You are on page 1of 2
Photometer 5010 ve DEPKES RI AKL 10102011427 Semi - automated photometric system Flexsible cuvette concept Effective temperature regulation system Double-secured liquid control Open system : high capacity for programmable methods JRJDE IIE Eratalogue peace Type Light Wavelength Wavelength Selection Photometric Range Cuvette System ‘Temperature Control Semi automatic, single-beam, double-beam filter photometer Source Halogen lamp — 12V,20W 340 nm - 800 nm ‘Automatic via 9-position filter wheel : 6 standard interference fiters: 340 nm, 405 nm, 492 nm,546 nm,578 nm, and 623 nm;3 positions for optional fiters of choice 0-250 Micro flow cell: 32_ 1,10 mm light path interchangeable with normal standard cuvettes ( macro of semi-micro,disposable or special glass) Internal Peltier element,temperature variable, pre-adjusted to 25 C,30 C, and 37 C Equilibration eo for aspirated reaction mixture to reach 37 C from ambient temperature: 15 sec Aspiration System Sipping Volume In peristaltic pump driven by stepper motor, programmable aspiration volume controlled by infrared light barier (buble detector) 250 110 2000 |, programmable for sample as well a for washing in 50_ I steps Presentation Integrated Printer Languages Memory Data Logging Signal Port Measurement Procedures Measuring Time Delay Time Dimensions Weight Marking ‘Touchscreen, graphie display,240 X 128 dots, blue, backlight Dot-matrix printer, 24 characters per line English and Indonesian General operating soffware contained in FLASH MEMORY can be updated by PC (data file downloaded from Internet or CD ROM ) Capacity for 250 pre-programmed tests Up to 230 tests can be stored in RAM. Import of data by keyboard or PC Up to 50 non-linear calibration curves with max 20 sets of points can be store Up to 2970 results of max 99 samples can managed in the memory Serial port for connection to an external printer and/or PC + Absorbance End point with factorstandard or multiple standard, with or without reagent blank and/or sample blank Kinetics with standard, factor or multiple standards, with or without reagent blank Fixed time with standard, factor or multiple standards, with or without reagent blank Turbidimetry Single, Double and triple determinations Curve fitting for non-linear standard curves Available QC program Kinetic: variable from 3 ~ 25 deltas, time per delta 4 ~ 255 sec in 1 sec steps Fixed time: variable from 0 ~ 65535 sec in 1 see steps Programmable from 0 ~ 65535 sec in 1 sec steps Length 33 cm X width 34 em X height 18 em kg ce fe 6/1105 motions DISTRIBUTOR : Gedung RNI, JI. Denpasar Raya Kav. Dill Kuningan Raja Wali Nusindo :ssare'12380 indonesia RNI Group Phone : (021) 252 3820 (Hunting) Fax. (21) 52914239 www nusindo.co id

You might also like