Roof and Wall Bracing Design Analysis

The document summarizes the design of various structural bracing and strut members. It provides the dimensions, forces, material properties and checks calculations to ensure the members have sufficient capacity and slenderness ratios. The roof bracing, wall bracing, and multiple strut tubes are designed and their capacities are verified to be adequate for the calculated loads.

Uploaded by

jatin kalra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
750 views7 pages

Roof and Wall Bracing Design Analysis

The document summarizes the design of various structural bracing and strut members. It provides the dimensions, forces, material properties and checks calculations to ensure the members have sufficient capacity and slenderness ratios. The roof bracing, wall bracing, and multiple strut tubes are designed and their capacities are verified to be adequate for the calculated loads.

Uploaded by

jatin kalra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
  • Design of Roof Bracing
  • Design of Strut Tube
  • Data Analysis of Structural Forces
  • Summary Data

1.

)Design of Roof Bracing

Diagonal Length of Brace member = 10.29 m


Force in the bracing = 236.25 kN
(L/C =337 Beam 5090)
Using Pipe 100 NB
Area = 1550.0 mm2 8.00 M

Check for Capacity of Member = 352 kN 6.5 M


(Tension Force)
Load carried by member O.K

Check for Slenderness Ratio

Effective length of the member = 10.29 m


Radius of Gyration = 38.9 mm

Slender ness ratio = 265

Slender ness ratio is less than 350

OK

2.) Design of Wall Bracing


Diagonal Length of Brace member = 7.61 m
Force in the bracing = 125.00 kN
(L/C =338 Beam 4152)
Using Pipe 100 NB 4.5 thk
Area = 1550.0 mm2 4.00 M

Check for Capacity of Member (Tension = 352.0 kN 6.5 M


Load carried by member O.K

Check for Slenderness Ratio

Effective length of the member = 7.61 m


Radius of Gyration = 38.9 mm

Slender ness ratio = 196

Slender ness ratio is less than 350

OK

3)Design of Strut Tube1


Length of Strut Tube = 6.47 m
Max. Force in the member = 176.00 kN
(L/C =378 Beam 5195)
Using Pipe 150 NB 4.8 thk
Area = 2420 mm2

Effective length of the member = 5.50 m


Radius of Gyration = 56.7 mm
Slender ness ratio = 97

Check for Capacity of Member (Comp) = 261 kN


Load carried by member O.K

4)Design of Strut Tube1(Near Gable End)

Length of Strut Tube = 6.47 m


Max. Force in the member = 193.00 kN
(L/C =333 Beam 2214)
Using Pipe 150 NB 4.8 thk
Area = 2420 mm2

Effective length of the member = 5.50 m


Radius of Gyration = 56.7 mm
Slender ness ratio = 97

Check for Capacity of Member (Comp) = 261 kN


Load carried by member O.K

4)Design of Strut Tube1(Wall Strut)

Length of Strut Tube = 6.47 m


Max. Force in the member = 197.00 kN
(L/C =333 Beam 3651)
Using Pipe 150 NB 4.8 thk
Area = 2420 mm2

Effective length of the member = 5.50 m


Radius of Gyration = 56.7 mm
Slender ness ratio = 97

Check for Capacity of Member (Comp) = 261 kN


Load carried by member O.K

5)Design of Strut Tube2(Internal Bottom Chort in grid b/w 3&4)

Length of Strut Tube = 6.47 m


Max. Force in the member = 568.00 kN
(L/C =333 Beam 3651)
Using Pipe 200 NB 8 thk
Area = 5308 mm2

Effective length of the member = 5.50 m


Radius of Gyration = 56.7 mm
Slender ness ratio = 97

Check for Capacity of Member (Comp) = 573 kN


Load carried by member O.K
Beam L/C Node Fx Mton Fy Mton
8.00 M Max Fx 4028 280 1.5(DL 554 0 0
Min Fx 5090 337 1.5(DL 248 -23.627 0
Max Fy 4004 280 1.5(DL 182 -4.798 0.112
Min Fy 4004 280 1.5(DL 213 -4.766 -0.112
Max Fz 4004 280 1.5(DL 182 -4.798 0.112
Min Fz 4004 280 1.5(DL 182 -4.798 0.112
Max Mx 4004 280 1.5(DL 182 -4.798 0.112
Min Mx 4004 280 1.5(DL 182 -4.798 0.112
Max My 4004 280 1.5(DL 182 -4.798 0.112
Min My 4004 280 1.5(DL 182 -4.798 0.112
Max Mz 4004 280 1.5(DL 182 -4.798 0.112
Min Mz 4004 280 1.5(DL 182 -4.798 0.112

Min Fx 4152 338 1.5(DL 893 -12.449 0.065 0 0

4.00 M

Max Fx 2214 333 1.5(DL 1081 19.221 0.065 0 0


Max Fx 5195 378 (0.9DL+ 248 17.602 0.039 0 0 0 0

Max Fx 3651 333 1.5( 956 19.72 0.065 0 0 0 0


Max Fx 5324 313 1.5(DL+ 106 56.845 0.065 0 0 0 0
Fz Mton Mx MTon- My MTon- Mz MTon-m
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0

0 0

0 0

1.)Design of Roof Bracing 
Diagonal Length of Brace member      
          = 
10.29 m
Force in the bracing
          = 
236.2
Length of Strut Tube      
          = 
6.47
m
Max. Force in the member
          = 
176.00 kN
(L/C  =378 Beam 5195)
Using
(L/C  =333 Beam 3651)
Using  Pipe   200 NB  8 thk
Area 
          = 
5308
Effective length of the member 
=
5.50
m
Radius of
Beam
L/C
Node
Fx Mton
Fy Mton
8.00 M
Max Fx
4028 280 1.5(DL
554
0
0
Min Fx
5090 337 1.5(DL
248
-23.627
0
Max Fy
4004 280 1.
Max Fx
5195 378 (0.9DL+
248
17.602
0.039
0
0
0
0
Max Fx
3651 333 1.5(
956
19.72
0.065
0
0
0
0
Max Fx
5324 313 1.5(DL+
106
56.845
0.065
0
0
0
0
Fz Mton
Mx MTon- My MTon- Mz MTon-m
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

You might also like