Simply Capture Every Key Moment
a
we
os
=FireFly =>
Simple Design + Simple Operation
‘The design was inspired from the shape of firefly, The smart design
largely saves space for clinicians compared other bulky camera
systems. We have preset many camera parameters so the user
does not need to adjust settings before using the device. The user
‘can operate the machine immediately once the installation has been : i
finished. The device has the following automatic functions for photo
shooting and processing when equipped with our Mediview a
software: a
‘Auto Focus (During Setup)
‘Auto Exposure
‘Auto Gain
‘Auto White Balance
‘Auto OS/OD Indicator °
Adjustable Aperture
‘The aperture can be adjusted between 6
different levels to adjust depth of field and
brightness demands.
HDMI output
‘The HOM! output can be used to connect the
'$390H/S3901 sit lamp with a monitor. The
clinicians can share the live eye examination
image simultaneously with patient's family
‘members or students for for patient education or
teaching purposes.Optical resolution increased by 40%
High-qualty optical microscope with extraordinary resolution to
meet doctors higher optical qalty requirements for beter
‘curacy and sate eiagnostioresuts
Built-in yellow filter
Coaxial Illuminator
‘The new LED illuminators positioned coaxially tothe mi
It provides an agjustable croular Beam of ight to nha
igtal capturing etect,
Easier Installation
ur compact control pane! with built-in power supply makes it much
‘easier to install ho si amp especially won instaling the sit amp
fon an ophthalmic unt. The users do not need to find pace to instal
the chunky power box.
Quick Capture Button
‘Tnore is quick button on the contol pane! that en
te shoot photos conveniently. Once they observe the suitable
image to describe pathology, just press the capture button and the
image willbe recorded.
c08Software Features
Functional Image Analysis
Clinicians can measure the pathology area with
ur powerful software tools and change the
contrast and brightness of the images. Clinicians
can also compare several images at one time to
analyze the symptoms and pathology.
Customized Auto Exposure
Value Setting
Clinicians can customize auto exposure values
according to the image demand and save as templates
for future capturing purpose.
Aso, the printing report can be customized according to
clinician's needs.
Convenient Patient Management
The patient management system enables clinicians to
build and edit patient record, search information by
inputting keywords. Clinicians can easily record
symptoms and manage the data all the time. The
software supports DICOM which makes the images
captured by Firefly be easily integrated into hospital's
medical system.
Orthokeratology Lens Fitting
Assistance
The optometrists can capture and record high resolution
fluorescein images of lens fiting and real-time vide:
without a recording time limit. By comparing the different
lens fiting effects, the optometrist can show and educate
patients which lens is most suitable for them.Mediview Software
Driving patient compliance and retention through education.
Mediview is the image management system to help clinicians manage patient records and images captured by Firefly. By
showing patients the anterior segment images and pointing out pathologies, clinicians can educate patients and gain
their trust. In this case, both patient satisfaction and retention are improved.
« Clinic Mode
-i
2 ie
wt oo
CConaitaton Room 1
Et
/ \
ret | et
Cconeutaion Roam 2 Caneutaton Rom @
In clinic mode, there is one admin account which is.
capable of setting up and managing several user accounts.
‘The images and diagnostic records can be shared via
Local Area Network (LAN),
=a
if imaging Room if
‘consstation Room &
+ Telemedicine Mode
& =
JS
Figs
Regional Hosp
In telemedicine mode, the images and data are stored on a
‘loud server. Like clinic mode, the admin account can set up
‘and manage user accounts. As long as the user has access
to internet, they can review images and records at any place,
anytime.Specifications
Meroscope
Meroscone Type Gaiean THE
agntatin change Revoling Drum § steps
“Total Magnifation EK 10K 16K 28 40K
Exepkeces Task
‘Angle between Gyepleces =
upiany Adjustment Saen enn
Dlopter Adjustment 80-+89)
Feld of View @3620m, 23am, Blinn, OBInm, GSTAm
‘it umpation
SHWE ‘Orla continuous (et betomer a ercle at Line)
Stang =e continuous
‘Roertre Dameters én, Bion, OSnm, Ginn Gem, Ginn, BO erm
‘Swale oso"
Sc hahstion S10, 18, 20°
Aes eat sorbing titer, ND Titer, Reeree fier, Cobalt Bue iter Velow fier balla
tone av LED Module
‘aminance > 1500
Power Supply
Input Voreage Tlov=220v
input Frequency SOHEIGOHE
ower Consumatton 30¥A
‘Output Vora BVI, Praia Sv
Packaghe
Denson Tone x4 Tomm x S7UmmiUTAh
Grose welt 23g,
INetwelght Te
‘System Spectfcations
Image Sensor SOM Pees
Photo Resonton 2592 x 1948
Format We
Video Resehtibe 25024 1948
Frame of Viseo 25s
Video Formats weenie
‘posure Mode “Automatic eponure
‘Tansmisio pierce Usa 30 TEC
Shanghai MediWorks Precision Instruments Co.,Ltd.
|Adé:Zone A.2nd Floor No.68,Lane 1985, Chunshen Road Minhang Distt,
‘Shanghai 200237 China|
ol: 486-21-54260421 64260829 Fax:+86-21-54260425
Email: international mesiworks biz
A. CE FDAApproval
wwrw.mediworks.biz
2017108 “Sitjeco change in design or speciation who advance notion
Details Make the Difference