF-SB)
Refrigerant Name R410A R410A R410A mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Precharged Amount in (VCTF-SB)
kg 5.8 5.8 5.8 Refrigerant Name R410A R410A R410A
Refrigerant Factory
t-CO2 eq. 12.1 12.1 12.1 Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
t-CO2 eq. 6.3 24.2 24.2
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380, 60 3, 380, 60 3, 380, 60
3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Number of Maximum Connectable Indoor Units 1)
13 (20) 16 (25) 23 (35) Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) Number of Maximum Connectable Indoor Units 1) 32(50) 26(40) 29(45)
* This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero * This product contains Fluorinated Greenhouse Gases. (R410A)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) Note : 1. Capacities and Inputs are based on the following conditions
2. Capacities are net capacities - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation some specifications may be changed without notification - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
080 081
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY
UNITS
ARWB220LAS4 / ARWB240LAS4 / ARWB280LAS4 ARWB300LAS4 / ARWB340LAS4 / ARWB400LAS4
MULTI V WATER IV
HP 22 24 28 HP 30 34 40
Combination Unit ARWB220LAS4 ARWB240LAS4 ARWB280LAS4 Combination Unit ARWB300LAS4 ARWB340LAS4 ARWB400LAS4
Model Name ARWB140LAS4 ARWB140LAS4 ARWB140LAS4 Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit Independent Unit
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4 ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
Cooling (Rated) kW 61.6 67.2 78.4 Cooling (Rated) kW 84.0 95.2 112.0
Capacity Capacity
Heating (Rated) kW 69.3 75.6 88.2 Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 11.70 12.93 15.68 Cooling (Rated) kW 16.29 19.04 22.40
Input Input
Heating (Rated) kW 12.37 13.51 16.34 Heating (Rated) kW 17.01 19.84 23.34
EER 5.26 5.20 5.00 EER 5.16 5.00 5.00
COP Rated Capacity 5.60 5.60 5.40 COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6 Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135 Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2 Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600 Oil Charge cc 5,800 5,800 6,000
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8)
High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2 Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2 Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Cooling dB(A) 58.0 59.0 59.0 Cooling dB(A) 55.0 59.0 55.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 58.0 58.0 58.0 Heating dB(A) 61.0 61.0 61.0
Cooling dB(A) 70.0 71.0 72.0 Cooling dB(A) 67.0 72.0 68.0
Sound Power Level Sound Power Level
Heating dB(A) 70.0 70.0 71.0 Heating dB(A) 73.0 74.0 74.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 11.6 11.6 11.6 kg 8.8 8.8 6.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 24.2 24.2 24.2 t-CO2 eq. 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 35 (44) 39 (48) 45 (56) Number of Maximum Connectable Indoor Units 1) 49 (60) 55 (64) 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130% .(2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
082 083
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY
UNITS
ARWB420LAS4 / ARWB440LAS4 / ARWB480LAS4 ARWB500LAS4 / ARWB540LAS4 / ARWB600LAS4
MULTI V WATER IV
HP 42 44 48 HP 50 54 60
Combination Unit ARWB420LAS4 ARWB440LAS4 ARWB480LAS4 Combination Unit ARWB500LAS4 ARWB540LAS4 ARWB600LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB140LAS4 ARWB140LAS4 ARWB140LAS4 Independent Unit ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4 ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
Cooling (Rated) kW 117.6 123.2 134.4 Cooling (Rated) kW 140.0 151.2 168.0
Capacity Capacity
Heating (Rated) kW 132.3 138.6 151.2 Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 22.9 24.13 26.88 Cooling (Rated) kW 27.49 30.24 33.60
Input Input
Heating (Rated) kW 24.04 25.18 28.01 Heating (Rated) kW 28.68 31.51 35.01
EER 5.14 5.11 5.00 EER 5.09 5.00 5.00
COP Rated Capacity 5.50 5.50 5.40 COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6 Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135 Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600 Oil Charge cc 8,800 8,800 9,000
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch) Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch) Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) Net Weight kg x No. (140 x 2) + (127 X 1) (140 x 2) + (127 X 1) 140 x 3
Shipping Weight kg x No. (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) Shipping Weight kg x No. (150 x 2) + (137 X 1) (150 x 2) + (137 X 1) 150 x 3
Cooling dB(A) 60.0 60.0 60.0 Cooling dB(A) 58.0 60.0 56.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 62.0 62.0 62.0 Heating dB(A) 63.0 62.0 62.0
Cooling dB(A) 72.0 72.0 74.0 Cooling dB(A) 70.0 74.0 70.0
Sound Power Level Sound Power Level
Heating dB(A) 74.0 74.0 76.0 Heating dB(A) 75.0 76.0 76.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 14.6 14.6 14.6 kg 11.8 11.8 9.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 30.5 30.5 30.5 t-CO2 eq. 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
084 085
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
OUTDOOR
MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY
UNITS
ARWB620LAS4 / ARWB640LAS4 / ARWB680LAS4 ARWB700LAS4 / ARWB740LAS4 / ARWB800LAS4
MULTI V WATER IV
HP 62 64 68 HP 70 74 80
Combination Unit ARWB620LAS4 ARWB640LAS4 ARWB680LAS4 Combination Unit ARWB700LAS4 ARWB740LAS4 ARWB800LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit Independent Unit
ARWB140LAS4 ARWB140LAS4 ARWB140LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4 ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
Cooling (Rated) kW 173.6 179.2 190.4 Cooling (Rated) kW 196.0 207.2 224.0
Capacity Capacity
Heating (Rated) kW 195.3 201.6 214.2 Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 34.10 35.33 38.08 Cooling (Rated) kW 38.69 41.44 44.80
Input Input
Heating (Rated) kW 35.71 36.85 39.68 Heating (Rated) kW 40.35 43.18 46.68
EER 5.09 5.07 5.00 EER 5.07 5.00 5.00
COP Rated Capacity 5.47 5.47 5.40 COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6 Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135 Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600 Oil Charge cc 11,800 11,800 12,000
Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8) Pipe Connctions #1 Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
High Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4) High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Cooling dB(A) 61.0 61.0 61.0 Cooling dB(A) 59.0 61.0 57.0
Sound Pressure Level Sound Pressure Level
Heating dB(A) 64.0 64.0 63.0 Heating dB(A) 65.0 63.0 63.0
Cooling dB(A) 73.0 73.0 75.0 Cooling dB(A) 71.0 75.0 71.0
Sound Power Level Sound Power Level
Heating dB(A) 76.0 76.0 77.0 Heating dB(A) 77.0 77.0 77.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 17.6 17.6 17.6 kg 14.8 14.8 12.0
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 36.7 36.7 36.7 t-CO2 eq. 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50 3, 380 ~ 415, 50
Power Supply Ø, V, Hz Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of Maximum Connectable Indoor Units 1) 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64
1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria) 1) The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. (2.2kW criteria)
* This product contains Fluorinated Greenhouse Gases. (R410A) * This product contains Fluorinated Greenhouse Gases. (R410A)
Note : 1. Capacities and Inputs are based on the following conditions Note : 1. Capacities and Inputs are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F), Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
2. Capacities are net capacities 2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification 3. Due to our policy of innovation some specifications may be changed without notification
4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 4. Add an anti freeze to circulation water when outside unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
086 087
OUTDOOR UNITS _ MULTI V WATER S OUTDOOR UNITS _ MULTI V WATER S _ KEY FEATURES
OUTDOOR
ENERGY SAVING SPACE SAVING &
UNITS
World’s First Class Cooling
CONVENIENT INSTALLATION
and Heating Efficiency Compact Size
MULTI V WATER S
MULTI V WATER S EER and COP is superior Outdoor unit can be placed inside a closet, no need for roof or
- Water Cooled VRF Heat Pump
outside space. It can be applicable for small space application such
- 11.2 ~ 15.5kW (Cooling capacity based) EER is Max. 81% higher COP is Max. 76% higher as shops in city centers and malls.
- 1Φ, 220 ~ 240V, 50 ~ 60Hz than W-Company
- Outdoor unit installed indoor
Foot print area
Geothermal Application 77% 76% 6HP
4.8 5.1 15.5kW
2.7 2.9
6HP
6HP (15.5kW) 6HP (15.5kW) 15.5kW
1,120mm
W-Company
MULTI V WATER S
76%
Reduction
520mm
Variable Water Flow Control (Option)
Cooling Tower Application Supporting your buildings to become greener
630mm 330mm
Conventional MULTI V WATER S
River / Sea
ON
Features & Benefits Key Applications Actual longest piping length 70 (90)m
088 089
OUTDOOR UNITS _ MULTI V WATER S _ TECHNICAL DATA OUTDOOR UNITS _ MULTI V WATER S _ SPECIFICATION
OUTDOOR
MULTI V WATER S
UNITS
ARW N 60 G a 0 Cooling Heating
45°C 45°C
Generation
MULTI V WATER S
Electrical Ratings 30°C 30°C
G : 1Ø, 220 ~ 240V, 50Hz / 1Ø, 220V, 60Hz
25°C 25°C
Total Cooling Capacity in Horse Power
EX) ‘60’ → 6HP Class 20°C 20°C
Indicates that this is 10°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 30°C HP 6
Outdoor Units
Water System Outside Unit using the R410A Indoor Temperature (°C WB) Indoor Temperature (°C WB) Cooling (Rated) kW 15.5
Capacity
Note : 1. These figures assume the following operating conditions: Heating (Rated) kW 18.0
2 _ R410A(50Hz)
379(14-29/32)
Anti Corrosion Black Fin - Type Cupro brazed Stainless Steel Plate
330(13)
Oil Sensor - Maximum Pressure
Dual Sensing - kgf/cm2 45
Heat Exchanger Resistance
Low Noise Operation - Head Loss kPa 28.4
Hgih Static Mode of Outdoor Unit Fan - Rated Water Flow LPM 60
Partial Defrosting -
523(20-15/32) Type BLDC Inverter Twin Rotary
Auto Dust Cleaning of Outdoor Unit 520(20-19/32)
- Combination x No. (Inverter) x 1
Useful Function (Fan reverse rotation)
Indoor Cooling Comfort Mode Based Motor Output x
- Compressor W x No. 4,000 x 1
Outdoor Temperature Number
Smart Load Control (SLC) Oil Type FVC68D (PVE)
(Changing indoor discharge air - Oil Charge cc 2,600
temperature according to load) 60(2-3/8)
1080(42-17/32)
Outdoor Unit Control Refer to Humidity - Liquid Pipe mm (inch) Ø 9.52 (3/8)
Pipe Connctions
Defrost / Deicing - Gas Pipe mm (inch) Ø 19.05 (3/4)
113(4-7/16) 227(8-15/16)
High Pressure Switch ○ Water Connecting Inlet A (inch) 32A (PT 1-1/4)
554(21-13/16)
338(13-5/16)
Self Diagnosis ○
242(9-17/32)
Dimensions (W x H x D) - Shipping mm x No. (688 x 1,170 x 414) x 1
Soft Start ○
2. Installation Space
88(3-15/32)
Cycle Monitoring LGMV PRCTIL0 • Install a pressure gauge and temperature 193 (7-19/32) gauge at the inlet and outlet of the water pipe.
Device Mobile LGMV - • Flexible joints must be installed 100 (3-15/16)not to cause any20leakage
523 (20-19/32) (25/32) from the vibrationH-Beam Support
of pipes.
• Install a service port to clean the heat exchanger at the each end of the water Front inlet
View and outlet. * This product contains Fluorinated Greenhouse Gases. (R410A)
※ ○ : Applied, - : Not Applied Top View
• For the components of the water pipe system, always use components above the designed water pressure. Note : 1. Capacities are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Water 30°C (86°F)
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Water 20°C (68°F)
- Piping Length : Interconnected Pipe Length = 7.5m
Position of Sound Pressure Level
dB(A) - Difference Limit of Elevation (Outside ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national codes.
3. Due to our policy of innovation some specifications may be changed without notification.
Outdoor Units
Installation of
Outside Units
Installation of
Water pipe
Inlet Strainer
Installation of
Outside Units
Drain line
as 1.5m (3.3ft)
ar
090 CAUTION 091
Do not directly connect the drain outlet to the water pipe outlet.
(It can cause problems to the product.)
2 R410A(50Hz)
INDOOR UNITS
INDOOR
UNITS
WALL MOUNTED UNIT / CEILING MOUNTED CASSETTE /
CEILING CONCEALED DUCT / FRESH AIR INTAKE UNIT /
CEILING & FLOOR CONVERTIBLE UNIT /
CEILING SUSPENDED UNIT /
CONSOLE & FLOOR STANDING UNIT /
/ COMPATIBILITY / FEATURE FUNCTIONS
092 093
INDOOR UNITS _ WALL MOUNTED UNIT INDOOR UNITS _ WALL MOUNTED UNIT _ KEY FEATURES
SMART
WALL MOUNTED Wi-Fi Control
Control your air conditioners via using the smart internet devices as Android or iOS based smartphones.
UNIT
This advanced technology provides you the best convenience.
INDOOR UNITS
LG SmartThinQ
Search “LG SmartThinQ” on Google market or Appstore then download the app.
LG Smart ThinQ
Integrated Home Appliances Control Access your air conditioner anytime and from anywhere
Multiple Devices
094 095
INDOOR UNITS _ WALL MOUNTED UNIT _ KEY FEATURES
INDOOR UNITS
millionthe
particles by infusing ions
airto sterilize
passing not only
through the
the air air passing
conditioner withthrough the ions.
over 3 millions How It Works
* Specifications may vary for each model. keep running on that time until cancelled by the user or
air conditioner, but also surrounding surfaces for a safer, after setting period
and cleaner environment. 6-Step Vane,
6-Step Vane,Control
Controlup
uptoto70°
70° 5-Step Louver, Control
* This function upremote
is for wired to 55°
controller only.
The
Thevertical vane,
vertical which
vane, moves
which up andup
moves down,
andhas 6 different
down, has 6settings including
different full-auto swing.
settings * Wired
The louver, which remote
sways leftcontroller
and right,ishas
need to be separately
5 different settingspurchased.
including full auto-swing.
O - * Specifications may vary for each model.
* Depending on the experimental conditions. H H
including full-auto swing.
H+ H H
H H Schedule 1 Schedule 2
O-
Sterilization and Deodorization (Utilizes Over 3 Million Ions) Setting temperature : 19℃ Setting temperature : 21℃
* Test Conditions :
100
Space : 52m3 Chamber air conditioner, the auto cleaning function
evenremoves a perioddeodorizing
after advanced function.
of 10 years. by various germs and bacteria, the cooling performance thermistors in the remote controller as well as from the
all substances that might be harmful to human body. and longevity ofthe air conditioner remains unchanged
Pain 99.9
80 2 Temperature
H H & Humidity : Normal
% even after 10 years of usage.
4 Way Swing indoor unit. There may be a significant difference between
60 Point
Sanitization
H
Bacteria H
H H : Staphylococus Aureus
Certificate
Benefit ceiling and floor air temperature. Two thermistors can
4 Way Swing disperses cool air quickly and effectively in multiple directions to each corner of a room.
Removes Harmful Particles
2.1 odor
40 strength decrease in with
Air conditioners 60 vanes
minutes
that only move up and down are Intertek,
Removes
By eliminating the humidity and bacteria left in the
Verification
Harmful
The indoor
Certifying Antibacterial
Particles
environment remains odorless with the By preventing the polluting of the heat exchanger
Left & Right
optimise indoor air temperature for a more comfortable
30 min.
20 unable to suitably cool all areas of aairroom.
An odor0of strength 2 or less indicates that thereallissubstances odor but no besense
that might
Function
conditioner, the auto cleaning function removes
Auto Cleaning ofdeodorizing
advancedprovides
Auto Cleaning provides clean air by preventing bacteria, mold and odors that
cleanfunction.
Plasmaster Ionizer+
air by eliminating
can otherwise accumulate in an indoor unit.
harmful to human body.
bacteria,/mold
Ionizer
byand
various
odorsgerms andotherwise
that can bacteria, the cooling performance
accumulate in an indoor unit.
and longevity ofthe air conditioner remains unchanged
110° environment.
Heating /
even after 10 years of usage.
of displeasure (degree15of odor permissible).
30 45 60
Cooling
Benefit Time (min) * Angle can be different from each model and working mode.
d and bacteria growing on
2.1 odor strength decrease
he heat exchanger is wet.
Odor
in 60 Harmful
Removes minutes Particles Easy and Simple Control
1 2 Cleaning provides
Auto 3 clean air by eliminating
4 bacteria, mold and odors that can otherwise accumulate in an indoor unit. Indoor Unit
Strength
An odor of measured as 2 European odor units (ouE/m³) or less Airflow direction can be changed Thermistor
indicates that the level of odor falls within permissible limits. by LG ThinQ Wi-Fi app.
Normal
reus
Odor Strength
Offensive
odor
1 2 3 4
How It Works Benefit
substance
Offensive Bacteria Elimination Odor Elimination Mold Elimination
sensitivity odor
Mountain Indoor life Bathroom Food waste
4 Way
Cleans Filter with Regular Swing
Airflow
substance smell smell smell smell
sensitivity Mountain Indoor life Bathroom Food waste 4 Way
The comprehensive auto cleaning Swing
function disperses
prevents cool air quickly
the formation and effectively
of bacteria and mold in
onmultiple
the heatdirections
exchanger,toproviding
each corner of apleasant
a more room. and comfortable environment.
Up / Down Swing
and down are Odor strength smell smell smell smell
Light Moderate Strong Very Strong
level Remote Controller
Odor strength level Light Moderate Strong Very Strong
Jet Cool Thermistor
The interior of the air conditioner is maintained clean INSTALLATION air conditioner, the auto cleaning function removes advanced deodorizing function.
all substances that might be harmful to human body.
One
by Click
various “Jet
germs and Mode”
bacteria, the cooling performance
and longevity ofthe air conditioner remains unchanged
Reduces
even the
after 10 temperature
years of usage. of outflowing air to 18°C for 30 minutes with
by drying off the heat exchanger, then sterilizing the
Installation Support Clip just one click.
interior once more. Benefit
A support clip creates adequate space between the wall and the unit for
Removes Harmful Particles
easier installation.
Pain Point
Auto Cleaning provides clean air by eliminating bacteria, mold and odors that can otherwise accumulate in an indoor unit.
The main cause of odor within air conditioners is mold and bacteria Cooling / Heating Dehumidification
growing on the heat exchanger. These germs can spread when the heat Fan only operating Setting temp.
25°
exchanger is wet.
ng on Standard Operation
wet.
096 097
INDOOR UNITS _ WALL MOUNTED UNIT _ SPECIFICATION
ARTCOOL MIRROR
INDOOR UNITS
ARNU05GSJR4 / ARNU07GSJR4 / ARNU09GSJR4 ARNU18GSKR4 / ARNU24GSKR4
ARNU12GSJR4 / ARNU15GSJR4
Accessories Accessories
Chassis ARNU05GSJR4 ARNU07GSJR4 ARNU09GSJR4 ARNU12GSJR4 ARNU15GSJR4 Chassis ARNU18GSKR4 ARNU24GSKR4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator ○ Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi ○ Wi-Fi ○
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
098 099
INDOOR UNITS _ WALL MOUNTED UNIT _ SPECIFICATION
INDOOR UNITS
ARNU07GSF14 / ARNU09GSF14 / ARNU12GSF14 ARNU05GSJ*4 / ARNU07GSJ*4 / ARNU09GSJ*4 / ARNU12GSJ*4 / ARNU15GSJ*4
Accessories Accessories
Chassis ARNU07GSF14 ARNU09GSF14 ARNU12GSF14 Chassis ARNU05GSJ*4 ARNU07GSJ*4 ARNU09GSJ*4 ARNU12GSJ*4 ARNU15GSJ*4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD2001) Wi-Fi ○
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
1) External installation only
100 101
INDOOR UNITS _ WALL MOUNTED UNIT _ SPECIFICATION
STANDARD
INDOOR UNITS
ARNU18GSK*4 / ARNU24GSK*4 ARNU30GSVA4 / ARNU36GSVA4
Accessories Accessories
Chassis ARNU18GSK*4 ARNU24GSK*4 Chassis ARNU30GSVA4 ARNU36GSVA4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator ○ Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi ○ Wi-Fi PWFMDD2001)
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
1) External installation only
102 103
INDOOR UNITS _ CEILING MOUNTED CASSETTE INDOOR UNITS _ CEILING MOUNTED CASSETTE _ KEY FEATURES
CASSETTE
devices as Android or iOS based smartphones. by drying off the heat exchanger, then sterilizing the
INDOOR UNITS
This advanced technology provides you the best convenience. interior once more.
LG SmartThinQ
Search “LG SmartThinQ” on Google market or Appstore
LG Smart ThinQ then download the app.
Human detection Humidity Sensor
sensor (PTVSMA0)
Access your air conditioner anytime and from anywhere
Detection range
Wi-Fi Connectivity
Let’s every member of your family choose their own preferred air
conditioning temperature and fan speed, then save the settings in their app
to run later. You can save the setting for each air conditioner as well.
Multiple Devices
Height 3.2 (15 x 8m) Height 3.5 (16 x 10m) A sensor is installed
90˚rotation
12 x 6m 6 x 12m detecting
On/Off mode
The indoor unit automatically stops when detecting absence. It runs as
the s us mode when sensing human body.
Sensing human body Undetected Sensing human body Undetected
104 105
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ KEY FEATURES
INDOOR UNITS
interior once more Indirect air flow Direct air flow the ceiling tile. so it can provide ideal solution for installation in limited space.
* Specifications may vary for each model.
300 or more
Ceiling
Ceiling Board
Group Control Hanger
adjust
Hanger adjust
Ceiling Board
In case of group control, user can control much more
300 or less
function than conventional High Ceiling Mode 500 or
or more
Conventional New Drain leakage check Hanger adjust 500 or
High ceiling mode provides powerful cooling and heating up
1,000
more more
4,000 or less
Above 2,500
to 4.2m in height, from ceiling to floor.
Standard Operation
High Ceiling Mode
Standard
Operation 4.2 Unit : mm
In case of group control 4
Sub function
isn’t operating 4 3 2 1 0 1 2 3 4
106 107
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ SPECIFICATION
INDOOR UNITS
ARNU05GTRD4 / ARNU07GTRD4 / ARNU09GTRD4 / ARNU12GTRD4 ARNU05GTRC4 / ARNU07GTRC4 / ARNU09GTRC4 / ARNU12GTRC4
ARNU15GTQD4 / ARNU18GTQD4 / ARNU21GTQD4 ARNU15GTQC4 / ARNU18GTQC4 / ARNU21GTQC4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU05GTRD4 ARNU07GTRD4 ARNU09GTRD4 ARNU12GTRD4 ARNU15GTQD4 ARNU18GTQD4 ARNU21GTQD4 Chassis ARNU05GTRC4 ARNU07GTRC4 ARNU09GTRC4 ARNU12GTRC4 ARNU15GTQC4 ARNU18GTQC4 ARNU21GTQC4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCQ Cassette Cover PTDCQ
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 (~4.5kW) EEV Kit PRGK024A0 (~4.5kW)
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB501 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi -
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
108 109
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ SPECIFICATION
INDOOR UNITS
ARNU24GTPC4 / ARNU28GTPC4 / ARNU30GTPC4 / ARNU36GTNC4 ARNU42GTM / C4ARNU48GTMC4 / ARNU54GTMC4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU24GTPC4 ARNU28GTPC4 ARNU30GTPC4 ARNU36GTNC4 Chassis ARNU42GTMC4 ARNU48GTMC4 ARNU54GTMC4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCM Cassette Cover PTDCM
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB502 (Modbus) PDRYCB502 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
110 111
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ SPECIFICATION
INDOOR UNITS
ARNU07GTNA4 / ARNU09GTNA4 / ARNU12GTNA4 ARNU24GTMA4 / ARNU28GTMA4
ARNU15GTNA4 / ARNU18GTNA4 ARNU36GTMA4 / ARNU42GTMA4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU07GTNA4 ARNU09GTNA4 ARNU12GTNA4 ARNU15GTNA4 ARNU18GTNA4 Chassis ARNU24GTMA4 ARNU28GTMA4 ARNU36GTMA4 ARNU42GTMA4
Accessories
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCM Cassette Cover PTDCM
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
112 113
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ SPECIFICATION
INDOOR UNITS
ARNU09GTSC4 / ARNU12GTSC4 ARNU07GTUC4 / ARNU09GTUC4 / ARNU12GTUC4
ARNU18GTSC4 / ARNU24GTSC4 ARNU18GTTC4 / ARNU24GTTC4
Accessories Accessories
Chassis ARNU09GTSC4 ARNU12GTSC4 ARNU18GTSC4 ARNU24GTSC4 Chassis ARNU07GTUC4 ARNU09GTUC4 ARNU12GTUC4 ARNU18GTTC4 ARNU24GTTC4
Drain Pump ○ Drain Pump ○ ○
Cassette Cover - Cassette Cover - -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0 PRLDNVS0
EEV Kit PRGK024A0 (~5.6kW) EEV Kit PRGK024A0 -
Independent Power Module PRIP0 Independent Power Module PRIP0 PRIP0
Robot Cleaner - Robot Cleaner - -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○ ○
Ion Generator - Ion Generator - -
CO2 Sensor - CO2 Sensor - -
Ventilation Kit - Ventilation Kit - -
IR Receiver - IR Receiver - -
Zone Controller - Zone Controller - -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus) PDRYCB502 (Modbus)
External Input (1 point) ○ External Input (1 point) ○ ○
Wi-Fi PWFMDD200 Wi-Fi - -
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
114 115
INDOOR UNITS _ CEILING MOUNTED CASSETTE _ SPECIFICATION
1 WAY CASSETTE
INDOOR UNITS
ARNU07GTUD4 / ARNU09GTUD4 / ARNU12GTUD4 ARNU18GTTD4 / ARNU24GTTD4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU07GTUD4 ARNU09GTUD4 ARNU12GTUD4 Chassis ARNU18GTTD4 ARNU24GTTD4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB501 (Modbus) PDRYCB503 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
116 117
INDOOR UNITS _ CEILING CONCEALED DUCT INDOOR UNITS _ CEILING CONCEALED DUCT_ KEY FEATURES
CONCEALED DUCT
devices as Android or iOS based smartphones. remote controller secured by the ESP control function.
INDOOR UNITS
This advanced technology provides you the best convenience. The BLDC motor can control fan speed and air volume
regardless of the external static pressure. No additional
LG SmartThinQ accessories are necessary to control air flow.
Search “LG SmartThinQ” on Google market or Appstore
E.S.P. E.S.P.
LG Smart ThinQ then download the app. Control Control
Wi-Fi
Conventional New
Smart ThinQ
1 step
Static Pressure
Low Setting
Energy Monitoring
(Accumulated Electric Energy Check)
Accumulated electric energy of the indoor unit can be
identified with wired remote control, as well as with
the central controller. This function is an advantage for
Features & Benefits Key Applications energy management.
• E.S.P. Control Function can Make Air Volume Controlled Easily with Remote Controller. • Hotel / Conference Center Install Scene Apply for multistory building
• Retail / Shopping Center 100kWh
• School
Watt PDI
• Office Meter
118 119
INDOOR UNITS _ CEILING CONCEALED DUCT_ KEY FEATURES
COMFORT
Operation for Multiple Rooms Minimized Height
Using a spiral duct (embedded or flexible type) and New mid-static ducts provide ideal solution for installation
stream chamber, it is possible to operate cooling / heating in limited space.
INDOOR UNITS
for several rooms simultaneously.
270mm
8 / 10kW 12.5kW
380
mm
270 270
mm mm
Premium Wired
Remote Controller
Remote Controller Thermistor
Remain time until indoor filter cleaning 1729hr.
Cost Savings
Key Tag
* In case of needing more functions beside on / off control, a dry contact is required to be installed.
120 121
INDOOR UNITS _ CEILING CONCEALED DUCT _ SPECIFICATION
MID STATIC
INDOOR UNITS
ARNU07GM1A4 / ARNU09GM1A4 / ARNU12GM1A4 ARNU28GM2A4 / ARNU36GM2A4 / ARNU42GM2A4 / ARNU48GM3A4 / ARNU54GM3A4
ARNU15GM1A4 / ARNU18GM1A4 / ARNU24GM1A4
Accessories Accessories
Chassis ARNU07GM1A4 ARNU09GM1A4 ARNU12GM1A4 ARNU15GM1A4 ARNU18GM1A4 ARNU24GM1A4 Chassis ARNU28GM2A4 ARNU36GM2A4 ARNU42GM2A4 ARNU48GM3A4 ARNU54GM3A4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 (~5.6kW) EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
122 123
INDOOR UNITS _ CEILING CONCEALED DUCT _ SPECIFICATION
INDOOR UNITS
ARNU76GB8A4 / ARNU96GB8A4 ARNU05GL1G4 / ARNU07GL1G4 / ARNU09GL1G4
Accessories Accessories
Chassis ARNU76GB8A4 ARNU96GB8A4 Chassis ARNU05GL1G4 ARNU07GL1G4 ARNU09GL1G4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit ○ EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
124 125
INDOOR UNITS _ CEILING CONCEALED DUCT _ SPECIFICATION
LOW STATIC
INDOOR UNITS
ARNU12GL2G4 / ARNU15GL2G4 / ARNU18GL2G4 ARNU21GL3G4 / ARNU24GL3G4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU12GL2G4 ARNU15GL2G4 ARNU18GL2G4 Chassis ARNU21GL3G4 ARNU24GL3G4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
126 127
INDOOR UNITS _ CEILING CONCEALED DUCT _ SPECIFICATION
HIGH SENSIBLE
INDOOR UNITS
ARNU07GBGA4 / ARNU09GBGA4 / ARNU12GBGA4 / ARNU15GBGA4 / ARNU18GBRA4 ARNU24GBRA4 / ARNU28GBRA4 / ARNU36GB8A4 / ARNU42GB8A4 / ARNU48GB8A4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU07GBGA4 ARNU09GBGA4 ARNU12GBGA4 ARNU15GBGA4 ARNU18GBRA4 Chassis ARNU24GBRA4 ARNU28GBRA4 ARNU36GB8A4 ARNU42GB8A4 ARNU48GB8A4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
128 129
INDOOR UNITS _ FRESH AIR INTAKE UNIT _ KEY FEATURES INDOOR UNITS _ FRESH AIR INTAKE UNIT _ SPECIFICATION
INDOOR UNITS
positive air pressure consistently, which can block cold, hot or contaminated air from outside.
CAUTION
MULTI V 5 Outdoor Unit MULTI V 5 Outdoor Unit
1. Operation range (Cooling : 5°C ~ 43°C, Heating : -5°C ~ 43°C) 2. Installation of exhaust fan is recommended for a sealed room. 3. Indoor Unit Connection
No Connection Condition Combination
Fresh air intake units only 1) The total capcity of fresh air intak unit should be 50 ~ 100% of outdoor unit.
1
are connected with outdoor units 2) The max quantity of fresh air intake is 4 units.
Mixture connection with 1) The total capacity of indoor units (Standard Indoor Unit + Fresh Air Intake Unit) should be 50 ~ 100% of outdoor unit.
Installation Scene 2
general indoor unit and fresh intake units 2) The total capacity of fresh air intake unit should be less than 30% of the total capacity of indoor units.
Min. 2m Accessories
Chassis ARNU48GBRZ4 ARNU76GB8Z4 ARNU96GB8Z4
Drain Pump ○
Cassette Cover -
1/30 Slope Refrigerant Leakage Detector PRLDNVS0
Outlet Air EEV Kit -
Independent Power Module PRIP0
Robot Cleaner -
Pre Filter (washable / anti-fungus) ○
Ion Generator -
Exhaust Air CO2 Sensor -
Ventilation Kit -
Inlet Hood Intake Air Duct Fresh Air Intake Unit IR Receiver PWLRVN000
Zone Controller -
Exhaust Fan Door
PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory)
PDRYCB400 (2 points input)
PDRYCB500 (Modbus)
External Input (1 point) ○
Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied
Option : Refer to model name in table
130 131
INDOOR UNITS _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT INDOOR UNITS _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT _ KEY FEATURES
SMART COMFORT
CEILING & FLOOR CONVERTIBLE UNIT Wi-Fi Control
Control your air conditioners via using the smart internet
Differentiated Design
With its stunning V-shaped design and black vane, LG’s new
INDOOR UNITS
This advanced technology provides you the best convenience. appropriate for any space. The tasteful aesthetics of the air
conditioner helped earn it the iF Design Award.
LG SmartThinQ
Search “LG SmartThinQ” on Google market or Appstore
LG Smart ThinQ then download the app.
COMFORT
Flexible Installation
The ceiling and floor models can be installed either on the One Touch & 2 Piece Filter
ceiling or on the floor. Easy in / out filter structure as well as a simplified two-piece
filter, which slides out for easy cleaning and maintenance.
132 133
2,000e+001
1,800e+001
1,600e+001
1,400e+001
1,200e+001
1,000e+001
8,000e+000
6,000e+000
4,000e+000
2,000e+000
0,000e+000
[m s^-1]
INDOOR UNITS _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT _ SPECIFICATION
INDOOR UNITS
ARNU09GVEA4 / ARNU12GVEA4 ARNU18GV1A4 / ARNU24GV1A4
ARNU36GV2A4 / ARNU48GV2A4
Accessories Accessories
Chassis ARNU09GVEA4 ARNU12GVEA4 Chassis ARNU18GV1A4 ARNU24GV1A4 ARNU36GV2A4 ARNU48GV2A4
Drain Pump - Drain Pump -
Refrigerant Leakage Detector - Cassette Cover -
EEV Kit PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
Independent Power Module PRGK024A0 EEV Kit -
Plasma Kit PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 1) Wi-Fi PWFMDD200
134 135
INDOOR UNITS _ CONSOLE & FLOOR STANDING UNIT INDOOR UNITS _ CONSOLE & FLOOR STANDING UNIT _ KEY FEATURES
SMART COMFORT
CONSOLE & Wi-Fi Control
Control your air conditioners via using the smart internet
Block Cold Draft
The floor standing unit can block cold drafts from windows
INDOOR UNITS
This advanced technology provides you the best convenience. libraries and offices.
Without Floor Standing
LG SmartThinQ
Search “LG SmartThinQ” on Google market or Appstore
LG Smart ThinQ then download the app.
COMFORT
Installation Support Clip
During the cooling operation, the vane adjusts upwards to direct the
air flow towards the ceiling. When heating, the vane directs the warm
air downwards to balance the room temperature especially for floor.
Cooling Heating (Normal) Heating (Option) 3 Way Flexible Installation
It is possible to install and connect the outdoor unit in 3
different ways (Side, Back, Floor).
Floor
Step5
136 137
INDOOR UNITS _ CONSOLE & FLOOR STANDING UNIT _ SPECIFICATION
CONSOLE
INDOOR UNITS
ARNU07GQAA4 / ARNU09GQAA4 ARNU12GQAA4 / ARNU15GQAA4
Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification
Accessories Accessories
Chassis ARNU07GQAA4 ARNU15GQAA4 Chassis ARNU12GQAA4 ARNU15GQAA4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) ○ Pre Filter (washable / anti-fungus) ○
Ion Generator ○ Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
138 139
INDOOR UNITS _ CONSOLE & FLOOR STANDING UNIT _ SPECIFICATION
INDOOR UNITS
* A : Floor Standing with case * U : Floor Standing without case
Accessories Accessories
Chassis ARNU07GCEA4 ARNU09GCEA4 ARNU12GCEA4 ARNU15GCEA4 ARNU18GCFA4 ARNU24GCFA4 Chassis ARNU07GCEU4 ARNU09GCEU4 ARNU12GCEU4 ARNU15GCEU4 ARNU18GCFU4 ARNU24GCFU4
Drain Pump - - Drain Pump - -
Cassette Cover - - Cassette Cover - -
Refrigerant Leakage Detector PRLDNVS0 PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0 PRLDNVS0
EEV Kit PRGK024A0 - EEV Kit PRGK024A0 -
Independent Power Module PRIP0 PRIP0 Independent Power Module PRIP0 PRIP0
Robot Cleaner - - Robot Cleaner - -
Pre Filter (washable / anti-fungus) ○ ○ Pre Filter (washable / anti-fungus) ○ ○
Ion Generator - - Ion Generator - -
CO2 Sensor - - CO2 Sensor - -
Ventilation Kit - - Ventilation Kit - -
IR Receiver PWLRVN000 PWLRVN000 IR Receiver PWLRVN000 PWLRVN000
Zone Controller - - Zone Controller - -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
PDRYCB300 (8 points for PDRYCB300 (8 points for
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
Dry Contact (with additional accessory) thermostat compatible) Dry Contact (with additional accessory) thermostat compatible)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB400 (2 points input) PDRYCB400 (2 points input)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) ○ ○ External Input (1 point) ○ ○
Wi-Fi PWFMDD200 PWFMDD200 Wi-Fi PWFMDD200 PWFMDD200
140 141
INDOOR UNITS _ COMPATIBILITY
COMPATIBILITY
INDOOR UNITS
Required Controller Wired Remote Controller
New Centralized Controller
Premium Simple
Function Name Standard III Standard II
No. Function Description Wired Remarks (PREMTA000 Simple for Hotel Simple
(4th generation Centralized (PREMTB100) (PREMTBB01)
Remote AC EZ AC EZ Touch AC Smart 5 ACP 5 AC Manager 5
indoor) Controller PREMTA000A (PQRCHCA0Q / (PQRCVCL0Q /
Controller (PREMTBB10) (PREMTB001) (PQCSZ250S0) (PACEZA000) (PACS5A000) (PACP5A000) (PACM5A000)
PREMTA000B) QW) QW)
Monitoring accumulated power consumption * Neccesary to install the PDI (Power Distribution Indicator) and central controller
○ ○ ○ ○ ○ - - - ○ ○ ○ ○
COMPATIBILITY
Energy Monitoring by Wired Remote Controller * Combined with MULTI V WATER S outdoor unit, this function is not available.
1 (Accumulated Electric
Energy Check) Monitoring accumulated power consumption * Neccesary to install the PDI (Power Distribution Indicator)
by Central Control Device / PDI
- ○ * To make a report, central controller must be installed - - - - - - ○ ○ ○ ○
* Centralized control is able to when you combine only 4th generation indoor
1) Synchronization according to occupied/unoccupied
units (Use together with 2nd generation and 4th generation indoors,
Occupied / Unoccupied by Indoor and Central control
only wired remote controller is able to set this function as existing way) ○ ○ - - - - ○ ○ ○ ○
3 Scheduling Function ○ ○ * Wired remote controller or central controller must be installed
(Sub Func. Enable) 2) Synchronization icon with remote controller
(Function can be activeated using just one control device.)
(Synchronization Monitoring)
* Combined with MULTI V WATER S outdoor unit, this function is not available.
7 Indoor unit address checking Wired remote controller can check indoor unit address information ○ - ○ ○ ○ - - - - - - -
* Central controller has been installed, CH230 error code can be recognized
(Old/New Same)
Refrigerant Leakage ○ ○ ○ - - - - ○ ○ -
8
Detection
Function error sign display when refrigerant leakage occurred ○ ○ * Without Central Controller, it is able to recognize with wired remote controller (CH230)
* Combined with MULTI V WATER S outdoor unit, this function is not available.
* Accessory PRLDNVS0 must be separately ordered
Thermo On / Off range User can set cooling thermo on/off range with wired remote ○ ○ ○ - - - - - - -
9
Setting (Cooling) controller for prevention overcooling
○ - * Thermo On / Off temperature setting (3 step)
Thermo On / Off range User can set heating thermo on/off range with wired remote ○ (4 step) ○ (4 step) ○ (3 step) ○ (3 step) ○ (3 step) - - - - -
10
Setting (Heating) controller for prevention overheating. (4 Steps)
○ - * Thermo On / Off temperature setting (4 step)
Static Pressure
Depends on the installation environment, 4th generation Ceiling
11 Step Control
11 Concealed Duct can control the static pressure by 11 steps for ○ - * Only applied in Ceiling Concealed Duct ○ ○ ○ ○ ○ - - - - -
(Only for Ceiling
providing comfortable environment
Concealed Duct Type)
Filter Sign The alarm activates when the filter needs to be cleaned, * The alarm activates on the central controller, but the remaining time is
13 ○ ○ ○ ○ ○ - - ○ ○ ○ ○ ○
(Remaining Time) and the time remaining for cleaning is displayed on the screen. not displayed.
Auto restart function After the power failure compensation, stand by at OFF mode
14 ○ - ○ ○ ○ - - - - - - -
Disable / Enable Restore the operation for the status before the power off
15 Indoor Humidity display Monitoring indoor humidity Wired Remote Controller ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -
16 Comfort Cooling setting set the outdoor unit Comfort cooling operation value ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -
17 Smart Load Control setting Change the outdoor unit’s Smart Load Control stage value. ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -
19 Low noise mode time setting set the start and end time of the outdoor unit’s low noise mode operation ○ ○ * Available only with MULTI V 5 - ○ - - - - ○ ○ ○ -
Note : 1) No.1, 2, 3, 8 : Functions are available to use together with 4th generation Indoor units only. If used together 2nd generation indoor unit and ※ ○ : Applied, - : Not applied
4th generation indoor unit functions will not be activate. Combined with MULTI V Water S outdoor unit this function is not available
2) No. 4, 5, 6, 7, 9, 10, 11, 12, 13, 14 : If used together 2nd generation indoor unit and 4th generation indoor unit these functions will be activate only in 4th generation indoor
3) 2nd generation indoor unit : Ceiling & Floor Convertible Unit, Ceiling Suspended Unit, HYDRO KIT (Low Temp. / High Temp.), ERV DX (with Humidifier, without Humidifier),
AHU Communication Kit
142 143
INDOOR UNITS _ COMPATIBILITY INDOOR UNITS _ FEATURE FUNCTIONS
INDOOR UNITS
Premium Standard llI Standard ll Simple Simple for Hotel Wireless Dry Contact Wired Remote Controller Wireless
Controller Controller Name Remote Wi-fi Controller
Premium Standard III Standard II Simple Simple(Hotel) Controller
Product PREMTA000
PREMTA000A PREMTBB10 PREMTB100 PREMTBB01 PREMTB001 PQRCVCLOQ PQRCVC0QW PQRCHCA0Q PQRCHCA0QW PQWRHQ0FDB
Simple Dry
Contact
2 points Dry Dry Contact for
Contact Thermostat
For Modbus
PDRYCB500
PREMTA000B PDRYCB000 PDRYCB400 PDRYCB300
Time Display ○ ○ ○ - - ○ -
Console ARNU-A4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Humid. Display ○ ○ - - - - -
※ ○ : Compatible, △ : Need wired remote controller / IR receiver, - : Not compatible ※ ○ : Applied, - : Not Applied
1) It has a separate remote controller 1) It might not be indicated or operated at the partial product
2) Centralized control (PACEZA000 / PACS5A000 / PACP5A000 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
3) For ceiling type duct
Note.
- Indoor unit should have functions requested by the controller
- If you need more detail, please refer to the manual of product. (http://partner.lge.com: Home> Doc.Library> Manual)
144 145
HOT WATER
SOLUTION
HOT WATER
SOLUTION
HYDRO KIT
146 147
HOT WATER SOLUTION _ HYDRO KIT HOT WATER SOLUTION _ HYDRO KIT _ KEY FEATURES
HOT WATER
SOLUTION
- Cooling / Floor Heating / Sanitary Hot Water for 10 years High Temperature Technology
- Cooling : MULTI V IV Indoor Unit
Pressure
Water
- Floor Heating : Medium Temp. HYDRO KIT (1ea)
- Sanitary Hot Water : High Temp. HYDRO KIT (2ea), Sanitary Hot Water Tanks
- Electricity Cost : Average Cost in EU R410A
- Gas Cost : Average Cost in EU
R134A
- Oil Cost : Average Cost in EU Stage 1
Stage 2
Air
Initial Costs Annual Operating Costs
Enthalpy
15,000
20,000
30,000
Hot water+ Radiant heating HR unit (Cooling & Hot water) Thermal Storage System Heat Recovery
Energy costs can be minimized by reusing the wasted heat
from indoor units. Hotel Application
It is possible to operate
Conventional
cooling and heating constantly
System Diagram Eco-friendly Green Energy Solution Absorbed heat is released to outdoor air.
at the same time during the
Providing a total solution by heat pump, air conditioning Green energy solution through the reduction of CO2 Heat Transfer summer, to provide hot water
(cooling by refrigerant & chilled water, heating by emmisions. Heat
Released
for bathrooms by using waste
refrigerant & hot water) and domestic hot water supply. pump
Conventional System
Hot water Heat
Absorption
heat energy of indoor cooling.
CO2 Emissions
Refrigerant piping Water piping
(%)
Conventional Boiler Domestic
HR Unit Hot Water Tank
Indoor Unit 120
Hot Water Supply Cooling
Domestic
100%
Hot Water Tank HYDRO KIT
100
76% Absorbed heat from indoor space is used for making hot water. Office Application
Air Hot water can be supplied
Hot water conditioning 60
HYDRO KIT Heat Transfer at all times in the office by
supply
MULTI V 5 40 30%
On Average
HR Unit
pump
cooling the HR unit to
High temperature Hot water Heat
Absorption
warm up the sanitary tank,
20 using waste energy.
MULTI V 5 Domestic
Hydro Kit
Oil Gas (Heat Recovery) Hot Water Tank
Boiler Boiler
MULTI V Hot Water Supply Cooling
Outdoor Unit Floor heating
(Water Cooled) Middle temperature
148 149
HOT WATER SOLUTION _ HYDRO KIT _ SPECIFICATION
HYDRO KIT
HOT WATER
SOLUTION
Model Unit ARNH04GK2A4 ARNH10GK2A4 Model Unit ARNH04GK3A4 ARNH08GK3A4
Cooling Capacity kW 12.3 28.0 Heating Capacity kW 13.8 25.2
Heating Capacity kW 13.8 31.5 Power Input
Nominal W 2,300 5,000
Power Input (H / M / L)
Nominal W 10 10 Exterior Color Morning Gray Morning Gray
(H / M / L)
Exterior Color Morning Gray Morning Gray RAL Code RAL 7030 RAL 7030
RAL Code RAL 7030 RAL 7030 Dimensions Body mm 520 x 1,080 x 330 520 x 1,080 x 330
Dimensions Body mm 520 x 631 x 330 520 x 631 x 330 (W x H x D) Shipping mm 682 x 1,168 x 423 682 x 1,168 x 423
(W x H x D) Shipping mm 677 x 687 x 418 677 x 687 x 418 Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Gas Side mm (inch) Ø15.88 (5/8) Ø19.05 (3/4)
Pipe Connections
Gas Side mm (inch) Ø15.88 (5/8) Ø22.2 (7/8) Drain Pipe (Internal Dia.) A (inch) 25A (Male PT 1) 25A (Male PT 1)
Connections
Drain Pipe (Internal Dia.) A (inch) 25A (Male PT 1) 25A (Male PT 1) Water Pipe Inlet A (inch) 25A (Male PT 1) 25A (Male PT 1)
Water Pipe Inlet A (inch) 25A (Male PT 1) 25A (Male PT 1) Connections Outlet A (inch) 25A (Male PT 1) 25A (Male PT 1)
Connections Outlet A (inch) 25A (Male PT 1) 25A (Male PT 1) Weight Body kg 87.0 92.0
Weight Body kg 29.2 33.7 Sound Pressure Levels (H / M / L) dB(A) 43 46
Sound Pressure Levels (H / M / L) dB(A) 26 26 1, 220 ~ 240, 50 1, 220 ~ 240, 50
Power Supply Ø, V, Hz
1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
1) Nominal : Performance tested under EN14511
1) Nominal : Performance tested under EN14511 Note : 1. Capacities are based on the following conditions :
Note : 1. Capacities are based on the following conditions : - Heating : Indoor 20°C (68°F) DB / 15°C (59°F) WB, Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB, Water Inlet 55°C (131°F) / Outlet 65°C (149°F)
- Cooling : Indoor 27°C (80.6°F) DB / 19° C (66.2°F) WB, Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB, Water Inlet 23°C (73.4°F) / Outlet 18°C (64.4°F) 2. Piping Length : Interconnected Pipe Length = 7.5m
- Heating : Indoor 20°C (68°F) DB / 15°C (59°F) WB, Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB, Water Inlet 30°C (86°F) / Outlet 35°C (95°F) 3. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Piping Length : Interconnected Pipe Length = 7.5m 4. MULTI V S 4HP (ARUN040GSS0, ARUN040LSS0) cannot be connected to Hydro Kit.
3. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. 5. MULTI V Water S cannot be connected to Hydro Kit.
4. MULTI V S 4HP (ARUN040GSS0, ARUN040LSS0) cannot be connected to Hydro Kit.
5. MULTI V Water S cannot be connected to Hydro Kit.
6. Anti freezing liquid should be added under 10°C (outdoor temp.) during cooling mode.
Accessories Accessories
Chassis ARNH04GK2A4 ARNH10GK2A4 Chassis ARNH04GK3A4 ARNH08GK3A4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module ○ Independent Power Module ○
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) - Pre Filter (washable / anti-fungus) -
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB300 (8 points for thermostat compatible) PDRYCB300 (8 points for thermostat compatible)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
150 151
VENTILATION
SOLUTIONS
VENTILATION
SOLUTIONS
ERV / ERV WITH DX COIL
152 153
VENTILATION SOLUTIONS _ ERV VENTILATION SOLUTIONS _ ERV _ KEY FEATURES
HIGH EFFICIENCY
High Efficient Heat Exchanger
ERV Efficiency and comfort is ensured through the high-efficiency
energy recovery central core which recovers energy from
CO2 Auto Operation
LG ERV reduces energy loss with auto fan speed control
following CO2 level
the indoor air and transfers it to the fresh incoming air Fine CO2 level
High occupancy Low occupancy CO2 level
without mixing airstream.
(high CO2 level) (low CO2 level) Fan speed
9 o’clock 10 11 12 13 14 15 16 17
* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
** Energy saving ratio can be differed by weather condition.
※ Test Condition - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
VENTILATION
SOLUTIONS
- ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM.
Return
Air Low temp.
Heat recovery
Supply
mode
Air
Outdoor Month Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Dec.
Outdoor Air Indoor Air Air
Heat recovery mode Bypass mode
Outdoors Indoors Total Heat Exchanger
Indoor Outdoor Indoor Outdoor
Automatic
Change
Damper Damper
Night Time Free Cooling Heat Exchanger Heat Exchanger
* This function is operated with ‘Auto’ mode by wired remote control.
Discharge the indoor heat in the summer night and supply ** Energy saving ratio can be differed by weather condition.
cool outdoor air to indoors. so it can save energy. ※ Test Condition: - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
- ERV (1,000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM.
NECESSITY OF ERV Afternoon Night Morning
Natural ventilation loss cooling, heating energy when exhausting polluted air inside. Heat exchanger in ERV collects the cooling,
Delay Operation
When you turn on the air conditioner and ERV at the same
heating energy to save energy while supplying fresh air.
time, Delay Operation can reduce unnecessary heating and
Energy Recovery Ventilation (ERV) Indoor lemp Outdoor lemp Set Temp. cooling energy loss slows down automatically ERV operation.
(winter) ERV makes inside coolier Inside Temp.
22℃ -5℃
with bypass mode like Outside Temp. Coperation Delay operation
natural ventilation
Operation starts with air conditioner simultaneously. Operation starts with air conditioner
Natural Ventilation
Inside is getting
higher in the night
2% Energy Saving
(Annually)
because of business
machines.
Office time
starts
* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
Outdoor lemp Indoor lemp ** Energy saving ratio can be differed by weather condition. Operation
-5℃ 22℃
-5℃ time
※ Test Condition
154 155
VENTILATION SOLUTIONS _ ERV _ KEY FEATURES
CO2 sensor senses indoor CO2 level and displays it on new wired remote controller. Convenient
• Flexible display EAEA
(Exhaust
(Exhaust
- Dual display with air conditioner. air outlet)
air outlet)
- Zoom selected directory to increase legibility.
Exhausting operation causes
negative indoor air pressure,
Ceiling Fixing Bolt and cannot fully ventilate.
Easy
• Navigation buttons, easy to use.
(M10~12) OAOA
(Fresh
(Fresh
• Easy installation setting air outlet)
air outlet)
Nut
150~250
Min.600
Visible Inspection
150~250
Min.600
Inspection
Main display Further information partpart
• Indoor CO2 level
Washer, Spring Lock Exhausting and Supplying 450(600)
450(600)
If the CO2 level is above 900ppm in CO2 level and room condition are • Alarm for filter change / Remained time to change filters Fast Ventilation Mode Simultaneously
the room, the red mark is on. displayed continuously. Washer, Plain Air supply
grillegrille
VENTILATION
Air supply
SOLUTIONS
(user-supplied)
(user-supplied)
Monitoring CO2 Nut Maintenance
Maintenance space
space
CO2 1215 ppm
Group Control
tal heat
tal heat Exchanger
Exchanger
Air Filter
Air Filter
2,500
Closed Open Closed Open H Duct
M
1) 16 units (Including ERV, air conditioner) + 1 remote controller L
1,000
Duct
Heat Connection Flange
Insulating Material
Heat exchanger and filter Heat exchanger
Aluminium
ERV
VENTILATION
Power Input SH / H / L W 97 / 87 /52 150 / 125 / 60 247 / 230 / 95 Power Input SH / H / L W 328 / 266 / 144 463 / 370 / 208 660 / 530 / 290 926 / 740 / 420
SOLUTIONS
Air Flow SH / H / L m³/h 250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 Air Flow SH / H / L m³/h 800 / 800/ 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
External Static Pressure SH / H / L Pa 100 / 70 / 50 150 / 100 / 50 150 / 100 / 50 External Static Pressure SH / H / L Pa 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50
ERV Mode Temperature Exchange ERV Mode Temperature Exchange
SH / H / L % 80 / 80 / 83 80 / 80 / 82 79 / 79 / 82 SH / H / L % 82 / 82 / 83 80 / 80 / 81 82 / 82 / 83 80 / 80 / 81
Efficiency Efficiency
Enthalpy Exchange Heating (SH / H / L) % 70 / 70 / 72 75 / 75 / 80 75 / 75 / 78 Enthalpy Exchange Heating (SH / H / L) % 73 / 73 / 76 71 / 71/ 73 73 / 73 / 76 71 / 71/ 73
Efficiency Cooling (SH / H / L) % 66 / 66 / 68 71 / 71 / 75 68 / 68 / 75 Efficiency Cooling (SH / H / L) % 66 / 66 / 70 64 / 64 / 67 66 / 66 / 70 64 / 64 / 67
Sound Pressure Level SH / H / L dB(A) 29 / 28/ 24 35 / 32 / 26 37 / 36 / 28 Sound Pressure Level SH / H / L dB(A) 40 / 36 / 32 40 / 37 / 33 43 / 39 / 35 43 / 40 / 36
Sound Power Level SH / H / L dB(A) 50 53 / 50 / 42 57 / 56 / 46 Sound Power Level SH / H / L dB(A) 56 / 53 / 47 59 / 56 / 52 59 / 56 / 50 62 / 59 / 55
Operating Step Super-high / High / Low Operating Step Super-high / High / Low Super-high / High / Low
Current SH / H / L A 0.70 / 0.60 / 0.42 1.05 / 0.90 / 0.50 1.65 / 1.56 / 0.80 Current SH / H / L A 2.13 / 1.75 / 1.00 2.92 / 2.38 / 1.40 4.26 / 3.50 / 2.00 5.92 / 4.76 / 2.80
Power Input SH / H / L W 97 / 87 /52 150 / 125 / 60 247 / 230 / 95 Power Input SH / H / L W 328 / 266 / 144 463 / 370 / 208 660 / 530 / 290 926 / 740 / 420
Bypass Mode Bypass Mode
Air Flow SH / H / L m³/h 250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 Air Flow SH / H / L m³/h 800 / 800/ 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
External Static Pressure SH / H / L Pa 100 / 70 / 50 150 / 100 / 50 150 / 100 / 50 External Static Pressure SH / H / L Pa 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50
Sound Pressure Level SH / H / L dB(A) 29 / 29/ 25 35 / 33 / 26 37 / 37 / 28 Sound Pressure Level SH / H / L dB(A) 41 / 37 / 33 41 / 38 / 34 44 / 40 / 36 44/ 41 / 37
Qty EA 4 Qty EA 4 4+2
Duct Work Duct Work
Size (Φ) mm Φ200 Size (Φ) mm Φ250 Φ250 + Φ350
Qty EA 1 Qty EA 1 2
Supply Air Fan Supply Air Fan
Type Direct-Drive Sirocco Type Direct-Drive Sirocco Direct-Drive Sirocco
Qty EA 1 Qty EA 1 2
Exhaust Air Fan Exhaust Air Fan
Type Direct-Drive Sirocco Type Direct-Drive Sirocco Direct-Drive Sirocco
Qty EA 2 Qty EA 2 4
Filters Type Cleanable fibrous fleeces Filters Type Cleanable fibrous fleeces Cleanable fibrous fleeces
Size (W x H x D) mm 855 x 10 x 166 Size (W x H x D) mm 1,148 x 6 x 245 1,148 x 6 x 245
Note : 1. ERV mode : Total Heat Recovery Ventilation mode Note : 1. ERV mode : Total Heat Recovery Ventilation mode
2. * : Refer to dimensional drawings. 2. * : Refer to dimensional drawings.
3. Noise level : 3. Noise level :
- The operating conditions are assumed to be standard - The operating conditions are assumed to be standard
- Sound measured at 1.5m below the center the body. - Sound measured at 1.5m below the center the body.
- Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
- The sound level at the air discharge port is about 8 dB(A) higher than the unit's operating sound. - The sound level at the air discharge port is about 8 dB(A) higher than the unit’s operating sound.
4. Temperature and Enthalpy Exchange Efficiency at cooling Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH 4. Temperature and Enthalpy Exchange Efficiency at cooling Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH
5. Temperature and Enthalpy Exchange Efficiency at heating Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH 5. Temperature and Enthalpy Exchange Efficiency at heating Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH
6. Temperature Exchange efficiency is tested at heating condition. 6. Temperature Exchange efficiency is tested at heating condition.
Accessories Accessories
Chassis LZ-H025GBA4 LZ-H035GBA5 LZ-H050GBA5 Chassis LZ-H080GBA5 LZ-H100GBA5 LZ-H150GBA5 LZ-H200GBA5
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector - Refrigerant Leakage Detector -
EEV Kit - EEV Kit -
Independent Power Module - Independent Power Module -
Robot Cleaner - Robot Cleaner -
Pre Filter (washable / anti-fungus) - Pre Filter (washable / anti-fungus) -
Ion Generator - Ion Generator -
CO2 Sensor ○ CO2 Sensor ○
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) - External Input (1 point) -
Wi-Fi - Wi-Fi -
※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied
Option : Refer to model name in table Option : Refer to model name in table
158 159
VENTILATION SOLUTIONS _ ERV WITH DX COIL _ KEY FEATURES VENTILATION SOLUTIONS _ ERV WITH DX COIL _ SPECIFICATION
VENTILATION
SOLUTIONS
Pressure Feed Water Mpa 0.02 ~ 0.49 -
Heat Exchange Mode (SH / H / L) dB(A) 38 / 36 / 33 39 / 37 / 34 40 / 38 / 35 39 / 37 / 35 41 / 38 / 36 41 / 39 / 36
Sound Pressure
Bypass Mode (SH / H / L) dB(A) 39 / 37 / 34 40 / 38 / 35 40 / 38 / 35 39 / 37 / 35 41 / 38 / 36 41 / 39 / 36
Refrigerant R410A
Power Supply Ø / V / Hz 1 / 220 ~ 240 / 50, 60
Total Air Conditioning Solution Power Input
(Nominal)
Heat Exchange Mode (SH / H / L) kW 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27
Bypass Mode (SH / H / L) kW 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27
LG ERV DX can be used as a Total Air Conditioning Solution. It can control condition of incoming air with the DX coil Nominal Running Heat Exchange Mode (SH / H / L) A 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3
and humidifier for making comfortable indoor air. In the summer, LG ERV DX controls the air indoors by cooling and Current (RLA) Bypass Mode (SH / H / L) A 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3
Air to air cross flow total heat Air to air cross flow total heat
dehumidifying incoming air. In winter, it can provide warm air by heating and humidifying the incoming air. Heat Exchange System
(sensible + latent heat) exchange (sensible + latent heat) exchange
Heat Exchange Element Specially processed non-flammable paper Specially processed non-flammable paper
Air Filter Multidirectional fibrous fleeces Multidirectional fibrous fleeces
Dimensions WxHxD mm 1,667 x 365 x 1,140 1,667 x 365 x 1,140
Heat exchange DX Coil Humidification Net Weight kg 105 98
Liquid mm Ø6.35 Ø6.35
Gas mm Ø12.7 Ø12.7
Piping Connection
Water mm Ø6.35 -
Supply Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1)
Exhaust
Air Connection Duct Diameter mm Ø250 Ø250
Air
Note : 1. Cooling Capacity Test condition - Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB
2. Heating Capacity Test condition - Indoor temperature : 20°C DB / Outdoor temperature : 7°C DB, 6°C WB
3. Humidifying capacity is based on the following conditions - Indoor temperature : 20°C DB, 15°C WB / Outdoor temperature : 7°C DB, 6°C WB
4. Cooling and heating capacities are based on the following conditions. : Fan is based on High and Super-high.
5. The operating sound measured at the point 1.5 m below the center of the unit is converted to that measured at an anechoic chamber.
6. The specifications, designs and information here are subject to change without notice.
Outdoor Return
Air Air
Accessories
Interlocking with MULTI V Chassis LZ-H050GXH4 LZ-H080GXH4 LZ-H100GXH4 LZ-H050GXN4 LZ-H080GXN4 LZ-H100GXN4
LG ERV DX can be interlocked with MULTI V. It can be controlled individually by a wired remote controller connected Drain Pump -
to MULTI V indoor units. Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0
EEV Kit -
Indoor Units ERV DX Independent Power Module -
Robot Cleaner -
Pre Filter (washable / anti-fungus) -
Ion Generator -
CO2 Sensor AHCS100H0
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact)
Dry Contact (with additional accessory)
PDRYCB500 (Modbus)
External Input (1 point) ○
Wi-Fi -
Outdoor ※ ○ : Applied, - : Not applied
Option : Refer to model name in table
160 161
CONTROL
SOLUTIONS
INDIVIDUAL CONTROL / CENTRALIZED CONTROL
INTEGRATION DEVICE
162 163
LG CONTROL SOLUTIONS
MULTI V 5 offers a diverse range of effective control solutions that satisfy specific needs of each building and its user scene.
These controlling systems are equipped with user friendly interface, flexible interlocking environment, energy management and
smart individual controller for optimized controlling conditions and smart building management.
HOTEL OFFICE
• Energy Management
SOLUTION
CONTROL
• External Device
Power Distribution Solution Smart Individual Control Solution Small Central Control Solution
Integration Solution
164 165
INDIVIDUAL CONTROL
FEATURE FUNCTIONS
INDIVIDUAL Controller Name
Premium
Wired Remote Controller
CONTROL
Model Name
PREMTA000
PREMTB100 PREMTB001 PQRCVCL0Q PQRCHCA0Q
PREMTA000A PQWRHQ0FDB PWFMDD200
PREMTBB10 PREMTBB01 PQRCVCL0QW PQRCHCA0QW
PREMTA000B
On / Off ○ ○ ○ ○ ○ ○ ○
Temperature Setting ○ ○ ○ ○ ○ ○ ○
Mode Change ○ ○ ○ ○ - ○ ○
Auto Swing ○ ○ ○ ○ ○ ○
Vane Control
○ ○ ○ ○ ○ ○ ○
Basic (Louver Angle)
E.S.P
○ ○ ○ ○ ○ - -
(External Static Pressure)
Electric Failure
○ ○ ○ ○ ○ - ○
Compensation
SOLUTIONS
(Child Lock)
CONTROL
Schedule / Timer Weekly~Yearly Weekly~Yearly Weekly - - Sleep / On / Off Weekly
Time Display ○ ○ ○ - - ○ -
Humid. Display ○ ○ - - - - -
Advanced Lock
(mode, set point, set point Advanced Lock Advanced Lock Mode Lock - - - -
range, On / Off Lock)
Advanced
Filter Sign ○ ○ ○ - - - -
Energy Management 2) ○ ○ ○ - - - -
Human Detection - ○ - - - - -
Temp, Humidity
○ ○ - - - - -
Compensation
ETC Display 5 inch Color 4.3 inch Color 4.3 inch mono 2.6 inch mono 2.6 inch mono 2 inch mono -
Size (W x H x D, mm) 137 x 121 x 16.5 120 x 120 x 16 120 x 120 x 16 64 x 120 x 15 64 x 120 x 15 51 x 153 x 26 -
166 167
INDIVIDUAL CONTROL
SOLUTIONS
CONTROL
- Instantaneous power monitor ※ ○ : Applied, - : Not Applied
1) It might not be indicated or operated at the partial product Auto Changeover (Convenience)
- Energy consumption check 2) This function is available for duct type Temperature
3) This function requires PDI (PQNUD1S40 / PPWRDB000) to be installed. - The indoor unit automatically manages room temperature
(power consumption, operation time) Note : 1. Indoor unit needs to have functions requested by the controller
with heating and cooling with extended setting temperature
- Temp. Setback Timer, Time Limit Control 2. 2 set points control works normally with MULTI V Heat Recovery and Single Split Cooling set point
Heat Pump. But in case of MULTI V Heat Pump, It may not work properly ranges. With setting heating and cooling set temp. just one for Unoccupied Cooling
- Target setting (ODU Capacity, Instantaneous power…etc)
time, comfortable condition will continue at all times. Cooling Set Point
• Group Control for Occupied
Occupied Unoccupied
- Up to 16 Indoor units can be controlled with one Setback (Home Leave) (Energy saving & Comfort) Heating Set Point
for Occupied
remote control - In the absence, room temperature can be kept in the range of Heating
Heating Set Point
• External Device On / Off (1 point) 2 set points instead of power off. It provides comfortable indoor for Unoccupied
Cooling Heating
- Customized interlocking control with indoor unit is environment quickly when the mode is changed to occupied.
Time
possible without dry contact * This function is for Heat Recovery system or Single heat pump. Otherwise it is not Arrive at a room Leave a room
• 2 Set Points Control guaranteed.
Thermo-off
- Increase convenience and comfort Indoor temperature
- Auto changeover, Setback (home leave)
Touch Button
Schedule Function
Easy Checking Schedule Exception Day settings
Energy Contents Standard III remote controller Convenient settings are possible
provides clock type daily schedule. with schedule exception settings.
Error History
168 169
INDIVIDUAL CONTROL
SOLUTIONS
2) This function is available for duct type
CONTROL
SIMPLE WIRED REMOTE CONTROLLER
- Main display simple mode 3) This function requires PDI (PQNUD1S40 / PPWRDB000) to be installed.
4) For ceiling type ducted unit
- 5 inch color LCD Note : 1. Indoor unit needs to have functions requested by the controller
2. 2 set points control works normally with MULT V Heat Recovery and Single Split Heat
• Energy Saving Functions Pump. But in case of MULTI V Heat Pump, It may not work properly
- Instantaneous power monitor A simple way to control office or hotel systems in a compact design
- Energy consumption check
(power consumption, operation time) Model Name PQRCVCL0QW / PQRCHCA0QW /
PQRCVCL0Q PQRCHCA0Q
- Temp. Setback Timer, Time Limit Control On / Off ○ ○
- Target setting (ODU Capacity, Instantaneous power…etc) Fan Speed Control ○ ○
Temperature Setting ○ ○
• Group Control Cooling / Heating / Auto / Only Changeable by Central
Mode Change
- Up to 16 Indoor units can be controlled with one remote control Dehumidification / Fan Controller
Auto Swing ○ -
• 2 Set Points Control Vane Control (Louver direction) ○ -
- Increase convenience and comfort E.S.P (External Static Pressure) ○ ○
Electric Failure Compensation ○ ○
- Auto changeover, Setback (home leave) PQRCVCL0QW (White) / PQRCHCA0QW (White) / Child Lock ○ ○
PQRCVCL0Q (Black) PQRCHCA0Q (Black) Indoor Temperature Display ○ ○
Wireless Remote Controller
Easy Energy Management Receiver
○1) ○1)
Full Touch
Screen
- Check the operation hour or electricity usage
- Comparison of usage compared to last year
Features & Benefit Size (W x H x D, mm)
Blacklight
70 x 121 x 16
○
70 x 121 x 16
○
- Set the target usage and time • Small remote control with minimal functionality ※ ○ : Applied, - : Not Applied
1) For ceiling type ducted unit
Note : Indoor unit needs to have functions requested by the controller
Easy Scheduling
- Daily, Weekly, Yearly schedule function
- Schedule pattern setting
170 171
INDIVIDUAL CONTROL
LG Wi-Fi MODEM
Control LG air conditioners via using the internet devices as Android or iOS smartphones. Connected Diagram
Model Name PWFMDD200
Size (W x H x D, mm) 48 x 68 x 14
Interfaceable Products MULTI V Indoor unit 3)
Connection Type Indoor unit 1:1
Communication Frequency 2.4 GHz ➋
Wireless Standards IEEE 802.11b/g/n
LG SmartThinQ (Android v4.1(Jellybean) or higher,
Mobile Application
iPhone iOS 9.0 or higher)
PWFMDD200 Optional Extension Cable PWYREW000 (10m extension)
1) Vane Control may not be possible according to the type of Indoor unit ➊ ➊ ➌
2) LG Centralized controller and PDI installation is required for this function
Features & Benefit 3) For the compatibility with Indoor unit, please contact regional LG office
Note : 1. Functionality may be different according to each IDU model
2. User interface of application shall be revised for its design and contents improvement
• Access LG air conditioner anytime and from anywhere 3. Application is optimized for smartphone use, so it may not be well functioning with tablet
with Wi-Fi equipped device. devices Internet
Service Provider
It is possible to check whether the air conditioner is Wireless AP
turned off when the user goes out (energy saving), and (Router)
can be operated in advance before entering the house
(comfort improvement). Connection (Pairing) Order
• LG’s exclusive Home Appliances control app(SmartThinQ) ➊ Make LG account on LG Smart ThinQ and select the Router that will use
is available ➋ Insert passwords of selected router and do set AP by LG remote controller
• Simple operation for various functions ➌ Confirm the pairing between Wi-Fi Modem and Router
- On / Off
SOLUTIONS
CONTROL
- Operation Mode
- Current/Set Temperature
- Fan Speed Smart ThinQ
- Vane Control 1)
- Reservation (Sleep, Weekly On / Off) Simple operation for various functions
Controlling Reservation Energy
- Energy Monitoring 2) & Monitioring Monitoring On / Off, Current Temp Mode, Set Temp Vane Control
- Filter Management
- Error Check
Overview
Wi-Fi
Modem ThinQ Server
USB Wire
Control panel
USB cable Wi-Fi modem
* Each indoor unit has a Wifi modem installation location inside the product, and it can be installed by exposure if necessary.
172 173
CENTRALIZED CONTROL
SOLUTIONS
CONTROL
Auto Changer Over - ○ ○ 4) ○ 4) ○ 4) ○
174 175
CENTRALIZED CONTROL
AC EZ TOUCH
Smart management with 5 inch touch screen for small site. Energy Mode Schedule
When using energy mode function, operation mode Schedule control allows user to set the events in advance
Model Name PACEZA000 changes from cooling to fan or heating to off mode by force. to maximize system performance. Also, by blocking
Size (W x H x D, mm) 137 x 121 x 25 (It is available only ‘on’ mode indoor unit) unnecessary operation, it prevents a waste of energy.
Interfaceable Products MULTI V / ERV / ERV DX / HYDRO KIT / THERMA V
Maximum number of units 64
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Error Check ○
Slave Mode (Interlocking with
○
PACEZA000 higher level controller)
Schedule Weekly / Monthly / Yearly / Exception day
Remote Access By client S/W
Features & Benefit Emergency Stop & Alarm
○
Display
• Remote Access with Graphical User Access Control
Power Consumption Monitoring
○
• Total 200 Schedule Events (with PDI)
• Energy saving mode Auto Changeover / Setback ○ Alarm Indicator Group / Individual Control
• Energy Monitoring (with PDI) Temperature Limit ○ It works when there are some errors or it’s time to change According to the situation, it can be controlled by group or
Operation History Error record the filter. Users can respond immediately according to alarm each indoor unit. It is useful to monitor or control for the
• 2 Set point function (Upper/Lower Temperature setting)
ODU Low Noise 1) ○
• Temperature Set points Range Limit indicator therefore HVAC system is monitored consistently. best fit of request.
Daylight Saving Time ○
• Remote Controller Lock (All, Temp, Mode, Fan Speed)
External IO Port DI 1
• Operation History
IPv6 Support ○
• Change alarm (Filter change)
※ ○ : Applied, - : Not Applied
• Emergency stop 1) It is only available in some products
SOLUTIONS
CONTROL
Overview
IDU
...
PC Internet AC EZ TOUCH
...
IDU AC EZ
Easy to manage up to 32 indoor units, including ERV with simple interface.
* IPv6 supported
Features & Benefit
• 32 indoor units control
• Weekly Schedule
• Individual / Group Control
Internet
Appropriate PI 485 should be • MULTI V 5 • MULTI V • MULTI V S • MULTI SPLIT • ERV
used according to PDB • MULTI V IV WATER IV • SINGLE SPLIT
• MULTI V III • MULTI V
• MULTI V II WATER II
176 177
CENTRALIZED CONTROL
AC SMART 5
Control LG air conditioners via using the internet devices as Android or iOS bases smartphones. BMS Integration Advanced Network Accessibility
Without additional device, AC Smart 5 provides BACnet IP / Modbus TCP AC Smart 5 reflects the state of the art of network technology trend. IPv6
Model Name PACS5A000 interface for BMS (Building Management System) integration as well as its own (Internet Protocol version 6), which is the most recent version of the Internet
Size (W x H x D, mm) 253.2 x 167.7 x 28.9 management function. Protocol, provides accessibility to the IPv6 compatible network environment.
MULTI V / ERV / ERV DX / HYDRO KIT / In addition, HTML5 allows you to easily control LG HVAC system on a variety
Interfaceable Products
THERMA V / AHU kit / LG Chiller 1) of platforms (PC, Mobile, Tablet), at any time and from any location, not just
Maximum number of units 128 on the touch screen.
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Comfort Cooling / ODU Low Noise / ODU Defrost Mode / BMS
Advanced Function Setting and
Comfort Level display / CO2 Level display (for ERV / BACnet over IP
Display 2)
ERV DX) / Night Time Free Cooling (for ERV / ERV DX)
Error Check ○
PACS5A000 Slave Mode (Interlocking with
○
higher level controller) IPv6
Schedule Weekly / Monthly / Yearly / Exception day Network
Features & Benefit Web Access ○
Emergency Stop & Alarm
○
• The central controller allows control of the LG Display
Power Consumption Monitoring
HVAC system to various platforms. (with PDI)
○ HTML5 web design
(Touch screen, PC, Smartphone, Tablet) Auto Changeover / Setback ○
Temperature Limit ○
- DI : 2 / DO : 2 Operation Time Limit ○
- Max. 128 IDU control Visual Navigation ○
Operation Trend ○
- BACnet IP/Modbus TCP
Interlock Control ○ Energy Management / Operation Trend Visualized Control
- Schedule Virtual Group Control ○
Energy navigation function allows air conditioners operation to be managed Visual navigation enables controlling and monitoring the unit on floor plan
- Map View (Visual Navigation) ODU Capacity Control ○
under the monthly (Weekly / Yearly) plan of energy usage. By analyzing view for the intuitive management.
Energy Navigation (with PDI) ○
- Time limit control / Auto change over Daylight Saving Time ○
present energy consumption and comparing with the plan, overuse of system
- Energy monitoring External IO Port DI 2 / DO 2 operational costs can be prevented.
SOLUTIONS
CONTROL
BMS Integration 3) BACnet IP / Modbus TCP
- History / Operation Trend
IPv6 Support ○
- Interlock with 3rd party equipment
※ ○ : Applied, - : Not Applied
(ACS IO, ACU IO Module is needed) 1) Chiller Option Kit (PCHLLN000) is required
2) It is only available in some products
- Multi level grouping 3) For the detail point list, please refer to the installation manual
- Emergency stop & alarm
- Error alarm by E-mail
Overview
IDU
Internet AC Smart 5
...
PC
Multi Level Group Composition Interlocking with 3rd party equipment
You can freely apply layer structure such as building, floor, zone, etc. and set the AC Smart 5 can make operation scenario with 3rd party equipment by ACS IO
...
group as the same as the site composition to control and monitor the devices. Module. Control coverage is expanded. (Air conditioner only → Sensors, Fans,
Special control group You can additionally compose frequently used groups such Pumps, Switches…)
Smartphone as VIP Room, executive room, etc. regardless of the building structure.
ERV LG SAC
ODU
OR OR
Tablet Chiller AHU Air Water Hydro Kit IDUs
ACS IO Option kit AHU Controller AC Smart 5 cooled cooled
3rd party interlocking Chiller AHU Comm. kit 3rd party interlocking
Sensor Facility Sensor Facility
...
Sensor
Screw Invert Scroll
Emergency Lighting Valve Fan Expansion
Control coverage
Temp. Lighting
ACS IO
178 179
CENTRALIZED CONTROL
SOLUTIONS
BMS Integration 3) BACnet IP / Modbus TCP - Error Code
CONTROL
- History / Operation Trend IPv6 Support ○ equipment from the customer’s own Integration. - Peak Current Operating Percent
- Interlock with 3rd party equipment ※ ○ : Applied, - : Not Applied - Total Accumulate Power
(ACS IO, ACU IO Module is needed) 1) Chiller Option Kit (PCHLLN000) is required
※ ○ : Applied, - : Not Applied
2) It is only available in some products
- Multi level grouping 3) For the detail point list, please refer to the installation manual
PC * Master
... 1)
Internet
PI 485
Comm. kit
Motion Temp. CO2 Cooling Pump Centrifugal Absorption
tower PI 485 converts LG air conditioner’s protocol to the RS485 protocol for the central controller
Etc.
IPv6
Network
PHNFP14A0
180 181
CENTRALIZED CONTROL
AC MANAGER 5
Multiple ACP and AC Smart integration solution to manage multi sites up to 8,192 units as a single system. Stand-alone
Integrated with S/W program and Hardware platform, it is
Model Name PACM5A000
convenient to install since users no longer need to install
Size (W x H x D, mm) 270 x 155 x 65
program with lock-key on PC.
MULTI V / ERV / ERV DX / HYDRO KIT /
Interfaceable Products
THERMA V / AHU kit / LG Chiller 1)
Maximum number of units 8,192 (supports 32 ACP 5 or AC Smart 5)
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Error Check ○ Up to 8,192 Connections for Indoor Units Max. IDU 256 EA
...
...
Temperature Limit ○
• Schedule Operation Time Limit ○
Max. IDU 256 EA
• Map View (Visual Navigation) Visual Navigation ○ ...
• Time limit control / Auto change over Operation Trend ○
• Energy Monitoring / Navigation Interlock Control ○
• History / Operation Trend Virtual Group Control ○
• Emergency stop & alarm ODU Capacity Control ○ Advanced Network Accessibility & User Friendly GUI (reddot award)
Energy Navigation (with PDI) ○
• Error alarm by E-mail As an advanced central controller, AC Manager 5 offers flexible
• Multi Language ※ ○ : Applied, - : Not Applied
SOLUTIONS
1) Chiller Option Kit (PCHLLN000) is required interface for each user by assessing the device screen and
CONTROL
(Eng, Ita, Spa, Por, Rus, Fra, Ger, Tur, Pol, Chi, Kor) Note : AC Manager 5 requires ACP 5 or AC Smart 5
automatically customizing the layout to provide the most
optimized interface.
Overview
AC Manager 5 ACP 5 ODU / IDU & ERV
AHU
PC Comm.kit
Energy Navigation & Energy Usage Trend
Internet
Chiller & AHU Energy navigation is the function to set the target usage
Chiller Option kit AHU Controller amount to limit the monthly power consumption and to
Mobile control so that the total accumulated power consumption
does not exceed the target usage amount. It performs
total of 7 control levels with the estimated/actual usage
3rd party Device
amount exceeding ratio compared to the monthly target
usage amount. For the control method, there are indoor unit
Tablet Compressor Capacity IDU operation IDU operation
ACS IO Module operation ratio, outdoor unit capacity control, and indoor Control Ratio Control level
ODU / IDU, ERV, Chiller, AHU, 3rd party Device
unit operation control.
AC Smart 5
AC Manager 5
AC Manager 5 Control tower
Multi Level Group Composition
ACP 5 ACP 5 AC Smart 5
You can freely apply layer structure such as building, floor, zone,
etc. and set the group as the same as the site composition to
control and monitor the devices. Special control group You can
additionally compose frequently used groups such as VIP Room,
executive room, etc. regardless of the building structure.
182 183
CENTRALIZED CONTROL
SOLUTIONS
Air Conditioner Ventilator
CONTROL
• LG Central controller (for example, AC Smart) and PDI can be operated with KNX gateway. 0 : Cooling, 1 : Dehumidifying,
40001 Operate Mode Operate Mode
2 : Fan, 3 : Auto, 4 : Heating
40002 Fan Speed Fan Speed 1 : Low, 2 : Mid, 3 : High, 4 : Auto
40003 Target Temp. Target Temp. 16.0 ~ 30.0 [℃] x 10
40004 Target Temp. Limit (Upper) Target Temp. Limit (Upper) 16.0 ~ 30.0 [℃] x 10
Link BoxEIB Configuration Software for IntesisBoxⓇ KNX Serious 40005 Target Temp. Limit (Lower) Target Temp. Limit (Lower) 16.0 ~ 30.0 [℃] x 10
40006 Reserved Vent. Operate Mode 0 : HEX, 1 : Auto, 2 : Normal
Easy to use tool for the configuration of intesisBox, in a fast and effective way.
It offers the maximum integration possibilities with a minimal knowledge required on the system to be integrated. Input Register (0 x 04)
Data Bit
No. Function
Air Conditioner Ventilator
0 ~ 255
- Only needed during configuration. 30001 Error Code Error Code ※ Please refer to the
product error table.
- One single tool for the configuration of the whole range of IntesisBox KNX series gateways.
- Supplied with IntesisBox with no additional cost. 30002 Room Temp. RA Temp. -99.0 ~ 99.0 [℃] x 10
- Configuration examples for all systems that can be integrated. 30003 Pipe In Temp. OA Temp. -99.0 ~ 99.0 [℃] x 10
- Mapping table editable using excel, allowing a simple and fast association of KNX Group 30004 Pipe Out Temp. SA Temp. -99.0 ~ 99.0 [℃] x 10
Addresses, exported from ETS, to IntesisBox’s datapoints. 30005 Reserved Pipe In Temp. -99.0 ~ 99.0 [℃] x 10
LinkBoxEIB
- Includes powerful and useful features for configuration, setup and troubleshooting. 30006 Reserved Pipe Out Temp. -99.0 ~ 99.0 [℃] x 10
Configuration software
Installation Scene
Installation Scene • Single module • Multiple module
Max. 16 indoor units with a single module Max. 64 indoor units with 4 modules in one Modbus communication line
Configuration
Software Modbus RTU
LinkBoxEIB (Only Needed EIB Bus
(above 1.1.22) for Configuration) Modbus
RTU
RS232 RS485
184 185
INTEGRATION DEVICE
DEVICE
Model Name PQNUD1S40 PPWRDB000
Size (W x H x D, mm) 270 x 155 x 65
Interfaceable Products Air conditioner, ERV DX
Pulse line
ACS Central controller
SOLUTIONS
CONTROL
220 V~
ACP 5
24 V~
50kW
Measurement
MENU
AC Manager 5 70kW
SELECT
(00) ~ (03)
160kW [00] [01] [02] [03]
ACP 5 50kW
[10] [11] [12] [13]
[ Slave 1]
[ Master ] [20] [21] [22] [23]
AC Smart5 ACP
Note : 1. Power cable and type could be different from this scene depending on the Outdoor unit’s specification
2. Measured power consumption could be different between PDI and Watt meter
3. Applicable Central Controller : ACP 5, ACP Lonworks, AC Smart 5, AC Ez Touch
(Combination : we recommend to connect separated watt meter for Outdoor units to have correct power distribution value)
186 187
INTEGRATION DEVICE
This module can be connected with ACP 5 or AC Smart 5 controller if additional I/O points such as DI/DO and This module can be connected with ACP 5 or AC Smart 5 controller if additional I/O points such as UIO / UI / UO
AI/AO for 3rd party devices control and monitoring are needed. for 3rd party devices control and monitoring are needed.
Model Name PEXPMB000 ACU.UIO ACU.UO ACU.UI Module Name PEXPMB300 PEXPMB200 PEXPMB100
PACS4B000 Linkable Products PACS5A000, PACP5A000
PACP4B000
Linkable Products Communication
PACS5A000 2 ch. 1) 1 ch. 1 ch.
PACP5A000 RS-485
Communication RS-485 1 ch. Digital Input - - 3port
Digital Input 3 port Digital Output 2port 6port -
Digital Output 3 port Universal Input 2) 4port - 6port
I/O
Universal Input 1) 4 port Analog Output 2port 4port
PEXPMB000 Analog Output 4 port PEXPMB300 PEXPMB200 PEXPMB100
Value Spec Min. Max.
Value Spec Min. Max. Analog Input DC (Voltage) 0V 10V
NTC 10k 0.68k Ω 177k Ω Analog Output DC (Voltage) 0V 10V
PT 1000 803 Ω 1,573 Ω Binary Input
Digital Input - -
(Non Voltage)
Analog Input Ni 1000 871.7 Ω 1,675.2 Ω
Digital Output Normal Open - 30VDC, 1A
DC (Voltage) 0V 10V
※ ○ : Applied, - : Not Applied
DC (Current) 0mA 20mA
1) 1ch is reserved for internal communication
Analog Output - 0V 10V 2) The type of UI (Universal Input) is selectable among Digital Input and Analog Input
Binary Input
Features & Benefit
Digital Input - -
(Non Voltage)
• Interlocking with 3rd party equipment LG Central controller can make operation scenario with 3rd party equipment by ACU IO Module.
Digital Output Normal open - 30VAC / 30VDC, 2A
• Control coverage is expanded. (Air conditioner only → Sensors, Fans, Pumps, Switches …)
※ ○ : Applied, - : Not Applied
1) The type of UI (Universal Input) is selectable among Digital Input and Analog Input
SOLUTIONS
CONTROL
Features & Benefit
• Interlocking with 3rd party equipment LG Central controller can make operation scenario with 3rd party equipment by ACS IO Module.
• Control coverage is expanded. (Air conditioner only → Sensors, Fans, Pumps, Switches …) CHILLER OPTION KIT
LG central controller 5 series with Chiller Option Kit can provide LG chiller remote control and cycle monitoring.
Key Application
LG Central Control LG SAC Model Name PCHLLN000
ODU Evaporator status / Compressor status (Scroll, Screw,
Monitoring Points Centrifugal chiller only) / Condensor status /
Generator status (Abs. chiller only)
On / Off ○
Air cooled Water cooled Hydro Kit IDUs Target Temp. setting ○
AC Manager 5 ACP 5 Mode Change Scroll chiller only
ACS IO Module
3rd party interlocking Schedule ○
Sensor Facility Interfaceable Products Scroll, Screw, Centrifugal, Absorption (LG Only)
PCHLLN000
※ ○ : Applied, - : Not Applied
Expansion engineer.
Control coverage
• Chiller Option Kit installation can be proceeded with a SD Card.
Temp. Lighting
• The SD Card can install Chiller Option Kit in one LG HVAC
Solution product.
* DI : Digital Input, DO : Digital Output, UI : Universal Input, AO : Analog Output / Please contact our regional office to have connectable relay specification for analog output
Insert the SD Card in the LG HVAC Solution product. If a backup
SD Card is inserted, replace it with a ChillerOption Kit SD Card.
188 189
INTEGRATION DEVICE
DRY CONTACT
Connection between an indoor unit and external devices to control various functions. PDRYCB000
Model Name PDRYCB000 PDRYCB400 PDRYCB300 PDRYCB500 Contact Point Input
CN - CC Dry contact
Operation On / Off
Indoor Unit (Contact point linked with 3rd party)
Status
PCB
Error Alarm
CN - CC
SOLUTIONS
CONTROL
Card key
Energy Saving - (Select & Fix) - -
On / Off ○ - ○ -
CN - CC
Silent Mode - - ○ -
Fan Speed - - - ○
Operation Status ○ ○ ○ ○
* Please contact our regional office to have full compatible room controller list
Output Error ○ ○ ○ ○
Room Temp. - - - ○
PDRYCB500 <Modbus Communication Function>
※ ○ : Applied, - : Not Applied
Note : 1. Compatibility of PDRYCB300
- Can use with all types of aircon indoor units after 2010 (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console)
CN-CC
- Can not use with Single package models
- AWHP : 3 series split and monobloc models
2. Compatibility of PDRYCB400 Indoor Unit
- Can use with all types of aircon indoor units after 2010 (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console) Modbus Master Controller
...
- Can not use with single package models
- Can not use with AWHP, Hydrokit models Max. 16 Indoor units per one
3. (Select & Fix) : This function is preset by rotary switch.
One to one connection between
Modbus master controller
dry contact and indoor unit
CN-CC
Indoor Unit
* Please contact our regional office to check the compatibility with 3rd party room controller
190 191
INTEGRATION DEVICE
Note : 1 Y type Cable assembly is for connecting indoor unit and long cable. Key Application Models Applied
SOLUTIONS
2 Long Cable assembly is for connecting indoor to indoor.
CONTROL
• LG indoor units excluding Wall-Mounted Type
Extension cable
Control
box
Indoor Unit
Features & Benefit 9mm
1.6mm
• It detects the exact room temperature instead of indoor unit’s air temperature sensor
15.2mm
• Applied to Ceiling Mounted Cassette, Ceiling Concealed Duct, THERMA V and HYDRO KIT
• Extension cable (15m) is included
Main PCB
Installation Scene Extension Cable
CN-ROOM
1. Wire to the control box in the indoor unit by
Low Profile Remote
removing the existing thermistor and connect Temperature Button Sensor CN-ROOM Connector
the extension cable its place.
Indoor Unit
2. Cut the extension cable to the appropriate
length and connect the screw terminal of the
Remote Wired Remote
remote sensor. Temperature Sensor Controller
192 193
INTEGRATION DEVICE
SOLUTIONS
CONTROL
• Ceiling Concealed Duct (refer to Product Data Book for applicable models) Note : IO Module is not compatible for MULTI V III
Key Application
Wiring Diagram Demand Control Low Noise Operation
Provides variable setting for demand control according to input method to To reduce noise level , control outdoor unit’s fan speed by dry contact input.
reduce power consumption. This function supports 2 types of input signal : AI
(0 ~ 10V, 10 Step) and contact signal (3 Step).
Ceiling Concealed Duct
Max. 7 dB*
1
(dB)
2
3 DDC DDC
CN - ZONE 4 IO Module (Direct Digital Controller) IO Module (Direct Digital Controller) Timer
5
6 Capacity
7 Control with Noise Level or
8 MULTI V WATER IV
or
Contact Signal
(3 Points / 3 Steps) Contact Signal
AC 24V
Range of Operation Rate
ROOM(External) Damper AI 0 ~ 10V : 0%, 40% ~ 100%
THERMOSTAT #1 Or Relay Contact signal (3 steps) : 0%, 40% ~ 80%
MULTI V 5
Zone controller MULTI V 5 * 8 HP (22.4kW) model, Sound power level can be changed by outdoor unit operation
ROOM Damper status and low noise operation input signal.
THERMOSTAT #2 Or Relay
Gas Pipe
IO Module
3. Operation Stop 1. Sense the Gas
MULTI V 5
Alarm
Gas Gas
Sensor Sensor
Refrigerant
194 195
INTEGRATION DEVICE
PWFCKN000 PRVC2
(MULTI V WATER IV)
Features
Features Function
Function • 25°C Low ambient cooling operation by Low ambient kit and hood
• Water pump or valve control (0 ~ 10V) with damper (Analog output 0 ~ 10V)
• Minimum output voltage setting available • Demand contro
• Operation, error output (AC 250V, Max. 1A) • Low noise operation
• Dry contact input and analog output for demand control • Output outdoor or indoor unit operation status (AC 250V, Max. 1A)
• Digital output for operation, error status (AC 250V, Max. 1A) • Output error status (AC 250V, Max. 1A)
Advantage Description
• Water flow consumption reduction • Low ambient kit supports -25° C cooling operation by making stable
SOLUTIONS
CONTROL
• Pump electricity consumption reduction condensing pressure with reducing air flow rate from hood and
• Including IO Module (Dry contact input, Analog input / output, Digital output) damper control given 0 ~ 10V proportional to condensing pressure.
: Using Dry contact and variable water flow control function simultaneously • Low ambient kit provides IO Module function. Front Back
• External snow hood and air damper are required for this item.
: Field Supply item
• Transformer and terminal block are included.
Wiring Diagram
Cooling Tower
Models Applied
• MULTI V 5
Single Line • MULTI V IV
Cooling Tower
Flow
control
valve Pump / Cooling Tower
Controller
Installation Scene Reference : Air Damper
Main PCB
Flow
control
valve Pressure
sensor Damper Actuator
(0 ~ 10V)
Transformer
AC 220V
-> AC 220V
From Water Source
Inverter pump
MULTI V 5 IO Module
• Flow control valve : Regulates the flow or pressure of a fluid, normally responding to signals generated by independent devices. DC 0 ~ 10V
• Flow Meter : Measures mass flow rate of a fluid traveling through a tube. (The mass flow rate is the mass of the fluid traveling past a fixed point per unit time.) Common
• Pressure Sensor : Measures the pressure.
Control AC 24V
Note : The IO Module can control maximum three actuators. Please, review damper actuator’s installation manual.
196 197
Cooling Tower
INTEGRATION DEVICE
PRDSBM COMMUNICATION KIT CONTROL KIT EEV KIT TXV Kit (Thermal Expansion Valve)
PAHCMR000 PAHCMS000 PRCKD21E PRLK048A0 PATX13A0E / PATX20A0E
Features PRCKD41E PRLK096A0 PATX25A0E / PATX35A0E
• Indoor unit mode control without central controller PATX50A0E
• Select operation mode : Cooling, Heating, Fan mode
• Mode lock for cooling & heating mixing error-proof during the change of season Specifications
Fan Mode Mode Change Communication & Control Kit
Combination Dimensions (mm)
Type Model Outdoor EEV TXV Centralized Description
Cooling Heating W H D
Unit Kit Kit Controller
only only
MULTI V ○ ○ ○
Return / Room air temperature control by DDC or
PAHCMR000 300 300 155
LG individual / centralized controller
Single Split - - ○
SOLUTIONS
CONTROL
Communication
kit
MULTI V ○ ○ ○
Discharge air temperature control by DDC or
PAHCMS000 380 300 155
LG individual / centralized controller
Single Split - - ○
PRCKD21E MULTI V - ○ ○ Max. capacity 1 ~ 4 master outdoor unit 600 750 285
Control kit
PRCKD41E MULTI V - ○ ○ Max. capacity 5 ~ 8 master outdoor unit 600 750 285
Models Applied
Expansion Valves
• MULTI V 5 • MULTI V WATER II • MULTI V WATER IV
Pipe Diameter (mm) Dimensions (mm)
• MULTI V IV • MULTI V S Type Model Capacity Range Liquid Liquid Gas Gas
• MULTI V WATER S • MUL TI V PLUS II, MULTI V PLUS (ODU) (ODU) (AHU) W H D
(AHU)
EEV Kit PRLK048A0 1.3 ~ 10 HP 12.7 12.7 - - 217 404 83
(Electronic
Expansion Valve) PRLK096A0 12 ~ 20HP 12.7 12.7 - - 217 404 83
198 199
INTEGRATION DEVICE
AHU KITS
Communication Kit Communication Kit Application
HIGH ENERGY EFFICIENCY Small Capacity with Single Split + Return / Room Air Temperature Control
LG’s DX AHU solutions are capable of performing
all indoor air conditioning tasks with success under Temp. Sensors
all operating conditions thanks to their superior Comm. Line
Central Comm. Line to ODU
performance with high efficiency heat source system. Ref. Pipe
AHU MULTI V 5
TE = Evaporator Temperature
Solution benefits offer the following advantages: (Liquid Pipe / Gas Pipe)
• High energy efficiency inverter system TR = Return Air Temperature
TROOM = Room Air Temperature
• Large range of expansion valves Control Option
TE
: 1.3 ~ 20 HP EEV Kit, 8 ~ 56 HP TXV Kit
• Connected to various heat sources MULTI V WATER IV MULTI V S SINGLE SPLIT
SINGLE SPLIT
Centralized Controller 1)
: MULTI V, MULTI V WATER, MULTI V S, SINGLE SPLIT
AHU DX Coil
TR
OR / AND
DIVERSE OPTIONS FOR CONTROL
AHU communication kit can be connected to various LG Controller DDC by Contact signal DDC by Modbus ROOM
control system such as LG individual/central controller
and DDC 1). It can be directly connected to DDC
without separated controller, so DDC can receive TROOM PAHCMR000
SOLUTIONS
DDC
CONTROL
Central Individual (Modbus or Contact signal)
product control and monitor information through Controller Controller DDC DDC
contact signal or Modbus protocol.
AI / DI / DO
signal
• LG Individual/Central controller supported
- LG controller stand alone or combination with DDC Small Capacity with Single Split + Discharge Air Temperature Control
• Direct wiring between DDC and AHU communication kit
- Embedded Digital I/O and Analog Input Temp. Sensors
- Modbus RTU protocol supported AHU Kit AHU Kit AHU Kit Comm. Line
Central Comm. Line to ODU
1) DDC : Direct Digital Controller
Ref. Pipe
TE = Evaporator Temperature
(Liquid Pipe / Gas Pipe)
TD = Discharge Air Temperature
TROOM = Room Air Temperature
TROOM PAHCMS000
DDC
(Modbus or Contact signal 2))
200 201
INTEGRATION DEVICE
AHU KITS
Communication Kit Application Communication Kit Application
Small-Medium Capacity with Multi V + EEV Kit + IDU + Return / Room Air Temperature Control Large Capacity with Multi V + TXV Kit + Return / Room Air Temperature Control
TR TR
OR / AND OR / AND
ROOM ROOM
SOLUTIONS
DDC DDC
CONTROL
(Modbus or Contact signal) (Modbus or Contact signal)
Small-Medium Capacity with Multi V + EEV Kit + Discharge Air Temperature Control Large Capacity with Multi V + TXV Kit + Discharge Air Temperature Control
PAHCMR000
OR / AND OR / AND
ROOM ROOM
1) Multiple EEV kits can be applicable with multiple DX Coils and PAHCMR000s 1) TXV Kit should be connected with outdoor unit 1:1
2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC 2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC
Note : For more detail, please refer to the PDB Note : For more detail, please refer to the PDB
202 203
INTEGRATION DEVICE
AHU KITS
Communication Kit Function Communication Kit Function
Communication with DDC via Contact Signal With LG Control system (Individual & Centralized Controller)
Function List PAHCMR000 PAHCMS000 Type Electric Spec. Function List PAHCMR000 PAHCMS000 Note
Comm. Kit Operation On / Off Digital Input Non voltage Comm. Kit Operation On / Off On / Off -
Operation Mode 1) Cooling / Heating Digital Input Non voltage Operation Mode 1) Cooling / Heating Cooling / Heating -
Return (room) Air Temperature 2) 16 ~ 30°C - Analog Input DC 0 ~ 10V / 20mA Return (room) Air Temperature 16~30°C - -
Control Discharge Air Temperature 3) - - - Control* Discharge Air Temperature 2) - 16 ~ 30°C -
Fan Speed 4) - Low / Middle / High Digital Input Non voltage Fan Speed 3) Low / Middle / High - -
Forced Thermal On / Off On / Off - Digital Input Non voltage Forced Thermal On / Off - - -
Capacity Control - ○ Analog Input DC 0 ~ 10V / 20mA Capacity Control - - -
Comm. Kit Operation 2) On / Off Digital Output Max. : DC 12V / 1A, AC 250V / 3A Comm. Kit Operation On / Off On / Off -
Operation Mode - - It needs to be checked through control signal Operation Mode 1) Cooling / Heating Cooling / Heating -
Return (room) Air Temperature - - - By Individual controller : 11 ~ 39.5°C
Return (room) Air Temperature 11~39.5°C / -50~100°C -
By Centralized controller : -50 ~ 100°C
Discharge Air Temperature - - -
Monitor Discharge Air Temperature - -50 ~ 100°C Only with Centralized Controller
Fan Speed 2) Low / Middle / High Digital Output Max. : DC 12V / 1A, AC 250V / 3A Monitor
Fan Speed 3) Low / Middle / High - -
Defrost Operation 2) Defrost / Normal Digital Output Max. : DC 12V / 1A, AC 250V / 3A
Defrost Operation On / Off On / Off Only with Individual Controller
Error Alarm 2) Error / Normal Digital Output Relay C contact (Max. : DC 30V / 5A, AC 250V / 5A)
Error Alarm Error Code Error Code -
Compressor On / Off - On / Off Digital Output Max. : DC 12V / 1A, AC 250V / 3A
Compressor On / Off On / Off On / Off Only with Individual Controller
※ ○ : Applied, - : Not Applied
1) Available operation mode can be varied depending on the setting of Communication Kit ※ ○ : Applied, - : Not Applied
2) This function may not be possible depending on the setting of Communication Kit. For more details, please refer to the product data book 1) Available operation mode can be varied depending on the setting of Communication Kit. For more details, please refer to the product data book
3) Discharge air temperature should be controlled directly through DDC 2) This range may differ depending on the type of controller
4) To control the fan speed using contact signal, DO ports for the status of fan speed needs to be connected with the fan unit 3) To control the fan speed using contact signal, DO ports for the status of fan speed needs to be connected with the fan unit
Note : Control function is unavailable in case of using together with DDC via contact signal
SOLUTIONS
CONTROL
Communication with DDC via Modbus protocol Compatibility with LG HVAC Controllers
Function List PAHCMR000 PAHCMS000 Note BMS
Individual Controller Centralized Controller PDI
Gateway
Comm. Kit Operation On / Off -
AC Premium
Cooling / Heating - Premium Standard III Standard II AC Ez AC Ez Touch AC Smart 5 ACP 5 Manager 5 1) ACP Lonworks Standard
Operation Mode 1)
Return (room) Air Temperature 16 ~ 30°C - - Controller
Control Discharge Air Temperature - 16 ~ 30°C -
Fan Speed 2) Low / Middle / High - -
Forced Thermal On / Off - -
Capacity Control - ○ - PREMTA000
PREMTB100 PQNUD1S40
Comm. Kit Operation On / Off - Model no. PREMTA000A PREMTB001 PQCSZ250S0 PACEZA000 PACS5A000 PACP5A000 PACM5A000 PLNWKB000
PREMTBB10 PPWRDB000
PREMTA000B
Operation Mode 1) Cooling / Heating -
PAHCMR000 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Return (room) Air Temperature -50 ~ 100°C - Corresponding air temperature sensor connected to AHU
comm. kit is required PAHCMS000 - - ○2) - - ○ ○ ○ - -
Discharge Air Temperature - -50 ~ 100°C
Monitor
Fan Speed Low / Middle / High - - ※ ○ : Applied, - : Not Applied
Defrost Operation On / Off - 1) AC Manager 5 is an integrator, so the installation with AC Smart 5 or ACP 5 is required
2) Set temperature range of this model shall be extended in the future
Error Alarm Error Alarm & Code - Note : 1. Dry contact for indoor unit (PDRYCB000 / 400 / 300 / 500) is not applied
Compressor On / Off On / Off - 2. For more details, please refer to the product data book
204 205
INTEGRATION DEVICE
AHU KITS
Communication Kit Function Control Kit
Outdoor Unit Compatibility List Required Item
MULTI V Heating / Cooling SA / RA temperature sensor (or SA / RA temperature & humidity sensor)
Automatic Ventilation SA / RA temperature, CO2 sensor, Damper actuator (OA, EA, MA)
MULTI V MULTI V WATER
Model Energy Saving (Cooling Mode Only) SA temperature, OA / RA temp&humidity sensor, Damper actuator (OA, EA, MA)
5 IV III S IV II S
Humidification SA temperature, RA temperature & humidity sensor, Humidifier
PAHCMR000 ○ ○ ○ ○ ○ ○ ○
AHU Controller Inverter Fan Control SA / RA temperature, Static pressure sensor, Inverter driver for fan control
PAHCMS000 ○ ○ ○ ○ ○ ○ -
Filter Alarm Difference pressure sensor
Smoke Detecting Smoke detection sensor
Single Split
RA : Return Air, EA : Exhaust Air, OA : Outdoor Air, SA : Supply Air, MA : Mix air (RA + OA)
SOLUTIONS
CONTROL
- Power : AC 24V, Output signal : DC 0 ~ 10V
Static Pressure Sensor - Apply to SA (for inverter control)
- Boundary : 0 ~ 1000pa
- Power : AC 24V, Output signal : DC 0 ~ 10V
CO2 Sensor - Apply to RA duct
- Boundary : 0 ~ 2000ppm
Expansion valves for MULTI V system Smoke Detection Sensor - Power : AC 24V, From : Contact point type - Apply to RA duct
PRLK096A0 Note : Boundary of specification can be changed through LGAV software. However, please make a specification referring to the above table
EEV Kit
PRLK048A0
HP 1.3 1.6 2 2.5 3 3.5 4 5 6 8 10 12 14 16 18 20
Cooling (kW) 3.6 4.5 5.6 7.1 8.2 10.6 12.3 14.1 15.8 22.4 28 33.6 39.2 44.8 50.4 56 Various Control with Control kit – Multiple MULTI V + TXV Kits
Heating (kW) 4 5 6.3 8 9.2 11.9 13.8 15.9 18 25.2 31.5 37.8 44.1 50.4 56.7 63
Refrigerant Piping
PATX50A0E
Communication Wire
PATX35A0E Thermistor (Pipe Temp.)
TXV Kit PATX25A0E Signal (On / Off)
Air Handling Unit Expansion Kit
PATX20A0E Signal (DC 0 ~ 10V)
PATX13A0E
HP 8 ~ 16 18 ~ 26 28 ~ 36 38 ~ 46 48 ~ 56
Temperature Sensor
Cooling (kW) 22.4 ~ 44.8 50.4 ~ 72.8 78.4 ~ 100.8 106.4 ~ 128.8 134.4 ~ 156.8 - Return Air, Supply Air (Essential)
- Mixed Air
Heating (kW) 25.2 ~ 50.4 56.7 ~ 81.9 88.2 ~ 112.1 118.4 ~ 143.6 148.5 ~ 175.1
Temp & Humidity Sensor
* Capacities are based on the following conditions : - Return Air / Supply Air / Outdoor Air
- Cooling : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
Condensing temperature (tc) 46°C, Evaporating temperature (te) 6°C
- Heating : Indoor 20°C (68°F) DB / 15°C (59°F) WB Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB Damper Actuator
Hot gas inlet temperature 70°C, Condensing temperature (tc) 46°C - Exhaust Air / Outdoor Air / Mixed Air
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is zero
Differential Pressure Switch
CO2 Sensor
Smoke Detector
Fan
- Supply / Return
206 207
APPLICATION
Reception Atrium
Integrated management of AHU applied
Air conditioner control in conjunction
to large spaces
with check-in or check out AC Smart 5 Comm. Kit
(Schedule)
Public Areas
SOLUTIONS
Chiller and VRF integrated control
CONTROL
Central controller
Centralized management of the public areas (Operation trend) Chiller option kit
The air conditioner Integrated control of Control with existing Guest safety is Air conditioner control Rationally distribute Fast problem detection Reduces energy Integrated Chiller and VRF
automatically turn off air conditioner with the hotel thermostat the first priority in conjunction with and manage power and alarms by checking management of AHU integrated control
when guests leave hotel room controller check-in or check out consumption by the tenant operational trends applied to large spaces
WHM
(Watt-Hour Meter) Chiller option
Error C store
Pulse signal kit (S/W)
Over
24°C Cooling
21°C
ACP 5
Power PDI
100 kWh
Input Function Input • 6000ppm • BMS Integration • Max. 128 IDU • BMS Integration • Return air
• Operation On / Off • Operation • Operation On / Off (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP)
• Indoor temperature • Thermo On / Off
Output • Error alarm • Operation mode
• Operation On / Off status • Set run mode (Fan / Heat / Cool) PACP5A000 PACS5A000
• Error alarm • Set temperature • Fan speed ACP 5 AC Smart 5
• Set fan speed (Low / Middle / High)
208 209
APPLICATION
HOSPITAL EDUCATION
Hospital Control Solution Education Control Solution
Lecture Room
Control fan speed and air volume
Dry contact
Schedule management according to
academic plan Central controller
(Schedule)
Service Zone
Energy savings based on flexible Maintenance Office
scheduling Central controller Integrated management of distributed
(Schedule)
buildings Central controller
(Multiple management)
Lobby
Centralized management of AHU for Centralized management with multiple
interfaces
SOLUTIONS
large spaces Central controller
CONTROL
(HTML5)
Comm. Kit
Proper airflow Monitor the comfort level External device Energy savings based on Centralized management Automatically save Central controls Schedule management Integrated management Centralized management
management for patients for each hospital ward interlock control flexible scheduling of AHU for large space energy in the absence prevent students from according to academic plan of distributed buildings with multiple interfaces
of students arbitrary control
Relay
• 4.3 inch color LCD • BMS Integration • BMS Integration • Discharge air • 4.3 inch color LCD
• Touch button (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button
210 211
APPLICATION
OFFICE RESIDENTIAL
Office Control Solution Residential Control Solution
Maintenance 0ffice
Energy savings and management
throughout the building Central controller
Home
(Energy Navi.)
Control your home air conditioner
anytime, anywhere
Integrated management of HVAC with Wi-Fi Modem
SOLUTIONS
Stable system operation
CONTROL
Independent
Energy savings based on occupancy power module
Energy savings Integrated Reduce costs by Reasonable power Main equipment Energy savings Control your home air Build a Smart house Use a familiar residential Simple interlocking Stable system
and management management of HVAC replacing BMS distribution to tenants 24 hours back up based on occupancy conditioner anytime, thermostat control by remote control operation when indoor
throughout the building with BMS system management detection anywhere unit power is lost
WHM Human
BMS Protocol Pump Lighting Fan Sensor (Watt-Hour Meter) detection
Pulse signal sensor
Power PDI A B
Fan
BMS System 100 kWh
Forecasting
Radiator
PACS5A000 PLNWKB000 PEXPMB000 PPWRDB000 PACS5A000 PTVSMA0 PWFMDD200 PDRYCB500 PDRYCB300 PREMTB100 PRIP0
AC Smart 5 LonWorks gateway ACS IO Module PDI Standard (2 port) AC Smart 5 Human detection sensor LG Wi-Fi modem Modbus RTU (9,600bps) 8 contact point Wired remote controller Independent power module
• BMS Integration • Max. 128 IDU • BMS Integration Function Function Input • 4.3 inch color LCD • EEV full close function
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • On / Off • Operation • Operation On / Off • Touch button
• Fan speed • Indoor temperature • Thermo On / Off
• Operation mode • Error alarm • Operation mode
• Vane control • Set operation mode (Fan / Heat / Cool)
• Reservation • Set temperature • Fan speed
(Sleep, Weekly On / Off) • Set fan speed (Low / Middle / High)
• Error check
PACP5A000 PMBUSB00A PEXPM300 PQNUD1S40 PACP5A000 PREMTB100 Output
ACP 5 Modbus RTU gateway PEXPM200 PDI Premium (8 port) ACP 5 Wired remote controller • Operation On / Off status
PEXPM100 • Error alarm
• BMS Integration • Max. 128 IDU • BMS Integration • 4.3 inch color LCD
ACU IO Module
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button
212 213
ACCESSORIES
ACCESSORIES
214 215
assembly, always put a clean sheet on the floor.
• Always use the screw included in the product. This product is composed of the following components.
(If you use other screws, it can damage the product.)
Ceiling Ceiling
8mm
8mm
Indoor unit Indoor unit 266mm
308mm
TM model TN model
Indoor unit
266mm
TP model
Stylish designed panels make more unique space by various applications. Cover in case of exposed
Thecassette installation.
characteristics of this external cover are as follows.
1. The height of the cover can be adjusted according to the height of the product.
(Refer to top picture)
2. Cover on the piping side can be detached.
• Read the installation manual carefully before installing the cover. Ceiling Ceiling
• Independent vane operation uses separate motors, making it Possible to control all 4 vanes independently. • Specially
• To prevent thedesigned forfrom
exterior of the cover indoor unitor become dirty during the
8mm
being scratched
8mm
266mm
Indoor unit 308mm Indoor unit
assembly, always put a clean sheet on the floor.
• The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain • Covers the side area of cassette
• Always use the screw included in the product. This product is composed of the following components.
(If you use other screws, it can damage the product.) TM model TN model
pipe and refrigerant pipes. • Gives elegant looks
Cassette
Cassette cover
cover
• Light
The purpose installation
installation
weight of this external manual
manual
Ceiling
cover is to prevent the
50mm
• Use this when install the cassette air conditioner on the ceiling without any finishing.
Follow
Follow the the details
details to to install
install the
the external
external cover cover correctly.
correctly. TP model
• Read the installation manual carefully before installing the cover.
Follow the details to install the external cover
• Read the installation manual carefully before installing the cover.
• To prevent the exterior of the cover from being scratched or become dirtycorrectly.
Ceiling
during the
Ceiling
8mm The characteristics of this external cover are as follows.
• To prevent the exterior of the cover from being scratched
8mm or become dirty during the
Compact and Stylish Design • assembly,
assembly,
• Always
• To
always putmanual
Read the installation
usethe
prevent
Always
a clean sheet onbefore
always put a cleancarefully
the screw included
use theexterior
in the
of the cover
screw included
the floor.
product.
from
in the
installing the cover. Indoor unit
sheet on the floor.
being scratched or become dirty during the
product.
308mm 1. The heightIndoor
This
This
of theunit
product
product
(Refer to
266mm
is composed of the following components.
cover can be adjusted according to the height of the product.
top picture)is composed of the following components.
(If you use other screws,
assembly, it can damage the product.)
(If you use always put a clean
other screws, it cansheet
damageon the
thefloor.
product.) TM model 2. Cover onTN themodel
piping side can be detached.
• New 4 way cassette panel adapted unibody shape and matching with into the ceiling • Always use the screw included in the product. This product is composed of the following components.
(If you use other screws, it can damage the product.) Ceiling
• Panel size is fit into the ceiling tile The
The purpose
purpose of of this
this external
external cover cover is to prevent the
50mm is to prevent the
indoor unit
unit from being exposed Included Parts
externally.
ACCESSORIES
indoor
The purpose from
of being
this exposed
external cover externally.
is to prevent Indoor unitthe
266mm
• Use this when install the cassette air conditioner on the ceiling without any finishing.
indoor unit from being exposed externally.
• Use this when install the cassette air conditioner on the ceiling without any finishing.
Specification
Detach function
Detach function
Dimension (mm) Applied Model Capacity (kW)*
Suction Color
Model Gloss Weight Single Split MULTI Split MULTI V Detach function
Type (RAL) (kg) W H D
R32 R410A R32 R410A R410A
PT-QCHW0 Grill Morning Fog (RAL 9001) - 3.0 620 35 620 2.5 ~ 5.0 2.5 ~ 5.0 1.5 ~ 5.3 1.5 ~ 5.3 1.6 ~ 6.2 Specification P/No.:3828A20128R
P/No.:3828A20128R
PT-MCHW0 Grill Morning Fog (RAL 9001) - 6.3 950 35 950 6.8 ~ 14.6 6.8 ~ 14.6 6.7 - 7.1 ~ 15.8
4 Way Weight (kg) P/No.:3828A20128R Dimensions (mm)
PT-UQC Grill Morning Fog (RAL 9001) - 3.0 700 22 700 2.5 ~ 5.0 2.5 ~ 5.0 - 1.5 ~ 5.3 1.6 ~ 6.2 Model Front Panel
NET Gross W H D
PT-UMC1 Grill Morning Fog (RAL 9001) - 5.6 950 25 950 6.8 ~ 14.6 6.8 ~ 14.6 - 6.7 7.1 ~ 15.8
PT-UMC / TP / TN 5.9 8.8 1,157 1,157 268
2 Way PT-USC Grill Morning Fog (RAL 9001) - 4.7 1,100 28 690 - - - - 2.8 ~ 7.1 PTDCM
PT-UMC1 TM 5.9 8.8 1,157 1,157 310
PT-UUC Grill Noble White (RAL 9003) ○ 4.6 1,100 34 500 - - - - 2.2 ~ 3.6
TR 5.0 7.2 907 907 268
PT-UUC1 Grill Noble White (RAL 9003) - 4.4 1,100 34 500 - - 2.6 ~ 3.5 2.6 ~ 3.5 - PTDCQ PT-UQC
TQ 5.0 7.2 907 907 310
1 Way PT-UTC Grill Noble White (RAL 9003) ○ 5.5 1,420 34 500 - - - - 5.6 ~ 7.1
PT-UUD Panel Noble White (RAL 9003) ○ 4.6 1,100 34 500 - - - - 2.2 ~ 3.6
PT-UTD Panel Noble White (RAL 9003) ○ 5.5 1,420 34 500 - - - - 5.6 ~ 7.1
216 217
MECHANICAL ACCESSORIES
LZ-H100GXN0 / LZ-H050GXH0 refrigerant concentration exceeds 6,000ppm. Rated Voltage (V) DC 5.0 5%
Dimensions (W x H x D, mm) 31 x 44 x 20
LZ-H080GXH0 / LZ-H100GXH0 (The green and red LED lights blink simultaneously.) Weight (g) 22
• Alarm is “ON” over 6,000ppm has been maintained 5 Detectable Refrigerant R410A
Sensor
seconds, and Alarm is “OFF” under 6,000ppm has been Detected Concentration (ppm) 0 / 6,000 Alarm Off / On
Key Features maintained 5 seconds.
Operating Temperature Range (oC) -10 ~ 50
Preserved Temperature Range (oC) -40 ~ 60
Specification Dimensions (unit : mm) • When the alarm of the refrigerant leak detector is switched Average Power Consumption (mA) 35
Connecting
• Applied Model : ERV (Embeded), ERV DX (Option) 69 26.4 on the user must ventilate the room until the alarm is Cable Cable Length (m) 10
Sensor Dimensions of Front Plate (W x H x D, mm) 80 x 110 x 44.6
• Supply voltage : DV12V 5% disabled. Protective
Cover Dimension of Backplate (W x H x D, mm) 80 x 110 x 6.5
• Output : 0.6 ~ 4.4V (Linear output, 240 ~ 1,760 ppm CO2) • The detector has to be installed inside the room and it shuld This function available for ARU****L**5 and 4(Multi V 5, Multi V IV H/P, H/R model)
• Accuracy : 10% (2 days after installation)
50
ACCESSORIES
Key Application
CO2 (ppm)
How to Intstall
1. Remove a screw on the service cover. Pull the service cover fixing bracket(①), then remove the service cover(②). Remove two elements(③) and two air filters(④). Room 1 Room 2 Room 1 Room 2 Room 1 Room 2
※ Airflow can be controlled by concentration of CO2, after setting automatic operation mode at remote controller.
※ Use the screwdriver whose total length is less than 250mm. Accessory Specification (To realize the case 2 application)
1 2 3 4 5 6
218 219
MECHANICAL ACCESSORIES
Applied Products
Applied Products
Indoor Unt Model Chassis Applicable
1 Way Cassette TU ○ MULTI V Indoors (Ceiling Concealed Duct, Floor Standing Units)
TT N/A
2 Way Cassette
TS ○(~5.6kW)
Cassette TR ○
TQ ○(~4.5kW)
Key Features 4 Way Cassette TP
TN
N/A
N/A
Key Features
TM -
• Decreasing noise level of Multi V Indoor units and easy BG - • Designed for wireless control
High Sensible BR -
installation B8 -
• Indication lamps (3 colors) and Self-diagnosis function
High Static B8 -
Duct M1 ○(~5.6kW)
Middle Static M2 -
M3 -
Low Static
L1
L2
○
-
Key Application
L3 -
Floor Standing
CE ○ Note : Do not install both the IR Receiver and Wired Remote Controller. This may cause malfunctions.
CF -
Convertible VE ○
V1 -
Ceiling Suspended
V2 -
SJ ○
Etc Wall Mounted SK ○
SV -
Art Cool SF ○
Console QA ○
K2 -
HYDRO KIT
K3 -
Key Application ※ ○ : Applied, - : Not applied, N/A : Not Applicable Wired Remote
Controller IR Receiver
EEV Kit can be applied for the space which requires qutie
ACCESSORIES
Pipe
Wire and nosie-sensitive
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
Outdoor Unit Wireless Remote
Controller
(Standard)
C / Box EEV
Kit
Luxury Hotel Villa
Indoor Unit Operation of Indication Lamps Test Run Mode
① Emergency Operation button : After installing the product, you must run a
Turns the indoor unit on or off when Test Run mode. Press the Emergency Operation
Indoor Unit EEV Kit Outdoor Unit remote controller is not working. button for 5 seconds, until the LED flickers. Then
Indoor Heat Exchanger
Electronic ② Signal Detector : the indoor unit, duct runs cooling mode for 18
Expansion Valve minutes, where the setting temperature is 18℃
Fan M Receives the signal from remote controler.
③ Timer lamp (Green) : and the fan speed is high.
COMP
M Fan Heat Exchanger
Executive office Meeting room Lights up during the timer operation.
Note : If you don’t use EEV of same specification, Cooling (Heating) capacity could be decreased. ④ Hotstart lamp (Orange) :
Lights up during the pre-heating operation,
defrost operation as well as latent heat
6 5 removal operation in heat mode. Available
4 3 only for the heat pump models, not cooling
only models.
How to Install 2 1
⑤ System On/Off lamp (Red) :
Lights up during system controller
Open Indoor unit’s control box cover. Signal Receiver operation.
① Open fully indoor unit’s EEV through vacuum mode of ODU setting. Indoor Unit ⑥ Filter Sign lamp (Green) :
② Detach the Indoor unit’s EEV connector from PCB and then push the reset C/Box Lights up after 2,400 hours from the time
button of Outdoor unit’s PCB
of first power on operation.
③ After connecting indoor unit’s EEV CONNECTOR, repeat the process Existing
① & ②. Then, connect the EEV CONNECTOR of EEV KIT in PCB of indoor unit. EEV
④ Finally connect the lead wire of the EEV Kit to the indoor unit’s PCB. KIT
EEV
⑤ Assemble the control box cover.
CN-EEV
220 221
MECHANICAL ACCESSORIES
2. Included Items
ENGLISH
ENGLISH
ENGLISH
• Harness 1 (1m)
Item
Independent
Screw
Clamp
• Harness 2 (1m)
into compressor which could damage the compressor in cooling Model ModelModel Model PRARH1 PRARH1
PRARH1
PRARH1 3 rdParty Scope
3 rd
Party Scope
(Tie Wrap)
ENGLISH
Power Kit mode. Also condensing might happened for unclosed EEV’s
• Harness 3 (1m) PRARH1
Item Auxliary
Item Heater
Item Auxliary Relay
Auxliary
Model
Heater
Item KitRelay
Heater Kit Screw
Relay
Auxliary Kit ScrewScrew
Heater Insulation
Screw Installation
Insulation
Insulation
Insulation Manual
Installation
Installation
Installation ManualManual
Q,ty 1 2 4 • Installation Manual Indoor unit due to flow of refrigerant. Q’ty Q ’ t y 1 Item 1
Relay Kit
Auxliary Heater 2
Relay Kit 2 2
Screw 2
Insulation
Manual
1Installation 1
• Insulation (PE) Q’ty 1 2 2 1 Manual RADIATOR
RADIATOR
Q’ty
Q'ty 11 2 2 2 2 1 1
IncludedIncluded Items Items
ItemsIncluded
Electricity Cut-off EEV Valve
Hot Water
2. Included Items
Close Hot Water
2. Included
2. Included
Figure FigureFigure
Items Items
Figure
Figure Included Items
Figure
ENGLISH
External Power supply
ENGLISH
ACCESSORIES
ENGLISH
2. Included Items
- Supply voltage : AC 24V
M4 x10
• PRARH1 applies to High Static Duct, Low Static Duct, 1Way CST, 2Way CST, 4Way CST and Ceiling
PRARS1 PRARS1
ENGLISH
Model ModelModel Suspended types.
Model PRARS1 PRARS1 LG Scope
LG Scope
• PRARH1 applies
• PRARH1 to
• PRARH1 Highapplies
applies Static
to High Duct,
to HighLow
Static Static
Static
Duct, LowDuct,
Duct, Low1Way
Static Duct,CST,
Static 2Way
Duct,
1Way CST,CST,
1Way CST,
2Way4WayCST,CST
2Way CST,
4Wayand Ceiling
4Way
CST CSTCeiling
and and Ceiling
Item
Item Suspended
Suspended Item
Auxliary
types. Auxliary
SuspendedHeater
types. Heater
Auxliary
Relay Kit
Model
types.
Item Relay
Heater Kit
Relay
Auxliary Kit
Heater
Screw Screw PRARS1
Screw Insulation
Insulation
Screw Installation
Installation
Insulation
Installation
Insulation Manual Manual
Installation Manual Indoor Unit
Indoor Unit
(Unit : inch)
(Unit : (Unit
inch) : inch)
CN_PTC
DC12V
DC12V
A
2-19/32
B
CN_PTC1
A
DUCT / FS / CVT / FAU CST / Console / Hydro Kit Gen2 Wall Mounted / ARTCOOL Gen4 Wall Mounted ① Turn the power off using circuit breaker.
B
② Disconnect the EEV cable of the indoor unitʼs PCB
CN_WRITE or CN1
CN_WRITE or CN1
2-19/32
2-19/32
③ Connect the independent power module (CN-EEV/
2-19/32
• PRARS1
• PRARS1 applies applies
• PRARS1
to to Walltomounted
Wallapplies
mounted WallArt
and and Art
mounted
cool cool
and
types. Arttypes.
cool types. 7-9/32
CN_EEV
CN_EEV CN_EEV LOAD) to the indoor unitʼs EEV, using harness 1.
How to Install (Unit : inch)
CN_WRITE or CN1
3-13/32
7-9/32 14 Auxiliary Heater Relay Kit
7-9/32 7-9/32
2-19/32
CN_EEV / LOAD
2-7/32
CN_EEV / LOAD
CN_EEV / LOAD CN_EEV / LOAD
2 3/16
Harness 1 1-13/32 1-13/321-13/32 6-23/32 6-23/326-23/32
1-7/16
Harness 1 Harness 1 Harness 1
* FS : Floor Standing Aux heater
Aux heater communication
* CVT : Convertible communication lines Aux heater communication lines lines
To Indoor unit’s EEV
* FAU : Fresh Air Intake Unit
2 3/16
To Indoor unit’s EEV
2 3/16
To Indoor unit’s EEV To Indoor unit’s EEV
* CST : Cassette 2 3/16
High Static Ducted 7 Low
9/32 Static Ducted Ceiling Suspended Wall Mounted
1 13/32 6 23/32
3-13/32
3-13/32
3-13/32
2-19/32
2-19/32
2-19/32
2-7/32
2-7/32
2-7/32
Aux heater Installation Manual 5
1-7/16
1-7/16
1-7/16
communication
lines
7 9/32 7 9/32
3 13/32
7 9/32
3 13/32
3 13/32
2 7/32
Installation
2 7/32
Installation Manual 5
1 7/16
1 7/16
1 7/16
Installation Manual 5
222 223
PIPING ACCESSORIES
Applied Products
MULTI V 5
MULTI V IV
MULTI V WATER IV
ACCESSORIES
High Pressure mm (inch) 19.05 (3/4) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50
Power Supply Ø / V / Hz
Considering the direction for Indoor 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60
64 kBtu / Port units and SVC port, connection for
reverse direction makes much easier
dB(A)
46 dB(A) Indoor Unit Reducer
13dB
33 dB(A)
PRHR023
HR Unit Reducer
Conventional New
224 225
PIPING ACCESSORIES
ARBL057
(7 Branch)
Key Application
Heat Pump System
ARBL104
(4 Branch)
ACCESSORIES
Y Branch for Header for
Indoor Units (2 Pipes) Indoor Units (2 Pipes)
ARBL107
(7 Branch)
Y Branch for Heat Pump
Outdoor Units (2 Pipes)
Y Branch for
Heat Recovery Units (3 Pipes)
HR Unit
ARBL2010
Y Branch for Heat Recovery (10 Branch)
Outdoor Units (3 Pipes)
Y Branch for
Zoning Control (2 Pipes)
HR Unit
226 227
PIPING ACCESSORIES
PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units.
Specification Specification
Heat Pump Heat Recovery
R410A MULTI V 5, MULTI V IV, MULTI V III, MULTI V WATER IV, MULTI V WATER II R410A MULTI V 5, MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm) (Unit : mm)
LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Gas Pipe
O.D. 22.2 I.D. 19.05
LiquidI.D.Pipe
O.D.15.88 19.05 Low Pressure GasPressure
High
I.D.22.2 O.D. 28.58 I.D.34.9
Pipe Gas Pipe
O.D. 22.2 I.D. 19.05
LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Low
I.D.22.2O.D.
O.D.22.2
Gas
Pressure Pipe Gas Pipe
28.58I.D.I.D.34.9
19.05
LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Low
Gas
O.D. 22.2O.D.I.D.
I.D.22.2
Pressure
Pipe
19.05I.D.34.9
28.58
Gas Pipe
331
314 416
331
314
Low
416 Pressure Gas Pipe
416
Liquid 331 Pipe
314
High Pressure Low 416 Gas
416
Pressure Pipe Gas Pipe Liquid
331 Pipe
314
High Pressure Low
416
Gas
416 Pressure
Pipe Gas Pipe
I.D.15.88 I.D.15.88 I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 I.D.15
408 408 408 408
I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58
I.D.28.58 I.D.28.58 I.D.22.2 O.D. 28.58 I.D.34.9 I.D.28.58 I.D.28.58O.D.15.88 I.D. 19.05 I.D.28.58
I.D.22.2O.D.
O.D.22.2 I.D.28.58
28.58I.D.I.D.34.9
19.05 O.D.15.88 I.D. 19.05 I.D.28.58 I.D.22.2
O.D. 22.2O.D.I.D. I.D.28.58
19.05
28.58 I.D.34.9
O.D.15.88 I.D. 19.05 O.D. 22.2 I.D. 19.05 O.D.15.88 I.D. 19.05 O.D. 22.2 I.D. 19.05 331 331
D.19.05 I.D.12.7 I.D.9.52 83 I.D.19.05 I.D.12.7 I.D.9.52 83 416 I.D.19.05 O.D.15.88 314I.D. I.D.12.7
19.05 I.D.9.52 83 416 I.D.19.05 O.D.15.88 314I.D. I.D.12.7
19.05 I.D.9.52 83 416 I.D.19.05
331 111 331 I.D.22.2 O.D. 28.58 I.D.34.9
I.D.22.2 111
111 I.D.22.2O.D.
O.D.22.2
28.58I.D.I.D.34.9
416 19.05
I.D.22.2 111
111
O.D. 416
22.2O.D.
I.D.22.2 I.D. 19.05I.D.34.9
28.58 I.D.22.2111 111
Liquid Pipe High Pressure Gas Pipe Liquid Pipe
408
High Pressure Gas Pipe
ARCNN21 I.D.22.2 I.D.22.2 408 I.D.22.2 408 I.D.22.2
314 I.D.31.8 I.D.34.9 416 314 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 416
I.D.15.88 331 ARCNB21 I.D.15.88 I.D.31.8 I.D.34.9 408
I.D.31.8 I.D.34.9 416
I.D.15.88 331 I.D.15.88 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 408 I.D.15
I.D.28.58 416 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 416 I.D.28.58 I.D.28.58
I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 314 I.D.28.58 416 I.D.28.58 314 I.D.28.58 416
I.D.22.2 O.D.19.05 I.D.22.2 O.D.19.05 408 I.D.22.2 O.D.19.05
I.D.15.88 I.D.15.88 408 I.D.22.2 O.D.19.05
I.D.15.88 I.D.15.88 408 I.D.22
I.D.15
I.D.12.7 I.D.15.88 I.D.28.58 I.D.28.58 I.D.12.7 I.D.15.88I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.28.58 I.D.12.7 I.D.15.88 I.D.41.3 408
I.D.38.1 O.D.34.9 I.D.12.7 I.D.15.88 I.D.41.3 408 O.D.34.9
I.D.38.1
I.D.28.58 I.D.28.58 I.D.19.05 I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.28.58 I.D.19.05 I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.28.58 I.D.19.05
I.D.28.58 111 I.D.28.58 I.D.28.58
I.D.28.58 111 I.D.28.58 I.D.28.58 I.D.28.58 111
I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.12.7 I.D.9.52 83 I.D.22.2 I.D.28.58 I.D.22.2
I.D.28.58 111 I.D.22.2111
I.D.28.58
D.19.05 I.D.19.05 I.D.22.2 I.D.22.2
O.D.12.7 I.D.9.52 O.D.12.7 I.D.31.8
I.D.9.52 I.D.34.9 O.D.12.7
I.D.12.7 I.D.9.52 I.D.9.5283 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 O.D.12.7
I.D.12.7 I.D.9.5283
I.D.9.52
I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9
70 I.D.22.2 111 70 I.D.19.05
I.D.22.2 70 111 I.D.19.05 70 I.D.19.05
130 I.D.22.2 111 130 I.D.22.2 111 130 I.D.22.2111 111
O.D.15.88 I.D. 19.05 I.D.31.8 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.31.8 I.D.34.9 I.D.22.2 O.D.19.05 I.D.22.2 111 I.D.22.2 O.D.19.05 I.D.22.2 I.D.22
I.D.31.8
I.D.41.3 I.D.34.9
I.D.38.1 O.D.34.9 I.D.31.8
I.D.41.3 I.D.34.9
I.D.38.1 O.D.34.9 I.D.31.8 I.D.34.9
I.D.22.2 O.D.19.05
O.D. 22.2 I.D. 19.05
I.D.22.2 O.D.19.05
O.D. 22.2 I.D. 19.05 I.D.12.7 I.D.15.88 I.D.31.8 I.D.34.9 I.D.12.7 I.D.15.88 I.D.31.8 I.D.41.3
I.D.34.9I.D.38.1 O.D.34.9
331 I.D.12.7 I.D.15.88 O.D.28.58 I.D. 19.05 331 I.D.12.7 I.D.15.88 I.D.28.58 O.D.28.58 I.D. 19.05
I.D.22.2 O.D.19.05 O.D.28.58 I.D. 19.05I.D.28.58 I.D.22.2 O.D.19.05 O.D.28.58 I.D. 19.05 I.D.28.58 I.D.22
I.D.28.58 I.D.28.58
314 I.D.22.2
416 314 I.D.41.3 I.D.38.1 O.D.34.9 I.D.22.2
416 I.D.12.7 I.D.9.52
O.D.12.7 I.D.15.88 I.D.22.2
I.D.41.3 I.D.38.1 O.D.34.9 I.D.9.52
O.D.12.7 I.D.15.88
I.D.12.7 I.D.22.2
I.D.41.3 I.D.38.1 O.D.34.9
O.D.15.88
I.D.15.88 I.D. 19.05
I.D.15.88 I.D.9.52 I.D.28.58 I.D.15.88O.D.15.88 I.D. 19.05
I.D.15.88 I.D.9.52 I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58
O.D.15.88
70 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88
70 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
O.D.12.7 408 O.D.12.7 130 I.D.28.58 408 130 I.D.28.58 130 I.D.28.58
I.D.28.58 I.D.28.58
70 I.D.28.58 I.D.28.58 70 I.D.28.58 I.D.28.58 O.D.12.7 I.D.9.52 O.D.12.7 I.D.9.52
70 O.D.28.58 I.D. 19.05 70 O.D.28.58 130 I.D. 19.05
D.19.05 I.D.12.7 I.D.9.52 83 I.D.19.05 I.D.12.7 I.D.9.52 83 130 130
O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05 I.D.22.2 I.D.22.2
I.D.22.2 111 I.D.22.2 O.D.28.58 I.D.34.9 I.D.22.2 111
O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.31.8 I.D.34.9 I.D.22.2 I.D.31.8 I.D.34.9 I.D.22.2 O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05
O.D.15.88 I.D. 19.05 3 Outdoor Units O.D.15.88 I.D. 19.05 I.D.22.2 3 Outdoor Units I.D.22.2
I.D.22.2 O.D.19.05 I.D.22.2 O.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9
I.D.22.2 O.D.28.58 I.D.34.9 O.D.34.9 I.D.28.58 I.D.22.2 O.D.28.58 I.D.34.9 O.D.34.9 I.D.28.58 O.D.34.9 I.D.28.58
.D.19.05 I.D.12.7 Model I.D.22.2
O.D.19.05 High Pressure Gas PipeI.D.28.58
O.D.19.05 Liquid Pipe
I.D.12.7 O.D.19.05 I.D.22.2 I.D.28.58
Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe
I.D.15.88 416 I.D.15.88 416 I.D.22.2 O.D.28.58 I.D.34.9 I.D.22.2 O.D.28.58 I.D.34.9
O.D.12.7 I.D.9.52 O.D.12.7 I.D.9.52
70 408 70 408 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05
334 334 125I.D.28.58 I.D.15.88 416 125 I.D.15.88 416 125 I
I.D.28.58 I.D.28.58 I.D.41.3 O.D.34.9 I.D.28.58 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9
281 281 341 341
408 408 341
O.D.34.9 I.D.28.58298 334 O.D.34.9 I.D.28.58
298 334 O.D.34.9 I.D.28.58
298 I.D.28.58
O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05 I.D.28.58 I.D.28.58 I.D.28.58
I.D.22.2 I.D.22.2
O.D.28.58 I.D.34.9 I.D.41.3 O.D.34.9 I.D.22.2 O.D.28.58
I.D.22.2 I.D.34.9 281 I.D.22.2 O.D.28.58 I.D.41.3 O.D.34.9
I.D.34.9 281 I.D.22.2 O.D.28.58 I.D.34.9 I.D.41.3 O.D.34.9
.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.22.2 111 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.22.2
O.D.19.05 111 I.D.12.7 O.D.19.05 I.D.12.7 O.D.19.05
O.D.15.88
I.D.15.88 I.D. 19.05 O.D.15.88
I.D.15.88 I.D. 19.05 O.D.34.9 I.D.28.58 O.D.19.05 I.D.22.2 O.D.34.9 I.D.28.58 O.D.19.05 I.D.22.2 O.D.34.9 I.D.28.58
I.D.31.8 I.D.34.9 416 I.D.31.8
125 I.D.34.9 416 I.D.15.88 416 125 I.D.15.88 416 125 I
ACCESSORIES
408 408 I.D.22.2 408
O.D.28.58 I.D.34.9
I.D.22.2 111 I.D.22.2 408O.D.28.58 I.D.34.9
I.D.22.2 111
334 I.D.19.05 83 I.D.41.3 334 I.D.19.05 83 341 341 341
.22.2 I.D.19.05 I.D.28.58I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.19.05
I.D.41.3 298 I.D.34.9
I.D.41.3
I.D.28.58 I.D.38.1 O.D.34.9O.D.19.05
I.D.28.58 I.D.12.7
334 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9
I.D.28.58
I.D.41.3 298 I.D.28.58
I.D.34.9
O.D.19.05 I.D.12.7
334 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9
I.D.28.58
I.D.41.3 298 I.D.28.58I.D.34.9
O.D.19.05
281 281 125 111 I.D.15.88 416 125 111 I.D.15.88 416 125 111 I
I.D.22.2 I.D.19.05 281 I.D.19.05 83 I.D.41.3 I.D.38.1 408
O.D.34.9 I.D.22.2 I.D.19.05 281 I.D.19.05 83 I.D.41.3 I.D.38.1 408 O.D.34.9 I.D.22.2 I.D.1
I.D.28.58 341 I.D.28.58 341 341
298 334 I.D.28.58 298 I.D.28.58 334 I.D.28.58 298 I.D.28.58
I.D.22.2 111 I.D.22.2 111 281 I.D.28.58 111 281 I.D.28.58 111
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130 I.D.22.2 I.D.22.2
I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9
I.D.28.58 O.D.22.2 ARCNN31
I.D.19.05 83 I.D.28.58 O.D.22.2 I.D.41.383
I.D.19.05I.D.53.98
I.D.28.58 111
I.D.34.9 ARCNB31
I.D.15.88 I.D.12.783 I.D.41.3 130 I.D.28.58 111
I.D.34.9 I.D.15.88 I.D.12.783 I.D.41.3130 I.D.28.58 111
I.D.34.9
.22.2 I.D.19.05 I.D.41.3 I.D.22.2 I.D. 34.9 O.D.28.58
I.D.38.1 O.D.34.9
O.D.28.58 I.D.34.9I.D.22.2 I.D.22.2 I.D.19.05 I.D. 44.5 O.D.41.3 I.D.41.3 I.D.22.2 I.D. 34.9
I.D.38.1 O.D.34.9
O.D.28.58 O.D.28.58
I.D.22.2 I.D.34.9 I.D.22.2
I.D.19.05 I.D.19.05 I.D.53.98 I.D. 44.5
I.D.41.3 I.D.38.1 O.D.41.3 I.D.22.2
O.D.34.9 111 I.D.22.2 I.D.19.05 I.D.19.05 I.D.53.98
I.D.41.3 I.D.38.1 I.D. 44.5 O.D.41.3
O.D.34.9 I.D.22.2 111 I.D.22.2 I.D.1
.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9
I.D.15.88 416 I.D.15.88 I.D.41.3 I.D.34.9 416 I.D.28.58 O.D.22.2 I.D.41.3 I.D. 34.9 O.D.28.58
I.D.34.9 I.D.22.2 I.D.28.58 O.D.22.2 I.D.41.3 I.D. 34.9 O.D.28.58I.D.34.9
I.D.22.2 111 I.D.28.58
O.D.15.88 I.D.19.05 I.D.28.58 O.D.15.88 I.D.19.05 111 I.D.28.58 111
408 408 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.1
334 I.D.53.98 I.D.44.5 O.D.41.3
I.D.28.58 I.D.28.58 334 I.D.53.98
I.D.28.58I.D.44.5 O.D.41.3 I.D.28.58
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58 130 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58
281 281 I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130
I.D.53.98 I.D. 44.5 O.D.41.3 I.D.53.98I.D.44.5
I.D.53.98 I.D. 44.5 O.D.41.3
O.D.41.3 I.D.28.58 I.D.53.98 I.D.53.98
I.D.44.5 I.D. 44.5 O.D.41.3I.D.28.58
O.D.41.3
I.D.28.58 O.D.22.2 I.D. 34.9 O.D.28.58 I.D.22.2 I.D.28.58 O.D.22.2 I.D. 34.9 O.D.28.58
I.D.28.58 I.D.22.2
O.D.22.2 I.D.28.58 O.D.22.2 I.D.28.58
111 I.D.28.58 111 I.D.15.88 I.D.12.7 I.D.28.58
130 I.D. 34.9 O.D.28.58 I.D.22.2 I.D.15.88 I.D.12.7 I.D.28.58
130 I.D. 34.9 O.D.28.58 I.D.22.2
I.D.22.2 I.D.53.98 I.D. 44.5 O.D.41.3 I.D.22.2 I.D.53.98 I.D. 44.5 O.D.41.3 I.D.53.98 I.D. 44.5 O.D.41.3
O.D.15.88 I.D.19.05 I.D.31.8 I.D.34.9 O.D.15.88 I.D.19.05 I.D.31.8 I.D.34.9
I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58 O.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58
I.D. 34.9 O.D.28.58 I.D.34.9
I.D.22.2 I.D.28.58 O.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2
I.D. 34.9 O.D.28.58
O.D.28.58 I.D.22.2I.D.34.9 I.D.28.58
.22.2 I.D.19.05 I.D.19.05 83 I.D.53.98 I.D.44.5
I.D.38.1 O.D.41.3
I.D.41.3O.D.34.9 O.D.34.9 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.53.98 I.D.44.5
I.D.38.1 O.D.41.3
I.D.41.3O.D.34.9 O.D.34.9
O.D.19.05 I.D.22.2 I.D.28.58 I.D.41.3 I.D.44.5 O.D.19.05 I.D.22.2 I.D.28.58 I.D.41.3 I.D.44.5 I.D.53.98 I.D.44.5 O.D.41.3 I.D.53.98 I.D.44.5 O.D.41.3
I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
334 341 I.D.28.58 334 341 I.D.28.58
I.D.53.98 I.D.44.5 O.D.41.3 I.D.53.98 I.D.44.5 O.D.41.3
281 298 281 298
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130
I.D.28.58 O.D.22.2 I.D.28.58 O.D.22.2
O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9 I.D. 34.9 O.D.28.58
I.D.41.3 I.D.44.5I.D.22.2
4 Outdoor Units O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9 I.D. 34.9 O.D.28.58
I.D.41.3 I.D.44.5I.D.22.2 4 Outdoor Units
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
334O.D.15.88 I.D.19.05 I.D.41.3 341 I.D.34.9 111 334O.D.15.88 I.D.19.05 I.D.41.3 341 I.D.34.9 111
281 Model High
I.D.53.98 Pressure
I.D.44.5 298
O.D.41.3 Gas Pipe Liquid
281 Pipe O.D.41.3 I.D.44.5 I.D.53.98 298
I.D.53.98 I.D.44.5 O.D.41.3 O.D.19.05 I.D.22.2 Model
I.D.28.58 High Pressure
O.D.41.3
O.D.34.9 I.D.41.3Gas
I.D.44.5 Pipe
I.D.53.98
I.D.44.5 Liquid
O.D.19.05 Pipe I.D.28.58
I.D.22.2 Low Pressure
O.D.41.3
O.D.34.9 Gas
I.D.44.5I.D.44.5
I.D.41.3 Pipe
I.D.53.98 O
415 334 415
341 334 341 415
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.31.8 I.D.28.58 O.D.22.2 I.D.31.8 I.D.28.58 O.D.22.2 375 281 375
298 281 298 375
I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
O.D.41.3 I.D.44.5 I.D.53.98I.D.41.3 O.D.19.05
I.D.41.3 I.D.34.9 111 I.D.34.9 111 I.D.22.2 I.D.28.58 O.D.41.3
O.D.34.9 I.D.44.5
I.D.41.3 I.D.53.98
I.D.44.5 O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9
O.D.41.3
I.D.41.3
I.D.44.5I.D.44.5
I.D.53.98 O
415 334 415
341 341 415
O.D.19.05 I.D.22.2 I.D.28.58
O.D.15.88 I.D.19.05 O.D.34.9
I.D.34.9 I.D.41.3
O.D.28.58 I.D.44.5
I.D.22.2 O.D.19.05 I.D.22.2 I.D.28.58
O.D.15.88 I.D.19.05 O.D.41.3 I.D.44.5 I.D.53.98 O.D.34.9 I.D.41.3
134 I.D.34.9 O.D.28.58
I.D.44.5
I.D.22.2I.D.22.2
O.D.19.05
I.D.19.05 I.D.22.2 I.D.28.58
I.D.19.05 83 O.D.34.9 I.D.44.5
O.D.41.3 I.D.41.3 I.D.53.98
I.D.44.5 134 O.D.19.05 334
I.D.22.2 I.D.19.05 I.D.22.2 I.D.28.58
I.D.19.05 83 O.D.41.3
O.D.34.9 I.D.44.5I.D.44.5
I.D.41.3 I.D.53.98 134 O
I.D.22.2 I.D.
I.D.44.48 I.D.53.98 375 I.D.41.3 281 I.D.44.48 375
I.D.41.3 I.D.53.98298 I.D.41.3
I.D.34.9 111 281 298
I.D.41.3I.D.44.48 I.D.53.98 375 I.D.34.9 I.D.41.3
111
334 I.D.15.88 I.D.12.7 341 334 I.D.15.88 I.D.12.7 415 341 415
341 341 415
I.D.31.8 I.D.28.58 281
O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.31.8 I.D.28.58 281
O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 334 334
298 I.D.28.58 375 298 I.D.28.58 375
298 298 375
281 281
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.22.2 I.D.28.58 O.D.22.2 I.D.19.05
I.D.31.8I.D.19.05 83 I.D.22.2
I.D.31.8I.D.19.05
I.D.28.58 O.D.22.2 I.D.19.05 83 I.D.22.2
I.D.31.8I.D.I
I.D.44.48 I.D.53.98 I.D.28.58 134
I.D.41.3 I.D.53.98
I.D.41.3 I.D.44.5
I.D.44.48 I.D.53.98O.D.41.3 I.D.28.58134
I.D.28.58
I.D.41.3
I.D.34.9 111 I.D.53.98 I.D.44.5I.D.53.98
I.D.41.3I.D.44.48 O.D.41.3 I.D.28.58
I.D.34.9 I.D.28.58
I.D.41.3111 134
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
ARCNN41 I.D.41.3 I.D.34.9 111 I.D.22.2 I.D.41.3I.D.41.3
O.D.28.58 I.D.34.9 134 I.D.34.9
I.D.22.2 I.D.19.05111 ARCNB41
I.D.19.05 83
I.D.41.3I.D.22.2 I.D.41.3
I.D.34.9
O.D.28.58 I.D.34.9 134 I.D.22.2 I.D.19.05 I.D.19.05 83
I.D.41.3I.D.44.48
I.D.22.2 I.D.34.9
O.D.28.58 I.D.41.3
I.D.34.9 134 I.D.22.2 I.D.
I.D.44.48 I.D.53.98 I.D.44.48 I.D.53.98 111 I.D.53.98 111
O.D.15.88
I.D.15.88I.D.19.05
I.D.12.7 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88
I.D.15.88I.D.19.05
I.D.12.7 I.D.34.9 O.D.28.58 I.D.22.2
I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58
I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58I.D.28.58 I.D.31.8 I
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.31.8I.D.28.58
I.D.28.58 O.D.22.2 I.D.31.8 I.D.28.58 O.D.22.2 I.D.31.8 I
I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58 I.D.53.98I.D.22.2
I.D.44.5 O.D.28.58
O.D.41.3 I.D.34.9
I.D.28.58
I.D.28.58 I.D.53.98 I.D.44.5 O.D.41.3
I.D.22.2 I.D.28.58
O.D.28.58 I.D.28.58
I.D.34.9
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05
I.D.22.2 O.D.28.58 I.D.34.9
O.D.15.88 I.D.19.05
I.D.22.2 O.D.28.58 I.D.34.9
I.D.34.9 O.D.28.58 I.D.22.2 I.D.34.9 O.D.28.58 I.D.22.2
228 229
PIPING ACCESSORIES
PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units.
Specification Specification
Heat Pump, Heat Recovery Zone Control Heat Recovery
R410A MULTI V 5, MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI, R410A MULTI V 5, MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II MULTI V WATER II Heat Recovery
(Unit : mm) (Unit : mm)
Model Gas Pipe Liquid Pipe Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe
I.D15.88 I.D6.35
ARBLN01621
ARBLB01621 I.D6.35 I.D15.88
I.D12.7
I.D25.4
I.D9.52 I.D9.52 I.D6.35 I.D22.2 I.D19.05 I.D15.88 I.D19.05
I.D12.7 I.D12.7
O.D19.05
ARBLN03321 I.D28.58
I.D15.88 I.D12.7
I.D12.7
I.D19.05 I.D25.4
ARBLB03321 I.D12.7 I.D12.7
I.D9.52 I.D6.35
I.D28.58 O.D19.05
I.D25.4 O.D19.05
O.D19.05 I.D12.7 I.D15.88 I.D12.7
I.D 22.2 I.D 22.2 I.D9.52 I.D6.35
I.D19.05
I.D12.7
I.D25.4 O.D19.05
O.D19.05
I.D 22.2 I.D 22.2
ACCESSORIES
I.D28.58 I.D22.2 I.D15.88 I.D12.7 I.D15.88 I.D15.88 I.D12.7
I.D12.7 I.D12.7
I.D12.7 I.D12.7 I.D19.05 I.D31.8
ARBLN07121 I.D31.8 I.D19.05 ARBLB07121
I.D15.88 I.D19.05 I.D19.05 I.D15.88
I.D19.05 I.D15.88 I.D15.88 I.D19.05
O.D12.7 I.D6.35
O.D12.7 I.D6.35
I.D31.8 O.D22.2 I.D9.52 I.D31.8 O.D22.2
I.D9.52
I.D34.9 I.D28.58 O.D19.05 I.D28.58 I.D9.52 I.D9.52
I.D34.9 I.D28.58 O.D19.05 I.D28.58
O.D31.8 I.D22.2 O.D12.7 O.D12.7 O.D31.8 I.D22.2
I.D34.9
I.D34.9 I.D41.3 I.D38.1 I.D28.58
I.D34.9
I.D34.9 I.D41.3 I.D38.1 I.D28.58
I.D28.58
I.D38.1
I.D28.58
ARBLN14521 I.D41.3 O.D34.9
I.D34.9 I.D22.2 I.D38.1
I.D41.3
O.D38.1 I.D38.1
ARBLB14521 I.D41.3 O.D34.9
I.D34.9 I.D22.2
I.D41.3
O.D38.1 I.D38.1
Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe
230 231
PIPING ACCESSORIES
ACCESSORIES
Max. 450
Key Application
Mainfold Ceiling Mounted Cassette Flexible Hose
250 (4 Way, 1 Way) Make a Loop Form
Ceiling Concealed Duct
(with Drain Pump)
Capillary Assembly
(Unit : mm)
Specification
* Fault Detect & Diagnosis
Model Length Quantity
PHDHA05T 500mm 30EA
PHDHA07T 700mm 30EA
PHDHA05B 500mm 5EA
232 233
PIPING ACCESSORIES
STOPPER VALVES
"A"
9.52 : 19.05
3.0m Room 1
Key Features
9.52 : 19.05 Closed State
Pin (Closed) Pin (Open)
• This unit can be applied for the additional indoor unit’s installation 3.0m
• This unit can be applied for each indoor unit’s service In case of installation of stopper valve,
Stopper Valves
9.52 : 15.88In case of installation of additional
flare part should be facing towards indoor unit, SVC valve should be in Room 2
10.0m
additional indoor unit. closed state
6.35 : 12.7
3.0m
PRVT120
Room 4
• In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged. (Room 3 & Room 4)
PRVT780 • If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system.
ACCESSORIES
• After installation of additional indoor unit, you just need refrigerant charging for “A” section.
• Then, open the Stopper Valve.
Cut inlet side of the connector, and weld In case of the installation of additional
the pipe indoor unit, outlet side connector should
PRVT980
be cut according to installation pipe.
9.52 : 19.05
3.0m
9.52 : 15.88
234 235