Professional Documents
Culture Documents
Venus Simulation 1
Venus Simulation 1
PVsyst TRIAL
Simulation variant :
Simulation parameters
Collector Plane Orientation
TF VENUS SIMULATION 1
Simulation date
System type
Tilt
19/12/19 12h11
PV Array Characteristics
PV module Si-mono Model Mono 250 Wp 60 cells Bifacial
PVsyst TRIAL
Original PVsyst database Manufacturer Generic
Number of PV modules In series 5 modules In parallel 2 strings
Total number of PV modules Nb. modules 10 Unit Nom. Power 250 Wp
Array global power Nominal (STC) 2500 Wp At operating cond. 2217 Wp (50°C)
Array operating characteristics (50°C) U mpp 136 V I mpp 16 A
Total area Module area 16.3 m² Cell area 14.2 m²
PVsyst TRIAL
Temperature Fixed (20°C)
Controller Model Universal controller with MPPT converter
Technology MPPT converter Temp coeff. -5.0 mV/°C/elem.
Converter Maxi and EURO efficiencies 97.0 / 95.0 %
Battery Management control Threshold commands as SOC calculation
Charging SOC = 0.90 / 0.75 i.e. approx. 27.5 / 25.3 V
Discharging SOC = 0.20 / 0.45 i.e. approx. 23.6 / 24.6 V
PVsyst TRIAL
Serie Diode Loss Voltage Drop 0.7 V Loss Fraction 0.5 % at STC
Module Quality Loss Loss Fraction -0.8 %
Module Mismatch Losses Loss Fraction 1.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Incidence effect (IAM): Fresnel smooth glass, n = 1.526
0° 30° 50° 60° 70° 75° 80° 85° 90°
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000
PVsyst TRIAL
Battery Pack Nb. of units 4 Voltage / Capacity 24 V / 200 Ah
User's needs Daily household consumers Constant over the year Global 3451 kWh/year
Daily household consumers, Constant over the year, average = 9.5 kWh/day
Annual values
400
enegy
300
daily
200
of
100
Fraction
0
0 3 6 9 12 15 18 21 24
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.84 19/12/19 Page 3/6
PVsyst TRIAL
Battery Pack Nb. of units 4 Voltage / Capacity 24 V / 200 Ah
User's needs Daily household consumers Constant over the year Global 3451 kWh/year
Normalized productions (per installed kWp): Nominal power 2500 Wp Performance Ratio PR and Solar Fraction SF
8 1.2
PVsyst TRIAL
Lu : Unused energy (battery full) 1.52 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.468
1.1
7 Lc : Collection Loss (PV-array losses) 0.98 kWh/kWp/day SF : Solar Fraction (ESol / ELoad) : 0.642
Ls : System losses and battery charging 0.26 kWh/kWp/day 1.0
[kWh/kWp/day]
0.8
5
0.7
Energy
4 0.6
0.5
3
Normalized
0.4
2 0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
125.6
GlobEff
kWh/m²
114.6
TF VENUS SIMULATION 1
Balances and main results
E_Avail
kWh
236.3
EUnused
kWh
61.6
E_Miss
kWh
124.9
E_User
kWh
168.3
E_Load
kWh
293.1
SolFrac
0.574
February 123.4 115.0 239.1 64.4 97.9 166.9 264.8 0.630
March 143.3 138.0 283.6 96.1 114.9 178.2 293.1 0.608
April 140.4 138.8 285.9 90.6 99.3 184.3 283.7 0.650
May 157.5 163.2 333.3 130.0 100.2 193.0 293.1 0.658
June 153.9 163.5 335.0 135.6 96.9 186.8 283.7 0.658
July 166.9 176.6 360.3 153.2 97.0 196.1 293.1 0.669
August 177.7 182.2 370.4 161.9 96.8 196.3 293.1 0.670
September 174.6 171.6 347.0 144.7 94.7 189.0 283.7 0.666
PVsyst TRIAL
October 175.2 166.0 335.6 129.5 98.8 194.4 293.1 0.663
November 189.8 174.2 352.2 150.1 94.0 189.6 283.7 0.668
December 134.5 122.1 253.8 70.8 118.6 174.5 293.1 0.595
PVsyst TRIAL
Battery Pack Nb. of units 4 Voltage / Capacity 24 V / 200 Ah
User's needs Daily household consumers Constant over the year Global 3451 kWh/year
10
[kWh/day]
8
array
the
6
of
PVsyst TRIAL
output
the
4
at
energy
2
Effective
0
0 1 2 3 4 5 6 7 8
Global incident in coll. plane [kWh/m².day]
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.84 19/12/19 Page 5/6
PVsyst TRIAL
Battery Pack Nb. of units 4 Voltage / Capacity 24 V / 200 Ah
User's needs Daily household consumers Constant over the year Global 3451 kWh/year
+0.75%
Array nominal energy (at STC effic.)
PV loss due to irradiance level
PVsyst TRIAL
Missing energy
35.75% 2344 kWh
Direct use Stored
-4.55%
-0.04%
0.00%
0.00%
Converter Loss during operation (efficiency)
Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Battery Storage
31.1% 68.9% -0.13% Battery Stored Energy balance
-3.84% Battery efficiency loss
-1.79% Charge/Disch. Current Efficiency Loss
-0.27% Gassing Current (electrolyte dissociation)
-0.07% Battery Self-discharge Current
1234 kWh 2217 kWh Energy supplied to the user
PVsyst TRIAL
3451 kWh Energy need of the user (Load)
PVsyst TRIAL
Battery Pack Nb. of units 4 Voltage / Capacity 24 V / 200 Ah
User's needs Daily household consumers Constant over the year Global 3451 kWh/year
PVsyst TRIAL
System Lifecycle Emissions Details:
Item Modules Supports
LCE 1713 kgCO2/kWp 4.90 kgCO2/kg
Quantity 2.50 kWp 100 kg
Subtotal [kgCO2] 4282 490
40
30
Balance
20
10
PVsyst TRIAL
0
-10
0 5 10 15 20 25 30
Year
PVsyst TRIAL
PVsyst Evaluation mode