You are on page 1of 4
APPLICATION LAYER OF P&ID AND PFD NAME LAYER] COLOR TNETYPE EXAMPLE latext WHITE IconTINUOUS — JATTRIBUT Text lsonver —faue CONTINUOUS — BORDER FOR ALL SIZE FORM ct wire ICONT-LINE CENTER LINE lemay cyaN lexis-PIP EXISTING PIPE FOR MAIN PROCESS lenin cyan lexis-Pir EXISTING PIPE FOR UTILITY/DRAIN PROCESS lEae GREEN IconTiInuous EQUIPMENT, VESSEL,PUMP ETC ew GREEN lELec-LN SIGNAL ELECTRICAL lEqPH GREEN |H10DEN EQUIPMENT FUTURE Fas GREEN ure FUTURE LINE MAIN PIPING Min GREEN Furie FUTURE LINE UTILITY PIPING lrree-text freccow —‘ continuous _frext cra were continuous —JaRROW, SPECIAL ITEM Ins YeLLow CONTINUOUS _BALLON,LINE PNEUMATIC SIGNAL, TEXT BALLON livs-asH —fretcow — HIDDEN IBALLON,LINE PNEUMATIC, TEXT BALLON |euTURE) mas etLow continuous LINE sain Veccow —conminvous une Pir GREEN continuous — |vatve. FrTTincs Pu IMacenta — pHaToM POLYLINE process WHITE continuous HEAT TRANSFER EQUIPMENT Revision —freccow —conrinuous revision su IMacenta — |skio-LIM Iskio Liniits sprrem GREEN continuous |sPec Tem LINE THICKNESS TEXT No_[_COLOR | THICKNESS Imm FEIGHT 1 [|_ReD OF Ne alls COLORS | EF iain! 2 [BLUE 08 |_| DRAWING TITLE | GREEN 5 3 | MAGENTA 04 2 [DIMENSION [YELLow[ 3 a_[- GREEN 03 3 [OTHERS —[Yewtow] 3 5 [YELLOW 015; 6_[_OTHERS 0.15 Note: Printing shall be monochrome. APPLICATION LAYER OF CIVIL & STRUCTURAL, NAME LAYER, [s0-STL. [30-CANAL. soc. [s001KE SDFACE |s0PLT SDRAIL larext BORDER, cu const DIMENS lEQP lEop-exis lEOp-FUT lEOPH IFREE-TEXT IFREE-TEXTM FIRE cna. HATCH MARKER PL Points REVISION RROAD Ist. IsTRC ISTRD IsTRP COLOR, WHITE WHITE MAGENTA GREEN YELLOW HITE GREEN WHITE BLUE MAGENTA HITE Icvan GREEN GREEN IREEN GREEN GREEN YELLOW GREEN MAGENTA. GREEN MAGENTA GREEN GREEN YELLOW cREEN MAGENTA YELLOW YELLOW YELLOW LINETYPE: CONTINUOUS, CONTINUOUS CONTINUOUS: CONTINUOUS: CONTINUOUS CONTINUOUS: CONTINUOUS CONTINUOUS CONTINUOUS ICENTER-LINE CONTINUOUS CONTINUOUS CONTINUOUS EOP-EXIS EQP-FUT HIDDEN CONTINUOUS ICONTINUOUS CONTINUOUS ICONTINUOUS CONTINUOUS ICONTINUOUS PHANTOM. CONTINUOUS CONTINUOUS: CONTINUOUS: ISKID-LIM ICONTINUOUS CONTINUOUS PHANTOM. EXAMPLE FOR sD ls0. l20, la0) ls0, ls0, }20 JATTRIBUT TEXT BORDER FOR ALL SIZE FORM ICENTER LINE JEXISTING PIPE FOR MAIN PROCESS JOIMENSIONS EQUIPMENT, VESSEL, PUMP, STAIR. EQUIPMENT EXISTING EQUIPMENT FUTURE EQUIPMENT HIDDEN LINE ITEXT FOR IMPERIAL, ITEXT FOR METRIC JFIRE SYSTEM EGP |ARROW FLOW, SPEC BREAK GRATING, PLATE. MARKER POINT /REFERENCES JLINE PLINE JTEMP POINTS/REFERENCES REVISION MARK-UP ROAD ISkiD Limits |STRUCTURE LINES STRUCTURE DASHED |STRUCTURE PHANTOM APPLICATION LAYER OF ISOMETRIC & PIPING PLAN NAME LAYER, FOOO0LE, HS000L8, HS00Le, so. l2000L8 }20000L8 l2500L8 ls000L8 [300.8 l4ooLs l5000L8 le000L8 ls00LB le00LB JoooLs JaTEXT BORDER IccL cons JoIMcNs EQP EQP-Exis EQP-FUT. EQPH EXIST FREE-TEXT FREE-TEXM IcRa HATCH Ins. Is-DASH MARKER, IMTAG PIPE-DASH POINTS: REVISION Is. IstRC IstRO [sTRE COLOR MAGENTA’ IcvAN IcREEN YELLOW cREEN WHITE WHITE YELLOW IcREEN ISLUE JcREEN WHITE Icvan IcREEN MAGENTA. |WHITE/BLACK IcvAN BLUE IcvAN lvcLLOw GREEN GREEN GREEN GREEN IcvAN GREEN YELLOW MAGENTA YELLOW YELLOW YELLOW MAGENTA GREEN WHITE GREEN YELLOW GREEN YELLOW VELLOW YELLOW LINETYPE CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUGUS CONTINUOUS CONTINUOUS ICONTINUGUS ICENTER.LN CONTINUOUS CONTINUOUS: CONTINUOUS EQP-EXIS EQP-FUT HIDDEN EQP-EXIS CONTINUOUS CONTINUOUS CONTINUOUS ICONTINUGUS CONTINUOUS HIDDEN CONTINUOUS CONTINUOUS HIDDEN CONTINUOUS CONTINUOUS ISKID-LIM CONTINUOUS CONTINUOUS PHANTOM. EXAMPLE ISPEC FOR CLASS 10000LB |SPEC FOR CLASS 1500018 SPEC FOR CLASS 1500LB |SPEC FOR CLASS 150L8 OR STD SPEC FOR CLASS 2000LB |SPEC FOR CLASS 2000018 |SPEC FOR CLASS 250018 ISPEC FOR CLASS4000LB |SPEC FOR CLASS 30018 SPEC FOR CLASS 400LB |SPEC FOR CLASS 500018 ISPEC FOR CLASS 6000.8 |SPEC FOR CLASS 60018, |SPEC FOR CLASS 80018 SPEC FOR CLASS S00LB [TEXT-ATTRIBUTE BORDER FOR ALL SIZE FORM CENTERLINE FOR FITTING (ELBOW, TEE ETC } IEXISTING PIPE FOR MAIN PROCESS DIMENSIONS EQUIPMENT, VESSEL,PUMP ETC. EQUIPMENT EXISTING EQUIPMENT FUTURE EQUIPMENT HIDDEN LINE |ARRANGEMENT EXISTING JALL TEXT FOR IMPERIAL, JALL TEXT FOR METRIC |ARROW LINE, SPEC BREAK GRATING, PLATE BALLON, LINE PNEUMATIC SIGNAL, TEXT BALLON BALLON, LINE PNEUMATIC, TEXT BALLON ( FUTURE ) POINTS FOR REFERENCES MATERIAL TAGS LINE PIPE DASHED [TEMP POINTS REVISION MARK-UP ISKID LIMITS STRUCTURE LINES |STRUCTURE DASHED STRUCTURE PHANTOM APPLICATION LAYER FOR ELECTRICAL SCHEMATIC NAMELAYER| COLOR LINETYPE EXAMPLE Nsw GREEN CONTINUOUS JALL TERMINAL, TRANSFORMER, GROUNDING linsw JoREEN contINuoUS — |FUSE,CONTACTOR,RELAY, LIGHT,SPECKER livsw JoREEN continuous — overLoan insw GREEN CONTINUOUS — [SOLENOID nsw GREEN continuous — BATTERY nsw GREEN continuous |moror livsw JcREEN continuous — PUSH BUTTON nsw GREEN continuous — LIMIT SwiTcH iwsw GREEN continuous — cou spare IGENC JcvAN CONTINUOUS _ PAIR TRIAD SYMBOLJUMPER IGenc ICvAN continuous TAG NUMBER CABLE (CONDUIT) IGenc IcvAN continuous — GENERATOR CONNECTOR IGenc JCvAN continuous — |(DELTA/"Y" DELTA) IGEN ICVAN continuous RESISTOR sus GREEN continuous — pus IGENF JoREEN continuous — Generator IGENF GREEN CONTINUOUS FEEDER CONN MAGENTA CONTINUOUS _SINGLE LINE Fut GREEN FUT-ELEC FUTURE LINE FOR ELECTRICAL exis VELLOW. continuous —_|exisTiNG es VELLOW. continuous — |iNTERLOCK ECON GREEN continuous — |coNbuIT lerir JcREEN continuous — ELEC FITTING lELEX GREEN CONTINUOUS — ELEC LIGHTING MATCH MAGENTA __|DASH/DOT. MATCHLINE NOTE FOR ARRANGEMENT LOCATION/LAY QUT OR EQUIPMENT L/O APPLY STRUCTURAL LAYER FOR ATTRIBUTE/FORMAT BORDER, TEXT ARROW OR GENERAL APPLY SAME LAYER P&D PFD.

You might also like