You are on page 1of 9

Cable Certifier

4500

1st Category 8 Cable Certifier

Certify @ Psiber Speed


Bandwidth-demanding applications require
WireXpert higher performance cabling and connectivity 1 - 2500 MHz
4500

To achieve optimum network performance, proper installation is


critical and must be verified with a tester capable of measuring
higher frequencies with the highest level of accuracy.

We invite you to look ahead T he WireXpert has a revolutionary 1 - 2500 MHz frequency measurement range. It has

been fully qualified and approved by major cable and connectivity manufacturers. With
and leverage the unique
certification testing up to Category 8 copper cabling, as well as MPO, SM and MM fiber optic
capabilities of our WireXpert
cabling, the WireXpert is ready for 40G and beyond. In fact, major cable vendors are using
Cable Certifier. the WireXpert in their labs for qualifying Category 8 cabling systems under development. As

a result, it is the only instrument you need to certify cables for today, and well into the future.

The revolutionary WireXpert


Cable certifying is all about speed and accuracy. The WireXpert engine lets you
represents a new revenue
deliver an industry-leading test time of 9 seconds for Category 6A. WireXpert
opportunity. Whether you employs a novel measurement architecture that achieves extremely wide bandwidth
are a cable manufacturer, with superior measurement accuracy. Its unique RF measurement engine exceeds

installer or the end user, the level IV and level V requirements throughout the measurement frequency range.

WireXpert delivers cable


Cable installers make significant gain in productivity with WireXpert‘s industry leading test
certification and network speed and ease of use. The Dual Control System (DCS TM) – featuring identical devices

assurance that pays back for remote and main units – reduces the amount of walking required between drops amd

on every level. makes it easy to operate by two technicians or only one to decrease labor costs. The

systems’ ReportXpert generates complete, ultra-professional documentation of all testing,

for installer and customers’ records. And, lets you re-certify to new standards as they are

approved, without having to revisit the site for additional testing. In addition, you have access

to evolving, easy-downloadable software updates and enhancements for your WireXpert.

CATEGORY 5e, 6, 6A, 8 & BEYOND


APPROVED PERFORMANCE APPROVED ACCURACY
WireXpert The WireXpert has been qualified and approved by over 20 major cable The WireXpert has been independently verified by highly respected
4500
manufacturers for field certification and associated warranties of their test laboratories such as ETL

structured cabling solutions.

INCREASED PRODUCTIVITY ADVANCED LEVEL V ACCURACY

The DCS (Dual Control System) allows one person to do the job that The WireXpert not only exceeds current level IV, but is the only tester that

would normally take two technicians to complete. Reducing labor rates meets the proposed level V accuracy requirements.

on every job.

EASY TO USE

An intuitive, touch-sensitive, color LCD user interface, makes cable

certification easier than ever.

EXPERT SOLUTION

The WireXpert engine lets you deliver an industry-leading test

time of 9 seconds for all testing through Category 6A.

TROUBLE SHOOTING GUIDE

Built-in help is available at the touch of a button, making a

reference manual unnecessary.

FAST & SIMPLE
 NEXT LEVEL READY LOW COST OF OWNERSHIP


The WireXpert’s two identical instruments, instead of the usual main and • Designed to minimize walking time and increase productivity through The 2500 MHz frequency range secures your investment into • With on-line semi-automated software upgrades.

remote units, allows testing from both ends. faster measurement cycles. requirements for cable certification of 40Gbps and higher • Independent adaptor modules for both channel and permanent

• Graphical display allows for new feature and user enhancements. Ethernet networks. link testing are designed with replaceable permanent link cords.

• Replace only the link cord instead of the whole module—providing

additional cost-saving over the life of the instrument..


COPPER & FIBER MAXIMUM EFFICIENCY
WireXpert Modern network infrastructure involves installing both copper and fiber The WireXpert’s Dual Control System Technology double your productivity
4500 cabling within the same premises. With the increasing demand for by using your remote unit as an independent optical certifier.

bandwidth, certification plays a crucial role for guaranteed data rates.

COPPER FIBER
Most advanced cable certification for all standards: Class C/D/E/EA/ Optional fiber adapters make full certification testing for MM (multimode)
FA, Category 3/5e/6/6A, and the new draft CAT 8 as well as ISO draft and SM (single mode) fiber installations possible. The WireXpert provides
standards Class I and Class II. you with a fast, easy and accurate way of determining the pass/fail criteria

of the installation across ISO/IEC or TIA standards.


• First cable certification up to 2500 MHz to support new TIA CAT 8 und

ISO Class I and II draft standard TIER 1 CERTIFICATION

• Insertion Loss (attenuation) and Length measurements.


• WireXpert’s measurement engine is already capable of testing against
• Perform Tier 1 Certification for ISO/IEC 14763-3 & TIA 568 C.3 standards
future cabling standards required for 40G and 100G Ethernet over
• Less than 6 second AutoTest.
copper cables.
• Complies to Encircled Flux requirement.
• Independent adaptor modules for both Channel and permanent link
SET REFERENCE METHOD
testing have a replaceable permanent link cord.
• 1 Jumper Method, 2 Jumper Method, or 3 Jumper Method.
• Both TERA and GG45/ARJ45 interfaces are available through test • Single-mode, Dual Wavelength at 1310nm, and 1550nm.
adapters • SC Connector Interface, 24 dB Dynamic Range.

• Length Measurement : 0-20km.


• Internal memory is capable of storing over 2000 test results complete
• Multi-mode, Dual Wavelength at 850nm and 1300nm
with graphical data.
• 850 nm VCSEL, 1300 nm LED.
• Extensive cable database and predefined test settings minimize startup • SC Connector Interface.
time and potential errors. • 24 dB Dynamic Range.

• Length Measurement : 0-2000m.


• Customizeable test limits can easily be created to meet any unique

testing parameters. TEST METHOD

• Single Directional, Bi-Directional.


• The powerful Li-Ion battery provides a full workday of battery life,
• Single Ended Test, Dual Ended Test.
allowing you to complete your project on a single charge.
PLUG-IN TEST ADAPTER MODULES
WireXpert MODULAR SYSTEM Quick-swap, rugged adapter modules fit firmly into the recessed
4500 dock to withstand a bench-top drop test. With the optional plug-in

test adaptor modules you’ll never have to buy a new unit as higher
Patch-Cord Testing
certification levels emerge.
WireXpert offers an efficient way for quickly identifying and
recording the performance of patch-cords. With its fast and
accurate dual-ended testing, WireXpert‘s patch-cord test kits are
suitable for both manufacturing testing, as well as for incoming
inspection at end user premises.

WireXpert patch-cord test kits are available for testing CAT5e,


CAT6, CAT6A, and CAT7/7A patch-cords.

Copper Patch-Cord Adapter Modules

Industrial Ethernet Testing

WireXpert‘s industrial Ethernet cabling test solution comprise of


M12 adapter kits. Both channel and permanent link configurations
with M12 industrial Ethernet connector are supported.

Industrial Ethernet kit with X-Coded M12 interface is also available,


making it possible to effectively test 10-Gig ready industrial
Ethernet cables.

Industrial Ethernet Cabling Adapter Modules

MPO/MTP Testing

WireXpert‘s versatile MPO testing solution enables data center


IT managers to get quick and accurate assessment of the quality
of MPO links. The 5-second Autotest includes a detection of fiber
connection map and measurement of loss on each channel. A
typical test setup consists of WireXpert local unit with MPO power
meter adapter, and the remote unit with MPO light source adapter
attached. Alternatively, a multimode fiber adapter can be attached
to WireXpert local unit for testing individual fibers in MPO link. This
solution provides a fast and accurate measurement of MPO link
loss and testing against user configured limit.
MPO/MTP Adapter Modules

Laboratory Testing of Cables and components

WireXpert features extremely versatile adapters that enable the


lab technicians to replace expensive Vector Network Analyser with
WireXpert for performing differential S-parameter measurements
THE NEXT GENERATION CERTIFIER
over 1MHz to 2500MHz.
If you are testing 10 Gb/s cabling, WireXpert is the clear choice. If you are thinking beyond 10G, WireXpert is the only
Coax cable test
choice. Built on a future proof, scalable measurement engine, WireXpert protects your investment in test equipment as
With coax test adapters, WireXpert supports testing of coaxial the data rates supported by the cabling systems increase. The WireXpert employs a novel measurement architecture
cables for attenuation and return loss over a wide frequency band.
that achieves extremely wide bandwidth with superior measurement accuracy. Its unique RF measurement engine
VNA Lab Adapter Modules exceeds level IV and level V requirements throughout the easurement frequency range.
WireXpert TEST, CERTIFY & PRINT REPORT PROFESSIONAL— REPORTXPERT
4500 Seamlessly integrates copper and fiber reports. Save time managing results, from setup to reporting. The WireXpert certification solution

Generate professional warranty and certification test reports includes ReportXpert, a PC based reporting software that produces professional reports

Report Samples in summary or full color graphical formats.

TIA Cat 5e Permanent Link TIA Cat 6A Channel


 

       


         
     
       
       
       
       
        
  
 

   


 
   
   
   
   
   

   


   
     
     
     
     
     

   


   
     
     
     
     
     

   


   
     
     
     
     
     

     

   

TIA Cat 7A Link TIA Cat 7A Channel


 

       


         
     
       
       
       
       
           
 

   


 
   
   
   
   
   

   


   
     
     
     
     
     

   


   
     
     
     
     
     

   


   
     
     
     
     
     

     

   

PROFESSIONAL INVESTMENT
Test, certify, report and print against new and emerging cabling standards—required for

40G Ethernet and beyond.


ERGONOMIC INTERFACE
WireXpert Schematics The result, is an efficient ergonomically comfortable interconnect,
4500
whether in stand alone position, cantilevered on the swing-out sup

port, laying flat, or hand held.

Probe interface connector

TOP VIEW Audio jack for headset connection

4.96” 3.41” USB host connector for flash drive—easy data storage in the field
126 mm 86.7 mm

RJ45 Ethernet for remote control

Power supply jack (12V)

9.13”
232 mm

FRONT VIEW SIDE VIEW

THE REVOLUTIONARY WIREXPERT


A new revenue generating opportunity. Whether you are a cable

manufacturer, installer or the end user, the WireXpert delivers

cable certification and network assurance that pays back faster on

every level.
WireXpert Specifications WireXpert Bill of Materials
4500 4500
Specifications Test Parameters Product Features WireXpert Item Quantity Object

Frequency Supported range: 1 to 2500 MHz Cat 6A Autotest time (seconds) 9 1 2 WireXpert: Handheld Units

Accuracy Exceeds TIA 1152 level IIIe, ISO/IEC 61935-1 Level IV accuracy and ISO 61935- Maximum bandwidth (MHz) 2500 2 2 Li-Ion Batteries
1 draft level V Accuracy level V 3 2 Stylus with Cords
Length 500m Max for dual ended Autotest 6” Color touch-panel display on both units • 4 2 Display Protection Covers
Insertion Cycles Channel: 10,000 typical Stores graphical results data • 5 2 CAT 6A Permanent Link Interface Adapters
Permanent link: 5,000 typical
Internal storage capacity (full graphical 2000 6 2 CAT 6A Permanent Link Test Cords
plots)
7 2 CAT 6A Channel Adapters
Supported Attenuation (Insertion Loss) Ruggedized plastic with rubber over-mold •
Copper Cable Tests 8 1 USB Thumb Drive includes Manual and Software
Near-end crosstalk (NEXT) in pair-to-pair and PowerSum format Lithium ion batteries – battery working life 8-hrs
9 2 Talk Head Sets
Attenuation-to-crosstalk ratio far end (ACRF), pair-to-pair and power-sum Advanced diagnostics •
10 2 AC Power Adapters
Return loss USB External Storage •
11 2 Country Specific Power Cord
Loop resistance Cat 6A permanent link adapter •
12 1 Calibration Certificate
Wiremap and shield Cat 6A channel adapter •
13 1 Carrying Case
Cable length Protected against Telco voltages •
14 1 Quick Reference Guide
Total propagation delay Start autotest at smart remote •
Delay skew between pairs Talk between Local and Remote •
Time-domain fault Locator for RL and NEXT Multimode Fiber adapter kit
Singlemode Fiber adapter kit
option
option
Notes:
Connectivity Probe interface connector MPO test kit option
RJ45 Ethernet port for remote control
USB host and device interfaces
Talk set interface: 3.5 mm stereo jack

Test Standards TIA -568-C.2 and TIA 1152 Category 5, 5e, 6, 6A, draft Category 8
ISO/IEC 11801, EN 50173 Class D, E, EA, F, FA draft Class I and Class II Perma-
nent link and channel

Power Supply AC power adapter 100−240V to 12V, 3A


ISO/IEC 11801, EN 50173, Class D, E, EA, F, FA Power Supply
Removable/Rechargeable. Li-Ion batteries provide 8 hours of continuous
operation

Memory More than 2000 full graphical test results saved internally
USB Flash Drive included, for flexible test record storage

Calibration period 1 year


Supported Languages Chinese, Czech, English, Finnish, French, German, Italian, Japanese, Korean,
Polish, Portuguese, Russian, Spanish, Swedish, Turkish
Dimensions Size 232 x 126 x 86.7 mm (9.13 x 4.96 x 3.41 in)
Weight Approx. 3.0 lb (1.4 kg) per unit

Environmental Operating temperature 0 to 40°C


Storage temperature −20 to 60°C
Relative humidity 10 to 80%
WireXpert Cable Certifier
4500

www.psiber.com About Psiber Data Systems

• Founded in San Diego in 1994, Psiber

Data Systems is a trusted provider of

network test, monitoring and certification

solutions to speed the deployment,

performance and maintenance of

networks and applications.

• Leading enterprises and service

providers trust Psiber products, and

expertise, to help solve todays and

emerging toughest challenges in network

testing and certification.

• With a closely aligned global distribution

and services network, Psiber Data

Systems has established trust and

reliability with the speed, functionality

and value of its products. The company

is in a unique position to continue to help

customers and contractors solve network

problems and take advantage of growth

opportunities.

Psiber Data Systems Inc.


7075-K Mission Gorge Road
San Diego, CA 92120
619 287 9973

© 2013 Psiber Data Systems Inc. All rights reserved.

You might also like