Portfolio InCCA - Key Messages

Positioning - Target Customer

Strengths

Distribution - Sales
Portfolio InCCA

Intelligent Clinical Chemistry Autoanalyzer

Excellent relation between cost / benefit


InCCA joined technology, functionality and productivity.
Programmed to perform clinical chemistry, immunochemistry, DOA, TDM, enology
among others
Clinical Chemistry • 120 tests/hour – 200 test/hour w ISE
Autoanalyzer • Maintenance alarm program
• Continuous input samples and reagents
during running
• Impact and level sensors probe
• Removable reagent tray
• Auto re-run and auto-dilution
• Low water consumption: 500ml/h
• Reagent inventory check

Excellent for veterinarian • OPTIONALS: ISE (Li, Cl, Na, K), Barcode reader,
laboratory extra interferential filter, cooling system
Clinical Chemistry • 150 tests/hour – 250 test/hour w ISE
Autoanalyzer • With cuvette washer
• Maintenance alarm program
• Continuous input samples and reagents
during running
• Impact and level sensors probe
• Removable reagent tray
• Auto re-run and auto-dilution

With Cuvette Washer • Low water consumption: 500ml/h


• Reagent inventory check
Excellent for veterinarian • OPTIONALS: ISE (Li, Cl, Na, K), Barcode reader,
laboratory extra interferential filter, cooling system
Clinical Chemistry •300 test/hour – 500 test/hour w/ISE

Autoanalyzer •Reagents cooling system


•Chemical and automatic cuvettes washer
•Continuous input samples and reagent during
running
•Auto re-run and auto-dilution
•Low water consumption: 1.2 l/h
•Maintenance program alarm
•Reagent inventory check
•Impact and level sensors probe
•OPTIONALS: ISE (Li, Cl, Na, K), Barcode reader,
extra interferential filter
Key Messages

COMPACT

VERSATIL

RELIABLE

PRODUCTIVE

INTELLIGENT
Key Messages

COMPACT

Benchtop units
InCCA: 80cm x 45cm x 65cm – 50kg
InCCA Bit: 80cm x 47cm x 58cm – 45kg
Key Messages

VERSATIL

Open system or closed (trough software key)


Adding samples and reagent at any time
Multi languages
Customized analyzer and software (OEM option)
Direct reading absorbance
Wide range of Interferential filters
(any wavelength could be added)
Key Messages

RELIABLE

Optimum result
Bichromatic wavelength
Kinetic reaction curve with linearity check protection
Automatic confirmation result

PRODUCTIVE

Real walk away systems


Adding samples at any time
LIS
Key Messages

INTELLIGENT

Password protected
Maintenance alarm program
Automatic redilutions and repetitions
Close or open reagent system
Key Messages

• Primary tube 12-13 x 75-100 mm


• Pediatrics sample cups
• Probe with impact and level sensors
• Internal and external probe washing

Productivity, Economy, Versatile


and Reliable
Productivity, Economy, Versatile
and Reliable

InCCA Sample and Reagent Tray

60 positions for sample (continuous loading)


60 reagent positions
Reagent tray cooling system with independent key
prolongs the life of the equipment
Barcode for sample tubes (optional)
Low reagent consumption (200ul/test)
Samples and reagents preheating
No limit for STAT positions
Productivity, Economy, Versatile
and Reliable

Easy to use
Bar Code Identification
Ready to use in 10 minutes
Automatic Washing, minimal water consumption
Friendly software
Simplified maintenance

Reduced Maintenance
Daily Routine: Cuvette and probe wash
Weekly Routine: Photometer and Cuvettes calibration
Productivity, Economy, Versatile
and Reliable
User levels
Different languages
(Spanish – English – Portuguese – Chinese – Russian –
Hungarian - French)
Windows and Linux versions
Unlimited number of methods, calibrator and control files
Different reagents tray
Software HTML Settings for printing
Statistics patients, calibrators and controls
FRIENDLY
Quality Control Graphics
Associations with different LIS systems
EASY TO USE Graphics kinetic reactions
Validation Test for instrumental checking with NIST
traceable solutions (direct absorbance readings)
INTUITIVE
Productivity, Economy, Versatile
and Reliable

Maintenance Levels
No more 6 or 12 month maintenance. Trough this program the parts will be changed at the real wear out
time, cycle counters are on board counting the real work of the parts, software will flag at the moment the
parts need to be changed, saving money and time
Positioning

TEST
HOUR

300- 450

30 - 400 pat/day
240-320

80-120 With cuvette washer


5 - 100 pat/day

2 - 100 pat/day

LOW MEDIUM HIGH VOLUME


Customer Target

60 - 600 test per day

300 - 2400 test per day


Strengths InCCA analyzers

•Benchtop fully automated random access analyzers

•Throughput: from 100 to 500 test/hour

•Open systems

•Automatic Cuvettes Washing systems (not for InCCA Bit)

•Reusable Cuvettes: long life (more than 500,000 test)

•InCCA analyzers read direct Absorbance

•Preventive maintenance alerts

•Confidence result
Strengths InCCA

•Instrumental control in the software, guarantee in the results report


•Integrated mixing system that prevents the probe contamination
•Productivity:
• Fast and accurate results cost effectively
• Unlimited programmable methods, calibrators and controls.
•Substrate consumption monitoring, prevents report normal samples instead of
pathological
•Cut Off Method Report, allows process drug abuse test, therapeutic drugs
•Versatility: read different wavelength. Extra applications lab, Ex.: Wine analysis
•Reagent cooling with optional On/Off key to keep reagent at best situation, extend
the shelf life of the parts instrument
Distribution - Sales

InCCA® Systems installed

Around 2000 units installed


Contact Us

www.diconex.com Ines Lopez

Internationals Sales
sales@diconex.com

Torcuato de Alvear 46 - Quilmes - CP: B1878DHB - Buenos Aires - Argentina


Tel./Fax: +54 11 4252 2626

You might also like