Professional Documents
Culture Documents
FAKULTAS TEKNIK
GEO-ENGINEERING RESEARCH GROUP
Jl. Majapahit No. 62 Mataram
Laporan No. : Dikerjakan Tgl :
Tgl Diterima Sampel : Dikerjakan oleh : RINA
Klien : CV. KEKALIK MULTI CIPTA Diperiksa : Dr DSA
Proyek : KEGIATAN PUMPING TEST MATA AIR TUTUK
Ultimate bearing capacity of pile foundation using SPT data = Qf (Meyerhof) Abqf+Asfs
N = number of blows / 30 cm Ab = area of pile base As = area of pile side
D = depth of pile fs = side resistance qf = base bearing capacity
B = diameter of pile F = factor of safety Qall = allowable bearing capacity
Location :
BH1
D N N ave B Ab qf fs As Abqf Asfs Qf Qa Berat Cek
cm Blow/30cm cm m2 m2 kN ton Struktur kontrol
200 50 50 20 0.03 20000 100 1.60 628.32 160 788 26.79 82.34 NO
400 42 20 20 0.03 33600 40 3.20 1056 128 1184 40.22 82.34 NO
600 47 23 20 0.03 56400 46 4.80 1772 221 1993 67.71 82.34 NO
800 50 28 20 0.03 80000 57 6.40 2513 363 2876 97.72 82.34 OK
1000 50 50 20 0.03 100000 100 8.00 3142 800 3942 133.93 82.34 OK
1200 50 32 20 0.03 120000 65 9.60 3770 621 4391 149.19 82.34 OK
1400 50 50 20 0.03 140000 100 11.20 4398 1120 5518 187.50 82.34 OK
1500 50 50 20 0.03 150000 100 12.00 4712 1200 5912 200.90 82.34 OK