You are on page 1of 4

Client Consultant

Consultant Project No: Status : IFA Transmittal No:T-125 Page : 1 of 4


Document Title: Data Sheet for Air Compressors and Air Dryers

Proj. No. Field Disc. Type Sequence No. Rev.


Document No. :
971002 ME DS 01 B2

Data Sheet for Air Compressors and Air Dryers

Revision Issue Date Description Prepared Checked Approved


Client Consultant

Consultant Project No: Status: IFA Transmittal No: T-125 Page: 2 of 4


Document Title: Data Sheet for Air Compressors and Air Dryers
Project No. Field Discipline Type Sequence No. Revision
Document No.:
971002 ME DS 01 B2

TABULATION OF REVISED PAGES


PAGE B0 B1 B2 B3 B4 B5 B6 B7 PAGE B0 B1 B2 B3 B4 B5 B6 B7
1  51

2  52

3    53

4    54

5 55

6 57

7 62

8 63

9 64

10 65

11 66

12 67

13 68

14 69

15 70

16 71

17 72

18 73

19 74

20 75

21 76

22 77

23 78

24 79

25 80

26 81

27 82

28 83

29 84

30 85

31 86

32 87

33 88

34 89

35 90

36 97

37 98

38 99

39 100
Client Consultant

Consultant Project No: Transmittal No:T-125 Page : 3 of 4

Document Title: Process Data Sheet for Air Compressors and Air Dryers

Proj. No. Field Disc. Type Sequence No. Rev.


Document No. :
971002 ME DS 01 B2

LOCATION:

ITEM: AIR COMPRESSOR PACKAGE-OIL FREE

TAG NO.:

AIR COMPRESSOR PACKAGE CONDITION (Note 1)

PROCESS CONDITION (Note 3) GENERAL DATA

Fluid Air No. Required 16

Capacity,(Rated) (Note 1) Sft3/min (Dry) 150 Drivers Electrical


Non-lubricated
Inlet Temperature °C 0-52 Type (Note 2)
reciprocating piston
Outlet Temperature °C Max.65 Area Classification Unclassified

Design Temperature °C VTA SCOPE

Inlet Pressure Barg Atm. Driver YES

Outlet Pressure, Barg Barg 10.34 Inlet Air filter / Silencer YES

Design Pressure, Barg Barg 13.5 Automatic drain YES

Min.Working Pressure, barg Barg VTA Compressed Air cooler YES

Max. Working Pressure, barg Barg VTA Oil Separator NO

INSTRUMENTS AND CONTROL Water Separator YES

Interface Signal with Purchaser's Control System Lube Oil System YES

1. Common Fault Alarm YES Drain / Vent valve YES

2. Start / Stop Commands YES Safety Valves YES

3. ESD Command YES Common base plate skid YES

4. Air Press. on Discharge YES Gasket , Bolts, Nuts YES

5. Tempreture switch high high on Discharge YES Acoustic Enclosure YES

6. Local / Remote YES Instrument control panel YES

6. Running YES Name plate YES

6. Pressure Switch high high on discharge YES

7. DPSH on Suction YES

SITE CONDITION

Elevation, m 19

Ambient Temperature, oC (MIN/MAX) 0/52

Relative Humidity, % (MIN/MAX) 10/100

Barometric Pressure (MIN/MAX) 1006.6/1008.6

NOTES

1- Startup and two years’ spare parts for this package with continuous operation is in scope.

2- According to IPS-M-PM-211 & API 680 standard

3- Unusual condition: Dust, Fume, H2S gas in air (Max. 10ppm).

4- MECHANICAL DATA SHEET MUST BE PREPARED IN DETAILED DESIGN.


Client Consultant

Consultant Project No: Transmittal No:T-125 Page : 4 of 4

Document Title: Process Data Sheet for Air Compressors and Air Dryers

Proj. No. Field Disc. Type Sequence No. Rev.


Document No. :
971002 A235-ACD ME DS 01 B2

LOCATION

ITEM: AIR DRYER PACKAGE

TAG NO.: -

AIR DRYER PACKAGE CONDITION EQUIPMENTS

No. Required 8 Pressure guage Yes

Type Heatless Regenerative Moisture Indicator Yes

Yes, Coalescing pre filter and Yes (PLC


Pre and After Filters Electronic Controller
particular after filter based)

Fluid Air Status Indication Yes (Lights)

Capacity, Nm3/hr (Dry) (Rated) 510 Relief Valves Yes

Operating Temperature, oC Max. 60 Muffler or purge nozzle Yes

Design Temperature, oC 82 Fill and Deain Ports Yes

Inlet Pressure, Barg 4/10 Pressure Switch Yes

Outlet Pressure, Barg 9 Regulator Yes

Design Pressure, Barg 13.5 Differential pressure transmitter Yes

Max. Oil content @ Package Inlet, mg/m³ 5 Temp. Gauge Yes

Name Plate Yes


3
Solids, g/Nm < 0.1
AT Yes

Max .Allowable Pressure Drop, Bar According to IPS-E-PR-330 Drain / Vent Valves Yes

Dew Point @ Package Outlet Max. -10 C @ 9 barg

Inlet Filter Capability VTA

Max. Outlet Filter Capability , Micron 5

NOTES

1- MECHANICAL DATA SHEET MUST BE PREPARED IN DETAILED DESIGN.