Calculation of a pulse transformer

Initial data:
Converter topology: "Push-Pull"
The desired diameter of the primary wire: 0.5 mm
Transistor type: MOSFET
Resistance to open<br>channel (Rds (on)): 0.085 Ohm

Supply voltage: AC voltage


Minimal Nominal Maximal
6V 12 V 13 V

Core selection:
Core type: [E 25/13/7 N27 Epcos]
Relative effective permeability: 1520
Saturation magnetization: 0.181 T
Frequency of operation of the converter: 33000 Hz

Type of output rectifier: Bridge rectifier


Required voltage in the secondary winding: 220 V
Required secondary current: 0.05 A
Desired wire diameter of the secondary winding: 0.5 mm
Forced cooling: Yes
Voltage drop on diodes: 0.7 V

Calculated data:
Overall power of the core: 61.2 W
Power Consumption: 12 W
Converter efficiency, without loss: 97.46 %
Coefficient of filling the window: 0.069
Wire diameter by skin effect: 0.609 mm
Number of turns of primary winding: 10+10 turns
Diameter of the primary wire: 0.69 mm
Diameter of the primary wire: 0.5x2 mm
Primary winding inductance: 0.18 mH
Number of turns of the secondary winding: 293 turns
Diameter of the secondary wire: 0.1 mm
Diameter of the secondary wire: 0.5x1 mm

Output voltage:
Minimal Nominal Maximal
108.6 V 220.6 V 239.3 V

Calculation of pulse transformer Website: http://vip-cxema.org/