FO-551-105 Rev.0 Page 1gs Interested Parties (Vendor / Sub Contractor) Audit Report
Goltens
1, Date of Audit : 11 / 12 / 2019
2. Area of Audit:
{aso9001_| BJ |1s014001 L_Joxsasisooi/isoasooa | X |
3. Sites Audited: Voyage Marine Automation
P.O.Box No. 119218, Dubai Maritime City, Dubai - UAE
4, Scope of Audit: Calibration, supply, Servicing, Installation, Testing & Commissioning of
automation, electrical & instrumentation by Voyage Marine Automation to Goltens Co. Ltd. (Dubai
Br)
5. Auditor(S): Mr. Spancer Fernandes
6. Auditee (S) :
EIU ete br
Dr. Jayasree Manager — Administration 11/12/2019 |
Prasannan & Quality Systems
Suresh Panicker | Manager ~ Calibration 11/12/2019
Services
Mithun K.K. Calibration Engineer 11/12/2019
™
List of Documents Referred:
ims
Verification of Thermal Stabilization
1._| Records of Vernier Caliper (0-300mm)
Temperature records dated
24" Nov. 2019 @ 08:40Hrs
Verification of calibration of zero grade
2._| surface table
Sr.#i 1873694E03 Calibration
Due: 17.08.2020
Verification of calibration of Master
3._| Equipment gauge block 1.001 - 100mm
# 1001489, Calibration Due:
15.05.2020
Verification of scheduled maintenance of
4. | master equipment gauge block 1.001 —
100mm, once in every 2 months.
QP-06-04 Rev.03
Verification of acceptance criteria for
5._| vernier caliper 0-300mm.
Competency requirements for Calibration
6. | Engineer as per set Voyage Marine
‘Automation skill matrix.Ss Interested Parties (Vendor / Sub Contractor) Audit Report
Goltens
7. | Job Sheet for Calibration of Digital Vernier | Job. Sheet No. 19100203
Caliper
Executive Summary:
The organization has been certified with ISO 9001-2015 & 1SO 18001:2007 by Bureau Veritas
Certification with the following scope.
“Calibration, Supply, Servicing, Installation, Testing & Commissioning of Automation, Electrical &
Instrumentation Navigation and Communication Equipments, Life Saving Appliances and Fire Fighting
Appliances for Marine, Oil/Gas and Industrial Fields”
‘The organization is also certified with ISO/IEC 17025:2005 by Emirates Industrial Accreditation Centre for
General requirements for the competence of testing and calibration laboratories
The procedures for various activities at Voyage Marine Automation are well documented. Evidence for
management commitment, customer satisfaction and continuous improvement does exists in the
organization. Maintenance of Tools & Equipments has been conducted at regular intervals to meet the
minimum intent. Quality, health and Environmental policies are available and verified,
9. Non Conformities and Observation
-_Refer below detailed non — conformance / observation summai
Finding by Goltens ReiSeaeecicen Ceci nn Aan cd
Corie Poe Reds Cry
Refer to [SO 9001-2015 Clause | Observation
Control of Documented
Information: 7.5.3.1
Documented information
required by the quality
management system and by this
international standard shall be
controlled to ensure it is available
and suitable for use, where and
when it is needed.
Voyage Marine Automation has
well documented Work
instructions for the calibration
activities. The acceptance criteria
for vernier caliper mentioned on
the Work Instruction (WI-CO8)
states +0.001mm, but could nat
be verified as per !SO 14978:2005
at the time of audit.
FO-551-105 Rev. Page 3Ss Interested Parties (Vendor / Sub Contractor) Audit Report
Goltens
10.Acknowledgement
The auditee has read and agrees the audit report and will act with the
corrective actions.
seer
Te MNO
In Copy Mr. Girish M. (SCM, Goltens)
Gob Title) Mr. Thomas Kurien (Head of QHSE, Goltens)
FO-S51-105 Rev. Page 4