Caution: Photovoltaic system performance predictions calculated by PVWatts® include many inherent assumptions and Month Solar Radiation AC Energy Value uncertainties and do not reflect variations between PV technologies nor site-specific ( kWh / m2 / day ) ( kWh ) ($) characteristics except as represented by PVWatts® inputs. For example, PV modules with better performance are not January 4.82 3,325,230 162,936 differentiated within PVWatts® from lesser performing modules. Both NREL and private companies provide more sophisticated PV February 5.49 3,332,519 163,293 modeling tools (such as the System Advisor Model at https://sam.nrel.gov) that allow for March 5.67 3,856,876 188,987 more precise and complex modeling of PV systems. April 5.47 3,555,890 174,239 The expected range is based on 30 years of actual weather data at the given location and is intended to provide an indication of May 4.86 3,247,589 159,132 the variation you might see. For more information, please refer to this NREL report: The Error Report. June 4.05 2,694,664 132,039
July 4.34 2,977,862 145,915
Disclaimer: The PVWatts® Model ("Model") August 4.33 2,940,337 144,077
is provided by the National Renewable Energy Laboratory ("NREL"), which is operated by the Alliance for Sustainable September 4.33 2,833,487 138,841 Energy, LLC ("Alliance") for the U.S. Department Of Energy ("DOE") and may be used for any purpose whatsoever. October 4.66 3,129,816 153,361 The names DOE/NREL/ALLIANCE shall not November 5.22 3,403,257 166,760 be used in any representation, advertising, publicity or other manner whatsoever to endorse or promote any entity that adopts or December 4.90 3,363,629 164,818 uses the Model. DOE/NREL/ALLIANCE shall not provide
any support, consulting, training or
Annual 4.85 38,661,156 $ 1,894,398 assistance of any kind with regard to the use of the Model or any updates, revisions or new versions of the Model.
YOU AGREE TO INDEMNIFY Location and Station Identification
DOE/NREL/ALLIANCE, AND ITS AFFILIATES, OFFICERS, AGENTS, AND EMPLOYEES AGAINST ANY CLAIM OR DEMAND, Requested Location shillong, meghalaya, india INCLUDING REASONABLE ATTORNEYS' FEES, RELATED TO YOUR USE, RELIANCE, OR ADOPTION OF THE MODEL FOR ANY Weather Data Source Lat, Lon: 25.55, 91.85 2.7 mi PURPOSE WHATSOEVER. THE MODEL IS PROVIDED BY DOE/NREL/ALLIANCE "AS IS" Latitude 25.55° N AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF Longitude 91.85° E MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL PV System Specifications (Residential) DOE/NREL/ALLIANCE BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER, DC System Size 30000 kW INCLUDING BUT NOT LIMITED TO CLAIMS ASSOCIATED WITH THE LOSS OF DATA OR PROFITS, WHICH MAY RESULT FROM ANY Module Type Standard ACTION IN CONTRACT, NEGLIGENCE OR OTHER TORTIOUS CLAIM THAT ARISES OUT Array Type Fixed (open rack) OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE MODEL. Array Tilt 15° The energy output range is based on analysis of 30 years of historical weather data for nearby , and is intended to provide Array Azimuth 180° an indication of the possible interannual variability in generation for a Fixed (open System Losses 14.08% rack) PV system at this location.