KEEL COOLING BY BOX COOLERS

ENGINE: C13ENTM50 (368 kW at 2000 rpm)

MAIN CIRCUIT HEAT RELEASE (cyl. block, head, exhaust manifold): 220000
kcal/h

MAIN CIRCUIT COOLANT FLOW: 31.5 m3/h

MAX COOLANT PRESS. DROP ACROSS THE KEEL COOLING SYSTEM (main): 0.2
bar

THERMOSTAT WORKING RANGE: 70-85 °C

MAX RECOMMANDED COOLANT TEMP. BOX COOLER OUTLET: 83°C (at 30°C
sea water temperature)

SECOND CIRCUIT HEAT RELEASE (INTERCOOLER): 70000 kcal/h

SECOND CIRCUIT COOLANT FLOW: 20 m3/h

MAX COOLANT PRESS. DROP ACROSS THE KEEL COOLING SYSTEM (second):
0.3 bar

MAX RECOMMANDED COOLANT TEMP BOX COOLER OUTLET: 45°C (at 30°C
sea water temperature).