You are on page 1of 1

451886155.

xls MITCHEELL ENGINEERING PROGRAMS

COPYRIGHT 1990 MITCHELL ENGINEERING, PO BOX 1492. GOLDEN, CO, 80402, USA (303) 273 3744

PUMPING RATES FOR CEMENT SPACERS


12.25 in HOLE DIAMETER
9.625 in PIPE OD
0.85 POWER LAW INDEX "n" OF FLOW BEHAVIOR
70 % CASING STANDOFF AT CENTRALIZER; fr
600 CRITICAL DYNAMIC SETTLING FACTOR

-2.36165 MORAN CONSTANT 'A'


1.15563 MORAN CONSTANT 'B'
0.01433 MORAN CONSTANT 'C'
0.65979 MORAN CONSTANT 'D'
32.70269 MORAN CONSTANT 'E'

3.74 bpm PUMP RATE TO PREVENT SETTLING

CDSF = 600 Prevents settling and re-suspends barite in annuli


CDSF = 800 Prevents settling and re-suspends sand and hemitite in annuli

PROGRAM DOS NAME: CMT_SPAC.XLS

PURPOSE: Design spacer hydraulics to prevent solids settling in the annulus

COMPUTATIONS:
1. Pump rate to prevent settling