Step 1 : Define Pier labels for every wall in the plan,for instance name a wall as pier 1.
Step 3: Now after meshing the pier go to base plan and select the nodes of Pier 1 and
assign the supports as fixed
Step 7:Go to Shear wall Design Select view revise pier overwrites and select C & T
method if u are designing the Shear wall to take Axial Forces & Moments.
If u designing Shear wall of uniform thickness no need of defining Boundary
elements in ETABS 2013 onwards as it calculates itself, provides reinforcement for
entire shear wall considering Axial load and moment.
Step 8: Now design the wall to get reinforcement, Etabs displays 2 reinforcements
one is for compression Zone and another for tension Zone.
Step 9: After getting Reinforcement say u got 4000 Sqmm for Compression and
4500 Sqmm for Tension zone. on safet side i consider 4500asmm as my
reinforcement to be provided.
If you want to design a wall just as a reinforced wall design the wall as uniform
reinforcing.
for detailing go through IS 13920 latest version,codes specifies a min thickness of
150mm for shear walls.